Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Clin Microbiol ; 61(3): e0147822, 2023 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-36757183

RESUMO

While the goal of universal drug susceptibility testing has been a key component of the WHO End TB Strategy, in practice, this remains inaccessible to many. Rapid molecular tests for tuberculosis (TB) and antituberculosis drug resistance could significantly improve access to testing. In this study, we evaluated the accuracy of the Akonni Biosystems XDR-TB (extensively drug-resistant TB) TruArray and lateral-flow-cell (XDR-LFC) assay (Akonni Biosystems, Inc., Frederick, MD, USA), a novel assay that detects mutations in seven genes associated with resistance to antituberculosis drugs: katG, the inhA promoter, and the ahpC promoter for isoniazid; rpoB for rifampin; gyrA for fluoroquinolones; rrs and the eis promoter for kanamycin; and rrs for capreomycin and amikacin. We evaluated assay performance using direct sputum samples from 566 participants recruited in a prospective cohort in Moldova over 2 years. The sensitivity and specificity against the phenotypic reference were both 100% for isoniazid, 99.2% and 97.9% for rifampin, 84.8% and 99.1% for fluoroquinolones, 87.0% and 84.1% for kanamycin, 54.3% and 100% for capreomycin, and 79.2% and 100% for amikacin, respectively. Whole-genome sequencing data for a subsample of 272 isolates showed 95 to 99% concordance with the XDR-LFC-reported suspected mutations. The XDR-LFC assay demonstrated a high level of accuracy for multiple drugs and met the WHO's minimum target product profile criteria for isoniazid and rifampin, while the sensitivity for fluoroquinolones and amikacin fell below target thresholds, likely due to the absence of a gyrB target in the assay. With optimization, the XDR-LFC shows promise as a novel near-patient technology to rapidly diagnose drug-resistant tuberculosis.


Assuntos
Tuberculose Extensivamente Resistente a Medicamentos , Mycobacterium tuberculosis , Tuberculose Resistente a Múltiplos Medicamentos , Humanos , Canamicina , Isoniazida/farmacologia , Capreomicina , Amicacina/farmacologia , Rifampina/farmacologia , Fluoroquinolonas/farmacologia , Testes de Sensibilidade Microbiana , Estudos Prospectivos , Proteínas de Bactérias/genética , Farmacorresistência Bacteriana Múltipla/genética , Antituberculosos/farmacologia , Antituberculosos/uso terapêutico , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Extensivamente Resistente a Medicamentos/diagnóstico , Tuberculose Extensivamente Resistente a Medicamentos/tratamento farmacológico
2.
J Clin Tuberc Other Mycobact Dis ; 27: 100304, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35252594

RESUMO

While there has been progress in detection of drug resistant tuberculosis globally, WHO estimates only about half of the patients with bacteriologically confirmed tuberculosis were tested for rifampicin resistance over the past two years. To close this drug resistance diagnostic gap, an expansion of testing for rifampicin and isoniazid resistance is critically needed. The Akonni Biosystem Integrated System combines DNA extraction and a Lab-on-a-Film assembly (LFA) to perform rapid probe and PCR-based detection of resistance associated mutations to first-line anti-tuberculosis drugs. Using raw sputum samples from 25 tuberculosis patients at risk for drug resistance, we conducted a proof-of-concept study of the Integrated System with an MDR-TB assay. Performance of the Integrated System was compared to liquid Mycobacteria Growth Indicator Tube (MGIT) culture reference phenotypes using 2012 WHO endorsed critical concentrations for rifampicin and isoniazid. The overall percent agreement for rifampicin and isoniazid was 91.7% and 100% respectively, with agreement for rifampicin increasing to 95.7% after low-level resistance mutations in rpoB were excluded. The Integrated System, combining DNA extraction and LFA amplification, is a promising new tool for detection of both rifampicin and isoniazid using liquefied raw sputum.

3.
J Clin Microbiol ; 58(11)2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-32817085

RESUMO

Despite the WHO's call for universal drug susceptibility testing for all patients being evaluated for tuberculosis (TB), a lack of rapid diagnostic tests which can fully describe TB resistance patterns is a major challenge in ensuring that all persons diagnosed with drug-resistant TB are started on an appropriate treatment regime. We evaluated the accuracy of the Akonni Biosystems XDR-TB TruArray and lateral-flow cell (XDR-LFC), a novel multiplex assay to simultaneously detect mutations across seven genes that confer resistance to both first- and second-line anti-TB drugs. The XDR-LFC includes 271 discrete three-dimensional gel elements with target-specific probes for identifying mutations in katG, inhA promoter, and ahpC promoter (isoniazid), rpoB (rifampin), gyrA (fluoroquinolones), rrs and eis promoter (kanamycin), and rrs (capreomycin and amikacin). We evaluated XDR-LFC performance with 87 phenotypically and genotypically characterized clinical Mycobacterium tuberculosis isolates. The overall assay levels of accuracy for mutation detection in specific genes were 98.6% for eis promoter and 100.0% for the genes katG, inhA promoter, ahpC promoter, rpoB, gyrA, and rrs The sensitivity and specificity against phenotypic reference were 100% and 100% for isoniazid, 98.4% and 50% for rifampin (specificity increased to 100% once the strains with documented low-level resistance mutations in rpoB were excluded), 96.2% and 100% for fluoroquinolones, 92.6% and 100% for kanamycin, 93.9% and 97.4% for capreomycin, and 80% and 100% for amikacin. The XDR-LFC solution appears to be a promising new tool for accurate detection of resistance to both first- and second-line anti-TB drugs.


Assuntos
Mycobacterium tuberculosis , Tuberculose Resistente a Múltiplos Medicamentos , Antituberculosos/farmacologia , Antituberculosos/uso terapêutico , Proteínas de Bactérias/genética , Farmacorresistência Bacteriana Múltipla , Humanos , Laboratórios , Testes de Sensibilidade Microbiana , Mutação , Mycobacterium tuberculosis/genética , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico
4.
Anal Chem ; 92(7): 5311-5318, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32142258

RESUMO

Automated genotyping of drug-resistant Mycobacterium tuberculosis (MTB) directly from sputum is challenging for three primary reasons. First, the sample matrix, sputum, is highly viscous and heterogeneous, posing a challenge for sample processing. Second, acid-fast MTB bacilli are difficult to lyse. And third, there are hundreds of MTB mutations that confer drug resistance. An additional constraint is that MTB is most prevalent where test affordability is paramount. We address the challenge of sample homogenization and cell lysis using magnetic rotation of an external magnet, at high (5000) rpm, to induce the rotation of a disposable stir disc that causes chaotic mixing of glass beads ("MagVor"). Nucleic acid is purified using a pipet tip with an embedded matrix that isolates nucleic acid ("TruTip"). We address the challenge of cost and genotyping multiple mutations using 203 porous three-dimensional gel elements printed on a film substrate and enclosed in a microfluidic laminate assembly ("Lab-on-a-Film"). This Lab-on-a-Film assembly (LFA) serves as a platform for amplification, hybridization, washing, and fluorescent imaging, while maintaining a closed format to prevent amplicon contamination of the workspace. We integrated and automated MagVor homogenization, TruTip purification, and LFA amplification in a multisample, sputum-to-genotype system. Using this system, we report detection down to 43 cfu/mL of MTB bacilli from raw sputum.


Assuntos
Automação , Dispositivos Lab-On-A-Chip , Mycobacterium tuberculosis/genética , Imagem Óptica , Escarro/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico por imagem , Genótipo , Humanos , Imagem Óptica/instrumentação
6.
Lab Chip ; 19(7): 1217-1225, 2019 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-30801596

RESUMO

We describe a Lab-on-a-Film disposable that detects multidrug-resistant tuberculosis (MDR-TB) from sputum extracts. The Lab-on-a-Film disposable consists of 203 gel elements that include DNA sequences (probes) for 37 mutations, deletions, or insertion elements across 5 genes (including an internal control). These gel elements are printed on a flexible film, which costs approximately 500 times less than microarray glass. The film with printed gel elements is then laminated to additional rollable materials (films) to form a microfluidic flow cell. We combined multiplex amplification and hybridization steps in a single microfluidic chamber, without buffer exchanges or other manipulations up to and throughout hybridization. This flow cell also incorporates post hybridization wash steps while retaining an entirely closed-amplicon system, thus minimizing the potential for sample or amplicon cross-contamination. We report analytical sensitivity of 32 cfu mL-1 across all MDR-TB markers and detection of MDR-TB positive clinical specimens using an automated TruTip workstation for extraction and the Lab-on-a-Film disposable for amplification and detection of the extracts.


Assuntos
Equipamentos Descartáveis , Resistência a Múltiplos Medicamentos/genética , Técnicas de Genotipagem/instrumentação , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Escarro/microbiologia , Humanos
7.
PLoS One ; 13(7): e0199869, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29975759

RESUMO

Automated nucleic acid extraction from primary (raw) sputum continues to be a significant technical challenge for molecular diagnostics. In this work, we developed a prototype open-architecture, automated nucleic acid workstation that includes a mechanical homogenization and lysis function integrated with heating and TruTip purification; optimized an extraction protocol for raw sputum; and evaluated system performance on primary clinical specimens. Eight samples could be processed within 70 min. The system efficiently homogenized primary sputa and doubled nucleic acid recovery relative to an automated protocol that did not incorporate sample homogenization. Nucleic acid recovery was at least five times higher from raw sputum as compared to that of matched sediments regardless of smear or culture grade, and the automated workstation reproducibly recovered PCR-detectable DNA to at least 80 CFU mL-1 raw sputum. M. tuberculosis DNA was recovered and detected from 122/123 (99.2%) and 124/124 (100%) primary sputum and sediment extracts, respectively. There was no detectable cross-contamination across 53 automated system runs and amplification or fluorescent inhibitors (if present) were not detectable. The open fluidic architecture of the prototype automated workstation yields purified sputum DNA that can be used for any molecular diagnostic test. The ability to transfer TruTip protocols between personalized, on-demand pipetting tools and the fully automated workstation also affords public health agencies an opportunity to standardize sputum nucleic acid sample preparation procedures, reagents, and quality control across multiple levels of the health care system.


Assuntos
DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Mycobacterium tuberculosis/genética , Manejo de Espécimes/métodos , Escarro/microbiologia , Tuberculose/diagnóstico , Tuberculose/microbiologia , Automação Laboratorial , Humanos , Mycobacterium tuberculosis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico
8.
J Microbiol Methods ; 148: 174-180, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29678500

RESUMO

Systems that automate extraction of nucleic acid from cells or viruses in complex clinical matrices have tremendous value even in the absence of an integrated downstream detector. We describe our bench-top automated workstation that integrates our previously-reported extraction method - TruTip - with our newly-developed mechanical lysis method. This is the first report of this method for homogenizing viscous and heterogeneous samples and lysing difficult-to-disrupt cells using "MagVor": a rotating magnet that rotates a miniature stir disk amidst glass beads confined inside of a disposable tube. Using this system, we demonstrate automated nucleic acid extraction from methicillin-resistant Staphylococcus aureus (MRSA) in nasopharyngeal aspirate (NPA), influenza A in nasopharyngeal swabs (NPS), human genomic DNA from whole blood, and Mycobacterium tuberculosis in NPA. The automated workstation yields nucleic acid with comparable extraction efficiency to manual protocols, which include commercially-available Qiagen spin column kits, across each of these sample types. This work expands the scope of applications beyond previous reports of TruTip to include difficult-to-disrupt cell types and automates the process, including a method for removal of organics, inside a compact bench-top workstation.


Assuntos
Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Ácidos Nucleicos/isolamento & purificação , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Células Sanguíneas/química , Misturas Complexas/isolamento & purificação , Humanos , Vírus da Influenza A/química , Staphylococcus aureus Resistente à Meticilina/química , Mycobacterium tuberculosis/química
9.
J Clin Microbiol ; 56(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29305543

RESUMO

There is a growing awareness that molecular diagnostics for detect-to-treat applications will soon need a highly multiplexed mutation detection and identification capability. In this study, we converted an open-amplicon microarray hybridization test for multidrug-resistant (MDR) Mycobacterium tuberculosis into an entirely closed-amplicon consumable (an amplification microarray) and evaluated its performance with matched sputum and sediment extracts. Reproducible genotyping (the limit of detection) was achieved with ∼25 M. tuberculosis genomes (100 fg of M. tuberculosis DNA) per reaction; the estimated shelf life of the test was at least 18 months when it was stored at 4°C. The test detected M. tuberculosis in 99.1% of sputum extracts and 100% of sediment extracts and showed 100% concordance with the results of real-time PCR. The levels of concordance between M. tuberculosis and resistance-associated gene detection were 99.1% and 98.4% for sputum and sediment extracts, respectively. Genotyping results were 100% concordant between sputum and sediment extracts. Relative to the results of culture-based drug susceptibility testing, the test was 97.1% specific and 75.0% sensitive for the detection of rifampin resistance in both sputum and sediment extracts. The specificity for the detection of isoniazid (INH) resistance was 98.4% and 96.8% for sputum and sediment extracts, respectively, and the sensitivity for the detection of INH resistance was 63.6%. The amplification microarray reported the correct genotype for all discordant phenotype/genotype results. On the basis of these data, primary sputum may be considered a preferred specimen for the test. The amplification microarray design, shelf life, and analytical performance metrics are well aligned with consensus product profiles for next-generation drug-resistant M. tuberculosis diagnostics and represent a significant ease-of-use advantage over other hybridization-based tests for diagnosing MDR tuberculosis.


Assuntos
Técnicas de Genotipagem/métodos , Sedimentos Geológicos/microbiologia , Mycobacterium tuberculosis/genética , Análise de Sequência com Séries de Oligonucleotídeos , Escarro/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Antituberculosos/farmacologia , Farmacorresistência Bacteriana Múltipla/genética , Genes MDR/genética , Genótipo , Humanos , Isoniazida/farmacologia , Testes de Sensibilidade Microbiana , Técnicas Analíticas Microfluídicas , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Rifampina/farmacologia , Sensibilidade e Especificidade
10.
J Vis Exp ; (86)2014 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-24796567

RESUMO

Simplifying microarray workflow is a necessary first step for creating MDR-TB microarray-based diagnostics that can be routinely used in lower-resource environments. An amplification microarray combines asymmetric PCR amplification, target size selection, target labeling, and microarray hybridization within a single solution and into a single microfluidic chamber. A batch processing method is demonstrated with a 9-plex asymmetric master mix and low-density gel element microarray for genotyping multi-drug resistant Mycobacterium tuberculosis (MDR-TB). The protocol described here can be completed in 6 hr and provide correct genotyping with at least 1,000 cell equivalents of genomic DNA. Incorporating on-chip wash steps is feasible, which will result in an entirely closed amplicon method and system. The extent of multiplexing with an amplification microarray is ultimately constrained by the number of primer pairs that can be combined into a single master mix and still achieve desired sensitivity and specificity performance metrics, rather than the number of probes that are immobilized on the array. Likewise, the total analysis time can be shortened or lengthened depending on the specific intended use, research question, and desired limits of detection. Nevertheless, the general approach significantly streamlines microarray workflow for the end user by reducing the number of manually intensive and time-consuming processing steps, and provides a simplified biochemical and microfluidic path for translating microarray-based diagnostics into routine clinical practice.


Assuntos
Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase/métodos , Farmacorresistência Bacteriana Múltipla , Tuberculose/microbiologia
11.
Clin Chim Acta ; 429: 198-205, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24360850

RESUMO

BACKGROUND: Genetic polymorphisms in the CYP2C9 and VKORC1 genes have been linked to sensitivity of the anticoagulant drug warfarin. The aim of this study is to demonstrate a method for warfarin sensitivity genotyping using gel element microarray technology in a simplified workflow from sample collection to analysis and detection. METHODS: We developed an integrated amplification microarray system combining PCR amplification, target labeling, and microarray hybridization within a single, closed-amplicon "lateral flow cell" for genotyping three single nucleotide polymorphisms (SNPs) that influence warfarin response. We combined nucleic acid extraction of saliva using the TruTip technology together with the lateral flow cell assay and with fully automated array detection and analysis. RESULTS: The analytical performance of the assay was tested using 20 genotyped human genomic DNA samples and found to be sensitive down to 330 input genomic copies (1 ng). A follow-up pre-clinical evaluation was performed with 65 blinded saliva samples and the genotyping results were in agreement with those determined by bidirectional sequencing. CONCLUSIONS: Combined with the use of non-invasive saliva samples, rapid DNA extraction, the lateral flow cell, automatic imaging and data analysis provides a simple and fast sample-to-answer microarray test for warfarin sensitivity genotyping.


Assuntos
Técnicas de Genotipagem/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Reação em Cadeia da Polimerase/métodos , Saliva/citologia , Saliva/metabolismo , Varfarina/farmacologia , Alelos , Hidrocarboneto de Aril Hidroxilases/genética , Citocromo P-450 CYP2C9 , Humanos , Polimorfismo de Nucleotídeo Único , Integração de Sistemas , Vitamina K Epóxido Redutases/genética
12.
J Clin Virol ; 58(1): 138-43, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23880159

RESUMO

BACKGROUND: Rapid, simple and efficient influenza RNA purification from clinical samples is essential for sensitive molecular detection of influenza infection. Automation of the TruTip extraction method can increase sample throughput while maintaining performance. OBJECTIVES: To automate TruTip influenza RNA extraction using an Eppendorf epMotion robotic liquid handler, and to compare its performance to the bioMerieux easyMAG and Qiagen QIAcube instruments. STUDY DESIGN: Extraction efficacy and reproducibility of the automated TruTip/epMotion protocol was assessed from influenza-negative respiratory samples spiked with influenza A and B viruses. Clinical extraction performance from 170 influenza A and B-positive respiratory swabs was also evaluated and compared using influenza A and B real-time RT-PCR assays. RESULTS: TruTip/epMotion extraction efficacy was 100% in influenza virus-spiked samples with at least 745 influenza A and 370 influenza B input gene copies per extraction, and exhibited high reproducibility over four log10 concentrations of virus (<1% CV). RNA yields between the three automated methods differed by less than 0.5 log10 gene copies. 99% of clinical specimens that were PCR-positive after easyMAG or QIAcube extraction were also positive following TruTip extraction. Overall Ct value differences obtained between TruTip/epMotion and easyMAG/QIAcube clinical extracts ranged from 1.24 to 1.91. Pairwise comparisons of Ct values showed a high correlation of the TruTip/epMotion protocol to the other methods (R2>0.90). CONCLUSION: The automated TruTip/epMotion protocol is a simple and rapid extraction method that reproducibly purifies influenza RNA from respiratory swabs, with comparable efficacy and efficiency to both the easyMAG and QIAcube instruments.


Assuntos
Automação Laboratorial/métodos , Influenza Humana/diagnóstico , Orthomyxoviridae/genética , RNA Viral/isolamento & purificação , Sistema Respiratório/virologia , Manejo de Espécimes/métodos , Humanos , Orthomyxoviridae/isolamento & purificação , RNA Viral/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
13.
J Vis Exp ; (76): e50356, 2013 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-23793016

RESUMO

TruTip is a simple nucleic acid extraction technology whereby a porous, monolithic binding matrix is inserted into a pipette tip. The geometry of the monolith can be adapted for specific pipette tips ranging in volume from 1.0 to 5.0 ml. The large porosity of the monolith enables viscous or complex samples to readily pass through it with minimal fluidic backpressure. Bi-directional flow maximizes residence time between the monolith and sample, and enables large sample volumes to be processed within a single TruTip. The fundamental steps, irrespective of sample volume or TruTip geometry, include cell lysis, nucleic acid binding to the inner pores of the TruTip monolith, washing away unbound sample components and lysis buffers, and eluting purified and concentrated nucleic acids into an appropriate buffer. The attributes and adaptability of TruTip are demonstrated in three automated clinical sample processing protocols using an Eppendorf epMotion 5070, Hamilton STAR and STARplus liquid handling robots, including RNA isolation from nasopharyngeal aspirate, genomic DNA isolation from whole blood, and fetal DNA extraction and enrichment from large volumes of maternal plasma (respectively).


Assuntos
DNA/isolamento & purificação , Ensaios de Triagem em Larga Escala/métodos , RNA/isolamento & purificação , DNA/sangue , Feminino , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Masculino , Líquido da Lavagem Nasal/química , Nasofaringe/metabolismo , RNA/sangue , Robótica/instrumentação , Robótica/métodos
14.
J Virol Methods ; 183(1): 8-13, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22425698

RESUMO

This report describes the development and pre-clinical testing of a new, random-access RNA sample preparation system (TruTip) for nasopharyngeal samples. The system is based on a monolithic, porous nucleic acid binding matrix embedded within an aerosol-resistant pipette tip and can be operated with single or multi-channel pipettors. Equivalent extraction efficiencies were obtained between automated QIAcube and manual TruTip methods at 10(6) gene copies influenza A per mL nasopharyngeal aspirate. Influenza A and B amended into nasopharyngeal swabs (in viral transport medium) were detected by real-time RT-PCR at approximately 745 and 370 gene copies per extraction, respectively. RNA extraction efficiency in nasopharyngeal swabs was also comparable to that obtained on an automated QIAcube instrument over a range of input concentrations; the correlation between threshold cycles (or nucleic acid recovery) for TruTip and QIAcube-purified RNA was R(2)>0.99. Preclinical testing of TruTip on blinded nasopharyngeal swab samples resulted in 98% detection accuracy relative to a clinically validated easyMAG extraction method. The physical properties of the TruTip binding matrix and ability to customize its shape and dimensions likewise make it amenable to automation and/or fluidic integration.


Assuntos
Vírus da Influenza A/genética , Vírus da Influenza B/genética , Nasofaringe/virologia , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos , Virologia/métodos , Animais , Humanos
15.
Biomed Microdevices ; 14(1): 45-53, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21909803

RESUMO

Clinical laboratories are recognizing the importance of implementing sensitive and specific molecular diagnostic tests. However, widespread adoption of these tests requires simplified workflows without requiring expensive supporting instrumentation. To enable microarray-based analysis to meet these requirements, we describe a valveless flow cell for disposable use that supports PCR coupled with microarray hybridization in the same chamber. The flow cell assembly consists simply of double-faced tape, a plastic microarray substrate, an absorbent, and a commercially-available hydrophilic thin film. The simple construction lends itself to low-cost and ease of manufacturing, yet several features reduce the complexity of the standard microarray workflow. First, there is no requirement for custom instrumentation. Second, the hydrophilic thin film allows uniform filling of a microfluidic chamber. Third, a geometric capillary stop design confines liquid to the microarray chamber during PCR, and thus eliminates the need for a valve or hydrophobic surface treatment. And fourth, imbibition drives the uniform removal of liquid reagents from the array chamber. Three hundred genomic copies of methicillin-resistant Staphylococcus aureus (MRSA) are detected in a flow cell with gel drop microarrays printed on an unmodified plastic substrate. This sensitivity is shown to be comparable to conventional methods (i.e., PCR in a tube, with separate hybridization in a microarray chamber, where amplicon is exposed to the workspace before and after hybridization). However, the flow cell combines these multiple steps into a simple, compact workflow without the need for complex valves or custom instrumentation and is less susceptible to contamination of the workspace than conventional methods because the amplicon is confined to the device.


Assuntos
Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas Analíticas Microfluídicas , Análise de Sequência com Séries de Oligonucleotídeos , Reação em Cadeia da Polimerase/métodos
16.
Microarrays (Basel) ; 1(3): 107-24, 2012 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-27605339

RESUMO

This overview describes microarray-based tests that combine solution-phase amplification chemistry and microarray hybridization within a single microfluidic chamber. The integrated biochemical approach improves microarray workflow for diagnostic applications by reducing the number of steps and minimizing the potential for sample or amplicon cross-contamination. Examples described herein illustrate a basic, integrated approach for DNA and RNA genomes, and a simple consumable architecture for incorporating wash steps while retaining an entirely closed system. It is anticipated that integrated microarray biochemistry will provide an opportunity to significantly reduce the complexity and cost of microarray consumables, equipment, and workflow, which in turn will enable a broader spectrum of users to exploit the intrinsic multiplexing power of microarrays for infectious disease diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA