Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Bioorg Med Chem Lett ; 84: 129193, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36822300

RESUMO

Inhibiting Arginase 1 (ARG1), a metalloenzyme that hydrolyzes l-arginine in the urea cycle, has been demonstrated as a promising therapeutic avenue in immuno-oncology through the restoration of suppressed immune response in several types of cancers. Most of the currently reported small molecule inhibitors are boronic acid based. Herein, we report the discovery of non-boronic acid ARG1 inhibitors through virtual screening. Biophysical and biochemical methods were used to experimentally profile the hits while X-ray crystallography confirmed a class of trisubstituted pyrrolidine derivatives as optimizable alternatives for the development of novel classes of immuno-oncology agents targeting this enzyme.


Assuntos
Arginase , Neoplasias , Humanos , Modelos Moleculares , Arginase/química , Inibidores Enzimáticos/farmacologia , Inibidores Enzimáticos/química , Ácidos Borônicos/farmacologia , Ácidos Borônicos/química , Arginina/química
2.
Anal Chem ; 93(15): 6071-6079, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33819010

RESUMO

The primary goal of high-throughput screening (HTS) is to rapidly survey a broad collection of compounds, numbering from tens of thousands to millions of members, and identify those that modulate the activity of a therapeutic target of interest. For nearly two decades, mass spectrometry has been used as a label-free, direct-detection method for HTS and is widely acknowledged as being less susceptible to interferences than traditional optical techniques. Despite these advantages, the throughput of conventional MS-based platforms like RapidFire or parallel LC-MS, which typically acquire data at speeds of 6-30 s/sample, can still be limiting for large HTS campaigns. To overcome this bottleneck, the field has recently turned to chromatography-free approaches including MALDI-TOF-MS and acoustic droplet ejection-MS, both of which are capable of throughputs of 1 sample/second or faster. In keeping with these advances, we report here on our own characterization of an acoustic droplet ejection, open port interface (ADE-OPI)-MS system as a platform for HTS using the membrane-associated, lipid metabolizing enzyme diacylglycerol acyltransferase 2 (DGAT2) as a model system. We demonstrate for the first time that the platform is capable of ejecting droplets from phase-separated samples, allowing direct coupling of liquid-liquid extraction with OPI-MS analysis. By applying the platform to screen a 6400-member library, we further demonstrate that the ADE-OPI-MS assay is suitable for HTS and also performs comparably to LC-MS, but with an efficiency gain of >20-fold.


Assuntos
Diacilglicerol O-Aciltransferase , Inibidores Enzimáticos/química , Ensaios de Triagem em Larga Escala , Acústica , Cromatografia Líquida , Diacilglicerol O-Aciltransferase/antagonistas & inibidores , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
3.
SLAS Technol ; 25(3): 276-285, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32003291

RESUMO

G-protein-coupled receptors (GPCRs) are modulated by many marketed drugs, and as such, they continue to be key targets for drug discovery and development. Many GPCR targets at Merck Research Laboratories (MRL) are profiled using homogenous time-resolved fluorescence (HTRF) inositol monophosphate (IP-1) cell-based functional assays using adherent cells in 384-well microplates. Due to discrepancies observed across several in vitro assays supporting lead optimization structure-activity relationship (SAR) efforts, different assay paradigms were evaluated for removing growth medium from the assay plates prior to compound addition and determination of IP-1 accumulation. Remarkably, employing the noncontact centrifugation BlueWasher method leads to left-shifted potencies across multiple structural classes and rescues "false negatives" relative to the traditional manual evacuation method. Further, assay performance is improved, with the minimum significant ratio of challenging chemotypes dropping from ~5-6 to <3. While the impact of BlueWasher on a broad range of our GPCR targets remains to be determined, for highly protein-bound small molecules, it provides a path toward improving assay reproducibility across scientists and sites as well as reducing replicates in SAR assay support.


Assuntos
Bioensaio/métodos , Células/metabolismo , Automação , Células HEK293 , Humanos , Reprodutibilidade dos Testes
4.
J Lab Autom ; 21(1): 57-63, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26460107

RESUMO

Quantitative reverse transcription PCR (qRT-PCR) is a valuable tool for characterizing the effects of inhibitors on viral replication. The amplification of target viral genes through the use of specifically designed fluorescent probes and primers provides a reliable method for quantifying RNA. Due to reagent costs, use of these assays for compound evaluation is limited. Until recently, the inability to accurately dispense low volumes of qRT-PCR assay reagents precluded the routine use of this PCR assay for compound evaluation in drug discovery. Acoustic dispensing has become an integral part of drug discovery during the past decade; however, acoustic transfer of microliter volumes of aqueous reagents was time consuming. The Labcyte Echo 525 liquid handler was designed to enable rapid aqueous transfers. We compared the accuracy and precision of a qPCR assay using the Labcyte Echo 525 to those of the BioMek FX, a traditional liquid handler, with the goal of reducing the volume and cost of the assay. The data show that the Echo 525 provides higher accuracy and precision compared to the current process using a traditional liquid handler. Comparable data for assay volumes from 500 nL to 12 µL allowed the miniaturization of the assay, resulting in significant cost savings of drug discovery and process streamlining.


Assuntos
Tecnologia Biomédica/métodos , Miniaturização/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Acústica , Avaliação Pré-Clínica de Medicamentos/métodos , Soluções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA