Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sci Transl Med ; 9(409)2017 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-28954927

RESUMO

The recent Zika virus (ZIKV) outbreak demonstrates that cost-effective clinical diagnostics are urgently needed to detect and distinguish viral infections to improve patient care. Unlike dengue virus (DENV), ZIKV infections during pregnancy correlate with severe birth defects, including microcephaly and neurological disorders. Because ZIKV and DENV are related flaviviruses, their homologous proteins and nucleic acids can cause cross-reactions and false-positive results in molecular, antigenic, and serologic diagnostics. We report the characterization of monoclonal antibody pairs that have been translated into rapid immunochromatography tests to specifically detect the viral nonstructural 1 (NS1) protein antigen and distinguish the four DENV serotypes (DENV1-4) and ZIKV without cross-reaction. To complement visual test analysis and remove user subjectivity in reading test results, we used image processing and data analysis for data capture and test result quantification. Using a 30-µl serum sample, the sensitivity and specificity values of the DENV1-4 tests and the pan-DENV test, which detects all four dengue serotypes, ranged from 0.76 to 1.00. Sensitivity/specificity for the ZIKV rapid test was 0.81/0.86, respectively, using a 150-µl serum input. Serum ZIKV NS1 protein concentrations were about 10-fold lower than corresponding DENV NS1 concentrations in infected patients; moreover, ZIKV NS1 protein was not detected in polymerase chain reaction-positive patient urine samples. Our rapid immunochromatography approach and reagents have immediate application in differential clinical diagnosis of acute ZIKV and DENV cases, and the platform can be applied toward developing rapid antigen diagnostics for emerging viruses.


Assuntos
Antígenos Virais/sangue , Vírus da Dengue/imunologia , Sorogrupo , Zika virus/imunologia , Sequência de Aminoácidos , Anticorpos Monoclonais/imunologia , Antígenos Virais/isolamento & purificação , Cromatografia de Afinidade , Mapeamento de Epitopos , Humanos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Alinhamento de Sequência
2.
J Immunoassay Immunochem ; 38(4): 355-377, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27982728

RESUMO

Point-of-care (POC) diagnostics such as lateral flow and dipstick immunoassays use gold nanoparticle (NP)-antibody conjugates for visual readout. We investigated the effects of NP conjugation, surface chemistries, and antibody immobilization methods on dipstick performance. We compared orientational, covalent conjugation, electrostatic adsorption, and a commercial conjugation kit for dipstick assays to detect dengue virus NS1 protein. Assay performance depended significantly on their conjugate properties. We also tested arrangements of multiple test lines within strips. Results show that orientational, covalent conjugation with PEG shield could improve NS1 detection. These approaches can be used to optimize immunochromatographic detection for a range of biomarkers.


Assuntos
Anticorpos/química , Anticorpos/imunologia , Imunoensaio/métodos , Nanopartículas Metálicas/química , Proteínas não Estruturais Virais/análise , Ouro/química , Humanos , Proteínas não Estruturais Virais/imunologia
4.
Eye Contact Lens ; 38(6): 379-84, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23085618

RESUMO

OBJECTIVE: To investigate the effects of eight different soft contact lenses on disinfection efficacy of a multipurpose solution (MPS) containing polyhexamethylene biguanide (PHMB) against Fusarium solani. METHODS: Six silicone hydrogel lenses (galyfilcon A, senofilcon A, comfilcon A, enfilcon A, balafilcon A, and lotrifilcon B) and two conventional hydrogel lenses (polymacon and etafilcon A) were placed in polypropylene lens cases filled with MPS containing 0.0001% PHMB and soaked for 6, 12, 24, 72, and 168 hours. After each interval, depleted MPS from lens cases were removed and assayed for activity against F. solani according to International Organization for Standardization (ISO) 14729 stand-alone procedure. A portion was aliquoted for chemical analysis. RESULTS: Soaking etafilcon A, balafilcon A, and polymacon lenses for 6 hours reduced the concentration of PHMB in MPS by more than half the stated labeled concentration, with concentrations below the limit of detection for etafilcon A-depleted and balafilcon A-depleted solutions after 12 and 72 hours of soaking, respectively. Except for comfilcon A-depleted solutions, all others failed to consistently obtain one log reduction of F. solani. The solutions soaked with etafilcon A, balafilcon A, and polymacon lenses for 24 hours or more lost all or almost all fungicidal activity against F. solani. CONCLUSIONS: Over time, the disinfectant uptake by some lenses can significantly reduce the PHMB concentration and the fungicidal activity of the MPS against F. solani. Current ISO methodology does not address the reduction in microbiocidal efficacy when lenses are soaked in MPS. The ISO committee should consider adding "soaking experiments" to quantify the effect that contact lens materials have on the performance of MPSs.


Assuntos
Soluções para Lentes de Contato/farmacologia , Lentes de Contato Hidrofílicas/microbiologia , Fusarium/efeitos dos fármacos , Biguanidas/análise , Contagem de Colônia Microbiana , Soluções para Lentes de Contato/análise , Desinfetantes/análise , Desinfetantes/farmacologia , Infecções Oculares Fúngicas/prevenção & controle , Fusariose/prevenção & controle , Fusarium/isolamento & purificação
5.
J Virol Methods ; 119(2): 121-8, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15158593

RESUMO

Monoclonal antibody H1206 anti-HSV-2 gG-2 bound to tosylactivated paramagnetic Dynabeads (Dynal) has been used to isolate HSV-2 type-specific gG-2 from solubilized HEp-2 HSV-2 infected cell extracts. The immunomagnetically captured type-specific glycoprotein reacted strongly with monoclonal antibody H1206 and demonstrated a single band with apparent molecular weight of 100000 (100 kDa) and a doublet band with an apparent molecular weight of 60000-64000 (60-64 kDa). We observed the same exact banding pattern when monoclonal H1206 was immunoblotted with Helix pomatia lectin purified HSV-2 gG-2. The immunomagnetically purified gG-2 was unreactive to monoclonal antibody H1379 anti-HSV-1 gG-1 and four human HSV antibody negative sera. In addition, 20 human HSV antibody positive sera obtained from the Centers for Disease Control (CDC), Atlanta, GA, were used for the evaluation of our methodology. Immunoblotting of the human HSV antibody positive samples were in agreement with the CDC HSV serological designation. Sera characterized by reactivity to the immunomagnetically purified gG-2 in conjunction with Western blot has the potential to be used as a confirmatory serological test or to determine the accuracy of clinical serological immunoassays used to determine HSV-2 seropositivity.


Assuntos
Anticorpos Monoclonais/imunologia , Separação Imunomagnética/métodos , Proteínas do Envelope Viral/imunologia , Proteínas do Envelope Viral/isolamento & purificação , Linhagem Celular , Humanos , Células Tumorais Cultivadas , Proteínas do Envelope Viral/análise , Proteínas do Envelope Viral/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA