Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Viruses ; 13(5)2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33946860

RESUMO

Antigen tests for SARS-CoV-2 diagnosis are simpler and faster than their molecular counterparts. Clinical validation of such tests is a prerequisite before their field applications. We developed and clinically evaluated an immunochromatographic immunoassay, GenBody™ COVAG025, for the rapid detection of SARS-CoV-2 nucleocapsid (NP) antigen in two different clinical studies. Retrospectively, 130 residual nasopharyngeal swabs transferred in viral transport medium (VTM), pre-examined for COVID-19 through emergency use authorization (EUA)-approved real-time RT-PCR assay and tested with GenBody™ COVAG025, revealed a sensitivity and specificity of 90.00% (27/30; 95% CI: 73.47% to 97.89%) and 98.00% (98/100; 95% CI: 92.96% to 99.76%), respectively, fulfilling WHO guidelines. Subsequently, the prospective examination of 200 symptomatic and asymptomatic nasopharyngeal swabs, collected on site and tested with GenBody™ COVAG025 and EUA-approved real-time RT-PCR assay simultaneously, revealed a significantly higher sensitivity and specificity of 94.00% (94/100; 95% CI: 87.40% to 97.77%) and 100.00% (100/100; 95% CI: 96.38% to 100.00%), respectively. Clinical sensitivity and specificity were significantly high for samples with Ct values ≤ 30 as well as within 3 days of symptom onset, justifying its dependency on the viral load. Thus, it is assumed this can help with the accurate diagnosis and timely isolation and treatment of patients with COVID-19, contributing to better control of the global pandemic.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Nasofaringe/virologia , SARS-CoV-2/isolamento & purificação , Testes Diagnósticos de Rotina , Humanos , Índia/epidemiologia , Fosfoproteínas/imunologia , Estudos Prospectivos , República da Coreia/epidemiologia , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Diagnostics (Basel) ; 11(3)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802842

RESUMO

There is a need for accurate diagnostic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the cause of coronavirus disease (COVID-19). This study aimed to evaluate the diagnostic accuracy of an immunochromatography-based immunoglobulin G (IgG)/immunoglobulin M (IgM) antibody assay (GenBody™ COVI040) for detecting SARS-CoV-2 antibody seroconversion in COVID-19 patients. A total of 130 samples, serially collected from patients with confirmed COVID-19, and 100 negative control samples were tested for anti-SARS-CoV-2 IgM and IgG using the GenBody™ COVI040 assay following the South Korean Ministry of Food and Drug Safety guidelines on the review and approval of in vitro diagnostic devices for COVID-19. Reverse-transcription polymerase chain reaction results were used as the comparator. The overall sensitivity of the GenBody™ COVI040 assay was 97.69% (95% confidence interval (CI): 93.40-99.52%). The sensitivity of the assay increased with time post symptom onset (PSO) (sensitivity ≤6 days PSO: 78.57%, 95% CI: 49.20-95.34%; sensitivity 7-13 days PSO: 100%, 95% CI: 87.23-100%; and sensitivity ≥14 days PSO: 100%, 95% CI: 95.94-100%). The specificity of the assay was 100% (95% CI: 96.38-100%). The GenBody™ COVI040 assay showed high sensitivity and specificity, making it a promising diagnostic test to monitor COVID-19.

3.
Korean J Parasitol ; 59(1): 9-14, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33684982

RESUMO

Toxoplasma gondii seroprevalence have been rapidly increasing in some parts of Korea. We analyzed prevalence of anti-Toxoplasma gondii antibodies, using a rapid diagnostic test (RDT), in the sera of 552 residents in Ganghwa-gun, 661 ones in Cheorwon-gun, and 305 ones in Goseong-gun, Korea in 2019. IgG/IgM RDT mounted with recombinant fragment of major surface antigen (SAG1), glutathione-S-transferase-linker-SAG1A, were applied to the sera. IgG seroprevalence was 28.1% in Ganghwa-gun, 19.5% in Cheorwon-gun and 35.7% in Goseong-gun. Odds ratios comparing Cheorwon vs Ganghwa was 0.63 (P=0.001) and Goesong versus Ganghwa was 1.47 (P=0.01) adjusting age and sex. Goseong had highest seroprevalence among the 3 counties both in crude rates and logistic regression. Although Cheorwon and Goseong are adjacent to the demilitarized zone (DMZ) in Korea, seroprevalence rate was much higher in Goseong. Further investigation on other DMZ-closed areas is necessary whether they have high prevalence rates compared to the other areas. T. gondii prevalence in Korea is still persists; proper health policy should be established.


Assuntos
Testes Sorológicos/métodos , Toxoplasma , Toxoplasmose/diagnóstico , Toxoplasmose/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antiprotozoários/sangue , Antígenos de Protozoários , Biomarcadores/sangue , Feminino , Humanos , Imunoglobulina G , Imunoglobulina M , Masculino , Pessoa de Meia-Idade , Prevalência , Proteínas de Protozoários , República da Coreia/epidemiologia , Estudos Soroepidemiológicos , Toxoplasma/imunologia , Toxoplasmose/parasitologia
4.
Korean J Parasitol ; 57(4): 435-437, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31533412

RESUMO

Chagas disease is caused by the protozoan parasite Trypanosoma cruzi, and is endemic in many Latin American countries. Diagnosis is based on serologic testing and the WHO recommends two or more serological tests for confirmation. Acidic ribosomal P protein of T. cruzi showed strong reactivity against positive sera of patients, and we cloned the protein after fragmenting it to enhance its antigenicity and solubility. Twelve positive sera of Chagas disease patients were reacted with the fragmented ribosomal P protein using western blot. Detection rate and density for each fragment were determined. Fragments F1R1, F1R2, and F2R1 showed 100% rate of detection, and average density scoring of 2.00, 1.67, and 2.42 from a maximum of 3.0, respectively. Therefore, the F2R1 fragment of the ribosomal P protein of T. cruzi could be a promising antigen to use in the diagnosis of Chagas disease in endemic regions with high specificity and sensitivity.


Assuntos
Anticorpos Antiprotozoários/sangue , Doença de Chagas/diagnóstico , Proteínas Ribossômicas/imunologia , Trypanosoma cruzi/imunologia , Western Blotting , Brasil , Doença de Chagas/sangue , Doença de Chagas/imunologia , Doenças Endêmicas , Humanos , Proteínas Recombinantes/imunologia
5.
Korean J Parasitol ; 57(3): 283-290, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31284351

RESUMO

A rapid diagnostic test (RDT) kit was developed to detect non-structural protein 1 (NS1) of yellow fever virus (YFV) using monoclonal antibody. NS1 protein was purified from the cultured YFV and used to immunize mice. Monoclonal antibody to NS1 was selected and conjugated with colloidal gold to produce the YFV NS1 RDT kit. The YFV RDTs were evaluated for sensitivity and specificity using positive and negative samples of monkeys from Brazil and negative human blood samples from Korea. Among monoclonal antibodies, clones 3A11 and 3B7 proved most sensitive, and used for YFV RDT kit. Diagnostic accuracy of YFV RDT was fairly high; Sensitivity was 0.0% and specificity was 100% against Dengue viruses type 2 and 3, Zika, Chikungunya and Mayaro viruses. This YFV RDT kit could be employed as a test of choice for point-of-care diagnosis and large scale surveys of YFV infection under clinical or field conditions in endemic areas and on the globe.


Assuntos
Testes Diagnósticos de Rotina/métodos , Proteínas não Estruturais Virais/análise , Febre Amarela/diagnóstico , Vírus da Febre Amarela/isolamento & purificação , Animais , Anticorpos Antivirais/análise , Anticorpos Antivirais/imunologia , Feminino , Haplorrinos , Humanos , Imunização , Camundongos , Sensibilidade e Especificidade , Proteínas não Estruturais Virais/genética , Proteínas não Estruturais Virais/imunologia , Febre Amarela/sangue , Febre Amarela/imunologia , Febre Amarela/virologia , Vírus da Febre Amarela/genética , Vírus da Febre Amarela/imunologia , Vírus da Febre Amarela/fisiologia
6.
Biochem Biophys Res Commun ; 505(4): 1010-1014, 2018 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-30309651

RESUMO

Zika virus (ZIKV), a mosquito-borne flavivirus that has recently emerged globally, poses a major threat to public health. To control this emerging disease, accurate diagnostics are required for monitoring current ZIKV outbreaks. Owing to the high nucleotide sequence similarity and cross-reactivity of ZIKV with other members of the Flaviviridae family, discrimination from other flavivirus infections is often difficult in endemic areas. ZIKV NS1 induces major virus-specific antibodies and is therefore utilized as a serological marker for ZIKV diagnosis. To identify ZIKV specific epitopes for clinical application, 33 NS1 peptides that are 15-30 amino acid in length covering whole NS1 were synthesized and analyzed linear B-cell epitopes with 38 human serum samples (20 ZIKV-positive and 18 ZIKV-negative). As a result of screening, eight epitope regions were identified. In particular, the Z8 and Z14 peptides located in the ß-ladder surface region showed higher levels of binding activity in ZIKV-positive sera without cross-reactivity to other flaviviruses. These identified sensitive and specific epitopes provide a tool for design of diagnostics and structure-based vaccine antigens for ZIKV infection.


Assuntos
Epitopos de Linfócito B/química , Peptídeos/análise , Zika virus/química , Epitopos de Linfócito B/sangue , Humanos , Modelos Moleculares , Peptídeos/síntese química
7.
Korean J Parasitol ; 56(1): 61-70, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29529852

RESUMO

We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Kit de Reagentes para Diagnóstico , Proteínas do Envelope Viral/imunologia , Proteínas não Estruturais Virais/imunologia , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia , Zika virus/imunologia , Reações Cruzadas , Vírus da Dengue , Humanos , Sensibilidade e Especificidade
8.
Theranostics ; 8(22): 6132-6148, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30613288

RESUMO

Accurate and rapid diagnosis of highly pathogenic avian influenza A H5N1 is of critical importance for the effective clinical management of patients. Here, we developed a rapid and simultaneous detection toolkit for influenza A H5 subtype viruses in human samples based on a bioconjugate of quantum dots (QDs) assembly and a smartphone-based rapid dual fluorescent diagnostic system (SRDFDS). Methods: Two types of QDs were assembled on a latex bead to enhance the detection sensitivity and specificity of influenza A infection (QD580) and H5 subtype (QD650). The dual signals of influenza A and H5 subtype of H5N1-infected patients were detected simultaneously and quantified separately by SRDFDS equipped with two emission filters. Results: Our results showed a high sensitivity of 92.86% (13/14) and 78.57% (11/14), and a specificity of 100% (38/38, P < 0.0001) and 97.37% (37/38) for influenza A and H5 subtype detection, respectively. Conclusion: Therefore, our multiplex QD bioconjugates and SRDFDS-based influenza virus detection toolkit potentially provide accurate and meaningful diagnosis information with improved detection accuracies and sensitivities for H5N1 patients.


Assuntos
Imunofluorescência/métodos , Vírus da Influenza A/fisiologia , Influenza Humana/diagnóstico , Smartphone/estatística & dados numéricos , Adolescente , Adulto , Animais , Aves , Criança , Pré-Escolar , Feminino , Imunofluorescência/instrumentação , Humanos , Virus da Influenza A Subtipo H5N1/fisiologia , Vírus da Influenza A/isolamento & purificação , Influenza Aviária/transmissão , Influenza Aviária/virologia , Influenza Humana/virologia , Masculino , Pontos Quânticos/química , Adulto Jovem
9.
Korean J Parasitol ; 55(4): 385-389, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28877569

RESUMO

Seroprevalence of Toxoplasma gondii infection among the residents of Cheorwon-gun, Gangwon-do, Korea, which partly includes the demilitarized zone (DMZ), were surveyed for 4 years and evaluated by RDT using recombinant fragment of major surface antigen (SAG1A). Sera from 1336, 583, 526, and 583 adult residents were collected on a yearly basis from 2010 to 2013, respectively. The total positive seroprevalence was 19.3, 21.9, 23.4, and 26.8% from 2010 to 2013, respectively. The positive seroprevalence in men (23.6, 27.5, 29.5, 34.6%) was far higher than women (14.1, 18.3, 19.4, 21.4%), from 2010 to 2013, respectively. This high seroprevalence of toxoplasmosis in Cheorwon-gun may have been influenced in part by its geographical locality of the area as it includes the DMZ, where civilian access is strictly limited, thus creating a relatively isolated area that is a well-preserved habitat. Further research is necessary to study the epidemiology of toxoplasmosis in this area.


Assuntos
Anticorpos Antiprotozoários/sangue , Testes Sorológicos/métodos , Toxoplasma/imunologia , Toxoplasmose/epidemiologia , Toxoplasmose/parasitologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos de Protozoários/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteínas de Protozoários/imunologia , Proteínas Recombinantes/imunologia , República da Coreia/epidemiologia , Estudos Soroepidemiológicos , Fatores Sexuais , Fatores de Tempo , Toxoplasmose/imunologia
10.
Sci Rep ; 7(1): 7933, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28801679

RESUMO

The development of a sensitive and rapid diagnostic test is needed for early detection of avian influenza (AI) H7 subtype. In this study, novel monoclonal antibodies (mAbs) against influenza A H7N9 recombinant hemagglutinin (rHA)1 were developed and applied to a Europium nanoparticle-based rapid fluorescent immunochromatographic strip test (FICT) to improve the sensitivity of the rapid diagnostic system. Two antibodies (2F4 and 6D7) exhibited H7 subtype specificity in a dot-FICT assay by optimization of the conjugate and the pH of the lysis buffer. The subtype specificity was confirmed by an immunofluorescence assay and Western blot analysis. The limit of detection of the FICT employing novel mAbs 31 ng/mL for H7N9 rHA1 and 40 hemagglutination units/mL for H7 subtype virus. Sensitivity was improved 25-fold using Europium as confirmed by comparison of colloidal gold-based rapid diagnostic kit using the 2F4 and 6D7 mAbs.


Assuntos
Anticorpos Monoclonais/imunologia , Európio/química , Glicoproteínas de Hemaglutininação de Vírus da Influenza/metabolismo , Subtipo H7N9 do Vírus da Influenza A/imunologia , Infecções por Orthomyxoviridae/diagnóstico , Animais , Anticorpos Monoclonais/química , Anticorpos Antivirais/química , Anticorpos Antivirais/imunologia , Cães , Fluorimunoensaio , Limite de Detecção , Células Madin Darby de Rim Canino , Nanopartículas Metálicas/química , Infecções por Orthomyxoviridae/imunologia , Kit de Reagentes para Diagnóstico , Proteínas Recombinantes/metabolismo , Sensibilidade e Especificidade
11.
Korean J Parasitol ; 55(3): 247-254, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28719949

RESUMO

ELISA has been used for the diagnosis of toxoplasmosis, but it is being gradually replaced by a rapid diagnostic test (RDT). We compared and analyzed ELISA and RDT results using the sera collected during 4 consecutive years from residents of Gyodong-do (Island), Incheon-city, Korea. Sera from 921, 993, 940, and 838 adult residents were collected on a yearly basis (2010-2013). ELISA was performed by using a crude extract of T. gondii RH strain antigen and IgG/IgM RDT mounted with recombinant fragment of major surface antigen (SAG1), GST-linker-SAG1A, were applied to the sera. Comparison between groups was analyzed by the Student's t-test. The positive seroprevalence surged from 14.7% (135/921, 2010), 23.1% (231/993, 2011), 23.6% (222/940, 2012), and 32.1% (269/838, 2013) by ELISA. In contrast, RDT showed a more moderate increasing trend from 21.7% (200/921, 2010), 25.5% (253/993, 2011), 28.9% (272/940, 2012) and 33.1% (277/838, 2013). Discrepancies between ELISA and RDT were noted near the cut-off value. At the OD 0.15-0.24 range, RDT could detect 16.1% (169/1051) more positives, which suggests an early or acute toxoplasmosis, but at the OD 0.25-0.34 range, ELISA could detect 35.9% (92/256) more positives of possible chronic infections. Over the OD > 0.35 ELISA and RDT agreed in the majority of the cases. This surge in seroprevalence may be caused by the organic agriculture in addition to eating behavior or increase in pets among Koreans. These facts may be applied on a full-scale national survey using RDT to supplement ELISA to define the characteristics of the infection.


Assuntos
Testes Diagnósticos de Rotina , Ensaio de Imunoadsorção Enzimática , Toxoplasmose/diagnóstico , Toxoplasmose/epidemiologia , Adulto , Animais , Antígenos de Protozoários , Comportamento Alimentar , Seguimentos , Humanos , Imunoglobulina G , Imunoglobulina M , Agricultura Orgânica/estatística & dados numéricos , Animais de Estimação/parasitologia , República da Coreia/epidemiologia , Estudos Soroepidemiológicos , Fatores de Tempo
12.
Theranostics ; 7(7): 1835-1846, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28638471

RESUMO

Currently, the point of care testing (POCT) is not fully developed for subtype-specific avian influenza virus detection. In this study, an H5N1 hemaglutinin 1 (HA1) epitope (P0: KPNDAINF) and three modified peptides (P1: KPNTAINF, P2: KPNGAINF, P3: KPNDAINDAINF) were evaluated as POCT elements for rapid detection of avian influenza virus. Based on modeling predictions by Autodock Vina, binding affinity varied depending on alteration of one amino acid in these peptides. The binding energy of P2 indicated its potential for a strong interaction with HA. Fluorescence-linked immunosorbent assay experimentally demonstrated the interaction between these peptides and virus. The four peptides interacted with HA1 of H5N3 with different binding affinities with P2 showing the strongest binding affinity. When P0 and P2 peptides were used in rapid fluorescent immunochromatographic test (FICT) as detection elements, the inter-assay coefficients of variation (CV) indicated that P2-linked FICT was more acceptable than the P0-linked FICT in the presence of human specimens. Antibody pair-linked FICT was influenced by clinical samples more than the P2-linked FICT assay, which showed a 4-fold improvement in the detection limit of H5N3 and maintained H5 subtype-specificity. Compared to the rapid diagnostic test (RDT) which is not specific for influenza subtypes, P2-linked FICT could increase virus detection. In conclusion, results of this study suggest that HA epitope-derived peptides can be used as alternatives to antibodies for a rapid fluorescent diagnostic assay to detect avian influenza virus.


Assuntos
Cromatografia de Afinidade/métodos , Testes Diagnósticos de Rotina/métodos , Influenza Aviária/diagnóstico , Orthomyxoviridae/isolamento & purificação , Animais , Aves , Epitopos/imunologia , Influenza Aviária/virologia , Orthomyxoviridae/imunologia , Peptídeos/metabolismo , Ligação Proteica , Coloração e Rotulagem/métodos , Fatores de Tempo
13.
Biosens Bioelectron ; 94: 677-685, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28390319

RESUMO

Sensitive and rapid diagnostic systems for avian influenza (AI) virus are required to screen large numbers of samples during a disease outbreak and to prevent the spread of infection. In this study, we employed a novel fluorescent dye for the rapid and sensitive recognition of AI virus. The styrylpyridine phosphor derivative was synthesized by adding allyl bromide as a stable linker and covalently immobilizing it on latex beads with antibodies generating the unique Red dye 53-based fluorescent probe. The performance of the innovative rapid fluorescent immnunochromatographic test (FICT) employing Red dye 53 in detecting the AI virus (A/H5N3) was 4-fold and 16-fold higher than that of Europium-based FICT and the rapid diagnostic test (RDT), respectively. In clinical studies, the presence of human nasopharyngeal specimens did not alter the performance of Red dye 53-linked FICT for the detection of H7N1 virus. Furthermore, in influenza A virus-infected human nasopharyngeal specimens, the sensitivity of the Red dye 53-based assay and RDT was 88.89% (8/9) and 55.56% (5/9) relative to rRT-PCR, respectively. The photostability of Red dye 53 was higher than that of fluorescein isothiocyanate (FITC), showing a stronger fluorescent signal persisting up to 8min under UV. The Red dye 53 could therefore be a potential probe for rapid fluorescent diagnostic systems that can recognize AI virus in clinical specimens.


Assuntos
Técnicas Biossensoriais/métodos , Vírus da Influenza A Subtipo H7N1/isolamento & purificação , Vírus da Influenza A/isolamento & purificação , Influenza Aviária/diagnóstico , Influenza Humana/diagnóstico , Animais , Galinhas , Surtos de Doenças , Corantes Fluorescentes , Humanos , Vírus da Influenza A Subtipo H7N1/patogenicidade , Vírus da Influenza A/patogenicidade , Influenza Aviária/virologia , Influenza Humana/virologia , Sensibilidade e Especificidade
14.
Korean J Parasitol ; 55(1): 9-13, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28285501

RESUMO

Seroprevalence of Toxoplasma gondii infection among the residents of Seokmo-do (Island) in Ganghwa-gun, Incheon, Korea was surveyed for 4 years by a rapid diagnostic test (RDT) using recombinant fragment of major surface antigen (SAG1), GST-linker-SAG1A. Sera from 312, 343, 390, and 362 adult residents were collected on a yearly basis from 2010 to 2013, respectively. Total positive seroprevalence regardless of gender was 29.2, 35.3, 38.7, and 45.3% from 2010 to 2013, respectively. Positive seroprevalence in male adults was 43.9, 48.2, 45.4, and 55.3%, which was far higher than that of the corresponding female adults which was 20.7, 29.2, 33.9, and 38.9%, from 2010 to 2013, respectively. This high seroprevalence of toxoplasmosis in Seokmo-do may have been caused in part by peculiar changes in the toxoplasmic environment of the island as it is a relatively isolated area preserving its natural habitat while also being connected by a bridge to the mainland. Further study is necessary to find out symptomatic patients and to confirm the risk factors.


Assuntos
Anticorpos Antiprotozoários/sangue , Cromatografia de Afinidade/métodos , Toxoplasma/imunologia , Toxoplasmose/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cidades/epidemiologia , Feminino , Humanos , Ilhas/epidemiologia , Coreia (Geográfico)/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Soroepidemiológicos , Inquéritos e Questionários
15.
Int J Biol Sci ; 12(7): 824-35, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27313496

RESUMO

Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.


Assuntos
Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Antígenos de Protozoários/imunologia , Malária/metabolismo , Malária/transmissão , Malária Falciparum/diagnóstico , Malária Falciparum/metabolismo , Malária Falciparum/transmissão , Malária Vivax/diagnóstico , Malária Vivax/metabolismo , Malária Vivax/transmissão , Proteína 1 de Superfície de Merozoito/metabolismo , Reação Transfusional
16.
Korean J Parasitol ; 54(2): 239-41, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27180586

RESUMO

Chikungunya virus (CHIKV), a tropical pathogen, has re-emerged and has massive outbreaks abruptly all over the world. Containing many dominant epitopes, the envelope E2 protein of CHIKV has been explored for the vaccination or diagnosis. In the present study, the antigenicity of a recombinant expressed intrinsically disorder domain (IUD) of E2 was tested for the detection of the antibody against CHIKV through western blot method. The gene of the IUD of E2 was inserted into 2 different vectors and expressed as recombinant GST-E2 and recombinant MBP-E2 fusion protein, respectively. Two kinds of fusion proteins were tested with 30 CHIKV patient sera and 30 normal sera, respectively. Both proteins were detected by 25 patients sera (83.3%) and 1 normal serum (3.3%). This test showed a relatively high sensitivity and very high specificity of the recombinant E2 proteins to be used as diagnostic antigens against CHIKV infection.


Assuntos
Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/imunologia , Proteínas Recombinantes de Fusão/imunologia , Proteínas do Envelope Viral/imunologia , Febre de Chikungunya/virologia , Epitopos/imunologia , Glutationa Transferase/genética , Glutationa Transferase/imunologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Proteínas Ligantes de Maltose/genética , Proteínas Ligantes de Maltose/imunologia
17.
Theranostics ; 6(2): 231-42, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26877781

RESUMO

Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflective light collection module using a coumarin-derived dendrimer-based fluorescent lateral flow immunoassay. By application of an optimized bioconjugate, a smartphone-based diagnostic device had a two-fold higher detectability as compared to that of the table-top fluorescence strip reader for three different AI subtypes (H5N3, H7N1, and H9N2). Additionally, in a clinical study of H5N1-confirmed patients, the smartphone-based diagnostic device showed a sensitivity of 96.55% (28/29) [95% confidence interval (CI): 82.24 to 99.91] and a specificity of 98.55% (68/69) (95% CI: 92.19 to 99.96). The measurement results from the distributed individual smartphones were wirelessly transmitted via short messaging service and collected by a centralized database system for further information processing and data mining. Smartphone-based diagnosis provided highly sensitive measurement results for H5N1 detection within 15 minutes. Because of its high sensitivity, portability and automatic reporting feature, the proposed device will enable agile identification of patients and efficient control of AI dissemination.


Assuntos
Triagem e Testes Direto ao Consumidor/métodos , Influenza Humana/diagnóstico , Imagem Óptica/instrumentação , Smartphone , Telemedicina/instrumentação , Adolescente , Criança , Pré-Escolar , Cumarínicos , Dendrímeros , Feminino , Corantes Fluorescentes , Humanos , Imunoensaio , Lactente , Virus da Influenza A Subtipo H5N1 , Masculino , Imagem Óptica/métodos , Sensibilidade e Especificidade , Telemedicina/métodos
18.
Sci Rep ; 5: 18077, 2015 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-26655854

RESUMO

High levels of anti-dengue IgM or IgG can be detected using numerous rapid diagnostic tests (RDTs). However, the sensitivity and specificity of these tests are reduced by changes in envelope glycoprotein antigenicity that inevitably occur in limited expression systems. A novel RDT was designed to enhance diagnostic sensitivity. Dengue viruses cultured in animal cells were used as antigens to retain the native viral coat protein. Monoclonal antibodies (mAbs) were then developed, for the first time, against domain I of envelope glycoprotein (EDI). The anti-dengue EDI mAb was employed as a capturer, and EDII and EDIII, which are mainly involved in the induction of neutralizing antibodies in patients, were fully available to bind to anti-dengue IgM or IgG in patients. A one-way automatic blood separation device prevented reverse migration of plasma and maximize the capture of anti-dengue antibodies at the test lines. A clinical evaluation in the field proved that the novel RDT (sensitivities of 96.5% and 96.7% for anti-dengue IgM and IgG) is more effective in detecting anti-dengue antibodies than two major commercial tests (sensitivities of 54.8% and 82% for SD BIOLINE; 50.4% and 75.3% for PanBio). The innovative format of RDT can be applied to other infectious viral diseases.


Assuntos
Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/imunologia , Antígenos Virais/imunologia , Vírus da Dengue/imunologia , Dengue/imunologia , Testes Diagnósticos de Rotina/métodos , Animais , Chlorocebus aethiops , Reações Cruzadas/imunologia , Dengue/diagnóstico , Dengue/virologia , Vírus da Dengue/fisiologia , Testes Diagnósticos de Rotina/instrumentação , Feminino , Interações Hospedeiro-Patógeno/imunologia , Humanos , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Células Vero
19.
Diagn Microbiol Infect Dis ; 82(2): 128-34, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25824725

RESUMO

Early diagnosis of dengue virus (DENV) is important. There are numerous products on the market claiming to detect DENV NS1, but these are not always reliable. In this study, a highly sensitive and accurate rapid diagnostic test (RDT) was developed using anti-dengue NS1 monoclonal antibodies. A recombinant NS1 protein was produced with high antigenicity and purity. Monoclonal antibodies were raised against this purified NS1 antigen. The RDT was constructed using a capturing (4A6A10, Kd=7.512±0.419×10(-9)) and a conjugating antibody (3E12E6, Kd=7.032±0.322×10(-9)). The diagnostic performance was evaluated with NS1-positive clinical samples collected from various dengue endemic countries and compared to SD BioLine Dengue NS1 Ag kit. The constructed RDT exhibited higher sensitivity (92.9%) with more obvious diagnostic performance than the commercial kit (83.3%). The specificity of constructed RDT was 100%. The constructed RDT could offer a reliable point-of-care testing tool for the early detection of dengue infections in remote areas and contribute to the control of dengue-related diseases.


Assuntos
Dengue/diagnóstico , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Proteínas não Estruturais Virais/sangue , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/isolamento & purificação , Anticorpos Antivirais/imunologia , Anticorpos Antivirais/isolamento & purificação , Diagnóstico Precoce , Humanos , Sensibilidade e Especificidade , Fatores de Tempo
20.
J Clin Virol ; 65: 11-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25766980

RESUMO

BACKGROUND: Dengue is a mosquito-borne disease that causes a public health problem in tropical and subtropical countries. Current immunological diagnostics based on IgM and/or nonstructural protein 1 (NS1) antigen are limited for acute dengue infection due to low sensitivity and accuracy. OBJECTIVES: This study aimed to develop a one-step multiplex real-time RT-PCR assay showing higher sensitivity and accuracy than previous approaches. STUDY DESIGN: Serotype-specific primers and probes were designed through the multiple alignment of NS1 gene. The linearity and limit of detection (LOD) of the assay were determined. The assay was clinically validated with an evaluation panel that was immunologically tested by WHO and Malaysian specimens. RESULTS: The LOD of the assay was 3.0 log10 RNA copies for DENV-1, 2.0 for DENV-3, and 1.0 for DENV-2 and DENV-4. The assay showed 95.2% sensitivity (20/21) in an evaluation panel, whereas NS1 antigen- and anti-dengue IgM-based immunological assays exhibited 0% and 23.8-47.6% sensitivities, respectively. The assay showed 100% sensitivity both in NS1 antigen- and anti-dengue IgM-positive Malaysian specimens (26/26). The assay provided the information of viral loads and serotype with discrimination of heterotypic mixed infection. CONCLUSIONS: The assay could be clinically applied to early dengue diagnosis, especially during the first 5 days of illness and approximately 14 days after infection showing an anti-dengue IgM-positive response.


Assuntos
Dengue/diagnóstico , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Proteínas não Estruturais Virais/genética , Diagnóstico Precoce , Humanos , Limite de Detecção , Sensibilidade e Especificidade , Testes Sorológicos , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA