Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36772458

RESUMO

A low-loss, compact, ultra-thin, passive, 77 GHz, 8 × 8 microstrip Butler matrix on a 200 µm thick high-purity fused-silica (HPFS) glass substrate embedded in 0.8 µm thick patterned gold conducting layers was developed for low power automotive radars. The first-of-its-kind, HPFS, glass-based Butler matrix comprised 12 hybrid couplers, 16 crossovers, and 8 phase shifters in a footprint area of 19.1 mm × 26.6 mm. The device and the corresponding building blocks were designed and optimized using 3D electromagnetic finite element method (FEM) simulations using the Advanced Design System (ADS) from Keysight™ Technologies. Due to the very-low-loss tangent of the HPFS glass substrate (0.0005 @77 GHz) compared to other common substrate materials and rigorous design optimization, the return loss and isolation of the input ports are both below -20 dB, respectively, as verified by 3D FEM simulations. Due to the absence of any published data on a 77 GHz 8 × 8 Butler matrix, the design was validated by developing a 4 × 4 version of the Butler matrix using the same building blocks and comparing the 3D simulation results in ADS with results published elsewhere that showed that the developed Butler matrix offers lower insertion loss in a 10% smaller footprint area. A low-cost microfabrication method has been developed to fabricate the devices using a standard lift-off process. A scaled version of the device can be used for 5G beamforming applications.

2.
Sensors (Basel) ; 21(11)2021 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-34204884

RESUMO

The design of a microelectromechanical systems (MEMS) ultra-wideband (UWB) RMS power sensor is presented. The sensor incorporates a microfabricated Fe-Co-B core planar inductor and a microfabricated vibrating diaphragm variable capacitor on adhesively bonded glass wafers in a footprint area of 970 × 970 µm2 to operate in the 3.1-10.6 GHz UWB frequency range. When exposed to a far-field UWB electromagnetic radiation, the planar inductor acts as a loop antenna to generate a frequency-independent voltage across the MEMS capacitor. The voltage generates a coulombic attraction force between the diaphragm and backplate that deforms the diaphragm to change the capacitance. The frequency-independent capacitance change is sensed using a transimpedance amplifier to generate an output voltage. The sensor exhibits a linear capacitance change induced voltage relation and a calculated sensitivity of 4.5 aF/0.8 µA/m. The sensor can be used as a standalone UWB power sensor or as a 2D array for microwave-based biomedical diagnostic imaging applications or for non-contact material characterization. The device can easily be tailored for power sensing in other application areas such as, 5G, WiFi, and Internet-of-Things (IoT). The foreseen fabrication technique can rely on standard readily available microfabrication techniques.

3.
Sensors (Basel) ; 21(4)2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33669794

RESUMO

This paper presents a novel technique to reduce acoustic crosstalk in capacitive micromachined ultrasonic transducer (CMUT) arrays. The technique involves fabricating a thin layer of diisocyanate enhanced silica aerogel on the top surface of a CMUT array. The silica aerogel layer introduces a highly nanoporous permeable layer to reduce the intensity of the Scholte wave at the CMUT-fluid interface. 3D finite element analysis (FEA) simulation in COMSOL shows that the developed technique can provide a 31.5% improvement in crosstalk reduction for the first neighboring element in a 7.5 MHz CMUT array. The average improvement of crosstalk level over the -6 dB fractional bandwidth was 22.1%, which is approximately 5 dB lower than that without an aerogel layer. The results are in excellent agreement with published experimental results to validate the efficacy of the new technique.

4.
Sensors (Basel) ; 16(7)2016 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-27347955

RESUMO

Experimental measurement results of a 1.75 mm × 1.75 mm footprint area Capacitive Micromachined Ultrasonic Transducer (CMUT) planar array fabricated using a bisbenzocyclobutene (BCB)-based adhesive wafer bonding technique has been presented. The array consists of 40 × 40 square diaphragm CMUT cells with a cavity thickness of 900 nm and supported by 10 µm wide dielectric spacers patterned on a thin layer of BCB. A 150 µm wide one µm thick gold strip has been used as the contact pad for gold wire bonding. The measured resonant frequency of 19.3 MHz using a Polytec™ laser Doppler vibrometer (Polytec™ MSA-500) is in excellent agreement with the 3-D FEA simulation result using IntelliSuite™. An Agilent ENA5061B vector network analyzer (VNA) has been used for impedance measurement and the resonance and anti-resonance values from the imaginary impedance curve were used to determine the electromechanical coupling co-efficient. The measured coupling coefficient of 0.294 at 20 V DC bias exhibits 40% higher transduction efficiency as compared to a measured value published elsewhere for a silicon nitride based CMUT. A white light interferometry method was used to measure the diaphragm deflection profiles at different DC bias. The diaphragm center velocity was measured for different sub-resonant frequencies using a Polytec™ laser Doppler vibrometer that confirms vibration of the diaphragm at different excitation frequencies and bias voltages. Transmit and receive operations of CMUT cells were characterized using a pitch-catch method and a -6 dB fractional bandwidth of 23% was extracted from the received signal in frequency domain. From the measurement, it appears that BCB-based CMUTs offer superior transduction efficiency as compared to silicon nitride or silicon dioxide insulator-based CMUTs, and provide a very uniform deflection profile thus making them a suitable candidate to fabricate highly energy efficient CMUTs.

5.
Artigo em Inglês | MEDLINE | ID: mdl-23549544

RESUMO

A highly accurate mathematical method has been presented for analytical characterization of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The method uses a new two-dimensional polynomial function to more accurately predict the deflection curve of a multilayer square diaphragm subject to both mechanical and electrostatic pressure and a new capacitance model that takes into account the contribution of the fringing field capacitances. Both of the models have been experimentally verified by comparing the models predicted values with measurement results and are found to be in excellent agreement with a maximum deviation of less than 2% for experimentally measured capacitance values. 3-D electromechanical finite element analysis (FEA) for a wide range of material properties, geometric specifications, and loading conditions show that the presented method is highly consistent in accuracy over the typical square-diaphragm CMUT design space.

6.
Artigo em Inglês | MEDLINE | ID: mdl-18599424

RESUMO

Design of a discretized hyperbolic paraboloid geometry beamforming array of capacitive micromachined ultrasonic transducers (CMUT) has been presented. The array can intrinsically provide a broadband constant beamwidth beamforming capability without any microelectronic signal processing. A mathematical model has been developed and verified to characterize the array response. A design methodology has been presented that enables determination of the array's physical dimensions and CMUT modeling in a straightforward manner. Developed methodology has been used to design two discretized hyperbolic paraboloid geometry beamforming CMUT arrays: one in the 2.3 MHz to 5.2 MHz frequency range and another in the 113 kHz to 167 kHz frequency range. CMUTs have been designed using a cross-verification method that involves lumped element modeling, 3-D electromechanical finite element analysis (FEA), and microfabrication simulation. The developed array has the potential to be used in real-time automotive collision-avoidance applications, medical diagnostic imaging and therapeutic applications, and industrial sensing.


Assuntos
Desenho Assistido por Computador , Aumento da Imagem/instrumentação , Análise em Microsséries/instrumentação , Transdutores , Ultrassonografia/instrumentação , Desenho de Equipamento , Análise em Microsséries/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA