Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Pharm Biomed Anal ; 246: 116224, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759321

RESUMO

Cardiovascular diseases, including fatal myocardial infarctions from atheromatous plaques, are the primary global mortality cause. Detecting stenotic atheromatous plaques is possible through coronary angiography, but vulnerable plaques with eccentric remodeling are undetectable with current diagnostic methods. Addressing this challenge, our group developed a radiopharmaceutical drug targeting vascular cell adhesion molecule 1 (VCAM-1), radiolabeled with technetium-99m. Given the absence of a monograph in the European Pharmacopoeia, and in order to draft the investigational medicinal product documentation, analytical methods had to be validated by high performance liquid chromatography (HPLC) and thin layer chromatography (TLC) to determine the radiochemical purity (RCP) of 99mTc-cAbVCAM1-5. This study therefore presents the results of the validation of analytical methods obtained in this context. The method validation followed the European Association of Nuclear Medicine (EANM) recommendations adapted from ICH Q2(R1), ensuring conformity with specificity, accuracy, repeatability and intermediate precision, linearity, robustness, quantification limit (LoQ), and range criteria. Regarding the results of specificity, both HPLC and TLC methods demonstrated excellent separation of 99mTc-cAbVCAM1-5 from impurities 99mTcO4-. Accuracy results indicated recovery percentages within the range of 99.52-101.40% for the HPLC and 99.51-101.97% for TLC, ensuring reliable measurements for each concentration of 99mTcO4-. Precision of the methods was validated by assessing repeatability and intermediate precision. Linearity was determined over the usual concentrations range and the correlation coefficient was greater than 0.99 for both methods. The limit of quantification was measured by diluting the 99mTcO4- to obtain a signal-to-noise ratio of around 10:1. Under these conditions, we obtained an LOQ of 2.10 MBq/mL for HPLC and 2Mbq/mL for TLC. In conclusion, the analytical methods developed in this study comply with EANM recommendations. This therefore allows us to correctly assess the radiochemical purity of 99mTc-cAbVCAM1-5, a new radiotracer targeting inflammation in vulnerable plaques.


Assuntos
Compostos Radiofarmacêuticos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Camada Fina/métodos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/análise , Reprodutibilidade dos Testes , Tecnécio/química , Tecnécio/análise , Compostos de Organotecnécio/química , Compostos de Organotecnécio/análise
2.
Ann Pharm Fr ; 82(2): 306-317, 2024 Mar.
Artigo em Francês | MEDLINE | ID: mdl-38159720

RESUMO

OBJECTIVES: To assess the impact of disparities in production and analytical control processes on the quality of parenteral nutrition (PN) preparations produced in the Auvergne-Rhône-Alpes region. METHODS: This study was carried out in four hospital pharmacies of the Auvergne-Rhône-Alpes region. To assess the impact of production processes, each centre produced ten PN preparations from the same prescription. Analytical controls (sodium, potassium and calcium dosage) were carried out on all the preparations. To assess the impact of the control processes, a batch of ten preparations was produced from the same prescription. Samples were sent to the four hospital pharmacies for analytical control (sodium, potassium and calcium dosage). RESULTS: Measurements of relative production bias show that there is a significant difference between the preparations from the four centres in terms of sodium and potassium content. Each centre had at least one production bias for one of the three electrolytes measured. Concerning analytical controls, there was a significant difference between the four centres in the sodium and potassium levels measured. With the exception of calcium, all the centres reported measurements within the usual specifications of±10% of the target value. The results obtained have no clinically significant impact. CONCLUSION: The diversity of NP practices has a real impact on the quality of the preparations made. A regional collaboration should be envisaged to standardise patient care.


Assuntos
Neonatologia , Humanos , Cálcio , Nutrição Parenteral/métodos , Sódio , Potássio
3.
EJNMMI Radiopharm Chem ; 8(1): 34, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37882937

RESUMO

BACKGROUND: The aim of this brief communication is to highlight the potential bacteriological risk linked to the processes control of radiopharmaceutical preparations made in a radiopharmacy laboratory. Survival rate of Pseudomonas aeruginosa (ATCC: 27853) or Staphylococcus aureus (ATCC: 25923) or Staphylococcus epidermidis (ATCC: 1228) in multidose technetium-99 m solution was studied. RESULTS: Depending on the nature and level of contamination by pathogenic bacteria, the lethal effect of radioactivity is not systematically observed. We found that P. aeruginosa was indeed affected by radioactivity. However, this was not the case for S. epidermidis, as the quantity of bacteria found in both solutions (radioactive and non-radioactive) was rapidly reduced, probably due to a lack of nutrients. Finally, the example of S. aureus is an intermediate case where we observed that high radioactivity affected the bacteria, as did the absence of nutrients in the reaction medium. The results were discussed in the light of current practices on the sterility test method, which recommends waiting for radioactivity to decay before carrying out the sterility test. CONCLUSION: In terms of patient safety, the results run counter to current practice and the latest EANM recommendation of 2021 that radiopharmaceutical preparations should be decayed before sterility testing.

4.
Res Pract Thromb Haemost ; 7(6): 102175, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37841511

RESUMO

Background: Gla-domainless factor (F) Xa (GD-FXa) was proposed as a trap to endogenous anticoagulant tissue factor pathway inhibitor (TFPI) to restore thrombin generation in hemophilia. Using computational chemistry and experimental approaches, we previously showed that S195A GD-FXa also binds TFPI and restores ex vivo coagulation in plasma obtained from person(s) with hemophilia. Methods: To design a GD-FXa variant with improved anti-TFPI affinity, we performed molecular dynamics simulations and identified suitable sites for mutagenesis. The calculations identified residues R150FXa and K96Fxa as cold-spots of interaction between GD-FXa and the K2 domain of TFPI. In the three-dimensional model, both residues face toward TFPI hydrophobic residues and are thus potential candidates for mutagenesis into hydrophobic residues to favor an improved protein-protein interaction. Results: Catalytically inactive GD-FXa variants containing the S195A mutation and the additional mutations K96Y, R150I, R150G, R150F, and K96YR150F, were produced to experimentally confirm these computational hypotheses. Among these mutants, the R150FFXa and the K96YR150FFXa were slightly more effective than S195A GD-FXa in restoring coagulation in FVIII deficient plasmas. However, in surface plasmon resonance experiments, they showed TFPI binding affinities in the same range and acted similarly as S195A GD-FXa in FXa/TFPI competition assays. In contrast, the R150 mutants completely lost their interactions with antithrombin as observed in the surface plasmon resonance experiments. Conclusions: We therefore conclude that their antithrombin resistance is responsible for their improved thrombin generation, through an extension of their half-lives.

5.
Eur J Hosp Pharm ; 30(6): 347-352, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-34972687

RESUMO

OBJECTIVES: Automation of parenteral nutrition (PN) preparation is nowadays a recommended practice in order to reduce human errors and thus improve the safety and accuracy of the finished product. Other benefits of automation may include full documentation of preparation and a reduction in personnel requirements or staff injuries. The market of automation compounding presents different automated compounding devices (ACDs). The aim of this study is to compare the technical characteristics of ACDs by carrying out four specific challenges. METHODS: Three ACDs: Two piston pumps with ACD 1: MediMix Multi 4120R (Impromediform) and ACD 2: Mibmix Compounder C12 (Hemedis), and one peristaltic pump ACD 3: ExactaMix Compounder EM2400 (Baxter) were assessed in a pharmaceutical manufacturing unit within a controlled atmosphere area, under horizontal laminar flow hood (LFH) according to four tests: volumetric accuracy, flush volume, smoke test, and a production test with three configurations of PN bags. For this test, a PN bag was considered accepted when all quality controls (weight, molar concentration of sodium, potassium and calcium) were fulfilled. RESULTS: The maximum relative biases found for the different ACDs were heterogeneous. ACD 1 had the best volumetric accuracy with respect to supplier specifications and for extreme volumes (0.2 mL). Evaluation of the flushing volume allowed the validation of 50 mL volumes for ACD 1 and ACD 3. The smoke test was only conclusive for ACD 1 under a horizontal LFH. The percentage of PN bags accepted were 98.8% for ACD 1, 70% for ACD 2%, and 95.5% for ACD 3. CONCLUSION: This study compared three ACDs according to four relevant and specific tests. Based on the data acquired, we conclude that ACD 1 is the most accurate, has the lowest flushing volume, is suitable for use in a LFH, and achieves the best results in the production test.


Assuntos
Nutrição Parenteral , Serviço de Farmácia Hospitalar , Humanos , Cálcio , Automação , Controle de Qualidade
6.
Carbohydr Polym ; 301(Pt B): 120345, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36446494

RESUMO

Conformable biocompatible conductive materials are increasingly sought for the development of bioelectronics. If additionally resorbable, they could serve for the design of transient implantable electronic devices, opening the way to new healthcare applications. Hyaluronan (HA) derivatives including sulfate and aminophenylboronic acid (PBA) groups (HAS-PBA) were therefore designed to serve as dopants of poly(3,4-ethylenedioxy)thiophene (PEDOT). The optimized HA sulfation protocol allowed good control on polymer sulfation degree while minimizing polymer chain degradation. Sulfated HA was shown to be degradable in physiological conditions. A synergy was observed between the sulfate negative charges and the PBA aromatic groups promoting hydrophobic interactions and π-stacking between PEDOT and HAS-PBA, to boost the material conductivity that reached 1.6 ± 0.2 S/cm in physiological conditions. Moreover the PEDOT:HAS-PBA material was not cytotoxic and could be formulated for easy processing by inkjet printing, appearing as promising candidate for the design of soft transient electronics for in vivo applications.


Assuntos
Ácido Hialurônico , Tinta , Polímeros , Sulfatos , Materiais Biocompatíveis/farmacologia , Óxidos de Enxofre
7.
Anal Chem ; 94(45): 15546-15552, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36342126

RESUMO

A new analytical methodology, using capillary electrophoresis in indirect UV absorbance mode, is developed for the quantification of analytes in the absence of reference materials. The methodology allows the quantification of organic molecules and/or small ions, anionic or cationic, absorbing or not in the UV range, carrying either one or two electric charges. Two methods of data processing were compared. The first is based on the use of a dynamic simulator of electromigration, and the second uses the Kohlrausch regulating function combined with the electroneutrality equation. The experimental conditions presented in this work allow a precise quantification of anions having electrophoretic mobilities (µep) between -22.71 and -36.92 × 10-9 m2 V-1 s-1 and cations with µep between +30.59 and +63.60 × 10-9 m2 V-1 s-1 with percent relative errors lower than -5.52%. The effect of the integration errors on the reliability of the results is discussed in detail.


Assuntos
Eletricidade , Eletroforese Capilar , Reprodutibilidade dos Testes , Ânions/análise , Cátions , Eletroforese Capilar/métodos
8.
Eur J Pharm Sci ; 179: 106275, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35987326

RESUMO

Automated compounding device (ACD) are increasingly used for parenteral nutrition (PN) bag production, and their acquisition must be sufficiently thought. The law requires the qualification of these ACD, but did not specify the tests to be performed. The quality by design (QbD) risk based approach allowed to define the quality target product profile in order to acquire the best ACD for each unit, and thanks a risk analysis permitted to define the critical quality attributes (CQA). These CQA will allowed to define tests performed during qualification. The ACD qualified was a 12 pump volumetric system. The CQA for PN bags consisted in sterile, precisely and accurately production with enough stability. During operational qualification volumetric accuracy test was performed, and during the performance qualification: flush volume, media fill, microbiological integrity of environment, sterility of control bag and production test were performed. At the end, all tests were conclusive (excepted for some results mostly due to analytical bias) and the ACD was considered to produce sterile bags in a control environment, precisely (relative standard deviation < 4%) and accurately (mean bias < 1% for weight and < 7% for other controls) with a sufficient stability. The QbD risk based approach allowed to acquire the best ACD for our need, and qualify relevant elements regarding the production process.


Assuntos
Nutrição Parenteral , Medição de Risco , Composição de Medicamentos
9.
Soft Matter ; 18(10): 2028-2038, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35191906

RESUMO

Colloidal nanoparticles were prepared by aqueous self-assembly of amphiphilic ß-cyclodextrins (ßCDs) acylated on their secondary face with C14 chains to a total degree of substitution of 7.0, via a thermolysin-catalyzed transesterification process. The small-angle X-ray scattering pattern of the nanoparticles was consistent with a reverse hexagonal organization. Cryo-transmission electron microscopy images revealed particles with spectacular tortuous shapes and consisting of misoriented domains with a regular columnar hexagonal structure, separated by sharp interfaces. Edge dislocations as well as a variety of stepped tilt grain boundaries (GBs) composed of symmetrical and asymmetrical sections, together with one twist GB, were identified from axial views of the columnar organization. The tilt GB structure was analyzed using the concepts of coincidence site lattice and structural units developed to describe the atomic structure of interfaces in various types of polycrystals. The tilt GBs were described using sequences of ßCD-C14 columns that differed by the number of neighboring columns (5, 6 or 7) and exhibiting distinctive contrasts. To our knowledge, this is the first time that these types of topological defects are described at the nanometric scale by direct observation of colloidal polycrystalline hexosomes of self-organized amphiphiles.

10.
Anal Bioanal Chem ; 413(27): 6823-6835, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34494123

RESUMO

A new gas chromatography-tandem mass spectrometry method for the determination of mono- and dihydroxylated polycyclic aromatic hydrocarbon metabolites (OH-PAHs and diol-PAHs) in urine was developed and validated. Various sample preparation procedures were compared, namely liquid-liquid extraction (LLE), dispersive solid-phase extraction (dSPE), and SPE, alone or combined. A novel two-stage derivatization approach using 2 silylation reagents was developed, and an experimental procedure design was used to optimize the programmed temperature vaporization-solvent vent injection (PTV-SV) GC parameters. The method focused on 11 target compounds resulting from four- to five-ring suspected carcinogenic PAHs. SPE was identified as an acceptable and more convenient extraction method for all tested metabolites, with extraction rates ranging from 63 to 86% and relative standard deviations lower than 20%. The two-stage derivatization approach successfully allowed first the derivatization of OH-PAHs by MTBSTFA (N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) and then diol-PAHs by BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) in a single run. The limits of quantification were in the range of 0.01-0.02 µg l-1 for OH-PAHs and 0.02-0.2 µg l-1 for diol-PAHs. The intra- and interday precisions were lower than 10%. The method was applied to determine PAH metabolites in urine collected at the beginning and at the end of the working week from 6 workers involved in aluminum production. The mean diol-PAH levels at the end of the week were 10 to 20 times higher (0.86-2.34 µg g-1 creatinine) than those of OH-PAHs (0.03-0.30 µg g-1). These results confirmed the usefulness of this new analytical technique for detecting and characterizing metabolic patterns of PAHs in urine and assessing carcinogenic occupational exposures.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/urina , Extração em Fase Sólida/métodos , Alumínio , Calibragem , Poluentes Ambientais/análise , Humanos , Hidroxilação , Extração Líquido-Líquido/métodos , Metalurgia , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/metabolismo , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
11.
Mar Drugs ; 19(6)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072871

RESUMO

Chitin oligosaccharides (COs) hold high promise as organic fertilizers in the ongoing agro-ecological transition. Short- and long-chain COs can contribute to the establishment of symbiotic associations between plants and microorganisms, facilitating the uptake of soil nutrients by host plants. Long-chain COs trigger plant innate immunity. A fine investigation of these different signaling pathways requires improving the access to high-purity COs. Here, we used the response surface methodology to optimize the production of COs by enzymatic hydrolysis of water-soluble chitin (WSC) with hen egg-white lysozyme. The influence of WSC concentration, its acetylation degree, and the reaction time course were modelled using a Box-Behnken design. Under optimized conditions, water-soluble COs up to the nonasaccharide were formed in 51% yield and purified to homogeneity. This straightforward approach opens new avenues to determine the complex roles of COs in plants.


Assuntos
Quitina/química , Muramidase/química , Oligossacarídeos/química , Acetilação , Hidrólise
12.
Carbohydr Polym ; 261: 117885, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33766372

RESUMO

Rectangular V-amylose single crystals were prepared by adding racemic ibuprofen to hot dilute aqueous solutions of native and enzymatically-synthesized amylose. The lamellar thickness increased with increasing degree of polymerization of amylose and reached a plateau at about 7 nm, consistent with a chain-folding mechanism. The CP/MAS NMR spectrum as well as base-plane electron and powder X-ray diffraction patterns recorded from hydrated specimens were similar to those of V-amylose complexed with propan-2-ol. Amylose was crystallized in an orthorhombic unit cell with parameters a = 2.824 ± 0.001 nm, b = 2.966 ± 0.001 nm, and c = 0.800 ± 0.001 nm. A molecular model was proposed based on structural analogies with the Vpropan-2-ol complex and on assumptions on the stoichiometry of ibuprofen. The unit cell would contain four antiparallel 7-fold amylose single helices with ibuprofen molecules distributed inside and between the helices.


Assuntos
Amilose/química , Ibuprofeno/química , Nanopartículas/química , Varredura Diferencial de Calorimetria , Cristalização , Microscopia Eletrônica de Transmissão , Modelos Moleculares , Estrutura Molecular , Nanoconjugados/química , Polimerização , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
14.
Pharmaceutics ; 12(8)2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32751583

RESUMO

We previously developed two optimized formulations of dexamethasone acetate (DXMa) hydrogels by means of special cubic mixture designs for topical ocular administration. These gels were elaborated with hydroxypropyl-ß-CD (HPßCD) and hydroxypropyl-γ-CD (HPγCD) and commercial hydrogels in order to enhance DXMa water solubility and finally DXMa's ocular bioavailability and transcorneal penetration. The main objective of this study was to characterize them and to evaluate in vitro, ex vivo, and in vivo their safety, biopermanence, and transcorneal permeation. Gels A and B are Newtonian fluids and display a viscosity of 13.2 mPa.s and 18.6 mPa.s, respectively, which increases their ocular retention, according to the in vivo biopermanence study by PET/CT. These hydrogels could act as corneal absorption promoters as they allow a higher transcorneal permeation of DXMa through porcine excised cornea, compared to DEXAFREE® and MAXIDEX®. Cytotoxicity assays showed no cytotoxic effects on human primary corneal epithelial cells (HCE). Furthermore, Gel B is clearly safe for the eye, but the effect of Gel A on the human eye cannot be predicted. Both gels were also stable 12 months at 25 °C after sterilization by filtration. These results demonstrate that the developed formulations present a high potential for the topical ocular administration of dexamethasone acetate.

15.
Pharmaceutics ; 12(6)2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32575411

RESUMO

Ocular inflammation is one of the most common symptom of eye disorders and diseases. The therapeutic management of this inflammation must be rapid and effective in order to avoid deleterious effects for the eye and the vision. Steroidal (SAID) and non-steroidal (NSAID) anti-inflammatory drugs and immunosuppressive agents have been shown to be effective in treating inflammation of the ocular surface of the eye by topical administration. However, it is well established that the anatomical and physiological ocular barriers are limiting factors for drug penetration. In addition, such drugs are generally characterized by a very low aqueous solubility, resulting in low bioavailability as only 1% to 5% of the applied drug permeates the cornea. The present review gives an updated insight on the conventional formulations used in the treatment of ocular inflammation, i.e., ointments, eye drops, solutions, suspensions, gels, and emulsions, based on the commercial products available on the US, European, and French markets. Additionally, sophisticated formulations and innovative ocular drug delivery systems will be discussed. Promising results are presented with micro- and nanoparticulated systems, or combined strategies with polymers and colloidal systems, which offer a synergy in bioavailability and sustained release. Finally, different tools allowing the physical characterization of all these delivery systems, as well as in vitro, ex vivo, and in vivo evaluations, will be considered with regards to the safety, the tolerance, and the efficiency of the drug products.

16.
Mater Sci Eng C Mater Biol Appl ; 106: 110281, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31753335

RESUMO

Artemisinin and its derivatives are currently recommended by World Health Organization for the treatment of malaria. Severe malaria requires a parenteral administration of artemisinin-based formulations. However, the effective use of artemisinin is limited by the pharmacokinetic characteristics of the drug (low water solubility, poor bioavailability and short half-life). To overcome some of these drawbacks, artemisinin-loaded surface-decorated nanoparticles were prepared by co-nanoprecipitation of γ-cyclodextrin bioesterified with C10 alkyl chains and polyethylene glycol (PEG) derivatives (polysorbate 80 and DMPE-mPEG2000). Using a single dose (1.5 mg kg-1 or 2 mg kg-1) by intravenous administration, we investigated the in vivo pharmacokinetic properties in healthy rats of two types of artemisinin-loaded nanoparticle formulations, namely, nanosphere and nanoreservoir systems versus an ethanolic-aqueous solution of artemisinin as reference. Significantly enhanced pharmacokinetic parameters were obtained with artemisinin-loaded nanoparticles. In comparison to reference formulation, the geometric mean exposures in plasma (AUC0-t) exhibited 2.35 and 3.26-fold increases when artemisinin was loaded in nanoreservoir and nanosphere systems, respectively. Its plasma half-life increased 4.00 and 6.25-fold and its clearance decreased up to 2.5 and 4.72-fold. Artemisinin was successfully administered intravenously by means of surface-decorated amphiphilic γ-cyclodextrin nanostructures and showed a longer elimination half-life with respect to an artemisinin solution in ethanol. Therefore, these systems are likely to provide significant advantages for the intravenous treatment of severe malaria.


Assuntos
Antimaláricos/farmacocinética , Artemisininas/química , Nanopartículas/química , gama-Ciclodextrinas/química , Administração Intravenosa , Animais , Antimaláricos/sangue , Antimaláricos/química , Artemisininas/sangue , Artemisininas/farmacocinética , Portadores de Fármacos/química , Meia-Vida , Masculino , Tamanho da Partícula , Polietilenoglicóis/química , Ratos , Ratos Wistar , Propriedades de Superfície
17.
J Chromatogr A ; 1597: 220-224, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-30876739

RESUMO

Titration methods are routinely used in the laboratories for the quantification of acids and bases, for the complexometric determination of metal ions and for the ion-pair titrations of drugs in pharmaceutical control. They also find application in a wide variety of chemical and biochemical studies. However, conventional titration methods (CTM) require large amounts of samples that are not always available. In absence of micro-titrator devices, the application of these methods for expensive samples and for small batch sizes is not possible. In this work, it was demonstrated that the commercial capillary electrophoretic apparatus (CEa) can be used, in a quick and easy way, for the end-point detection in a microtitration process. The proposed methodology exploits the change of the solutions conductivity during the titrations. The equivalent points can be easily located by plotting the change in electrical current as a function of the titrant volume added. More interestingly, only 1.1-1.5 mL of analyte solutions are required to establish the titration curves. The advantages and the limitations of the procedure are discussed in detail.


Assuntos
Condutividade Elétrica , Eletroforese Capilar , Titulometria/métodos , Íons/análise , Metais/análise , Titulometria/normas
18.
Pharmaceutics ; 10(4)2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30513707

RESUMO

Dexamethasone acetate (DXMa) has proven its efficiency to treat corneal inflammation, without a great propensity to increase intraocular pressure. Unfortunately, its poor aqueous solubility, associated with a rapid precorneal elimination, results in a low drug bioavailability and a low penetration after topical ocular administration. The main objective of this study was to improve the apparent aqueous solubility of DXMa using cyclodextrins. First, hydroxypropyl-ß-CD (HPßCD) and hydroxypropyl-γ-CD (HPγCD) were used to enhance DXMa concentration in aqueous solution. The ß and γ HPCD derivatives allowed the increase of the DXMa amount in solution at 25 °C by a factor of 500 and 1500, respectively. Second, with the aim of improving the persistence of the complex solution after instillation in the eye, the formulations of DXMa-based CD solutions with marketed ophthalmic gels (CELLUVISC®, GEL-LARMES®, and VISMED®) were investigated and optimized by means of special cubic mixture designs, allowing the defining of mixed gels loaded with 0.7% (HPßCD) and 2% (HPγCD) DXMa with osmolality within acceptable physiological range. Finally, in vitro drug release assays from the mixed gels were performed and compared with reference eye drops. Similarly to MAXIDEX® and DEXAFREE®, in the case of mixed gel containing HPßCD, more than 90% of the drug was released within 2 h, while in mixed gel containing HPγCD, the release of DXMa was partial, reaching ≈60% in 2 h. This difference will have to be further addressed with ex vivo and in vivo ocular delivery experiments.

19.
Int J Biol Macromol ; 119: 555-564, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30059739

RESUMO

The crystallization of amylose from dilute solutions in the presence of a series of linear saturated fatty acids (C3 to C20) was investigated by varying the fatty acid concentration, crystallization temperature and solvent composition (DMSO:water in various ratios). The morphology and structure of the resulting model lamellar crystals were characterized by transmission electron microscopy as well as electron and X-ray diffraction. By adequately controlling the crystallization parameters, all fatty acids could induce the formation of both 6- and 7-fold V-amylose single helices, indicating that the amylose conformation was independent of the chain length of the complexing molecule. Three allomorphs (V6I, V6II and V7) were identified individually or in mixtures. Higher concentrations of fatty acid and DMSO and a higher temperature promoted the formation of the more compact V6I structure. V6II and V7 preferentially formed with lower concentrations of fatty acids and DMSO and at lower temperatures. In the case of C5-C20 fatty acids, V7 was only obtained in the presence of DMSO. The polymorphism of V-amylose complexes with linear saturated fatty acids thus appears to be a more general phenomenon than previously reported in the literature.


Assuntos
Amilose/química , Ácidos Graxos/química , Cristalização
20.
Anal Chem ; 90(4): 2493-2500, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29359557

RESUMO

The inline coupling of the field-amplified sample injection (FASI) to Taylor dispersion analysis (TDA) was used to characterize low-UV absorbing carboxylated silica nanoparticles (cNPs). The hydrodynamic diameters (Dh) were measured by using a commercial capillary electrophoresis instrument. The proposed methodology did not require any complicated instruments or chromophoric dye to increase the detection sensitivity. A practical method based on a half-Gaussian fitting was proposed for the data processing. The results obtained by this method were compared with those derived from dynamic light scattering (DLS) and transmission electron microscopy (TEM) analyses. From these results, it appeared that the size derived by TDA is in excellent agreement with those measured by DLS and TEM, as demonstrated by stable nanoparticles with narrow size distributions. Intermediate precision relative standard deviations less than 5% were obtained by FASI-TDA. The effect of the FASI-induced cNP peak dispersion on the reliability of the results was discussed in detail.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA