1.
J Appl Clin Med Phys ; 25(3): e14291, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38306504

RESUMO

PURPOSE: To present a modified calibration method to reduce signal drift due to table sagging in Respiratory Gating for Scanner (RGSC) systems with a wall-mounted camera. MATERIALS AND METHODS: Approximately 70 kg of solid water phantoms were evenly distributed on the CT couch, mimicking the patient's weight. New calibration measurements were performed at 9 points at the combination of three lateral positions, the CT isocenter and ±10 cm laterally from the isocenter, and three longitudinal locations, the CT isocenter and ±30 cm or ±40 cm from the isocenter. The new calibration was tested in two hospitals. RESULTS: Implementing the new weighed calibration method at the extended distance yielded improved results during the DIBH scan, reducing the drift to within 1 from 3 mm. The extended calibration positions exhibited similarly reduced drift in both hospitals, reinforcing the method's robustness and its potential applicability across all centers. CONCLUSION: This proposed solution aims to minimize the systematic error in radiation delivery for patients undergoing motion management with wall-mounted camera RGSC systems, especially in conjunction with a bariatric CT couchtop.


Assuntos
Aceleradores de Partículas , Humanos , Imagens de Fantasmas , Movimento (Física)
2.
Adv Radiat Oncol ; 8(6): 101289, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37457824

RESUMO

Purpose: Purpose: Subtotal skin electron beam therapy may be an option for patients with cutaneous lymphoma receiving radiation therapy to treat large areas of their skin but may benefit from sparing specific areas that may have had previous radiation therapy, are of specific cosmetic concern, and/or show no evidence of disease. We report here on the design, implementation, and dosimetric characteristics of a reusable and transparent customizable shield for use with the large fields used to deliver total skin electron beam therapy at extended distance with a conventional linear accelerator. Methods and Materials: A shield was designed and manufactured consisting of acrylic blocks that can be mounted on a steel frame to allow patient-specific shielding. The dosimetry of the device was measured using radiochromic film. Results: The shield is easy to use and well-tolerated for patient treatment, providing minimal electron transmission through the shield with a sharp penumbra at the field edge, with no increase in x-ray dose. We report on the dosimetry of a commercial device that has been used to treat more than 30 patients to date. Conclusions: The customizable shield is well suited to providing patient-specific shielding for subtotal skin electron beam therapy.

3.
Pract Radiat Oncol ; 12(5): e453-e459, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35272078

RESUMO

PURPOSE: A successful proton beam therapy (PBT) center relies heavily on the proper function and maintenance of a proton beam therapy machine. However, when a PBT machine is non-operational, a proton facility is hindered with delays that can potentially lead to inferior treatment outcome due to treatment interruption. This article reports a viable solution for a photon back-up plan in a proton down event. METHODS AND MATERIALS: The implementation of a workflow for which proton plans are converted to photon plans so that patients can be treated using photons has been a successful strategy to reduce delays and mitigate its effect on patient care. This workflow was established through collaboration of physicians, physicists, dosimetrists, therapists, nurses, and schedulers. RESULTS AND CONCLUSIONS: A tiered system established by disease site, number of fractions, and individualized circumstances is used to prioritize patients. Proton-photon backup planning strategy and physics check details were described. This article provides an overview of workflow of conversion of PBT to photon when the PBT machine is down. Specific needs of patients undergoing proton beam therapy are addressed.


Assuntos
Terapia com Prótons , Humanos , Fótons/uso terapêutico , Terapia com Prótons/métodos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho
4.
Int J Radiat Oncol Biol Phys ; 53(5): 1130-8, 2002 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-12128112

RESUMO

PURPOSE: Transabdominal ultrasound localization of the prostate gland and its immediate surrounding anatomy has been used to guide the positioning of patients for the treatment of prostate cancer. This process was evaluated in terms of (1) the reproducibility of the ultrasound measurement; (2) a comparison of patient position between ultrasound localization and skin marks determined from a CT treatment planning scan; (3) the predictive indicators of patient anatomy not well suited for ultrasound localization; (4) the measurement of prostate organ displacement resulting from ultrasound probe pressure; and (5) quality assurance measures. METHODS AND MATERIALS: The reproducibility of the ultrasound positioning process was evaluated for same-day repeat positioning by the same ultrasound operator (22 patients) and for measurements made by 2 different operators (38 patients). Differences between conventional patient positioning (CT localization with skin markings) and ultrasound-based positioning were determined for 38 patients. The pelvic anatomy was evaluated for 34 patients with pretreatment CT scans to identify predictors of poor ultrasound image quality. The displacement of the prostate resulting from pressure of the ultrasound probe was measured for 16 patients with duplicate CT scans with and without a simulated probe. Finally, daily, monthly, and semiannual quality assurance tests were evaluated. RESULTS: Self-verification tests of ultrasound positioning indicated a shift of <3 mm in approximately 95% of cases. Interoperator tests indicated shifts of <3 mm in approximately 80-90% of cases. The mean difference in patient positioning between conventional and ultrasound localization for lateral shifts was 0.3 mm (SD 2.5): vertical, 1.3 mm (SD 4.7 mm) and longitudinal, 1.0 mm (SD 5.1). However, on a single day, the differences were >10 mm in 1.5% of lateral shifts, 7% of longitudinal shifts, and 7% of vertical shifts. The depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis, but not the bladder volume, were significant predictive indicators of poor ultrasound imaging. The pressure of the ultrasound probe displaced the prostate in 7 of the 16 patients by an average distance of 3.1 mm; 9 patients (56%) showed no displacement. Finally, the quality assurance tests detected ultrasound equipment defects. CONCLUSION: The ultrasound positioning system is reproducible and may indicate the need for significant positioning moves. Factors that predict poor image quality are the depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis. The prostate gland may be displaced a small amount by the pressure of the ultrasound probe. A quality assurance program is necessary to detect ultrasound equipment defects that could result in patient alignment errors.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Humanos , Masculino , Movimento , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Fatores de Tempo