Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 23(1): 118, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-37046213

RESUMO

BACKGROUND: Atelectasis during general anesthesia is a risk for perioperative complications. EIT measurements were performed in mechanically ventilated healthy children during elective surgery to demonstrate the changes in ventilation distribution during general anesthesia. The ventilation distribution was quantified by calculating the Global Inhomogeneity index (GI). METHODS: EIT measurements were performed in 23 children (9 weeks-10 years) without lung disease to detect changes in regional ventilation during elective surgery. Three previously defined time points were marked during the measurement: after intubation and start of pressure-controlled ventilation (PCV), change to pressure support ventilation (PSV), and after extubation (spontaneous breathing-SB). Ventilation distribution based on regions of interest (ROI) and changes in end-expiratory volume (∆EELV) were collected at these time points and compared. The Global Inhomogeneity index was calculated at the beginning of pressure-controlled ventilation (PCV). RESULTS: With increasing spontaneous breathing, dorsal recruitment of atelectasis occurred. The dorsal ventilation fraction increased over the time of general anesthesia with increasing spontaneous breathing, whereas the ventral fraction decreased relatively (Difference ± 5.5 percentage points respectively; 95% CI; 3.5-7.4; p < 0.001). With the onset of spontaneous breathing, there was a significant reduction in end-expiratory volume (Difference: 105 ml; 95% CI, 75-135; p < 0.001). The GI of the lung-healthy ventilated children is 47% (SD ± 4%). CONCLUSION: Controlled ventilation of healthy children resulted in increased ventilation of the ventral and collapse of the dorsal lung areas. Restart of spontaneous breathing after cessation of surgery resulted in an increase in ventilation in the dorsal with decrease in the ventral lung areas. By calculating the GI, representing the ratio of more to less ventilated lung areas, revealed the presumed homogeneous distribution of ventilation. TRIAL REGISTRATION: ClinicalTrials.gov Registration ID: NCT04873999. First registration: 05/05/2021.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Criança , Humanos , Anestesia Geral/efeitos adversos , Impedância Elétrica , Pulmão , Respiração Artificial/métodos , Tomografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA