Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Neuroimaging ; 33(2): 279-288, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36495053

RESUMO

BACKGROUND AND PURPOSE: The purpose was to explore the effects of transcutaneous trigeminal nerve stimulation (TNS) on neurochemical concentrations (brainstem, anterior cingulate cortex [ACC], dorsolateral prefrontal cortex [DLPFC], ventromedial prefrontal cortex [VMPFC], and the posterior cingulate cortex [PCC]) using ultrahigh-field magnetic resonance spectroscopy. METHODS: This double-blinded study tested 32 healthy males (age: 25.4 ± 7.3 years) on two separate occasions where participants received either a 20-minute TNS or sham session. Participants were scanned at baseline and twice post-TNS/sham administration. RESULTS: There were no group differences in concentration changes of glutamate, gamma-aminobutyric acid, glutamine, myoinositol (mI), total N-acetylaspartate, total creatine (tCr), and total choline between the baseline scan and the first post-TNS/sham scan and between the first and second post-TNS/sham scan in the brainstem, ACC, DLPFC, VMPFC, and PCC. Between the baseline scan and the second post-TNS/sham scan, changes in tCr (mean difference = 0.280 mM [0.075 to 0.485], p = .026) and mI (mean difference = 0.662 mM [0.203 to 1.122], p = .026) in the DLPFC differed between groups. Post hoc analyses indicated that there was a decrease in tCr (mean change = -0.201 mM [-0.335 to -0.067], p = .003) and no change in mI (mean change = -0.327 mM [-0.737 to 0.083], p = .118) in the TNS group; conversely, there was no change in tCr (mean change = -0.100 mM [-0.074 to 0.274], p = .259) and an increase in mI (mean change = 0.347 mM [0.106 to 0.588], p = .005) in the sham group. CONCLUSION: These data demonstrate that a single session of unilateral TNS slightly decreased tCr concentrations in the DLPFC region.


Assuntos
Ácido Glutâmico , Glutamina , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Espectroscopia de Ressonância Magnética/métodos , Nervo Trigêmeo , Receptores de Antígenos de Linfócitos T
2.
Front Psychiatry ; 13: 802449, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35350427

RESUMO

Stress exposures and dysregulated responses to stress are implicated in psychiatric disorders of mood, anxiety, and cognition. Perceived stress, an individual's appraisal of experienced stress and ability for coping, relates to dysregulated functioning in resting state brain networks. Alterations in GABAergic function may underlie perceived stress-related functional dysregulation in resting state networks but this has not yet been explored. Therefore, the current study examined the association of perceived stress, via the Perceived Stress Scale (PSS), with prefrontal GABA levels and corresponding resting state functional connectivity (RSFC) alterations. Twelve women and five men, ages 35-61, participated. MR spectroscopy was used to measure brain GABA levels in the anterior cingulate cortex (ACC), left dorsolateral prefrontal cortex (DLPFC), and ventromedial prefrontal cortex (VMPFC). Resting state functional scans acquired at 3 Tesla were used to measure RSFC within and between the default mode (DMN), salience (SN), and central executive networks (CEN), hippocampus and amygdala. We observed significant negative correlations between total PSS scores and left DLPFC GABA levels (r = -0.62, p = 0.023). However, PSS scores were not significantly correlated with RSFC measures (all p > 0.148). These preliminary results support a relationship between perceived stress and GABAergic functioning in DLPFC, a core node of the CEN, an intrinsic network thought to underlie goal-directed attentional processes. Our findings extend previous work suggesting that functioning in the CEN is related to perceived stress and may inform treatment strategies to improve outcomes in stress-related conditions.

3.
J Child Neurol ; 36(13-14): 1162-1168, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33557675

RESUMO

Succinic semialdehyde dehydrogenase (SSADH) deficiency is an autosomal recessive disorder of γ-aminobutyric acid (GABA) degradation, resulting in elevations of brain GABA and γ-hydroxybutyric acid (GHB). Previous magnetic resonance (MR) spectroscopy studies have shown increased levels of Glx in SSADH deficiency patients. Here in this work, we measure brain GABA in a large cohort of SSADH deficiency patients using advanced MR spectroscopy techniques that allow separation of GABA from overlapping metabolite peaks. We observed significant increases in GABA concentrations in SSADH deficiency patients for all 3 brain regions that were evaluated. Although GABA levels were higher in all 3 regions, each region had different patterns in terms of GABA changes with respect to age. We also report results from structural magnetic resonance imaging (MRI) of the same cohort compared with age-matched controls. We consistently observed signal hyperintensities in globus pallidus and cerebellar dentate nucleus.


Assuntos
Erros Inatos do Metabolismo dos Aminoácidos/diagnóstico , Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Deficiências do Desenvolvimento/diagnóstico , Imageamento por Ressonância Magnética/métodos , Succinato-Semialdeído Desidrogenase/deficiência , Erros Inatos do Metabolismo dos Aminoácidos/diagnóstico por imagem , Criança , Estudos de Coortes , Deficiências do Desenvolvimento/diagnóstico por imagem , Humanos , Análise Espectral/métodos
4.
NMR Biomed ; 34(5): e4484, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33559967

RESUMO

The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post-processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta-analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full.


Assuntos
Consenso , Espectroscopia de Ressonância Magnética , Relatório de Pesquisa/normas , Prova Pericial , Humanos , Software
5.
J Head Trauma Rehabil ; 35(5): 342-353, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32881768

RESUMO

OBJECTIVE: To evaluate the strength of associations between single-task and dual-task gait measures and posterior cingulate gyrus (PCG) neurochemicals in acutely concussed collegiate athletes. SETTING: Participants were recruited from an NCAA Division 1 University. PARTICIPANTS: Nineteen collegiate athletes acutely (<4 days) following sports-related concussion. DESIGN: We acquired magnetic resonance spectroscopy (MRS) in the PCG and gait performance measurements in the participants, acutely following concussion. Linear mixed-effects models were constructed to measure the effect of gait performance, in the single- and dual-task settings, and sex on the 6 neurochemicals quantified with MRS in mmol. Correlation coefficients were also calculated to determine the direction and strength of the relationship between MRS neurochemicals and gait performance, postconcussion symptom score, and number of previous concussions. MAIN MEASURES: Average gait speed, average cadence, N-acetyl aspartate, choline, myo-inositol, glutathione, glutamate plus glutamine, and creatine. RESULTS: Single-task gait speed (P = .0056) and cadence (P = .0065) had significant effects on myo-inositol concentrations in the PCG, independent of sex, in concussed collegiate athletes. Single-task cadence (P = .047) also had a significant effect on glutathione in the PCG. No significant effects were observed between dual-task gait performance and PCG neurochemistry. CONCLUSIONS: These findings indicate that increased concentrations of neuroinflammatory markers in the PCG are associated with slower single-task gait performance within 4 days of sports-related concussion.


Assuntos
Traumatismos em Atletas , Concussão Encefálica , Marcha , Neuroquímica , Atletas , Traumatismos em Atletas/complicações , Traumatismos em Atletas/diagnóstico , Concussão Encefálica/complicações , Concussão Encefálica/diagnóstico , Feminino , Humanos , Masculino , Adulto Jovem
6.
Magn Reson Med ; 84(5): 2495-2511, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32367530

RESUMO

PURPOSE: The linear change of the water proton resonance frequency shift (PRFS) with temperature is used to monitor temperature change based on the temporal difference of image phase. Here, the effect of motion-induced susceptibility artifacts on the phase difference was studied in the context of mild radio frequency hyperthermia in the pelvis. METHODS: First, the respiratory-induced field variations were disentangled from digestive gas motion in the pelvis. The projection onto dipole fields (PDF) as well as the Laplacian boundary value (LBV) algorithm were applied on the phase difference data to eliminate motion-induced susceptibility artifacts. Both background field removal (BFR) algorithms were studied using simulations of susceptibility artifacts, a phantom heating experiment, and volunteer and patient heating data. RESULTS: Respiratory-induced field variations were negligible in the presence of the filled water bolus. Even though LBV and PDF showed comparable results for most data, LBV seemed more robust in our data sets. Some data sets suggested that PDF tends to overestimate the background field, thus removing phase attributed to temperature. The BFR methods even corrected for susceptibility variations induced by a subvoxel displacement of the phantom. The method yielded successful artifact correction in 2 out of 4 patient treatment data sets during the entire treatment duration of mild RF heating of cervical cancer. The heating pattern corresponded well with temperature probe data. CONCLUSION: The application of background field removal methods in PRFS-based MR thermometry has great potential in various heating applications and body regions to reduce motion-induced susceptibility artifacts that originate outside the region of interest, while conserving temperature-induced PRFS. In addition, BFR automatically removes up to a first-order spatial B0 drift.


Assuntos
Artefatos , Termometria , Humanos , Imageamento por Ressonância Magnética , Pelve/diagnóstico por imagem , Prótons
7.
Magn Reson Med ; 84(1): 11-24, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31828853

RESUMO

PURPOSE: To introduce a robust methodology for fast 1 H MRSI of the brain at 3T with improved SNR and reduced phase-related artifacts. METHOD: An accelerated acquisition scheme using echo-planar spectroscopic imaging (EPSI) was combined with the overdiscrete reconstruction framework. This approach enables the interleaved acquisition of a water reference scan at each phase encoding step, maximizing its correlation with the water-suppressed measurement. Moreover, a generalized high-order phase correction was incorporated into the reconstruction pipeline. The spatial-temporal phase correction term was estimated from the reference scan and interpolated to high resolution using a polynomial basis. The method was implemented at 3T and validated with phantom and in vivo experiments. RESULTS: The methodology showed the elimination of spectral artifacts generated by phase disturbances and achieved mean SNR gains in vivo of 3.18 and 1.19 compared to standard reconstructions with corrections performed at nominal and high resolution, respectively. EPSI scans with interleaved water acquisition showed to be robust to system instabilities and potentially to patient motion. Moreover, phase distortions were effectively corrected in a single step, avoiding additional reference measurements and post-processing steps. CONCLUSION: The overdiscrete reconstruction framework with high-order phase correction allowed to effectively correct for distortions, related to B0 inhomogeneities, B0 drift, eddy currents, and system vibrations. Furthermore, the presented reconstruction method, combined with EPSI acquisitions, demonstrated improved measurement stability, substantial SNR enhancement, better spectral linewidth, and effective artifact removal.


Assuntos
Artefatos , Imagem Ecoplanar , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
8.
NMR Biomed ; 31(11): e3950, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30052300

RESUMO

MR spectroscopic imaging (MRSI) at ultra-high field (≥7 T) benefits from improved sensitivity that allows the detection of low-concentration metabolites in the brain. However, optimized acquisition techniques are required to overcome inherent limitations of MRSI at ultra-high field. This work describes an optimized method for fast high-resolution 1 H-MRSI of the brain at 7 T. The proposed acquisition sequence combines precise volume localization using semi-localization by adiabatic selective refocusing, fast spatial encoding using high-bandwidth symmetric echo-planar spectroscopic imaging (EPSI), and robust water suppression with variable power and optimized relaxation delays. This showed improved robustness to B0 and B1+ inhomogeneities, eddy currents, nuisance signal contamination and system instabilities. Furthermore, a method for correction of phase inconsistencies in symmetric EPSI enabled high-bandwidth measurements at 7 T. The proposed correction effectively removed spectral ghosting using a single-shot water reference scan. This framework was tested in healthy volunteers at 7 T and spectral quality was compared with lower-spatial-resolution scans, measured at 3 T using the same methodology. A gain in the signal-to-noise ratio (SNR) per unit volume and unit time of 1.57 was achieved, keeping acquisition time short (5 min) and the specific absorption rate within the permitted limits. This SNR enhancement obtained at ultra-high field enabled high-resolution (0.25-0.375 mL) metabolite mapping of the brain within a clinically feasible scan time. The correlation of the reconstructed maps with anatomical structures was observed, showing the diagnostic potential of the technique.


Assuntos
Imagem Ecoplanar , Colina/metabolismo , Creatina/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Metaboloma , Razão Sinal-Ruído
9.
Eur J Radiol ; 89: 27-32, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267545

RESUMO

X-Ray Phase-Contrast (XPC) imaging is a novel technology with a great potential for applications in clinical practice, with breast imaging being of special interest. This work introduces an intuitive methodology to combine and visualize relevant diagnostic features, present in the X-ray attenuation, phase shift and scattering information retrieved in XPC imaging, using a Fourier domain fusion algorithm. The method allows to present complementary information from the three acquired signals in one single image, minimizing the noise component and maintaining visual similarity to a conventional X-ray image, but with noticeable enhancement in diagnostic features, details and resolution. Radiologists experienced in mammography applied the image fusion method to XPC measurements of mastectomy samples and evaluated the feature content of each input and the fused image. This assessment validated that the combination of all the relevant diagnostic features, contained in the XPC images, was present in the fused image as well.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Análise de Fourier , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Adulto , Algoritmos , Feminino , Humanos , Reprodutibilidade dos Testes , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA