1.
J Biomed Mater Res ; 56(1): 109-19, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11309797

RESUMO

Calcium phosphate ceramic (CPC)-coated strain gauges have been used for in vivo bone strain measurements for up to 18 weeks, but they require 6 to 9 weeks for sufficient bonding. Osteogenic protein-1 (OP-1), PepTite (a proprietary ligand), calcium sulfate dihydrate (CSD), transforming growth factor beta-1 (TGF-beta1 ), and an endothelial cell layer with and without TGF-beta1 were used as surface enhancements to accelerate bone-to-CPC bonding. Young male Sprague-Dawley rats were implanted with unenhanced and enhanced CPC-coated gauges. Animals were allowed normal activity for 3 weeks and then calcein labeled. Femurs were explanted following euthanasia. A gauge was attached with cyanoacrylate to the opposite femur in the same position as the CPC-coated gauge. Bones were cantilever-loaded to assess strain transfer. They were sectioned and stained with mineralized bone stain (MIBS) and examined with transmitted and ultraviolet light. Mechanical testing indicated increased sensing accuracy for TGF-beta1 and OP-1 enhancements to 105 +/- 14% and 92 +/- 12% versus 52 +/- 44% for the unenhanced gauges. The PepTite and the endothelial-cell-layer-enhanced gauges showed lower sensing accuracy, and histology revealed a vascular layer near CPC particles. TGF-beta1 increased bone formation when used prior to endothelial cell sodding. CSD prevented strain transfer to the femur. TGF-beta1 and OP-1 surface enhancements produced accurate in vivo strain sensing on the rat femur after 3 weeks.


Assuntos
Materiais Biocompatíveis , Proteínas Morfogenéticas Ósseas/farmacologia , Fosfatos de Cálcio , Sulfato de Cálcio/farmacologia , Cerâmica , Materiais Revestidos Biocompatíveis , Endotélio/efeitos dos fármacos , Endotélio/fisiologia , Fêmur/efeitos dos fármacos , Fator de Crescimento Transformador beta/farmacologia , Animais , Proteína Morfogenética Óssea 7 , Endotélio/citologia , Fêmur/anatomia & histologia , Seguimentos , Cinética , Ligantes , Masculino , Teste de Materiais , Ratos , Ratos Sprague-Dawley , Estresse Mecânico , Propriedades de Superfície , Fator de Crescimento Transformador beta1
2.
J Biomed Mater Res ; 58(2): 147-55, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11241333

RESUMO

The finite element method was used to simulate strain transfer from bone to a calcium phosphate ceramic (CPC) coated strain gauge. The model was constructed using gross morphometric and histological measurements obtained from previous experimental studies. Material properties were assigned based on experiments and information from the literature. Boundary conditions simulated experimental cantilever loading of rat femora. The model was validated using analytical solutions based on the theory of elasticity as well as direct comparison to experimental data obtained in a separate study. The interface between the bone and strain gauge sensing surface consisted of layers of polysulfone, polysulfone/CPC, and CPC/bone. Parameter studies examined the effect of interface thickness and modulus, gauge geometry, partial gauge debonding, and waterproofing on the strain transfer from the bone to the gauge sensing element. Results demonstrated that interface thickness and modulus have a significant effect on strain transfer. Optimal strain transfer was achieved for an interface modulus of approximately 2 GPa. Strain transfer decreased consistently with increasing interface thickness. Debonding along the lateral edges of the gauge had little effect, while debonding proximal and distal to the sensing element decreased strain transfer. A waterproofing layer decreased strain transfer, and this effect was more pronounced as the modulus or thickness of the layer increased. Based on these simulations, specific recommendations were made to optimize strain transfer between bone and CPC coated gauges for experimental studies.


Assuntos
Materiais Biocompatíveis , Remodelação Óssea , Dispositivos de Fixação Ortopédica , Fosfatos de Cálcio , Cerâmica , Humanos