Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 4512-4515, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441354

RESUMO

The CH-VAD is a centrifugal-flow magnetically levitated (maglev) left ventricular assist device (LVAD) used to treat end-stage heart failure. It is implanted in the chest cavity; the inflow cannula is inserted into the apex of the left ventricle, and the outflow graft is anastomosed to the aorta. Among several key VAD system improvements, the CH-VAD has a smaller body size than other LVADs and its maglev system offers a large-gap design that makes it superior in terms of hemocompatibility. In this study, we implanted the CH-VAD in a calf and evaluated the hemodynamic and hemocompatibility characteristics over a 14-day period. The hemodynamic parameters, the pump data, and blood test results were recorded throughout the study. The results showed that the CH-VAD provided hemodynamic stability. Hemocompatibility testing indicated negligible hemolysis throughout the study, and no signs of infection were seen. On necropsy, the results showed only expected focal mild-to-moderate adhesions between the pericardial sac (along the pump) and the adjacent rib cage, and between the pericardial sac and the heart. Gross examination of internal organs was unremarkable. Examination of the CH-VAD after explantation revealed no evidence of thrombus formation internally or around the inflow or outflow cannulas.


Assuntos
Coração Auxiliar , Hemodinâmica , Animais , Aorta , Bovinos , Insuficiência Cardíaca/terapia , Ventrículos do Coração
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 4520-4523, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441356

RESUMO

We are designing an intra-atrial pump (IAP) that will be affixed to the atrial septum and support the compromised left ventricle (LV) in patients with early-stage heart failure without harming the ventricular tissue. It will operate in parallel with the LV, drawing blood from the left atrium and unloading the LV. In previous hydraulic and hemodynamic studies, different blade geometries were tested for the IAP, and the hemodynamic results obtained using a mock circulatory loop showed that the IAP can successfully reduce end-diastolic volume and increase the total systemic flow rate. In the current study, we used a bovine model to validate the in vitro hemodynamic results and better understand how the IAP interacts with the cardiovascular system in vivo. Because this was the first study assessing the complete device in a living system, it was also necessary to determine the best manufacturing techniques and ideal sensor placements. In the bovine model, we were able to successfully implant the IAP across the atrial septum with the outflow graft connected to a peripheral artery. The implanted IAP was capable of providing partial support (1-3 L/min) in vivo. These results indicate that atrial cannulation is feasible and creates a beneficial hemodynamic environment.


Assuntos
Ventrículos do Coração , Coração Auxiliar , Animais , Cateterismo , Bovinos , Estudos de Viabilidade , Átrios do Coração , Hemodinâmica , Humanos , Função Ventricular Esquerda
3.
ASAIO J ; 62(6): 697-703, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27442861

RESUMO

In a previous study, we showed that the Vitalmex Extracorporeal Ventricular Assist Device-Pneumatic (EVAD-P)-a low-cost, pneumatically actuated, pulsatile blood pump-is easy to implant and safe for short-term in vivo support (30 ± 5 days). In the current study, we included additional 30 day experiments and assessed the safety and durability of the EVAD-P for up to 90 days of support. Using the same surgical procedure as in the previous study, we implanted the device into 14 healthy sheep. Group I subjects (n = 7) were evaluated for up to 30 days, and group II (n = 2) and group III (n = 5) subjects were evaluated for up to 49 and 93 days, respectively. After a system redesign, two of the five sheep in group III reached the scheduled end-point without device-related problems at a fixed beat rate of 56 bpm, a stroke volume (SV) of 58.0 ± 2.3 ml, and a flow of 3.5 ± 0.2 L/min. This study shows that the EVAD-P can provide safe pulsatile mechanical circulatory support (MCS) for up to 93 days. To further confirm that the system can consistently provide MCS for this duration, additional studies are recommended.


Assuntos
Coração Auxiliar , Animais , Ovinos , Volume Sistólico
4.
Eur J Cardiothorac Surg ; 42(1): 149-54, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22362620

RESUMO

OBJECTIVE: To increase applicability and stability of aortic valve repair, a three-dimensional aortic annuloplasty ring has been developed for intra-annular placement. The goal of this study was to test the safety of this device with in vivo implantation in the calf model. METHODS: In 10 chronic calves, the HAART annuloplasty ring was sutured to the aortic valve annulus using cardiopulmonary bypass. The animals were recovered and followed for 1-2 months. Serial echocardiography was used to evaluate valve competence, and contrast aortograms and CT angiograms were obtained in selected animals. After completion of follow-up, each animal was euthanized, and aortic endoscopy was performed under water distension in five. Full autopsies with histologic examinations were performed. RESULTS: All animals survived surgery. Two were euthanized in the first week for complications, and the remaining eight calves were followed uneventfully for the 1-2 months. Serial echocardiography showed completely competent valves in all but one animal, in which the ring was intentionally up-sized to test the sizing strategy. Contrast aortographic and CT angiographic findings were similar to the echocardiograms. Postmortem examination showed proper seating of all rings with endothelialization at 1-2 months. All valves demonstrated good leaflet coaptation and no abnormalities. CONCLUSIONS: In vivo testing of a three-dimensional aortic annuloplasty ring in a chronic calf model proved to be very successful and safe. Using the sizing and implant strategies developed, human trials seem indicated.


Assuntos
Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Animais , Valva Aórtica/diagnóstico por imagem , Bovinos , Segurança de Equipamentos , Seguimentos , Modelos Animais , Radiografia , Ultrassonografia
5.
ASAIO J ; 55(5): 456-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19672192

RESUMO

Chronic ventilatory support may be required for survival after total artificial heart (TAH) implantation in calves. However, prolonged or repeated intubation may negatively affect a calf's ability to eat, drink, ruminate, and stand after surgery. To mitigate these limitations, we performed tracheotomies on 23 consecutive calves at the time of TAH implantation. The tracheostomies served as the primary route for ventilatory support and airway management. Tracheostomies were left in place for up to 25 days (mean, 7 +/- 7 days) and were well tolerated. Prolonged presence of a tracheostomy facilitated cleaning of the airway secretions and did not inhibit the calf's ability to stand, eat, or drink. The calves survived from 2 to 49 days (mean, 8 days). Twenty-two calves that maintained their tracheostomies died of causes unrelated to airway management. The calf that had the tracheostomy removed on day 25 died of respiratory arrest on day 49. At necropsy, we found that severe tracheal stenosis had developed at the tracheostomy site. In calves, an elective tracheotomy can be a valuable adjunct to TAH implantation or other procedures that might require prolonged ventilatory support or airway access, but care should be exercised if the tracheostomy is removed to ensure that the calf does not develop late tracheal stenosis.


Assuntos
Coração Artificial/efeitos adversos , Respiração Artificial/métodos , Insuficiência Respiratória/cirurgia , Traqueotomia , Animais , Bovinos
6.
ASAIO J ; 53(3): 392-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17515735

RESUMO

We evaluated the effects of the Levitronix UltraMag pediatric ventricular assist system on healthy animals during 29- to 90-day periods by assessing hemocompatibility and hepatic and renal functions while operating the device in a flow range suitable for pediatric patients. Nine lambs (weight, 15 to 24 kg) received the Levitronix UltraMag with an outflow cannula anastomosed to the descending aorta and an inflow cannula inserted into the left ventricular apex. Pump function data were collected at 1-hour intervals, and postoperative hematology and clinical chemistry tests were performed weekly throughout the study. Complete necropsy and histopathologic examinations were performed at study termination. Pump and circuit were thoroughly inspected for evidence of thrombi. All animals reached the scheduled endpoint of 29 to 90 days without device-related problems. Mean flow was maintained at 1.14 +/- 0.19 L/min. Hematologic values were within normal range in all animals except in one lamb that had a severe hemolytic reaction after cefazolin sodium administration. In all animals, serum glutamic-oxaloacetic transaminase and creatinine kinase levels increased after surgery but gradually returned to normal limits within 1 week. Postmortem examination of the explanted organs revealed small infarcted areas in five lamb kidneys, but renal function was unaffected. All other major organs were unremarkable. In one explanted pump (a 30-day study), a small thrombus was seen within the impeller blade. The other eight pumps were free of thrombus. The Levitronix UltraMag successfully operated in pediatric flow ranges without device-related adverse events.


Assuntos
Débito Cardíaco , Cateterismo/métodos , Coração Auxiliar , Implantação de Prótese , Animais , Tamanho Corporal , Criança , Coração Auxiliar/efeitos adversos , Hematócrito , Hemoglobinas , Humanos , Testes de Função Renal , Testes de Função Hepática , Modelos Animais , Contagem de Plaquetas , Ovinos , Trombose/etiologia
7.
ASAIO J ; 51(2): 139-43, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15839437

RESUMO

We assessed the effects of an axial flow left ventricular assist device (LVAD) upon aortic valve opening, pump outflow, and biologic and hematologic parameters when operated in intermittent low speed (ILS) mode. An ILS controller equipped Jarvik 2000 LVAD was implanted in six calves. Pump speed was maintained at 10,000 rpm, and pump outflow was measured throughout the study period (71 +/- 6 days [mean +/- SD]). Hematologic and biochemical parameters were analyzed daily for the first 10 days, weekly for the first month, and biweekly thereafter to monitor for kidney or liver dysfunction, hemolysis, bleeding, or infection. Before study termination, esmolol hydrochloride was infused to induce low cardiac output and totally impair aortic valve opening. Radiopaque cineaortography was performed over 30 second intervals (10 seconds before, 10 seconds during, and 10 seconds immediately after ILS controller activation) to assess the effect of ILS mode upon aortic valve opening. After study termination, major end organs and the major vascular tree were removed and examined macroscopically and histologically for thrombus formation and infarction; the aortic valve was examined for thickening and fusion. All pumps were explanted and examined for thrombus formation. All six calves recovered without surgical or mechanical complications. Hematologic and biochemical parameters did not change significantly between baseline and study termination. The aortic valve successfully opened when ILS mode was activated, even under low cardiac output conditions. No thrombus was detected in the major end organs and vascular tree, except for some small renal infarcts in three calves that did not affect renal function. These results indicate that operating an axial flow LVAD in ILS mode allows aortic valve opening and aortic root washout.


Assuntos
Valva Aórtica/fisiopatologia , Coração Auxiliar , Animais , Valva Aórtica/diagnóstico por imagem , Débito Cardíaco , Bovinos , Cineangiografia , Coração Auxiliar/efeitos adversos , Infarto/etiologia , Rim/irrigação sanguínea
8.
ASAIO J ; 50(5): 444-50, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15497383

RESUMO

The Jarvik 2000 ventricular assist device (VAD) is clinically efficacious for treating end-stage left ventricular failure. Because simultaneous right ventricular support is also occasionally necessary, we developed a biventricular Jarvik 2000 technique and tested it in a calf model. One VAD was implanted in the left ventricle with outflow-graft anastomosis to the descending aorta. The other VAD was implanted in the right ventricle with outflow-graft anastomosis to the pulmonary artery. Throughout the 30 day study, hemodynamic values were continuously monitored. On day 30, both pumps were evaluated at different speeds, under various hemodynamic conditions. By gradually occluding the pulmonary artery proximally or distally, we simulated varying degrees of high pulmonary vascular resistance, right ventricular hypertension, global heart failure, or ventricular fibrillation. The two VADs maintained biventricular support even during pulmonary artery occlusion and ventricular fibrillation, yielding a cardiac output of 3-11 L/min, left ventricular end-diastolic pressure of 11-24 mm Hg, and central venous pressure of 9-25 mm Hg. End-organ function was unimpaired, and no major adverse events occurred. The dual VADs offered safe, effective biventricular assistance in the calf. Additional studies are needed to assess the effects of lowered pulse pressure upon the pulmonary circulation and to develop a single pump speed controller.


Assuntos
Ventrículos do Coração/cirurgia , Coração Auxiliar , Hipertensão Pulmonar/terapia , Animais , Débito Cardíaco/fisiologia , Bovinos , Modelos Animais de Doenças , Implantação de Prótese
9.
ASAIO J ; 50(3): 267-71, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15171480

RESUMO

The experimental calf model is used to assess mechanical circulatory support devices and prosthetic heart valves. Baseline indices of cardiac function have been established for the normal awake calf but not for the anesthetized calf. Therefore, we gathered hemodynamic and echocardiographic data from 16 healthy anesthetized calves (mean age, 189.0 +/- 87.0 days; mean body weight, 106.9 +/- 32.3 kg) by cardiac catheterization and noninvasive echocardiography, respectively. Baseline hemodynamic data included heart rate (65 +/- 12 beats per minute), mean aortic pressure (113.5 +/- 17.4 mm Hg), left ventricular end-diastolic pressure (16.3 +/- 38.9 mm Hg), and mean pulmonary artery pressure (21.7 +/- 8.3 mm Hg). Baseline two-dimensional echocardiographic data included left ventricular systolic dimension (3.5 +/- 0.7 cm), left ventricular diastolic dimension (5.6 +/- 0.8 cm), end-systolic intraventricular septal thickness (1.7 +/- 0.2 cm), end-diastolic intraventricular septal thickness (1.2 +/- 0.2 cm), ejection fraction (63 +/- 10%), and fractional shortening (37 +/- 10%). Doppler echocardiography revealed a maximum aortic valve velocity of 0.9 +/- 0.5 m/s and a cardiac index of 3.7 +/- 1.1 L/minute/m2. The collected baseline data will be useful in assessing prosthetic heart valves, cardiac assist pumps, new cannulation techniques, and robotics applications in the anesthetized calf model and in developing calf models of various cardiovascular diseases.


Assuntos
Anestésicos Dissociativos/farmacologia , Ecocardiografia Doppler/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Ketamina/farmacologia , Animais , Cateterismo Cardíaco , Bovinos , Feminino , Masculino , Padrões de Referência
10.
ASAIO J ; 50(1): 47-53, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14763491

RESUMO

The Jarvik 2000 axial flow left ventricular assist device (LVAD) is used clinically as a bridge to transplantation or as destination therapy in end-stage heart disease. The effect of the pump's continuous flow output on myocardial and end-organ blood flow has not been studied experimentally. To address this, the Jarvik 2000 pump was implanted in eight calves and then operated at speeds ranging from 8,000 to 12,000 rpm. Micromanometry, echocardiography, and blood oxygenation measurements were used to assess changes in hemodynamics, cardiac dimensions, and myocardial metabolism, respectively, at different speeds as compared with baseline (pump off, 0 rpm) in this experimental model. Microsphere studies were performed to assess the effects on heart, kidney, and brain perfusion at different speeds. The Jarvik 2000 pump unloaded the left ventricle and reduced end-diastolic pressures and left ventricular dimensions, particularly at higher pump speeds. The ratio of myocardial oxygen consumption to coronary blood flow and the ratio of subendocardial to subepicardial blood flow remained constant. Optimal adjustment of pump speed and volume status allowed opening of the aortic valve and contribution of the native left ventricle to cardiac output, even at the maximum pump speed. Neither brain nor kidney microcirculation was adversely affected at any pump speed. We conclude that the Jarvik 2000 pump adequately unloads the left ventricle without compromising myocardial metabolism or end-organ perfusion.


Assuntos
Coração Auxiliar , Animais , Engenharia Biomédica , Fenômenos Fisiológicos Cardiovasculares , Bovinos , Ecocardiografia , Hemodinâmica , Miocárdio/metabolismo , Especificidade de Órgãos , Consumo de Oxigênio , Fluxo Sanguíneo Regional , Função Ventricular Esquerda
11.
Ann Thorac Surg ; 77(1): 196-202, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14726061

RESUMO

BACKGROUND: The bileaflet valve is currently the mechanical replacement valve of choice. Though durable, it does not closely mimic native valve hemodynamics and remains potentially thrombogenic. METHODS: Prototype trileaflet valves (T1 and T2) were implanted in the mitral position in calves. Group I calves received either a T1 valve (n = 12) or a control bileaflet valve (n = 5); Group II, either a T2 valve (n = 7) or a control bileaflet valve (n = 5). Valve function, perivalvular leakage, and transvalvular pressure gradients were evaluated. Also, long-term prototype leaflet wear was evaluated in vivo in one Group I calf (502 days) and two Group II calves (385 and 366 days). Calves were euthanized and necropsied at study termination, and major organs weighed and examined. RESULTS: Valve function was excellent and hematologic parameters remained normal in all calves that survived to study termination. Mean peak transvalvular pressure gradients were 10 +/- 7 mm Hg for T1 valves, 6 +/- 3 mm Hg for T2 valves, and 12 +/- 4 mm Hg for bileaflet control valves. Clinically insignificant valvular regurgitation was observed in both prototypes. Explanted valves showed no thrombus-impaired leaflet motion, except in two T1-fitted calves and one T2-fitted calf. Major organs showed no evidence of clinically significant thromboembolic events. There were no other significant differences between the results of experimental and control groups. CONCLUSIONS: Prototype trileaflet valves performed safely and effectively in the mitral position in calves, even without long-term anticoagulation. This warrants their evaluation as an equivalent alternative to bileaflet valves.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Animais , Bovinos , Próteses Valvulares Cardíacas/efeitos adversos , Testes Hematológicos , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Ultrassonografia