RESUMO
The aim of the present study was to evaluate the safety and efficacy of radionuclide therapy with [177Lu]Lu-DOTA-TATE according to our single center experience at the University of Naples Federico II. For the present analysis, we considered 21 patients with progressive, advanced, well-differentiated G1 and G2 in patients with gastro-entero-pancreatic (GEP) neuroendocrine tumors (NETs) treated with [177Lu]Lu-DOTA-TATE according to the decisions of a multidisciplinary team. All patients underwent four cycles of 7-8 GBq of [177Lu]Lu-DOTA-TATE every 8 weeks. A whole-body scan (WBS) was performed 4, 48, and 168 h after each treatment. The dosimetry towards the organ at risk and target lesions was calculated. For each patient, renal and bone marrow parameters were evaluated before, during, and 3 months after the end of the treatment. Follow-up data were obtained and RECIST criteria were considered as the endpoint. Among 21 patients enrolled (mean age 65 ± 9 years); 17 (81%) were men and the small intestine was the most frequent location of disease (n = 12). A mild albeit significant variation (p < 0.05) in both platelets and white blood cell counts among all time points was observed, despite it disappearing 3 months after the end of the therapy. According to the RECIST criteria, 11 (55%) patients had a partial response to therapy and 8 (40%) had stable disease. Only one (5%) patient had disease progression 4 months after treatment. Our data confirm that [177Lu]Lu-DOTA is safe and effective in controlling the burden disease of G1/G2 GEP-NETs patients.
Assuntos
Neoplasias Intestinais , Tumores Neuroendócrinos , Octreotida , Neoplasias Pancreáticas , Neoplasias Gástricas , Humanos , Tumores Neuroendócrinos/radioterapia , Masculino , Feminino , Idoso , Neoplasias Pancreáticas/radioterapia , Pessoa de Meia-Idade , Octreotida/análogos & derivados , Octreotida/uso terapêutico , Neoplasias Intestinais/radioterapia , Neoplasias Gástricas/radioterapia , Compostos Organometálicos/uso terapêutico , Receptores de Peptídeos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Resultado do TratamentoRESUMO
Two-dimensional transition metal dichalcogenides, particularly MoS2, are interesting materials for many applications in aerospace research, radiation therapy and bioscience more in general. Since in many of these applications MoS2-based nanomaterials can be placed in an aqueous environment while exposed to ionizing radiation, both experimental and theoretical studies of their behaviour under these conditions is particularly interesting. Here, we study the effects of tiny imparted doses of 511 keV photons to MoS2 nanoflakes in water solution. To the best of our knowledge, this is the first study in which ionizing radiation on 2D-MoS2 occurs in water. Interestingly, we find that, in addition to the direct interaction between high-energy photons and nanoflakes, reactive chemical species, generated by γ-photons induced radiolysis of water, come into play a relevant role. A radiation transport Monte Carlo simulation allowed determining the elements driving the morphological and spectroscopical changes of 2D-MoS2, experimentally monitored by SEM microscopy, DLS, Raman and UV-vis spectroscopy, AFM, and X-ray photoelectron techniques. Our study demonstrates that radiolysis products affect the Molybdenum oxidation state, which is massively changed from the stable + 4 and + 6 states into the rarer and more unstable + 5. These findings will be relevant for radiation-based therapies and diagnostics in patients that are assuming drugs or contrast agents containing 2D-MoS2 and for aerospace biomedical applications of 2DMs investigating their actions into living organisms on space station or satellites.
RESUMO
BACKGROUND/AIM: Neoadjuvant systemic therapy (NAT) in breast cancer can make tumors resectable or reduce the extent of surgery needed for locally advanced cancers. It can also better prevent distant relapse and possibly modulate drug therapy by adjusting adjuvant therapy (AD) based on the response to NAT, either by escalating or de-escalating the treatment. However, clear evidence of improved outcomes is currently missing. Here, we report on breast cancer patients treated with NAT at our institution. PATIENTS AND METHODS: One hundred twenty-seven patients treated at our Radiation Oncology department between 2004 and 2021 were retrospectively analyzed. All patients had localized or locally advanced breast cancer, were treated with NAT, and received postoperative radiotherapy. The outcomes considered were overall survival (OS), loco-regional recurrence-free survival (LRRFS), and distant metastases-free survival (DMFS). A matched patient population treated with AD during the same period and at the same center was used for comparison. RESULTS: The 5-year predicted OS was 87% in the NAT group and 81.5% in the AD group (p-value=0.179), while LRRFS was 93.2% in the NAT group and 100% in the AD group (p=0.005). The 5-year predicted DMFS was 84.6% in the NAT group and 82.1% in AD patients (p=0.367). In the NAT group, the only prognostic factor significantly related to improved outcomes was the pathological node response, with an OS of 95.6% in patients without residual node disease compared to 75.1% in patients with evidence of residual node disease. CONCLUSION: Our study, despite the limitations of a small number of patients and its retrospective nature, confirms the data of previous larger studies. In terms of DMFS and OS, NAT is at least as effective as AD. NAT represents a great opportunity for personalized modulation of treatment in node-positive breast cancer patients.
Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/mortalidade , Neoplasias da Mama/terapia , Feminino , Pessoa de Meia-Idade , Quimioterapia Adjuvante , Idoso , Estudos de Casos e Controles , Adulto , Estudos Retrospectivos , Intervalo Livre de Doença , Recidiva Local de Neoplasia/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêuticoRESUMO
Presented here is a case report of a 77-year-old woman affected by rheumatoid arthritis who underwent breast-conserving surgery followed by radiation therapy (RT) for left-breast cancer and developed bronchiolitis obliterans organizing pneumonia (BOOP) after RT and during a COVID-19 vaccination campaign. BOOP incidence is an uncommon morbidity after breast RT (1.2%-2.9%); however, specific predisposing factors can play a role. In this patient, both rheumatoid arthritis and the vaccine may have predisposed her to an increased risk of organizing pneumonia, probably by triggering a proinflammatory cascade. Our report highlights the importance of factors that influence the occurrence of uncommon radiation-induced morbidities, such as BOOP, in specific subsets of patients. Further studies are necessary to evaluate factors increasing radiation sensitivity.
Assuntos
Neoplasias da Mama , Pneumonia em Organização Criptogênica , Humanos , Feminino , Pneumonia em Organização Criptogênica/etiologia , Idoso , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , COVID-19/complicações , Artrite Reumatoide/radioterapia , Artrite Reumatoide/complicações , SARS-CoV-2 , Vacinas contra COVID-19/efeitos adversosRESUMO
Stereotactic radiation therapy (SRT) is a proven effective treatment for brain metastases (BM); however, symptomatic radiation necrosis (RN) is a late effect that may impact on patient's quality of life. The aim of our study was to retrospectively evaluate survival outcomes and characterize the occurrence of RN in a cohort of BM patients treated with ablative SRT at Federico II University Hospital. Clinical and dosimetric factors of 87 patients bearing a total of 220 BMs treated with SRT from 2016 to 2022 were analyzed. Among them, 46 patients with 127 BMs having clinical and MRI follow-up (FUP) ≥ 6 months were selected for RN evaluation. Dosimetric parameters of the uninvolved brain (brain without GTV) were extracted. The crude local control was 91% with neither clinical factors nor prescription dose correlating with local failure (LF). At a median FUP of 9 (1-68) months, the estimated median overall survival (OS), progression-free survival (PFS), and brain progression-free survival (bPFS) were 16, 6, and 9 months, respectively. The estimated OS rates at 1 and 3 years were 59.8% and 18.3%, respectively; bPFS at 1 and 3 years was 29.9% and 13.5%, respectively; PFS at 1 and 3 years was 15.7% and 0%, respectively; and local failure-free survival (LFFS) at 1 and 3 years was 87.2% and 83.8%, respectively. Extracranial disease status was an independent factor related to OS. Fourteen (30%) patients manifested RN. At multivariate analysis, adenocarcinoma histology, left location, and absence of chemotherapy were confirmed as independent risk factors for any-grade RN. Nine (20%) patients developed symptomatic (G2) RN, which improved or stabilized after 1-16 months of steroid therapy. With prompt recognition and, when necessary, medical therapy, RN radiological and clinical amelioration can be obtained.
RESUMO
Objective. We present a method for personalized organ dose estimates obtained before the computed tomography (CT) exam, via 3D optical body scanning and Monte Carlo (MC) simulations.Approach. A voxelized phantom is derived by adapting a reference phantom to the body size and shape measured with a portable 3D optical scanner, which returns the 3D silhouette of the patient. This was used as an external rigid envelope for incorporating a tailored version of the internal body anatomy derived from a phantom dataset (National Cancer Institute, NIH, USA) matched for gender, age, weight, and height. The proof-of-principle was conducted on adult head phantoms. The Geant4 MC code provided estimates of the organ doses from 3D absorbed dose maps in the voxelized body phantom.Main results. We applied this approach for head CT scanning using an anthropomorphic voxelized head phantom derived from 3D optical scans of manikins. We compared the estimates of head organ doses with those provided by the NCICT 3.0 software (NCI, NIH, USA). Head organ doses differed up to 38% using the proposed personalized estimate and MC code, with respect to corresponding estimates calculated for the standard (non-personalized) reference head phantom. Preliminary application of the MC code to chest CT scans is shown. Real-time pre-exam personalized CT dosimetry is envisaged with adoption of a Graphics Processing Unit-based fast MC code.Significance. The developed procedure for personalized organ dose estimates before the CT exam, introduces a new approach for realistic description of size and shape of patients via voxelized phantoms specific for each patient.
Assuntos
Radiometria , Tomografia Computadorizada Espiral , Adulto , Humanos , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Software , Imagens de Fantasmas , Método de Monte CarloRESUMO
Uveal melanoma (UM) represents the most common primary intraocular tumor, and nowadays eye plaque brachytherapy (EPB) is the most frequently used visual acuity preservation treatment option for small to medium sized UMs. The excellent local tumor control (LTC) rate achieved by EPB may be associated with severe complications and adverse events. Several dosimetric and clinical risk factors for the development of EPB-related ocular morbidity can be identified. However, morbidity predictive models specifically developed for EPB are still scarce. PRISMA methodology was used for the present systematic review of articles indexed in PubMed in the last sixteen years on EPB treatment of UM which aims at determining the major factors affecting local tumor control and ocular morbidities. To our knowledge, for the first time in EPB field, local tumor control probability (TCP) and normal tissue complication probability (NTCP) modelling on pooled clinical outcomes were performed. The analyzed literature (103 studies including 21,263 UM patients) pointed out that Ru-106 EPB provided high local control outcomes while minimizing radiation induced complications. The use of treatment planning systems (TPS) was the most influencing factor for EPB outcomes such as metastasis occurrence, enucleation, and disease specific survival, irrespective of radioactive implant type. TCP and NTCP parameters were successfully extracted for 5-year LTC, cataract and optic neuropathy. In future studies, more consistent recordings of ocular morbidities along with accurate estimation of doses through routine use of TPS are needed to expand and improve the robustness of toxicity risk prediction in EPB.
Assuntos
Braquiterapia , Melanoma , Lesões por Radiação , Neoplasias Uveais , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Humanos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Estudos Retrospectivos , Neoplasias Uveais/radioterapiaRESUMO
PURPOSE: The influence of basic plan parameters such as slice thickness, grid resolution, algorithm type and field size on calculated small field output factors (OFs) was evaluated in a multicentric study. METHODS AND MATERIALS: Three computational homogeneous water phantoms with slice thicknesses (ST) 1, 2 and 3 mm were shared among twenty-one centers to calculate OFs for 1x1, 2x2 and 3x3 cm2 field sizes (FSs) (normalized to 10x10 cm2 FS), with their own treatment planning system (TPS) and the energy clinically used for stereotactic body radiation therapy delivery. OFs were calculated for each combination of grid resolution (GR) (1, 2 and 3 mm) and ST and finally compared with the OFs measured for the TPS commissioning. A multivariate analysis was performed to test the effect of basic plan parameters on calculated OFs. RESULTS: A total of 509 data points were collected. Calculated OFs are slightly higher than measured ones. The multivariate analysis showed that Center, GR, algorithm type, and FS are predictive variables of the difference between calculated and measured OFs (p < 0.001). As FS decreases, the spread in the difference between calculated and measured OFs became larger when increasing the GR. Monte Carlo and Analytical Anisotropic Algorithms, presented a dependence on GR (p < 0.01), while Collapsed Cone Convolution and Acuros did not. The effect of the ST was found to be negligible. CONCLUSIONS: Modern TPSs slightly overestimate the calculated small field OFs compared with measured ones. Grid resolution, algorithm, center number and field size influence the calculation of small field OFs.
Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem RadioterapêuticaRESUMO
OBJECTIVES: This multicentric study was carried out to investigate the impact of small field output factors (OFs) inaccuracies on the calculated dose in volumetric arctherapy (VMAT) radiosurgery brain plans. METHODS: Nine centres, realised the same five VMAT plans with common planning rules and their specific clinical equipment Linac/treatment planning system commissioned with their OFs measured values (OFbaseline). In order to simulate OFs errors, two new OFs sets were generated for each centre by changing only the OFs values of the smallest field sizes (from 3.2 × 3.2 cm2 to 1 × 1 cm2) with well-defined amounts (positive and negative). Consequently, two virtual machines for each centre were recommissioned using the new OFs and the percentage dose differences ΔD (%) between the baseline plans and the same plans recalculated using the incremented (OFup) and decremented (OFdown) values were evaluated. The ΔD (%) were analysed in terms of planning target volume (PTV) coverage and organs at risk (OARs) sparing at selected dose/volume points. RESULTS: The plans recalculated with OFdown sets resulted in higher variation of doses than baseline within 1.6 and 3.4% to PTVs and OARs respectively; while the plans with OFup sets resulted in lower variation within 1.3% to both PTVs and OARs. Our analysis highlights that OFs variations affect calculated dose depending on the algorithm and on the delivery mode (field jaw/MLC-defined). The Monte Carlo (MC) algorithm resulted significantly more sensitive to OFs variations than all of the other algorithms. CONCLUSION: The aim of our study was to evaluate how small fields OFs inaccuracies can affect the dose calculation in VMAT brain radiosurgery treatments plans. It was observed that simulated OFs errors, return dosimetric calculation accuracies within the 3% between concurrent plans analysed in terms of percentage dose differences at selected dose/volume points of the PTV coverage and OARs sparing. ADVANCES IN KNOWLEDGE: First multicentre study involving different Planning/Linacs about undetectable errors in commissioning output factor for small fields.
Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , IncertezaRESUMO
PURPOSE: The aim of the study was to exploit the feasibility of thermoluminescent dosimeters (TLDs) in radiation therapy techniques in which high dose per fraction is involved. METHODS: Dose-response of TLD-100 (LiF: Mg, Ti) was investigated in both 6-MV photon and 6-MeV electron beams. The element correction factor (ECF) generation method was applied to check the variability of the TLDs response. Two batches of 50 TLDs were divided into groups and exposed in the dose range 0 to 30 Gy. Regression analysis was performed with both linear and quadratic models. For each irradiation beam, the calibration curves were obtained in 3 dose range 0 to 8 Gy, 0 to 10 Gy, and 0 to 30 Gy. The best-fitting model was assessed by the Akaike Information Criterion test. RESULTS: The ECF process resulted a useful tool to reduce the coefficients of variation from original values higher than 5% to about 3.5%, for all the batches exposed. The results confirm the linearity of dose-response curve below the dose level of 10 Gy for photon and electron beam and the supralinear trend above. CONCLUSION: The TLDs are suitable dosimeters for dose monitoring and verification in radiation treatment involving dose up to 30 Gy in a single fraction.
RESUMO
The contemporary approach to the management of a cancer patient requires an "ab initio" involvement of different medical domains in order to correctly design an individual patient's pathway toward cure. With new therapeutic tools in every medical field developing faster than ever before the patient care outcomes can be achieved if all surgical, drug, and radiation options are considered in the design of the appropriate therapeutic strategy for a given patient. Radiation therapy (RT) is a clinical discipline in which experts from different fields continuously interact in order to manage the multistep process of the radiation treatment. RT is found to be an appropriate intervention for diverse indications in about 50% of cancer patients during the course of their disease. Technologies are essential in dealing with the complexity of RT treatments and for driving the increasingly sophisticated RT approaches becoming available for the treatment of Cancer. High conformal techniques, namely intensity modulated or volumetric modulated arc techniques, ablative techniques (Stereotactic Radiotherapy and Stereotactic Radiosurgery), particle therapy (proton or carbon ion therapy) allow for success in treating irregularly shaped or critically located targets and for the sharpness of the dose fall-off outside the target. The advanced on-board imaging, including real-time position management systems, makes possible image-guided radiation treatment that results in substantial margin reduction and, in select cases, implementation of an adaptive approach. The therapeutic gains of modern RT are also due in part to the enhanced anticancer activity obtained by coadministering RT with chemotherapy, targeted molecules, and currently immune checkpoints inhibitors. These main clinically relevant steps forward in Radiation Oncology represent a change of gear in the field that may have a profound impact on the management of cancer patients.
Assuntos
Neoplasias/radioterapia , Radioterapia (Especialidade)/tendências , Radioterapia Guiada por Imagem/tendências , Radioterapia de Intensidade Modulada/tendências , Radioterapia com Íons Pesados , Humanos , RadiocirurgiaRESUMO
BACKGROUND: The dosimetric variability in spine stereotactic body radiation therapy (SBRT) planning was investigated in a large number of centres to identify crowd knowledge-based solutions. METHODS: Two spinal cases were planned by 48 planners (38 centres). The required prescription dose (PD) was 3â¯× 10â¯Gy and the planning target volume (PTV) coverage request was: VPDâ¯> 90% (minimum request: VPDâ¯> 80%). The dose constraints were: planning risk volume (PRV) spinal cord: V18Gyâ¯< 0.35â¯cm3, V21.9 Gyâ¯< 0.03â¯cm3; oesophagus: V17.7 Gyâ¯< 5â¯cm3, V25.2 Gyâ¯< 0.03â¯cm3. Planners who did not fulfil the protocol requirements were asked to re-optimize the plans, using the results of planners with the same technology. Statistical analysis was performed to assess correlations between dosimetric results and planning parameters. A quality index (QI) was defined for scoring plans. RESULTS: In all, 12.5% of plans did not meet the protocol requirements. After re-optimization, 98% of plans fulfilled the constraints, showing the positive impact of knowledge sharing. Statistical analysis showed a significant correlation (pâ¯< 0.05) between the homogeneity index (HI) and PTV coverage for both cases, while the correlation between HI and spinal cord sparing was significant only for the single dorsal PTV case. Moreover, the multileaf collimator leaf thickness correlated with the spinal cord sparing. Planners using comparable delivery/planning system techniques produced different QI, highlighting the impact of the planner's skills in the optimization process. CONCLUSION: Both the technology and the planner's skills are fundamentally important in spine SBRT planning optimization. Knowledge sharing helped to follow the plan objectives.
Assuntos
Radiometria , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Competência Clínica , Correlação de Dados , Humanos , Órgãos em Risco/efeitos da radiação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Lesões por Radiação/prevenção & controle , Medula Espinal/efeitos da radiaçãoRESUMO
BACKGROUND: Technological advances in Hodgkin lymphoma (HL) radiation therapy (RT) by high conformal treatments potentially increase control over organs-at-risk (OARs) dose distribution. However, plan optimization remains a time-consuming task with great operator dependent variability. Purpose of the present study was to devise a fully automated pipeline based on the Pinnacle3 Auto-Planning (AP) algorithm for treating female supradiaphragmatic HL (SHL) patients. METHODS: CT-scans of 10 female patients with SHL were considered. A "butterfly" (BF) volumetric modulated arc therapy was optimized using SmartArc module integrated in Pinnacle3 v. 9.10 using Collapsed Cone Convolution Superposition algorithm (30 Gy in 20 fractions). Human-driven (Manual-BF) and AP-BF optimization plans were generated. For AP, an optimization objective list of Planning Target Volume (PTV)/OAR clinical goals was first implemented, starting from a subset of 5 patients used for algorithm training. This list was then tested on the remaining 5 patients (validation set). In addition to the BF technique, the AP engine was applied to a 2 coplanar disjointed arc (AP-ARC) technique using the same objective list. For plan evaluation, dose-volume-histograms of PTVs and OARs were extracted; homogeneity and conformity indices (HI and CI), OARs dose-volume metrics and odds for different toxicity endpoints were computed. Non-parametric Friedman and Dunn tests were used to identify significant differences between groups. RESULTS: A single AP objective list for SHL was obtained. Compared to the manual plan, both AP-plans offer comparable CIs while AP-ARC also achieved comparable HIs. All plans fulfilled the clinical dose criteria set for OARs: both AP solutions performed at least as good as Manual-BF plan. In particular, AP-ARC outperformed AP-BF in terms of heart sparing involving a lower risk of coronary events and radiation-induced lung fibrosis. Hands-on planning time decreased by a factor of 10 using AP on average. CONCLUSIONS: Despite the high interpatient PTV (size and position) variability, it was possible to set a standard SHL AP optimization list with a high level of generalizability. Using the implemented list, the AP module was able to limit OAR doses, producing clinically acceptable plans with stable quality without additional user input. Overall, the AP engine associated to the arc technique represents the best option for SHL.
Assuntos
Doença de Hodgkin/radioterapia , Neoplasias do Mediastino/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Automação , Feminino , Humanos , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodosRESUMO
Large uncertainties in output factor (OF) small fields dosimetry motivated multicentric studies. The focus of the study was the determination of the OFs, for different linacs and radiosurgery units, using new-generation detectors. Intercomparison studies between radiotherapy centers improved quality dosimetry practices. Results confirmed the effectiveness of the studies to uncover large systematic inaccuracies in small field dosimetry.
RESUMO
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation therapy (SBRT) in lung cancer management. In this context, the very high doses delivered to the Planning Target Volume, make the planning phase essential for achieving high dose levels conformed to the shape of the target in order to have a good prognosis for tumor control and to avoid an overdose in relevant healthy adjacent tissue. In this non-systematic review we analyzed the technological and the physics aspects of SBRT planning for lung cancer. In particular, the aims of the study were: (i) to evaluate prescription strategies (homogeneous or inhomogeneous), (ii) to outline possible geometrical solutions by comparing the dosimetric results (iii) to describe the technological possibilities for a safe and effective treatment, (iv) to present the issues concerning radiobiological planning and the automation of the planning process.
Assuntos
Neoplasias Pulmonares/radioterapia , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/normasRESUMO
PURPOSE: The aim of the study was a multicenter evaluation of MLC&jaws-defined small field output factors (OF) for different linear accelerator manufacturers and for different beam energies using the latest synthetic single crystal diamond detector commercially available. The feasibility of providing an experimental OF data set, useful for on-site measurements validation, was also evaluated. METHODS: This work was performed in the framework of the Italian Association of Medical Physics (AIFM) SBRT working group. The project was subdivided in two phases: in the first phase each center measured OFs using their own routine detector for nominal field sizes ranging from 10×10cm2 to 0.6×0.6cm2. In the second phase, the measurements were repeated in all centers using the PTW 60019 microDiamond detector. RESULTS: The project enrolled 30 Italian centers. Micro-ion chambers and silicon diodes were used for OF measurements in 24 and 6 centers respectively. Gafchromic films and TLDs were used for very small field OFs in 3 and 1 centers. Regarding the measurements performed with the user's detectors, OF standard deviations (SD) for field sizes down to 2×2cm2 were in all cases <2.7%. In the second phase, a reduction of around 50% of the SD was obtained using the microDiamond detector. CONCLUSIONS: The measured values presented in this multicenter study provide a consistent dataset for OFs that could be a useful tool for improving dosimetric procedures in centers. The microDiamond data present a small variation among the centers confirming that this detector can contribute to improve overall accuracy in radiotherapy.
Assuntos
Diamante , Aceleradores de Partículas , Radiometria/instrumentação , Estudos de Viabilidade , Método de Monte Carlo , SilícioRESUMO
OBJECTIVE: Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. METHODS: Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 ((125)I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. (125)I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan-Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. RESULTS: Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p < 0.0001) and V100 (p = 0.09) were correlated with BFFS, with V100 effect significantly different between patients at low risk and those at intermediate/high risk (p = 0.04). Short follow-up and lack of toxicity data represent the main limitations for a global evaluation of LDR-BT. CONCLUSION: This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. ADVANCES IN KNOWLEDGE: Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome.
Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/mortalidade , Relação Dose-Resposta à Radiação , Humanos , Itália/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Padrões de Prática Médica , Antígeno Prostático Específico , Neoplasias da Próstata/mortalidade , Dosagem Radioterapêutica , Resultado do Tratamento , Ultrassonografia de Intervenção/métodosRESUMO
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation Therapy (SBRT) in prostate cancer management. In this context, the medical physicists are regularly involved to review the appropriateness of the adopted technology and to proactively study new solutions. From the physics point of view there are two major challenges in prostate SBRT: (1) mitigation of geometrical uncertainty and (2) generation of highly conformal dose distributions that maximally spare the OARs. Geometrical uncertainties have to be limited as much as possible in order to avoid the use of large PTV margins. Furthermore, advanced planning and delivery techniques are needed to generate maximally conformal dose distributions. In this non-systematic review the technology and the physics aspects of SBRT for prostate cancer were analyzed. In details, the aims were: (i) to describe the rationale of reducing the number of fractions (i.e. increasing the dose per fraction), (ii) to analyze the features to be accounted for performing an extreme hypo-fractionation scheme (>6-7Gy), and (iii) to describe technological solutions for treating in a safe way. The analysis of outcomes, toxicities, and other clinical aspects are not object of the present evaluation.
Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Fracionamento da Dose de Radiação , Física Médica , Humanos , MasculinoRESUMO
PURPOSE: A large-scale multi-institutional planning comparison on lung cancer SABR is presented with the aim of investigating possible criticism in carrying out retrospective multicentre data analysis from a dosimetric perspective. METHODS: Five CT series were sent to the participants. The dose prescription to PTV was 54Gy in 3 fractions of 18Gy. The plans were compared in terms of PTV-gEUD2 (generalized Equivalent Uniform Dose equivalent to 2Gy), mean dose to PTV, Homogeneity Index (PTV-HI), Conformity Index (PTV-CI) and Gradient Index (PTV-GI). We calculated the maximum dose for each OAR (organ at risk) considered as well as the MLD2 (mean lung dose equivalent to 2Gy). The data were stratified according to expertise and technology. RESULTS: Twenty-six centers equipped with Linacs, 3DCRT (4% - 1 center), static IMRT (8% - 2 centers), VMAT (76% - 20 centers), CyberKnife (4% - 1 center), and Tomotherapy (8% - 2 centers) collaborated. Significant PTV-gEUD2 differences were observed (range: 105-161Gy); mean-PTV dose, PTV-HI, PTV-CI, and PTV-GI were, respectively, 56.8±3.4Gy, 14.2±10.1%, 0.70±0.15, and 4.9±1.9. Significant correlations for PTV-gEUD2 versus PTV-HI, and MLD2 versus PTV-GI, were observed. CONCLUSIONS: The differences in terms of PTV-gEUD2 may suggest the inclusion of PTV-gEUD2 calculation for retrospective data inter-comparison.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Radiocirurgia/instrumentação , Tomografia Computadorizada por Raios X/métodosRESUMO
PURPOSE: To compare five liver metastasis stereotactic ablative radiotherapy (SABR) plans optimised in fourteen centres with 3D-Conformal-RT, IMRT, VMAT, CyberKnife and Tomotherapy and identify possible dosimetric differences. METHODS: Dose prescription was 75 Gy in 3 fractions, normalised at 67%-95% isodose. RESULTS: Excluding few cases, all institutions achieved the planning objectives. Differences up to 40% and 25% in mean dose to liver and PTV were found. No significant correlations between technological factors and DVH for target and OARs were observed; the optimisation strategies selected by the planners played a key role in the planning procedure. CONCLUSIONS: The human factor and the constraints imposed to the target volume have a greater dosimetric impact than treatment planning and radiation delivery technology in stereotactic treatment of liver metastases. Significant differences found both in terms of dosimetric target coverage and OAR sparing should be taken into consideration before starting a multi-institutional SARB clinical trial.