Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
JACC Cardiovasc Imaging ; 17(8): 865-876, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39001730

RESUMO

BACKGROUND: Global longitudinal strain (GLS) is reported to be more reproducible and prognostic than ejection fraction. Automated, transparent methods may increase trust and uptake. OBJECTIVES: The authors developed open machine-learning-based GLS methodology and validate it using multiexpert consensus from the Unity UK Echocardiography AI Collaborative. METHODS: We trained a multi-image neural network (Unity-GLS) to identify annulus, apex, and endocardial curve on 6,819 apical 4-, 2-, and 3-chamber images. The external validation dataset comprised those 3 views from 100 echocardiograms. End-systolic and -diastolic frames were each labelled by 11 experts to form consensus tracings and points. They also ordered the echocardiograms by visual grading of longitudinal function. One expert calculated global strain using 2 proprietary packages. RESULTS: The median GLS, averaged across the 11 individual experts, was -16.1 (IQR: -19.3 to -12.5). Using each case's expert consensus measurement as the reference standard, individual expert measurements had a median absolute error of 2.00 GLS units. In comparison, the errors of the machine methods were: Unity-GLS 1.3, proprietary A 2.5, proprietary B 2.2. The correlations with the expert consensus values were for individual experts 0.85, Unity-GLS 0.91, proprietary A 0.73, proprietary B 0.79. Using the multiexpert visual ranking as the reference, individual expert strain measurements found a median rank correlation of 0.72, Unity-GLS 0.77, proprietary A 0.70, and proprietary B 0.74. CONCLUSIONS: Our open-source approach to calculating GLS agrees with experts' consensus as strongly as the individual expert measurements and proprietary machine solutions. The training data, code, and trained networks are freely available online.


Assuntos
Consenso , Ecocardiografia , Interpretação de Imagem Assistida por Computador , Aprendizado de Máquina , Redes Neurais de Computação , Valor Preditivo dos Testes , Humanos , Fenômenos Biomecânicos , Conjuntos de Dados como Assunto , Deformação Longitudinal Global , Contração Miocárdica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Reino Unido , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
2.
J Cardiovasc Magn Reson ; : 101067, 2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39079601

RESUMO

BACKGROUND: Accurate measurements from cardiac magnetic resonance (CMR) images require precise positioning of scan planes and elimination of movement artefacts from arrhythmia or breathing. Unidentified or incorrectly managed artefacts degrade image quality, invalidate clinical measurements and decrease diagnostic confidence. Currently, radiographers must manually inspect each acquired image to confirm diagnostic quality and decide whether reacquisition or a change in sequences is warranted. We aimed to develop an artificial intelligence (AI) to provide continuous quality scores across different quality domains, and from these, determine whether cines are clinically adequate, require replanning, or warrant a change in protocol. METHODS: A three-dimensional convolutional neural network was trained to predict cine quality graded on a continuous scale by a level 3 CMR expert, focusing separately on planning and movement artefacts. It incorporated four distinct output heads for the assessment of image quality in terms of: (a, b, c)2-, 3- and 4-chamber misplanning, and (d)long- and short-axis arrhythmia/breathing artefact. Back-propagation was selectively performed across these heads based on the labels present for each cine. Each image in the testing set was reported by four level 3 CMR experts, providing a consensus on clinical adequacy. The AI's assessment of image quality and ability to identify images requiring replanning or sequence changes were evaluated with Spearman's rho and the area under receiver operating characteristic (AUROC) respectively. RESULTS: A total of 1940 cines across 1387 studies were included. On the test set of 383 cines, AI-judged image quality correlated strongly with expert judgement, with Spearman's rho of 0.84, 0.84, 0.81 and 0.81 for 2-, 3- and 4-chamber planning quality and the extent of arrhythmia or breathing artefacts, respectively. The AI also showed high efficacy in flagging clinically inadequate cines (AUROC 0.88, 0.93, 0.93 and for identifying replanning of 2-, 3- and 4-chamber cines, and 0.90 for identifying movement artefacts). CONCLUSION: AI can assess distinct domains of CMR cine quality and provide continuous quality scores that correlate closely with a consensus of experts. These ratings could be used to identify cases where reacquisition is warranted, and guide corrective actions to optimise image quality, including replanning, prospective gating, or real-time imaging.

3.
Echo Res Pract ; 11(1): 16, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825710

RESUMO

Impairment of left ventricular (LV) diastolic function is common amongst those with left heart disease and is associated with significant morbidity. Given that, in simple terms, the ventricle can only eject the volume with which it fills and that approximately one half of hospitalisations for heart failure (HF) are in those with normal/'preserved' left ventricular ejection fraction (HFpEF) (Bianco et al. in JACC Cardiovasc Imaging. 13:258-271, 2020. 10.1016/j.jcmg.2018.12.035), where abnormalities of ventricular filling are the cause of symptoms, it is clear that the assessment of left ventricular diastolic function (LVDF) is crucial for understanding global cardiac function and for identifying the wider effects of disease processes. Invasive methods of measuring LV relaxation and filling pressures are considered the gold-standard for investigating diastolic function. However, the high temporal resolution of trans-thoracic echocardiography (TTE) with widely validated and reproducible measures available at the patient's bedside and without the need for invasive procedures involving ionising radiation have established echocardiography as the primary imaging modality. The comprehensive assessment of LVDF is therefore a fundamental element of the standard TTE (Robinson et al. in Echo Res Pract7:G59-G93, 2020. 10.1530/ERP-20-0026). However, the echocardiographic assessment of diastolic function is complex. In the broadest and most basic terms, ventricular diastole comprises an early filling phase when blood is drawn, by suction, into the ventricle as it rapidly recoils and lengthens following the preceding systolic contraction and shortening. This is followed in late diastole by distension of the compliant LV when atrial contraction actively contributes to ventricular filling. When LVDF is normal, ventricular filling is achieved at low pressure both at rest and during exertion. However, this basic description merely summarises the complex physiology that enables the diastolic process and defines it according to the mechanical method by which the ventricles fill, overlooking the myocardial function, properties of chamber compliance and pressure differentials that determine the capacity for LV filling. Unlike ventricular systolic function where single parameters are utilised to define myocardial performance (LV ejection fraction (LVEF) and Global Longitudinal Strain (GLS)), the assessment of diastolic function relies on the interpretation of multiple myocardial and blood-flow velocity parameters, along with left atrial (LA) size and function, in order to diagnose the presence and degree of impairment. The echocardiographic assessment of diastolic function is therefore multifaceted and complex, requiring an algorithmic approach that incorporates parameters of myocardial relaxation/recoil, chamber compliance and function under variable loading conditions and the intra-cavity pressures under which these processes occur. This guideline outlines a structured approach to the assessment of diastolic function and includes recommendations for the assessment of LV relaxation and filling pressures. Non-routine echocardiographic measures are described alongside guidance for application in specific circumstances. Provocative methods for revealing increased filling pressure on exertion are described and novel and emerging modalities considered. For rapid access to the core recommendations of the diastolic guideline, a quick-reference guide (additional file 1) accompanies the main guideline document. This describes in very brief detail the diastolic investigation in each patient group and includes all algorithms and core reference tables.

4.
J Am Coll Cardiol ; 84(1): 1-12, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38752902

RESUMO

BACKGROUND: In stable coronary artery disease, 30% to 60% of patients remain symptomatic despite successful revascularization. Perhaps not all symptoms reported by a patient with myocardial ischemia are, in fact, angina. OBJECTIVES: This study sought to determine whether independent symptom verification using a placebo-controlled ischemic stimulus could distinguish which patients achieve greatest symptom relief from percutaneous coronary intervention (PCI). METHODS: ORBITA-STAR was a multicenter, n-of-1, placebo-controlled study in patients undergoing single-vessel PCI for stable symptoms. Participants underwent 4 episodes (60 seconds each) of low-pressure balloon occlusion across their coronary stenosis, randomly paired with 4 episodes of placebo inflation. Following each episode, patients reported the similarity of the induced symptom in comparison with their usual symptom. The similarity score ranged from -10 (placebo replicated the symptom more than balloon occlusion) to +10 (balloon occlusion exactly replicated the symptom). The primary endpoint was the ability of the similarity score to predict symptom relief with PCI. RESULTS: Fifty-one patients were recruited, aged 62.9 ± 8.6 years. The median fractional flow reserve was 0.68 (Q1-Q3: 0.57-0.79), and the instantaneous wave-free ratio was 0.80 (Q1-Q3: 0.48-0.89). The median similarity score was 3 (Q1-Q3: 0.875-5.25). The similarity score was a strong predictor of symptom improvement following PCI: a patient with an upper quartile similarity score of 5.25 was significantly more likely to have lower angina frequency at follow-up (OR: 8.01; 95% credible interval: 2.39-15.86) than a patient with a lower quartile similarity score of 0.875 (OR: 1.31; 95% credible interval: 0.71-1.99), Pr(difference) >99.9%. CONCLUSIONS: Similarity score powerfully predicted symptom improvement from PCI. These data lay the foundation for independent symptom mapping to target PCI to those patients most likely to benefit. (Systematic Trial of Angina Assessment Before Revascularization [ORBITA-STAR]; NCT04280575).


Assuntos
Angina Pectoris , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Intervenção Coronária Percutânea/métodos , Angina Pectoris/terapia , Idoso , Resultado do Tratamento
5.
J Am Coll Cardiol ; 84(1): 13-24, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38759906

RESUMO

BACKGROUND: Placebo-controlled evidence from ORBITA-2 (Objective Randomised Blinded Investigation with Optimal Medical Therapy of Angioplasty in Stable Angina-2) found that percutaneous coronary intervention (PCI) in stable coronary artery disease with little or no antianginal medication relieved angina, but residual symptoms persisted in many patients. The reason for this was unclear. OBJECTIVES: This ORBITA-2 secondary analysis investigates the relationship between presenting symptoms and disease severity (anatomic, noninvasive, and invasive ischemia) and the ability of symptoms to predict the placebo-controlled efficacy of PCI. METHODS: Prerandomization symptom severity and nature were assessed using the ORBITA smartphone application and symptom and quality of life questionnaires including the World Health Organization Rose angina questionnaire (Rose). Disease severity was assessed using quantitative coronary angiography, stress echocardiography, fractional flow reserve, and instantaneous wave-free ratio. Bayesian ordinal regression was used. RESULTS: At prerandomization, the median number of daily angina episodes was 0.8 (Q1-Q3: 0.4-1.6), 64% had Rose angina, quantitative coronary angiography diameter stenosis was 61% (Q1-Q3: 49%-74%), stress echocardiography score was 1.0 (Q1-Q3: 0.0-2.7), fractional flow reserve was 0.63 (Q1-Q3: 0.49-0.75), and instantaneous wave-free ratio was 0.78 (Q1-Q3: 0.55-0.87). There was little relationship between symptom severity and nature and disease severity: angina symptom score with quantitative coronary angiography ordinal correlation coefficient: 0.06 (95% credible interval [CrI]: 0.00-0.08); stress echocardiography: 0.09 (95% CrI: 0.02-0.10); fractional flow reserve: 0.04 (95% CrI: -0.03 to 0.07); and instantaneous wave-free ratio: 0.04 (95% CrI: -0.01 to 0.07). However, Rose angina and guideline-based typical angina were strong predictors of placebo-controlled PCI efficacy (angina symptom score: OR: 1.9; 95% CrI: 1.6-2.1; probability of interaction [PrInteraction] = 99.9%; and OR: 1.8; 95% CrI: 1.6-2.1; PrInteraction = 99.9%, respectively). CONCLUSIONS: Although symptom severity and nature were poorly associated with disease severity, the nature of symptoms powerfully predicted the placebo-controlled efficacy of PCI.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Idoso , Resultado do Tratamento , Angiografia Coronária , Índice de Gravidade de Doença , Angina Estável/terapia , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Qualidade de Vida
6.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38604209

RESUMO

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/terapia , Angina Estável/tratamento farmacológico , Seio Coronário/diagnóstico por imagem , Teorema de Bayes , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Método Duplo-Cego , Isquemia , Adenosina
7.
J Cardiovasc Magn Reson ; 26(1): 101040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38522522

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports. METHODS: Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (70:15:15). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center. RESULTS: One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86. CONCLUSION: Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.


Assuntos
Meios de Contraste , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Meios de Contraste/administração & dosagem , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/normas , Bases de Dados Factuais , Miocárdio/patologia , Masculino , Feminino , Imagem Cinética por Ressonância Magnética/normas , Pessoa de Meia-Idade , Cardiopatias/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Variações Dependentes do Observador , Idoso , Imageamento por Ressonância Magnética/normas
8.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38214677

RESUMO

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Angina Estável/diagnóstico , Qualidade de Vida , Seio Coronário/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/terapia
9.
J Cardiovasc Magn Reson ; 26(1): 100005, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211656

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging is an important tool for evaluating the severity of aortic stenosis (AS), co-existing aortic disease, and concurrent myocardial abnormalities. Acquiring this additional information requires protocol adaptations and additional scanner time, but is not necessary for the majority of patients who do not have AS. We observed that the relative signal intensity of blood in the ascending aorta on a balanced steady state free precession (bSSFP) 3-chamber cine was often reduced in those with significant aortic stenosis. We investigated whether this effect could be quantified and used to predict AS severity in comparison to existing gold-standard measurements. METHODS: Multi-centre, multi-vendor retrospective analysis of patients with AS undergoing CMR and transthoracic echocardiography (TTE). Blood signal intensity was measured in a ∼1 cm2 region of interest (ROI) in the aorta and left ventricle (LV) in the 3-chamber bSSFP cine. Because signal intensity varied across patients and scanner vendors, a ratio of the mean signal intensity in the aorta ROI to the LV ROI (Ao:LV) was used. This ratio was compared using Pearson correlations against TTE parameters of AS severity: aortic valve peak velocity, mean pressure gradient and the dimensionless index. The study also assessed whether field strength (1.5 T vs. 3 T) and patient characteristics (presence of bicuspid aortic valves (BAV), dilated aortic root and low flow states) altered this signal relationship. RESULTS: 314 patients (median age 69 [IQR 57-77], 64% male) who had undergone both CMR and TTE were studied; 84 had severe AS, 78 had moderate AS, 66 had mild AS and 86 without AS were studied as a comparator group. The median time between CMR and TTE was 12 weeks (IQR 4-26). The Ao:LV ratio at 1.5 T strongly correlated with peak velocity (r = -0.796, p = 0.001), peak gradient (r = -0.772, p = 0.001) and dimensionless index (r = 0.743, p = 0.001). An Ao:LV ratio of < 0.86 was 84% sensitive and 82% specific for detecting AS of any severity and a ratio of 0.58 was 83% sensitive and 92% specific for severe AS. The ability of Ao:LV ratio to predict AS severity remained for patients with bicuspid aortic valves, dilated aortic root or low indexed stroke volume. The relationship between Ao:LV ratio and AS severity was weaker at 3 T. CONCLUSIONS: The Ao:LV ratio, derived from bSSFP 3-chamber cine images, shows a good correlation with existing measures of AS severity. It demonstrates utility at 1.5 T and offers an easily calculable metric that can be used at the time of scanning or automated to identify on an adaptive basis which patients benefit from dedicated imaging to assess which patients should have additional sequences to assess AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Função Ventricular Esquerda , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Valva Aórtica/anormalidades , Reprodutibilidade dos Testes , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Interpretação de Imagem Assistida por Computador , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Fluxo Sanguíneo Regional , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA