Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Neurol ; 266(9): 2197-2207, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31152296

RESUMO

Tinnitus, the perception of sound in the absence of external stimuli, is often a disturbing symptom for which the underlying functional neuroanatomy still remains poorly understood. Most studies have focused solely on functional connectivity changes in the auditory cortex of tinnitus patients. The aim of this study was to investigate whether a correlation exists between tinnitus behavioural scores and functional brain connectivity of five resting-state networks comprising the auditory, the default mode, the external control left and right, and the salience network. For this purpose, a large sample of one hundred and thirty-five subjects underwent resting-state functional magnetic resonance imaging and their behavioural scores were obtained using clinical evaluations. Networks were extracted using independent component analysis, and functional connectivity patterns in the extracted networks were evaluated by a graph theoretical approach. The effects of tinnitus for each network were investigated by correlating the graph strength of all the regions with the tinnitus behavioural scores using stepwise fit regression analysis. Results indicated that alterations of functional interactions between key neural circuits of the brain are not limited to one single network. In particular, tinnitus distress showed a strong correlation with the connectivity pattern within and between the right executive control network and the other four resting-state networks, indicating that tinnitus distress is probably the consequence of a hyperactive attention condition. Among the behavioural scores, the strongest correlation was observed between age and hearing loss, while the tinnitus objective loudness was not correlated with any behavioural scores.


Assuntos
Estimulação Acústica/métodos , Atenção/fisiologia , Encéfalo/diagnóstico por imagem , Rede Nervosa/diagnóstico por imagem , Zumbido/diagnóstico por imagem , Adulto , Idoso , Feminino , Testes Auditivos/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Zumbido/fisiopatologia
2.
Phys Med Biol ; 58(12): 4367-79, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23739174

RESUMO

The time-varying magnetic fields created by the gradient coils in magnetic resonance imaging can produce negative effects on image quality and the system itself. Additionally, they can be a limiting factor to the introduction of non-MR devices such as cardiac pacemakers, orthopedic implants, and surgical robotics. The ability to model the induced currents produced by the switching gradient fields is key to developing methods for reducing these unwanted interactions. In this work, a framework for the calculation of induced currents on conducting surface geometries is summarized. This procedure is then compared to two separate experiments: (1) the analysis of the decay of currents induced upon a conducting cylinder by an insert gradient set within a head only 7 T MR scanner; and (2) analysis of the heat deposited into a small conductor by a uniform switching magnetic field at multiple frequencies and two distinct conductor thicknesses. The method was shown to allow the accurate modeling of the induced time-varying field decay in the first case, and was able to provide accurate estimation of the rise in temperature in the second experiment to within 30% when the skin depth was greater than or equal to the thickness of the conductor.


Assuntos
Simulação por Computador , Condutividade Elétrica , Imageamento por Ressonância Magnética/instrumentação , Algoritmos
3.
IEEE Trans Med Imaging ; 27(1): 75-86, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18270064

RESUMO

Prepolarized magnetic resonance imaging (PMRI) uses two pulsed electromagnets to achieve high-field image quality with the benefits of low-field data acquisition. The principal challenge with all resistive MRI systems is the implementation of a highly precise magnet current supply. The noise current through the magnet is fundamentally limited by the current transducer used to provide feedback and the voltage reference used to generate the demand signal. Field instability in the main field magnet can both corrupt the received data and degrade the robustness of Carr¿Purcell¿Meiboom¿Gill (CPMG) echo trains, which are paramount to efficient imaging in PMRI. In this work, we present the magnet control system that achieved sufficient field stability for PMRI at $0.5/0.13$ T, identify the dominant sources of noise in the control system, examine the imaging artifacts that can occur if the field stability is insufficient, and identify how the design can be improved for better field stability, should it be required for future implementations of PMRI.


Assuntos
Fontes de Energia Elétrica , Fenômenos Eletromagnéticos/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Med Biol ; 51(11): 2825-41, 2006 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-16723769

RESUMO

This paper presents a design study for a field-cycled magnetic resonance imaging (MRI) system directed at small animal imaging applications. A field-cycled MRI system is different from a conventional MRI system in that it uses two separate and dynamically controllable magnetic fields. A strong magnetic field is used to polarize the object, and a relatively weak magnetic field is used during signal acquisition. The potential benefits of field-cycled MRI are described. The theoretical dependences of field-cycled MRI performance on system design are introduced and investigated. Electromagnetic, mechanical and thermal performances of the system were considered in this design study. A system design for imaging 10 cm diameter objects is presented as an example, capable of producing high-duty-cycle polarizing magnetic fields of 0.5 T and readout magnetic fields corresponding to a proton Larmor frequency of 5 MHz. The specifications of the final design are presented along with its expected electromagnetic and thermal performance.


Assuntos
Campos Eletromagnéticos , Aumento da Imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Algoritmos , Animais , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Modelos Animais , Sensibilidade e Especificidade , Estresse Mecânico , Temperatura , Fatores de Tempo
5.
Magn Reson Med ; 46(2): 386-94, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11477644

RESUMO

Gradient coil magnetostimulation thresholds were measured in a group of 20 volunteers in both a whole-body gradient coil and a head/neck gradient coil. Both coils were operated using both x and y axes simultaneously (xy oblique mode). The waveform applied was a 64-lobe trapezoidal train with 1-ms flat-tops and varying rise times. Thresholds were based on the subjects' perception of stimulation, and painful sensations were not elicited. Thresholds were expressed in terms of the total gradient excursion required to cause stimulation as a function of the duration of the excursion. Thresholds for each subject were fit to a linear model, and values for the threshold curve slope (SR(min)) and vertical axis intercept (DeltaG(min)) were extracted. For the body coil, the mean values were: SR(min) = 62.2 mT/m/ms, DeltaG(min) = 44.4 mT/m. For the head/neck coil, the mean values were: SR(min) = 87.3 mT/m/ms, DeltaG(min) = 78.9 mT/m. These curve parameters were combined with calculated values for the induced electric field as a function of position within the coil to yield the tissue specific parameters E(r) (electric field rheobase) and tau(c) (chronaxie). For tissue stimulated within the body coil, the mean values were: E(r) = 1.8 V/m, tau(c) = 770 micros. For tissue stimulated within the head/neck coil, the mean values were: E(r) = 1.3 V/m, tau(c) = 1100 micros. Scalar potential contributions were not included in the calculation of induced electric fields. The mean threshold curves were combined with the gradient system performance curves to produce operational limit curves. The operational limit curves for the head/neck coil system were verified to be higher than those of the whole-body coil; however, the head/neck system was also found to be physiologically limited over a greater range of its operation than was the body coil. Subject thresholds between the two coils were not well correlated.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Sensação/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Limiar da Dor/fisiologia
6.
Magn Reson Med ; 45(5): 916-9, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11323819

RESUMO

A simple linear formulation for magnetostimulation thresholds specific to MRI gradient coils is derived based on established hyperbolic electrostimulation strength vs. duration relations. Thresholds are derived in terms of the gradient excursion required to cause stimulation, and it is demonstrated that the threshold curve is a linear function of the gradient switching time. A parameter beta is introduced as being fundamental in the evaluation of gradient coil stimulation. beta is a map of the induced electric field per unit gradient slew rate, and can be calculated directly from the gradient coil wire pattern. Consideration of beta alone is sufficient to compare stimulation thresholds between different gradient coil designs, as well as to evaluate the expected dependency of stimulation threshold on position within the gradient coil. The linear gradient threshold curve is characterized by two parameters: SR(min) and DeltaG(min). SR(min) is the slope of the threshold curve and represents the minimum slew rate required to cause stimulation in the limit of infinite gradient strength. DeltaG(min) is the vertical axis intercept of the curve and represents the minimum gradient excursion required to cause stimulation in the limit of infinite slew rate. Both SR(min) and DeltaG(min) are functions of both beta and the standard tissue parameters E(r) (rheobase) and tau(c) (chronaxie time). The ease with which both the gradient system performance and the stimulation thresholds can be plotted on the same axes is noted and is used to introduce the concept of a piece-wise linear operational limit curve for a gradient system.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Estimulação Elétrica , Campos Eletromagnéticos , Humanos , Magnetismo , Matemática , Nervos Periféricos/fisiologia
7.
Magn Reson Med ; 44(6): 955-63, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11108634

RESUMO

The design, fabrication, and testing of a complete three-axis gradient coil capable of imaging the human neck is described. The analytic method of constrained current minimum inductance (CCMI) was used to position the uniform region of the gradient coil adjacent to and extending beyond the physical edge of the coil. The average gradient efficiency of the three balanced axes is 0.37 mT/m/A and the average inductance is 827 microH. With maximum amplifier current of 200A and receive signal sweep width of +/-125 kHz, the average minimum FOV using this gradient set is 7.9 cm. The completed coil has an inner diameter of 32 cm, an outer diameter of 42 cm, and a length (including cabling connections) of 80 cm. The entire coil was built in-house. The structure is actively water cooled. Heating measurements were made to characterize the thermal response of the coil under various operating conditions and it was determined that a continuous current of 100A could be passed through all three axes simultaneously without increasing the internal coil temperature by more than 23 degrees C. Eddy current measurements were made for all axes. With digital compensation, the gradient eddy current components could be adequately compensated. A large B(o) eddy current field is produced by the Gz axis that could be corrected through the use of an auxiliary B(o) compensation coil. Preliminary imaging results are shown in both phantoms and human subjects.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Encéfalo/anatomia & histologia , Desenho de Equipamento , Cabeça , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Pescoço
8.
Magn Reson Med ; 44(4): 532-6, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11025508

RESUMO

Both the acoustic and magnetic fluctuation frequency response functions for a Siemens AS25 body gradient coil inside a 4 Tesla whole-body MR system were measured and analyzed in this study. In an attempt to correlate the acoustic noise inside the gradient coil with magnetic field oscillations, triangular and trapezoidal gradient impulses of varying amplitudes and widths were used to excite the gradient coil. The acoustic and magnetic responses to these inputs were measured. The results show the existence of discrete resonances in both acoustic and uniform magnetic field fluctuation spectra, while gradient magnetic field fluctuation spectra show no such resonances. In addition, the dominant amplitude peaks in spectra fluctuate similarly with respect to trapezoidal gradient impulse flat-top widths. This implies that these phenomena are correlated, and that the trapezoidal impulse flat-top width may be used as a way to suppress both acoustic noise and uniform magnetic field oscillations.


Assuntos
Imageamento por Ressonância Magnética , Campos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Ruído
9.
MAGMA ; 10(2): 131-46, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10873203

RESUMO

There is great interest in the non-destructive capabilities of magnetic resonance microscopy for studying murine models of both disease and normal function; however, these studies place extreme demands on the MR hardware, most notably the gradient field system. We designed, using constrained current minimum inductance methods, and fabricated a complete, unshielded three-axis gradient coil set that utilizes interleaved, multilayer axes to achieve maximum gradient strengths of over 2000 mT m(-1) in rise times of less than 50 micros with an inner coil diameter of 5 cm. The coil was wire-wound using a rectangular wire that minimizes the deposited power for a given gradient efficiency. Water cooling was also incorporated into the coil to assist in thermal management. The duty cycle for the most extreme cases of single shot echo planar imaging (EPI) is limited by the thermal response and expressions for maximum rates of image collection are given for burst and continuous modes of operation. The final coil is capable of the collection of single shot EPI images with 6 mm field of view and 94 microm isotropic voxels at imaging rates exceeding 50 s(-1).


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Microscopia/instrumentação , Animais , Fenômenos Biofísicos , Biofísica , Encéfalo/anatomia & histologia , Impedância Elétrica , Desenho de Equipamento , Estudos de Avaliação como Assunto , Temperatura Alta , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Camundongos , Microscopia/métodos , Microscopia/estatística & dados numéricos , Modelos Teóricos , Imagens de Fantasmas
10.
Magn Reson Med ; 39(3): 392-401, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9498595

RESUMO

A high-strength three-axis local gradient coil set was constructed for MRI of the breast. Gradient fields with good uniformity (<10% deviation from the desired gradient) over most of the volume required for breast imaging were generated with efficiencies of up to 3.3 mT/m/A. The coils will allow diffusion breast imaging in clinically acceptable examination times. The electrical design, water cooling system, and fabrication techniques are described. Preliminary tests of the coil included images of a grid phantom and diffusion measurements in a short-T2 agarose gel phantom.


Assuntos
Mama/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Artefatos , Eletricidade , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Fatores de Tempo , Água
11.
Magn Reson Med ; 39(2): 270-8, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9469710

RESUMO

A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constraints on the final current density is presented. This constrained current minimum inductance method is derived in the context of previous target field methods. Complete details are shown and all equations required for implementation of the algorithm are given. The method has been implemented on computer and applied to the design of both a 1:1 aspect ratio (length:diameter) central ROI and a 2:1 aspect ratio edge ROI gradient coil. The 1:1 design demonstrates that a general analytic method can be used to easily obtain very short gradient coil designs for use with specialized magnet systems. The edge gradient design demonstrates that designs that allow imaging of the neck region with a head sized gradient coil can be obtained, as well as other applications requiring edge-of-cylinder regions of uniformity.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Humanos , Espectroscopia de Ressonância Magnética/instrumentação
12.
Magn Reson Med ; 34(4): 604-11, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8524029

RESUMO

The authors describe a new gradient coil design for high resolution human, animal, specimen, or phantom imaging with high gradient efficiency and a large region of excellent gradient uniformity. Important features of our new design are the simple analytical description of the wire patterns that comprise the design, and ease of construction. Wires are spaced in a sinusoidal distribution around the circumference of the cylinder, and curved in an arcsin shape along the length of the cylinder. This coil produces a magnetic field pointing in a direction transverse to the axis of the coil with a gradient in the direction parallel to the axis of the coil. The same arcsin coil can be used to create a magnetic field pointing in a direction parallel to its axis with a gradient in a direction perpendicular to the coil axis. A prototype coil was constructed; field and inductance calculations were verified. Geometric variations on this coil design were modeled and their performance characteristics compared. This coil design is ideal for rapid implementation of a transverse gradient coil, since no specialized design software is required.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Algoritmos , Animais , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Modelos Estruturais , Software , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA