Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
J Am Coll Surg ; 238(4): 551-558, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38230854

RESUMO

BACKGROUND: Vertical sleeve gastrectomy is the most performed bariatric operation in the US; however, a significant number of patients suffer from persistent or new-onset reflux. No consensus for objective preoperative evaluation in these patients exists. We compared capsule-based pH testing vs GERD symptom scoring to determine extent of preoperative GERD to aid in procedure selection for bariatric surgery. STUDY DESIGN: An IRB-approved retrospective review of consecutive patients at a single institution was performed from April 2021 to December 2022. During initial consultation for bariatric surgery, a validated GERD symptom subjective survey was administered. All patients demonstrating interest in sleeve gastrectomy or had a history of reflux underwent upper endoscopy with capsule-based pH testing. RESULTS: Sixty-two patients underwent preoperative endoscopy with capsule-based pH testing and completed GERD symptom assessment survey(s). Median BMI was 43.4 kg/m 2 and 66.1% of patients were not taking a proton-pump inhibitor before performance of pH testing. There was negligible linear association between the objective DeMeester score obtained by capsule-based pH probe and GERD symptom survey scores. Median GERD symptom survey scores did not differ between patients with and without a diagnosis of GERD based on pH testing (all p values >0.11). CONCLUSIONS: An objective method for identifying severe GERD in the preoperative assessment may aid in the decision tree for procedure selection and informed consent process. Patients with significant preoperative GERD may be at higher risk for future GERD-related sleeve complications. Capsule-based pH testing may prove to be superior to subjective symptom scoring systems in this patient population.


Assuntos
Cirurgia Bariátrica , Refluxo Gastroesofágico , Laparoscopia , Obesidade Mórbida , Humanos , Refluxo Gastroesofágico/cirurgia , Cirurgia Bariátrica/métodos , Cuidados Pré-Operatórios/métodos , Endoscopia/efeitos adversos , Concentração de Íons de Hidrogênio , Estudos Retrospectivos , Obesidade Mórbida/diagnóstico , Obesidade Mórbida/cirurgia , Obesidade Mórbida/complicações , Gastrectomia/métodos , Laparoscopia/efeitos adversos
2.
J Neurosurg ; : 1-10, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37948684

RESUMO

OBJECTIVE: The literature on non-small cell lung cancer (NSCLC) brain metastases (BMs) managed using stereotactic radiosurgery (SRS) relies mainly on single-institution studies or randomized controlled trials (RCTs). There is a literature gap on clinical and radiological outcomes of SRS for NSCLC metastases in real-world practice. The objective of this study was to benchmark mortality and progression outcomes in patients undergoing SRS for NSCLC BMs and identify risk factors for these outcomes using a national quality registry. METHODS: The SRS Registry of the NeuroPoint Alliance was used for this study. This registry included patients from 16 enrolling sites who underwent SRS from 2017 to 2022. Data are prospectively collected without a prespecified research purpose. The main outcomes of this analysis were overall survival (OS), out-of-field recurrence, local progression, and intracranial progression. All time-to-event investigations included Kaplan-Meier analyses and multivariable Cox regressions. RESULTS: Two hundred sixty-four patients were identified, with a mean age of 66.7 years and a female proportion of 48.5%. Most patients (84.5%) had a Karnofsky Performance Status (KPS) score of 80-100, and the mean baseline EQ-5D score was 0.539 quality-adjusted life years. A single lesion was present in 53.4% of the patients, and 29.1% of patients had 3 or more lesions. The median OS was 28.1 months, and independent predictors of mortality included no control of primary tumor (hazard ratio [HR] 2.1), KPS of 80 (HR 2.4) or lower (HR 2.4), coronary artery disease (HR 2.8), and 5 or more lesions present at the time of SRS treatment (HR 2.3). The median out-of-field progression-free survival (PFS) was 24.8 months, and the median local PFS was unreached. Intralesional hemorrhage was an independent risk factor of local progression, with an HR of 6.0. The median intracranial PFS was 14.0 months and was predicted by the number of lesions at the time of SRS (3-4 lesions, HR 2.2; 5-14 lesions, HR 2.5). CONCLUSIONS: In this real-world prospective study, the authors used a national quality registry and found favorable OS in patients with NSCLC BMs undergoing SRS compared with results from previously published RCTs. The intracranial PFS was mainly driven by the emergence of new lesions rather than local progression. A greater number of lesions at baseline was associated with out-of-field progression, while intralesional hemorrhage at baseline was associated with local progression.

3.
Am J Surg ; 226(6): 896-900, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37633763

RESUMO

INTRODUCTION: Nearly 20% of ventral hernia repair (VHR) patients require a subsequent abdominal operation (SAO), and mesh position may impact the complexity and outcome of the SAO. METHODS: Retrospective review of VHR with mesh from 2006 to 2020 from an internal database and the ACHQC. Primary outcomes measured incidence, complexity, and complications of SAO relative to mesh position. RESULTS: SAO was required in 433 of 2539 (17.1%) patients, totaling 671 operations; 197/893 (22.1%) with intraperitoneal mesh (IPM) and 236/1646 (14.3%) with extraperitoneal mesh (EPM; p â€‹< â€‹0.001). SAO was directly related to VHR in 180 (232 total SAOs) and unrelated in 253 (439 total SAOs). There were no significant differences in complications after SAO between IPM and EPM, nor any difference in adhesion complexity. CONCLUSION: Incidence of SAO is higher with IPM, but surgical outcomes are similar. Due to the risk of secondary mesh infection with IPM, significantly more of these were removed at the time of SAO.


Assuntos
Hérnia Ventral , Telas Cirúrgicas , Humanos , Hérnia Ventral/cirurgia , Herniorrafia , Aderências Teciduais/cirurgia , Incidência , Estudos Retrospectivos , Recidiva , Resultado do Tratamento
4.
J Neuropathol Exp Neurol ; 82(10): 845-852, 2023 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-37550258

RESUMO

Homozygous deletion of CDKN2A/B is currently considered a molecular signature for grade 4 in IDH-mutant astrocytomas, irrespective of tumor histomorphology. The 2021 WHO Classification of CNS Tumors does not currently include grading recommendations for histologically lower-grade (grade 2-3) IDH-mutant astrocytoma with CDKN2A mutation or other CDKN2A alterations, and little is currently known about the prognostic implications of these alternative CDKN2A inactivating mechanisms. To address this, we evaluated a cohort of institutional and publicly available IDH-mutant astrocytomas, 15 with pathogenic mutations in CDKN2A, 47 with homozygous CDKN2A deletion, and 401 with retained/wildtype CDKN2A. The IDH-mutant astrocytomas with mutant and deleted CDKN2A had significantly higher overall copy number variation compared to those with retained/wildtype CDKN2A, consistent with more aggressive behavior. Astrocytoma patients with CDKN2A mutation had significantly worse progression-free (p = 0.0025) and overall survival (p < 0.0001) compared to grade-matched patients with wildtype CDKN2A, but statistically equivalent progression-free survival and overall survival outcomes to patients with CDKN2A deletion. No significant survival difference was identified between CDKN2A mutant cases with or without loss of the second allele. These findings suggest that CDKN2A mutation has a detrimental effect on survival in otherwise lower-grade IDH-mutant astrocytomas, similar to homozygous CDKN2A deletion, and should be considered for future grading schemes.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Humanos , Prognóstico , Neoplasias Encefálicas/patologia , Homozigoto , Variações do Número de Cópias de DNA , Deleção de Sequência , Isocitrato Desidrogenase/genética , Astrocitoma/patologia , Mutação/genética , Inibidor p16 de Quinase Dependente de Ciclina/genética
5.
Am J Surg ; 226(6): 858-863, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37481407

RESUMO

BACKGROUND: Alternatives to opioid analgesia are needed to reduce the risk of abuse, misuse, and diversion. Musculoskeletal pain is a significant contributor to postoperative pain after ventral hernia repair (VHR). We report the impact of methocarbamol on opioid prescribing after VHR. METHODS: Review of all robotic and open VHR, Jan 2020-July 2022. Data was collected in the Abdominal Core Health Quality Collaborative (ACHQC) with additional chart review to assess for opioid refills. A 2:1 propensity score match was performed comparing opioid prescribing in patients prescribed vs not prescribed methocarbamol. RESULTS: 101 patients received methocarbamol compared with 202 without. Similar number of patients received an opioid prescription (87.1 vs 86.6%; p = 0.904). Study patients received significantly lower MME prescription at discharge (60 v 75; p = 0.021) with no difference in refills (12.5 vs 16.6%; p = 0.386). CONCLUSION: Addition of methocarbamol to a multimodal analgesic regimen after VHR facilitates reduction in prescribed opioid with no increase in refills.


Assuntos
Hérnia Ventral , Hérnia Incisional , Metocarbamol , Transtornos Relacionados ao Uso de Opioides , Humanos , Analgésicos Opioides/uso terapêutico , Metocarbamol/uso terapêutico , Hérnia Incisional/cirurgia , Padrões de Prática Médica , Hérnia Ventral/cirurgia , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/cirurgia , Herniorrafia , Estudos Retrospectivos
6.
Am J Surg ; 226(6): 813-816, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37385858

RESUMO

BACKGROUND: Multimodal analgesia is now a mainstay of perioperative care. Our aim is to assess the impact of adding methocarbamol on opioid use for patients undergoing primary ventral (umbilical and epigastric) hernia repair (PVHR) and inguinal hernia repair (IHR). METHODS: Retrospective review of patients undergoing PVHR and IHR who received methocarbamol, propensity score matched in a 2:1 fashion to patients not receiving methocarbamol. RESULTS: Fifty-two PVHR patients receiving methocarbamol were matched to 104 control patients. Study patients were prescribed fewer opioids (55.8 vs 90.4%; p < 0.001) and received lower MME (20 vs 50; p < 0.001), with no difference in refills or rescue opioids. For IHR, study patients received fewer prescriptions (67.3 vs 87.5%; p < 0.001) and received lower MME (25 vs 40; p < 0.001), with no difference in rescue opioid (5.9 vs 0%; p = 0.374). CONCLUSIONS: Methocarbamol significantly reduced opioid prescribing in patients undergoing PVHR and IHR without increasing the risk of refill or rescue opioid.


Assuntos
Hérnia Inguinal , Metocarbamol , Transtornos Relacionados ao Uso de Opioides , Humanos , Hérnia Inguinal/cirurgia , Analgésicos Opioides/uso terapêutico , Metocarbamol/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/cirurgia , Padrões de Prática Médica , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Herniorrafia , Estudos Retrospectivos
7.
Neurooncol Adv ; 5(1): vdad069, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324217

RESUMO

Background: Isocitrate dehydrogenase (IDH) mutations are thought to represent an early oncogenic event in glioma evolution, found with high penetrance across tumor cells; however, in rare cases, IDH mutation may exist only in a small subset of the total tumor cells (subclonal IDH mutation). Methods: We present 2 institutional cases with subclonal IDH1 R132H mutation. In addition, 2 large publicly available cohorts of IDH-mutant astrocytomas were mined for cases harboring subclonal IDH mutations (defined as tumor cell fraction with IDH mutation ≤0.67) and the clinical and molecular features of these subclonal cases were compared to clonal IDH-mutant astrocytomas. Results: Immunohistochemistry (IHC) performed on 2 institutional World Health Organization grade 4 IDH-mutant astrocytomas revealed only a minority of tumor cells in each case with IDH1 R132H mutant protein, and next-generation sequencing (NGS) revealed remarkably low IDH1 variant allele frequencies compared to other pathogenic mutations, including TP53 and/or ATRX. DNA methylation classified the first tumor as high-grade IDH-mutant astrocytoma with high confidence (0.98 scores). In the publicly available datasets, subclonal IDH mutation was present in 3.9% of IDH-mutant astrocytomas (18/466 tumors). Compared to clonal IDH-mutant astrocytomas (n = 156), subclonal cases demonstrated worse overall survival in grades 3 (P = .0106) and 4 (P = .0184). Conclusions: While rare, subclonal IDH1 mutations are present in a subset of IDH-mutant astrocytomas of all grades, which may lead to a mismatch between IHC results and genetic/epigenetic classification. These findings suggest a possible prognostic role of IDH mutation subclonality, and highlight the potential clinical utility of quantitative IDH1 mutation evaluation by IHC and NGS.

8.
Am Surg ; 89(9): 3771-3777, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37195287

RESUMO

INTRODUCTION: Perioperative opioid analgesia has been extensively reexamined during the opioid epidemic. Multiple studies have demonstrated over prescription of opioids, demonstrating the need for change in prescribing practices. A standard opioid prescribing protocol was implemented to evaluate opioid prescribing trends and practices. OBJECTIVES: To evaluate opioid use after primary ventral, inguinal, and incisional hernia repair and to assess clinical factors that may impact opioid prescribing and consumption. Secondary outcomes include the number of refills, patients without opioid requirement, difference in opioid use based on patient characteristics and adherence to prescribing protocol. METHODS: This is a prospective observational study examining patients undergoing inguinal, primary ventral and incisional hernias between February and November 2019. A standardized prescribing protocol was implemented and utilized for postoperative prescribing. All data was captured in the abdominal core health quality collaborative (ACHQC) and opioid use was standardized via morphine milligram equivalents (MME). RESULTS: 389 patients underwent primary ventral, incisional, and inguinal hernia repair, with a total of 285 included in the final analysis. 170 (59.6%) of patients reported zero opioid use postoperatively. Total opioid MME prescribed and high MME consumption were significantly higher after incisional hernia repair with a greater number of refills were required. Compliance with prescribing protocol resulted in lower MME prescription, but not actual lower MME consumption. CONCLUSIONS: Implementation of a standardized protocol for opioid prescribing after surgery decreases the total MME prescribed. Compliance with our protocol significantly reduced this disparity, which has the potential for decreasing abuse, misuse, and diversion of opioids by better estimating actual postoperative analgesic requirements.


Assuntos
Hérnia Ventral , Hérnia Incisional , Transtornos Relacionados ao Uso de Opioides , Humanos , Analgésicos Opioides/uso terapêutico , Morfina , Dor Pós-Operatória/tratamento farmacológico , Padrões de Prática Médica , Hérnia Ventral/cirurgia , Estudos Retrospectivos , Estudos Observacionais como Assunto
9.
J Robot Surg ; 17(3): 1021-1027, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36463373

RESUMO

Non-midline abdominal wall hernias present unique anatomic challenges, making repair more complex. The constraints of the peritoneal cavity, pelvis, and costal margin limit the utility of intraperitoneal mesh repair, and extra-peritoneal repairs have traditionally been performed using open techniques, often resulting in higher wound morbidity. Advances in minimally invasive surgery make visualization and dissection of such complex cases feasible, with all the attendant benefits of a minimally invasive over an open approach. In this study, we examined the use of the robotic platform to repair non-midline hernias. Retrospective review of all non-midline abdominal wall hernias was performed robotically at Prisma Health, excluding parastomal hernias. Study conducted and outcomes reported according to STROBE statement. Repair was performed in the retro-rectus (n = 3) or retro-rectus + transversus abdominis release (TAR) (n = 39), pre-peritoneal (n = 22), and intraperitoneal (n = 1). Mean hernia width was 9.4 cm, permanent synthetic mesh used for all repairs. Mean LOS was 1.5 days. Surgical-site occurrence (SSO) occurred in 49.2%, 78% of which were simple seroma. Three patients (4.6%) developed surgical-site infection (SSI). Two recurrences were identified with a mean follow-up of 11 mos. The robotic platform facilitates complex dissection to allow minimally invasive, extra-peritoneal repair of complex non-midline hernias. This approach overcomes the anatomic constraints of intraperitoneal mesh repair and the wound morbidity of open repair.


Assuntos
Hérnia Ventral , Procedimentos Cirúrgicos Robóticos , Humanos , Hérnia Ventral/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Herniorrafia/métodos , Telas Cirúrgicas , Músculos Abdominais/cirurgia , Estudos Retrospectivos
10.
J Surg Res ; 282: 109-117, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36270120

RESUMO

INTRODUCTION: Opioids are commonly prescribed beyond what is necessary to adequately manage postoperative pain, increasing the likelihood of chronic opioid use, pill diversion, and misuse. We sought to assess opioid utilization and patient-reported outcomes (PROs) in patients undergoing ventral hernia repair (VHR) following the implementation of a patient-tailored opioid prescribing guideline. METHODS: A patient-tailored opioid prescribing guideline was implemented in March of 2018 for patients undergoing inpatient VHR in a large regional healthcare system. We retrospectively assessed opioid utilization and patient-reported outcomes among patients who did (n = 42) and did not receive guideline-based care (n = 121) between March 2018 and December 2019. PROs, operative details, and patient characteristics were extracted from the Abdominal Core Health Quality Collaborative (ACHQC) registry data, and length-of-stay and prescription information were extracted from the electronic health record system at the healthcare institution. RESULTS: The milligram morphine equivalents (MME) prescribed at discharge was lower for patients receiving guideline-based care (Median = 65, interquartile range [IQR] = 50-75) than patients receiving standard care (Median = 100, IQR = 60-150). After adjusting for patient characteristics, the odds of receiving an opioid refill after discharge did not significantly differ between patient groups (P = 0.43). Patient Reported Outcomes Measurement Information System (PROMIS) pain scores and hernia-specific quality-of-life (HerQLes) scores at follow-up also did not differ between patients receiving guideline-based care (Mean PROMIS = 57.3; Mean HerQLes = 53.1) versus those that did not (Mean PROMIS = 56.7; Mean HerQLes = 46.6). CONCLUSIONS: Patients who received tailored, guideline-based opioid prescriptions were discharged with lower opioid dosages and did not require more opioid refills than patients receiving standard opioid prescriptions. Additionally, we found no differences in pain or quality-of-life scores after discharge, indicating the opioids prescribed under the guideline were sufficient for patients.


Assuntos
Analgésicos Opioides , Hérnia Ventral , Humanos , Analgésicos Opioides/uso terapêutico , Estudos Retrospectivos , Padrões de Prática Médica , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Hérnia Ventral/cirurgia
11.
Surg Endosc ; 36(12): 9403-9409, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35556167

RESUMO

BACKGROUND: The effect of skin closure technique on surgical site occurrences (SSO) after open abdominal wall reconstruction (AWR) with retromuscular polypropylene mesh placement is largely unknown. We hypothesize that layered subcuticular skin closure with cyanoacrylate skin adhesive is protective of surgical site infection compared to standard stapled closure. METHODS: A retrospective review utilizing the Abdominal Core Health Quality Collaborative (ACHQC) database of all patients at Prisma Health-Upstate. All patients with open abdominal wall reconstruction (AWR) of midline incisional hernia defects with retromuscular polypropylene mesh placement from January 2013 to February 2020 were included. Patient demographics, comorbidities, type of hernia repair with mesh location, method of skin closure, and SSOs were collected. Skin closure method was divided into two groups, reflecting a temporal change in practice: staples (historical control group) versus subcuticular suture with cyanoacrylate skin adhesive with/without polymer mesh tape (study group). Primary endpoint was SSI and SSO. Secondary endpoints were SSO or SSI requiring procedural intervention (SSOPI/SSIPI). Standard statistical methods were utilized. RESULTS: A total of 834 patients were analyzed, with 263 treated with stapled skin closure and 571 with subcuticular and adhesive closure. On univariate analysis, the incidence of SSI was significantly lower in the study group (11.8 vs 6.8%; p = 0.002), as was the need for SSIPI (11.8 vs 6.7%; p = 0.015). Rate of SSO was not significantly different between groups (28.1 vs 27.2%), but the rate of SSO requiring intervention was lower in the study group (14.1 vs 9.3%; p = 0.045). CONCLUSION: Layered skin closure technique, including subcuticular closure and adhesive, may reduce the risk of surgical site infection after open AWR. A prospective randomized trial is planned to confirm these findings.


Assuntos
Parede Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Ventral , Humanos , Telas Cirúrgicas/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Parede Abdominal/cirurgia , Estudos Prospectivos , Polipropilenos , Herniorrafia/métodos , Estudos Retrospectivos , Cianoacrilatos/uso terapêutico , Hérnia Ventral/complicações , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos
12.
Am J Surg ; 224(1 Pt A): 45-50, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34972540

RESUMO

BACKGROUND: Myofascial release (MFR) techniques, including retromuscular hernia repair, are often considered one-time repairs. We report recurrent ventral hernia repair (RVHR) in patients with prior MFR, focusing on redo-RM repair. METHODS: Retrospective analysis of all patients undergoing RVHR after prior MFR. Primary outcomes were operative time, surgical site infection (SSI), surgical site occurrence (SSO), and 20-month recurrence. RESULTS: 111 RVHR were performed after MFR. For patients with prior external oblique release (EOR, n = 31), transversus abdominis release (TAR) was used for repair in 13. For patients with prior TAR/PCS (posterior component separation) (n = 22), EOR (n = 2) and redo-TAR (n = 3) were employed with comparable results. Prior retromuscular (RM) repair was performed in 92 patients. Redo-RM (n = 32) and intraperitoneal onlay mesh (IPOM; n = 38) were most common. Operative time was longer for redo-RM. SSI (12.5 vs 7.9%), SSO (40.1 vs 39.5%), and recurrence (18.8 vs 16.2%) were similar for redo-RM and IPOM repair. CONCLUSION: RVHR after prior MFR does not preclude additional MFR. Redo-RM VHR outcomes are similar to those repaired with other techniques.


Assuntos
Hérnia Ventral , Músculos Abdominais/cirurgia , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Humanos , Terapia de Liberação Miofascial , Estudos Retrospectivos , Telas Cirúrgicas , Infecção da Ferida Cirúrgica/cirurgia
13.
Am Surg ; 86(9): 1083-1087, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32809844

RESUMO

INTRODUCTION: Robotic hiatal hernia repair offers potential advantages over traditional laparoscopy, most notably enhanced visualization, improved ergonomics, and articulating instruments. The clinical outcomes, however, have not been adequately evaluated. We report outcomes of laparoscopic and robotic hiatal hernia repairs. METHODS: A retrospective observational cohort study was performed of all hiatal hernia repairs performed from 2006 through 2019. Operative, demographic, and outcomes data were compared between laparoscopic and robotic groups. Discrete variables were analyzed with Chi-square of Fisher's exact test. Continuous variables were analyzed with Student's t test (mean) or Wilcoxon rank sum (medians). All analyses were performed using R statistical software. RESULTS: Laparoscopic repair was performed in 278 patients and robotic repair in 114. More recurrent hernias were repaired robotically (24.5% vs 12.9%, P = .08). Operative times were no different between groups (175 vs 179 minutes; P = .681). Robotic repair resulted in significantly shorter length of stay (LOS; 2.3 vs 3.3 days; P = .003). Rate of readmission was no different, and there were no differences in acute complications. For patients with at least 1 year of follow-up, recurrence rates were lower after robotic repair (13.3% vs 32.8%; P = .008); however, mean follow-up is significantly longer after laparoscopic repair (23.7 ± 28.4 vs 15.1 ± 14.9 months; P < .001). DISCUSSION: Robotic hiatal hernia repair offers technical advantages over laparoscopic repair with similar clinical outcomes.


Assuntos
Hérnia Hiatal/cirurgia , Herniorrafia/métodos , Laparoscopia/métodos , Robótica/métodos , Seguimentos , Humanos , Tempo de Internação/tendências , Duração da Cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
14.
Am Surg ; 86(8): 965-970, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32779472

RESUMO

BACKGROUND: Recent data on opioid consumption indicate that patients typically require far less than is prescribed. Prisma Health Upstate Hernia Center adopted standardized postoperative prescribing after hernia repair and began tracking patient-reported opioid utilization. The aim of this study is to evaluate patient opioid use after hernia repair in order to guide future prescribing. METHODS: All patients who underwent primary ventral (umbilical and epigastric), incisional, and inguinal hernia repair between February and May 2019 were reviewed. Patients reported the number of opioid pills taken at their first postoperative visit and documented either in the progress note or in the Americas Hernia Society Quality Collaborative (AHSQC) patient-reported outcomes (PRO) questionnaire. All demographic, operative, and outcomes data were captured prospectively in the AHSQC. Opioid use reported as milligram morphine equivalents (MME). RESULTS: A total of 162 surgeries were performed during the study period, and 107 had patient-reported opioid use for analysis. Inguinal hernia repair was performed in 36 patients, 10 primary ventral hernia repairs, and 61 incisional hernia repairs. No opioid use was reported in 63.9% of inguinal hernias, 60% of primary ventral hernias, and 20% of incisional hernias. Inguinal hernia patients consumed a mean of 10.5 MME, primary ventral patients 11 MME, and incisional hernia patients 78.5 MME. CONCLUSION: Patients require little to no opioid after primary ventral or inguinal hernia repair and opioid-free surgery is feasible. Incisional hernia is more heterogenous, but the majority of patients still required less opioid than previously thought.


Assuntos
Analgésicos Opioides/uso terapêutico , Uso de Medicamentos/estatística & dados numéricos , Hérnia Inguinal/cirurgia , Hérnia Ventral/cirurgia , Herniorrafia , Dor Pós-Operatória/tratamento farmacológico , Padrões de Prática Médica/tendências , Protocolos Clínicos , Humanos , Prescrição Inadequada/prevenção & controle , Prescrição Inadequada/tendências , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Autorrelato , Estados Unidos
15.
Am Surg ; 86(11): 1602-1606, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32833492

RESUMO

BACKGROUND: Increased recognition of the dangers of opioid analgesia has led to significant focus on strategies for reducing use through multimodal analgesia, enhanced recovery protocols, and standardized guidelines for prescribing. Our institution implemented a standard protocol for prescribing analgesics at discharge after ventral hernia repair (VHR). We hypothesize that this strategy significantly reduces opioid use. METHODS: A standardized protocol for discharge prescribing was implemented in March 2018. Patients were prescribed ibuprofen, acetaminophen, and opioids based on milligram morphine equivalent (MME) use the 24 hours prior to discharge. We retrospectively reviewed prescriptions of opioids for two 6-month periods-July-December 2017 (PRE) and July-December 2018 (POST)-for comparison using EPIC report and the South Carolina Prescription Monitoring Program. Analysis performed included Mann-Kendall linear trend test and Student's t-test for continuous variables. RESULTS: VHR was performed in 105 patients in the PRE and 75 patients in the POST group. Total MME prescribed decreased significantly from mean 322.7 + 261.3/median 225 (IQR 150-400) MME to 141.6 + 150.4/median 100 (50-184) MME (P < .001). This represents a 57% reduction in mean opioid MME prescriptions. Acetaminophen prescribing increased from 10% to 65%, and ibuprofen from 7.6% to 61.3%. Refills were prescribed in 21 patients (20%) during the PRE period, which decreased to 10.7% during the POST group (P = .141). Implementation of an evidence-based protocol significantly reduces opioid prescribing after VHR. DISCUSSION: A multimodal approach to postoperative pain management decreases the need for opioids. The additional implementation of an evidence-based prescribing protocol results in significant reduction of opioid use following VHR.


Assuntos
Analgésicos Opioides/uso terapêutico , Hérnia Ventral/cirurgia , Herniorrafia , Protocolos Clínicos , Prática Clínica Baseada em Evidências/métodos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Humanos , Manejo da Dor/métodos , Dor Pós-Operatória/tratamento farmacológico , Alta do Paciente , Estudos Retrospectivos
17.
Am J Surg ; 220(3): 751-756, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32035628

RESUMO

BACKGROUND: Prosthetic mesh infection (PMI) is a challenging complication of ventral hernia repair (VHR). The sparsity of data leaves only experience and judgment to guide surgical decision-making. METHODS: Retrospective review of patients diagnosed with PMI. Subsequent abdominal operation (SAO) constitutes any intraabdominal operation occurring after the index hernia repair prior to PMI presentation. Any mesh removal was considered salvage failure. Analysis was performed using Chi-square test, Fishers Exact, or Mann-Whitney U test. Analyses completed using R Version 3.0.2. RESULTS: We identified 213 instances of PMI. Most cases (58.7%) involved intraperitoneal mesh. Thirty-seven percent of patients had an SAO, only 25.3% of which were clean cases. Enteroprosthetic fistula occurred in 38 patients (17.8%). Mean time to presentation was 19.9 mos after index hernia repair or SAO for infection alone, and 48.1 mos when a fistula was present (p < 0.001). Percutaneous drainage was used to treat 29 cases, successfully in 10 (34.5%), 8 of which were macroporous polypropylene and 2 biologic mesh. Negative pressure wound therapy (NPWT) was used in 46 patients, but successful in only 16 (34.8%), all of which were macroporous polypropylene. Local wound care alone successfully salvaged only 16 of 85 meshes (18.8%), 13 of which were macroporous polypropylene. Macroporous polypropylene mesh was salvaged in 65% of cases overall, and 72.2% when in an extraperitoneal position. Mesh salvage was not possible in any case involving composite or PTFE mesh, and rarely for microporous polypropylene (7.7%) multifilament polyester (4.2%), or intraperitoneal mesh (2.4%). Closure of the defect after mesh removal significantly lowers recurrence rate (p < 0.001). CONCLUSION: PMI involving composite, PTFE, multifilament polyester, or microporous polypropylene mesh requires explantation in nearly all cases. Infected macroporous polypropylene mesh in an extraperitoneal position is salvageable in most cases. Furthermore, the risk of secondary mesh infection after SAO, particularly with intraperitoneal mesh, should be considered during index VHR.


Assuntos
Hérnia Ventral/cirurgia , Herniorrafia , Infecções Relacionadas à Prótese/terapia , Telas Cirúrgicas , Idoso , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres , Polipropilenos , Desenho de Prótese , Estudos Retrospectivos
18.
J Am Coll Surg ; 230(4): 405-413, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31954819

RESUMO

BACKGROUND: Controversy remains about appropriate mesh selection during ventral hernia repair (VHR) in a contaminated field. Fear of mesh infection has led to increased use of biologic and absorbable synthetic meshes rather than permanent synthetic mesh in these cases. We report the safety and efficacy of permanent synthetic mesh during contaminated VHR. STUDY DESIGN: Retrospective review of our database identified all cases of contaminated VHR from July 2007 to May 2019. Student's t-test and Wilcoxon rank sum were used to analyze continuous variables, and discrete variables with Fisher's or Kruskal-Wallis test. RESULTS: There were 541 contaminated cases: 245 clean-contaminated, 214 contaminated, and 82 dirty cases. Suture repair was performed in 46 patients, biologic mesh was used in 38, absorbable synthetic mesh in 55, and permanent synthetic mesh in 402. Mesh was extraperitoneal in 97% of cases. Incidence of surgical site infection in each group was 17.4%, 36.8%, 32.7%, and 14.2%, respectively (p < 0.001). Multivariate analysis showed no effect of mesh selection on risk of surgical site infection. Mesh was removed in 7 patients; 5 were permanent synthetic (1.2%), 1 was absorbable synthetic (1.8%), and 1 was biologic (2.6%). In 4 patients there was mesh-specific complication and the remaining meshes were removed during exploration for indications unrelated to the mesh. At a median follow-up of 30.2 months, recurrence occurred in 15.2% of patients and was significantly lower with permanent synthetic mesh. CONCLUSIONS: Permanent synthetic mesh placed in an extraperitoneal position is not only safe for VHR in a contaminated field, but it confers a significantly lower rate of surgical site infection and recurrence compared with biologic or bioabsorbable meshes.


Assuntos
Infecções Bacterianas/complicações , Hérnia Ventral/complicações , Hérnia Ventral/cirurgia , Herniorrafia , Telas Cirúrgicas , Infecção da Ferida Cirúrgica/epidemiologia , Idoso , Feminino , Herniorrafia/instrumentação , Herniorrafia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Resultado do Tratamento
19.
J Am Coll Surg ; 228(4): 680-686, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30630088

RESUMO

BACKGROUND: Major abdominal operations often requires postoperative opioid analgesia. However, there is growing recognition of the potential for abuse. We previously reported a significant reduction in opioid consumption after implementation of an Enhanced Recovery after Surgery protocol after ventral hernia repair focusing on opioid reduction. Epidural use was routine for postoperative pain control in this protocol. Recently, we have transitioned to transversus abdominis plane (TAP) block instead of epidural analgesia. We hypothesize that this modification reduces length of stay and lowers opioid use in ventral hernia repair. METHODS: All patients undergoing open ventral hernia repair were recorded prospectively in the Americas Hernia Society Quality Collaborative database. All patients receiving either TAP or epidural between February 2015 and March 2018 were identified. Additional review was performed to quantify opioid use in morphine milligram equivalents (MMEs). Primary outcomes were length of stay and opioid use. RESULTS: Epidural was used in 172 patients and TAP block in 74. There were no significant comorbidity differences between groups. The TAP group had a slightly higher BMI (33.6 kg/m2 vs 28.3 kg/m2) and slightly smaller hernias (8.8 cm vs 10.8 cm). There was no difference in 30-day surgical site infections. Hospital length of stay was significantly shorter with TAP block (2.4 vs 4.5 days; p < 0.001). Total MME requirements for patients receiving TAP block were lower than those with epidural during postoperative days 1 and 2 (mean 40 vs 54.1 MMEs; p = 0.033 and 36.1 vs 52.5 MMEs; p = 0.018). CONCLUSIONS: Use of TAP block significantly reduces length of stay and decreases opioid dose requirements in the early postoperative period compared with epidural analgesia.


Assuntos
Analgesia Epidural , Analgésicos Opioides/administração & dosagem , Hérnia Ventral/cirurgia , Herniorrafia , Tempo de Internação/estatística & dados numéricos , Bloqueio Nervoso , Dor Pós-Operatória/prevenção & controle , Músculos Abdominais/inervação , Adulto , Idoso , Analgésicos Opioides/uso terapêutico , Relação Dose-Resposta a Droga , Recuperação Pós-Cirúrgica Melhorada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/métodos , Transtornos Relacionados ao Uso de Opioides/etiologia , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Dor Pós-Operatória/tratamento farmacológico , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA