Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Glaucoma ; 31(7): 567-573, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35353776

RESUMO

PRCIS: The Laguna ONhE, a software that measures the hemoglobin (Hb) concentration of the optic nerve head (ONH) from fundus photographs, demonstrated good accuracy in discriminating healthy eyes from eyes with mild glaucoma. PURPOSE: The aim was to evaluate Hb concentration of the optic nerve to distinguish between healthy eyes and eyes with mild glaucoma. METHODS: Eyes from patients with mild primary open angle glaucoma (MD > -6 dB) (n=58) and from healthy subjects (n=64) were selected. Retinal nerve fiber layer thickness measurements of all eyes were acquired with optical coherence tomography. Optic disc photographs were also obtained, and the images were analyzed using the Laguna ONhE software, which measures the amount of Hb in 24 sectors of the ONH. The software also calculates the Glaucoma Discriminant Function (GDF), an index that expresses the chance of the ONH being compatible with glaucoma. Areas under the receiver operating characteristic curve and sensitivities at fixed specificities of 90% and 95% of each Laguna ONhE parameter were calculated. RESULTS: The mean retinal nerve fiber layer thickness and vertical cup/disc ratio of the control and glaucoma groups were 90.0±10.6 µm versus 66.28±9.85 µm ( P <0.001) and 0.5±0.09 versus 0.65±0.09 ( P <0.001), respectively. Total Hb (67.9±4.45 vs. 62.89±4.89, P <0.001) and GDF (11.57±15.34 vs. -27.67±20.94, P <0.001) were significantly higher in the control group. The Hb concentration was also significantly higher in 21 of the 24 sectors in the control group compared with the glaucoma group ( P <0.05). The GDF had the largest areas under the receiver operating characteristic curve (0.93), with 79.3% sensitivity at a fixed specificity of 95%. CONCLUSION: Measurements of optic nerve Hb concentration using a colorimetry photographic device demonstrated good accuracy in discriminating healthy eyes from eyes with mild glaucoma. Further studies are need to understand vascular factors implicated in the development of glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Glaucoma de Ângulo Aberto/diagnóstico , Hemoglobinas , Humanos , Pressão Intraocular , Curva ROC , Tomografia de Coerência Óptica/métodos
2.
Rev. bras. oftalmol ; 79(1): 38-41, Jan.-Feb. 2020. tab, graf
Artigo em Português | LILACS | ID: biblio-1092654

RESUMO

Resumo Objetivo: Avaliar a efetividade e o perfil de segurança da ciclofotocoagulação transescleral padrão (CTCTE) e sua variação técnica denominada slow cooking (CTCTE SC) em pacientes com olho cego doloroso por glaucoma neovascular. Métodos: Pacientes foram submetidos a exame oftalmológico, graduando o nível da dor através de escala gráfica/numérica e divididos em dois grupos, um para tratamento com CTCTE e outro CTCTE SC. O acompanhamento foi realizado no primeiro, trigésimo e nonagésimo dias. Resultados: Dos 26 pacientes inclusos, 11 (42,3%) eram do sexo masculino. A idade média dos pacientes foi de 69 anos. Destes, 16 pacientes foram submetidos ao tratamento CTCTE e 10 pacientes a CTCTE SC. A pressão intraocular (PIO) teve média pré tratamento de 49 ± 23 mmHg no grupo CFCTE e medias no 1º, 30º e 90º dias pós-operatórios respectivamente: 32 ± 24 mmHg, 38 ± 18 mmHg, 43 ± 10 mmHg. No grupo submetido a técnica CFCTE SC a PIO prévia foi 54 ± 16 mmHg e médias no 1º, 30º e 90º dias pós-operatórios respectivamente: 38 ± 22 mmHg, 39 ± 10 mmHg , 44 ± 09 mmHg. A redução da dor foi efetiva em 88,4% pacientes. Durante o pós-operatório foi verificado hiperemia, quemose e hifema. Não foram observadas complicações graves. Conclusão: O tratamento do olho cego doloroso com ciclofotocoagulação transescleral com baixa carga foi um procedimento seguro e eficaz na resolução da dor, mas apresentou um baixo nível de redução da pressão intraocular em ambas técnicas usadas.


Abstract Objective: To evaluate the effectiveness and safety profile of standard transescleral cyclophotocoagulation (CTCTE) and its technical variation of slow cooking (CTCTE SC) in patients with neovascular glaucoma pain. Methods: Patients underwent ophthalmological examination, grading their pain level through a graphical / numerical scale and divided into two groups, one for treatment with CTCTE and another CTCTE SC. Follow-up was performed on the first, thirtieth and ninetieth days. Results: Of the 26 patients included, 11 (42.3%) were male. The average age of the patients was 69 years. Of these, 16 patients underwent CTCTE treatment and 10 patients underwent CTCTE SC. Intraocular pressure (IOP) had a mean pre-treatment of 49 ± 23 mmHg in the CFCTE group and medians at the 1st, 30th and 90th postoperative days respectively: 32 ± 24 mmHg, 38 ± 18 mmHg, 43 ± 10 mmHg. In the group submitted to the CFCTE SC technique, the previous IOP was 54 ± 16 mmHg and averages on the 1st, 30th and 90th postoperative days respectively: 38 ± 22 mmHg, 39 ± 10 mmHg, 44 ± 09 mmHg. Pain reduction was effective in 88.4% patients. During the postoperative period, hyperemia, chemosis and hyphema were observed. No serious complications were observed. Conclusion: Painful blind eye treatment with low load transscleral cyclophotocoagulation was a safe and effective procedure for pain resolution, but presented a low level of intraocular pressure reduction in both techniques used.


Assuntos
Humanos , Masculino , Feminino , Idoso , Glaucoma Neovascular/cirurgia , Glaucoma Neovascular/complicações , Cegueira/etiologia , Fotocoagulação a Laser/métodos , Dor Ocular/cirurgia , Esclera/cirurgia , Estudos Prospectivos , Lasers Semicondutores/uso terapêutico
3.
Rev. bras. oftalmol ; 76(6): 309-311, nov.-dez. 2017. graf
Artigo em Português | LILACS | ID: biblio-899097

RESUMO

Resumo Ruptura espontânea da cápsula anterior do cristalino, evoluindo com deslocamento anterior do núcleo é uma complicação rara da catarata hipermadura. Relatamos o caso de uma paciente do sexo feminino, 79 anos, que se apresentou com ruptura espontânea da cápsula anterior do cristalino com deslocamento anterior do núcleo em olho direito sem histórico de trauma ocular. O diagnóstico foi confirmado pela visualização das abas da cápsula anterior, principalmente quando o núcleo foi removido. Realizamos facoemulsificação do núcleo pelo risco de descompensar a córnea. É importante destacar a raridade do caso, sendo o primeiro relatado no Brasil.


Abstract Spontaneous rupture of the anterior lens capsule, evolving with anterior dislocation of the lens nucleus is a rare complication of hypermature cataract. We report a case of a female patient, 79 years old, who presented with spontaneous rupture of the anterior lens capsule with anterior dislocation of the nucleus in the right eye with no history of ocular trauma. The diagnosis was confirmed by the visualization of the tabs of the anterior capsule, especially when the nucleus was removed. We perform phacoemulsification of the nucleus by the risk of decompensating the cornea. It is important to highlight the rarity of the case, the first being reported in Brazil.


Assuntos
Humanos , Feminino , Idoso , Catarata/complicações , Subluxação do Cristalino/etiologia , Facoemulsificação/métodos , Núcleo do Cristalino/patologia , Câmara Anterior/patologia , Ruptura Espontânea , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Ultrassonografia , Microscopia com Lâmpada de Fenda , Pressão Intraocular , Câmara Anterior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA