Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38852070

RESUMO

The exercise stress testing may unmask the type 1 Brugada pattern on the surface electrocardiogram in a portion of patients with Brugada syndrome. The occurrence of the type 1 Brugada pattern during an exercise test in pediatric patients is not common. Consequently, the diagnostic yield of the exercise test in this population is still to be explored. We present a case of exercise-induced type 1 Brugada pattern in a 12-year-old child with episodes of palpitations and discuss the available evidence on the role of the exercise stress test in the diagnosis and risk stratification of patients with Brugada syndrome.

2.
J Arrhythm ; 40(1): 150-153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333387

RESUMO

Conventional nonirrigated catheters cannot be able to create adequate lesions for effective slow pathway modulation in certain cases of pediatric atrioventricular nodal reentrant tachycardia ablation. Irrigated contact force sensing catheters may be considered in pediatric and adolescent patients to obtain a more extensive slow pathway modulation for redo ablation, avoiding dangerous radiofrequency applications close to the compact atrioventricular node or complex left-sided procedures.

3.
Pediatr Cardiol ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353710

RESUMO

The number of device implantation procedures has increased in adult patients with congenital heart disease (ACHD). Despite significant improvements in materials and implantation techniques, these patients are exposed to higher risk of device related complications than general population. Herein, we describe our single tertiary referral center experience on transvenous pacemaker (PM) implantation and follow-up in adult patients with moderate and complex congenital heart disease (CHD) as limited data are available on long-term outcome. We considered all adults with moderate and complex CHD aged more than 16 years who underwent transvenous single-chamber and dual-chamber PM implant for sinus node dysfunction or atrioventricular block between January 2013 to December 2022 at our Unit. Seventy-one ACHD patients were included in the study (mean age 38.6 ± 15.2 years, 64% with moderate CHD, 36% with complex CHD). Among 32 patients implanted with a dual chamber PM (DDD PM), 4 devices were reprogrammed in VDD mode, 3 in VVI and 2 in AAI mode during follow-up because of lead dysfunction or permanent atrial arrhythmia. In addition, 26 patients had a single chamber PM (AAI or VVI PM) and 13 patients had single-lead pacing system with a free-floating atrial electrode pair (VDD PM). Just one of 13 single-lead VDD PM was reprogrammed in VVI mode due to a low atrial sensing. In DDD PM group, 10 re-interventions were needed due to lead dysfunction (8 cases) and lead-related infective endocarditis (2 cases). Only 3 patients in the single-lead PM group developed lead dysfunction with 2 re-interventions needed, but no infective endocarditis was reported. The rate of long-term complications is high in moderate and complex ACHD with transvenous PM devices, and it is mainly lead-related. In our experience, the less leads implanted, the less complications will occur. Considering the heterogeneity of the ACHD population, transvenous single-chamber or dual-chamber PM device implantation should always be tailored on the single patient, balancing risks and benefits in this complex population.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38240394

RESUMO

Allergic reactions to components of cardiac implantable electronic devices are rare and often go undiagnosed, which can lead to a misdiagnosis of device infection. Contact allergy to subcutaneous implantable cardioverter defibrillator (S-ICD) is extremely rare. In this report, we present a case of cobalt-related contact allergy in a pediatric patient with Brugada syndrome who underwent S-ICD implantation.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37878161

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICD) are widely accepted therapy in congenital heart disease (CHD) patients at risk of life-threatening ventricular arrhythmias or sudden cardiac death (SCD) when pacing is not required. Occasionally, pacemaker (PM)-dependent CHD patients will subsequently develop an indication for a cardioverter defibrillator. The use of S-ICD in complex CHD patients who have had already PM devices implanted implies some specific considerations, as the safety for these patients in unknown and recommendations among physicians may vary widely. METHODS: We review the data and studied the indications for S-ICD in complex CHD with previous PM and discuss its usefulness in clinical practice. RESULTS: From a large cohort of 345 patients enrolled in the S-ICD Monaldi care registry, which encompass all the patients implanted in the Monaldi Hospital of Naples, we considered 11 consecutive complex CHD patients (10M/1F aged 40.4 ±18.4 years) who underwent S-ICD implant after a previous PM implant, from February 2015 to October 2022. Mean follow-up was 25.5 ± 22 months. All the patients showed a good compliance to the device system with no complications (infections or skin erosions). CONCLUSIONS: In complex CHD with already implanted PM devices, S-ICD implant appears to be a safe alternative to PM upgrading to transvenous ICD system, avoiding abandoned leads or life-threatening lead extraction. However, there are important issues with regard to testing and programming that need to be addressed at the time of implantation.

7.
Pediatr Cardiol ; 44(5): 1040-1049, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37093256

RESUMO

Atrioventricular reentrant tachycardia (AVRT) is the most common form of supraventricular tachycardia in newborns. AVRT is sometimes refractory to conventional antiarrhythmic therapy. We describe our experience about the use of the triple combination of flecainide + propranolol + amiodarone as third-line regimen for refractory and recurrent AVRT in newborns. We considered a series of 14 patients who had failed both first-line and second-line therapy and were treated using the combination of flecainide + propranolol + amiodarone. Transoesophageal electrophysiologic study (TES) was performed to test the effectiveness of medical therapy during hospitalization and to try to reduce the amount of therapy, after amiodarone wash-out, before 1 year of age. TES was repeated at 1 year of age to test the spontaneous resolution of the arrhythmia after treatment discontinuation. Rhythm control was achieved in all 14 patients. At a mean age of 9.3 ± 2 months, AVRT was not inducible by TES in 11/12 amiodarone-free patients. At a mean age of 14.1 ± 3 months, AVRT was still inducible in 7/12 patients after interrupting the entire antiarrhythmic therapy (58.3%). Triple combination was effective as third-line option to suppress AVRT refractory to single and double antiarrhythmic therapy, with no significant adverse events. Our experience suggests that triple therapy could be maintained for a short-term treatment, discontinuing amiodarone before 1 year of age to avoid long-term side effects. Newborns who needed triple therapy appear to have a lower chance of accessory pathway disappearance at 1 year of age. TES could be useful for risk stratification of recurrences at the time of drug discontinuation in infants considered to be at higher risk of recurrent AVRT.


Assuntos
Amiodarona , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Recém-Nascido , Lactente , Humanos , Flecainida/uso terapêutico , Propranolol/uso terapêutico , Antiarrítmicos/uso terapêutico , Taquicardia Supraventricular/tratamento farmacológico , Amiodarona/uso terapêutico
8.
Cardiol Young ; 33(12): 2574-2580, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37038838

RESUMO

BACKGROUND: Long-term data on COVID-19 vaccine safety, immunogenicity, and acceptance in adults with CHD are lacking. METHODS: This is a prospective study including adults with CHD patients undergoing COVID-19 vaccination from January 2021 to June 2022. Data on adverse events, antispike IgG titre, previous or subsequent COVID-19 infection, booster doses, and patients' attitude towards vaccination were collected. RESULTS: Four hundred and ninety CHD patients (36 ± 13 years, 53% male, 94% with moderate/complex defects) were prospectively included: 433 (88%) received a Pfizer-BioNTech mRNA vaccine, 31 (6%) Moderna mRNA vaccine, 23 (5%) AstraZeneca-Oxford ChAdOx1 nCov-19 vaccine, and 3 (0.6%) Janssen Vaccine; 310 (63%) received a booster dose. Median follow-up after vaccination was 1.53 [1.41-1.58] years. No major adverse event was reported. Eighty-two fully vaccinated patients contracted COVID-19 during follow-up after a median of 5.4 [4.3-6.5] months from the last dose. One patient with Ebstein's disease died from severe COVID-19. Symptoms' duration in patients who tested positive after vaccination was significantly shorter than in the group tested positive before vaccination (5.5 [3-8] versus 9 [2.2-15] days, p = 0.04). Median antispike IgG titre measured in 280 individuals (57%) at a median of 1.4 [0.7-3.3] months from the last dose was 2381 [901-8307] BAU/ml. Sixty patients (12%) also showed positive antinucleocapsid antibodies, demonstrating previous SARS-COV2 exposure. Twenty-nine percent appeared to have concerns regarding vaccine safety and 42% reported fearing potential effects of the vaccine on their cardiac disease before discussing with their CHD cardiologist. CONCLUSION: COVID-19 vaccines appear safe in the mid-term follow-up in adults with CHD with satisfactory immunogenicity and reduction of symptoms' duration in case of infection.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Adulto , Humanos , Masculino , Feminino , Vacinas contra COVID-19/efeitos adversos , Estudos Prospectivos , ChAdOx1 nCoV-19 , Seguimentos , RNA Viral , Vacinas de mRNA , COVID-19/epidemiologia , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinação , Imunoglobulina G
9.
Pediatr Cardiol ; 44(5): 1068-1075, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36576525

RESUMO

Implantable loop recorders (ILRs) are effective tools for detecting arrhythmias by long-term continuous heart rhythm monitoring. Benefits have been demonstrated even in pediatric patients. ILR with a long sensing vector has recently been designed to improve signal quality in terms of P wave visibility and R wave amplitude. However, there are no data on its use in pediatric patients. We considered a series of pediatric patients implanted with a long sensing vector ILR. Sensing performance, including R wave amplitude and P wave visibility, device-related complications, and diagnostic yield were collected. During follow-up, each patient guided by his/her parents/guardians was also asked to complete a brief questionnaire to assess patient acceptability of the device. Twenty-five consecutive pediatric patients (mean age 11.3 ± 3.5 years, 72% male) were enrolled. The insertion success rate was 100% on the first attempt with no complications. The median amplitude of the R wave was 1.15 mV (interquartile range, 1.01-1.42) with no significant differences between patients aged ≤ or > 10 years (p = 0.726) and between female and male (p = 0.483). P wave was classified as 'always visible' in 24/25 patients (96%). ILR was generally well accepted and tolerated by all involved patients. During a median follow-up of 297 days (117-317), we achieved in 5 patients a correlation between symptoms and rhythm disorders (20%) and ruled out significant arrhythmias in 6 symptomatic children (24%). Long sensing vector ILR showed to be well accepted, with good signal quality and an excellent safety profile even in pediatric patients.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Criança , Masculino , Feminino , Adolescente , Eletrodos Implantados/efeitos adversos , Arritmias Cardíacas/etiologia , Inquéritos e Questionários
10.
Monaldi Arch Chest Dis ; 93(1)2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35929642

RESUMO

Placement of traditional transvenous implantable cardioverter defibrillator (ICD) system in low-weight children is often difficult because of their vessel size, the elevated risk of lead malfunction and failure, children's growth and various anatomic constraints, creating the need for alternative solutions. Subcutaneous array leads combined with an abdominally placed ICD device can minimize the surgical approach. In this case series, we analyse the data behind indications for subcutaneous finger cardioverter defibrillator (SFCD) and discuss the preliminary clinical experience in low-weight children. We considered 4 consecutive children (mean age 3.9 years, range 3-5.5 years, mean body weight 17.6 Kg, range 14-23 Kg) who underwent SFCD implant from April 2016 to August 2020. All patients showed a good compliance to the device system with no complications (infections or skin erosions). No patients experienced in the observation period (mean time 44.5±21.5 months) sustained ventricular arrhythmias requiring shocks. No inappropriate shocks released by the device occurred. No significant changes were observed in LET (lowest energy tested) performed around 24 months of follow-up. All patients showed a good compliance and stable atrio-ventricular sensing and pacing thresholds. In smaller children in whom a transvenous approach is not feasible or not possible for anatomic reasons, the SFCD appears to be a safe method to prevent SCD with little surgical trauma and preservation of an intact vascular system, providing an adequate bridge to transvenous ICD or subcutaneous ICD implant late in the life.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Humanos , Criança , Pré-Escolar , Cardioversão Elétrica/efeitos adversos , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Fatores de Tempo , Resultado do Tratamento , Morte Súbita Cardíaca/prevenção & controle
11.
Indian Pacing Electrophysiol J ; 22(5): 217-222, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35777690

RESUMO

BACKGROUND: Wearable cardioverter-defibrillators (WCDs) are currently used in patients at temporarily heightened risk for sudden cardiac death (SCD) who are temporarily unable to receive an implantable cardioverter-defibrillator (ICD). WCD can safely record and terminate life-threatening arrhythmias through a non-invasive electrode-based system. The current clinical indications for WCD use are varied and keep evolving as experience with this technology increases. METHODS: We reviewed and explored the data behind indications for WCD use and discuss its usefulness in congenital heart disease (CHD) patients. RESULTS: We considered 8 consecutive patients (mean age 35.25 years, range 18-51 years, average duration of WCD use 4 months, range 3-6 months) with complex CHD, in which a WCD was used between June 2018 and January 2022. No sustained ventricular arrhythmias requiring shocks were recorded in the observation period. No inappropriate shocks were recorded. All the patients showed a good compliance and a very high mean wear time per day (21.2 ± 1 h a day). Four patients implanted a permanent device (3 CRT-D, 1 ICD), three underwent cardiac surgery at the end of the WCD period and one is still on the waiting list for the operation. CONCLUSIONS: Larger trial could confirm the possible conceivable benefit from an extended use of the WCD in certain populations with complex CHD as in our case series, especially in patients with life-treating ventricular arrhythmias waiting for surgery for residual cardiac defects or in the early phases following the surgical/hemodynamic interventions, patients with tachycardiomyopathy expected to improve after the arrhythmias are removed and patients awaiting implantation of an ICD at high risk due to active infection.

12.
J Interv Card Electrophysiol ; 63(2): 283-293, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33709295

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICD) are widely accepted therapy in children and adolescents who are survivors of cardiac arrest or for high-risk patients with inheritable channelopathies, cardiomyopathies, or congenital heart disease. Initial experience with subcutaneous ICD (S-ICD) systems has shown a high efficacy in adults. However, the use of S-ICD in children and adolescents implies some specific considerations, as the safety for these patients is unknown and recommendations among physicians may vary widely. METHODS: We reviewed the data and studied the indications for S-ICD in children and adolescents and discuss the preliminary clinical experience. RESULTS: From a cohort of 297 patients enrolled in the S-ICD "Monaldi care" registry that encompass all the patients implanted in the Monaldi Hospital of Naples, we considered 21 consecutive children and adolescents (mean age 13.9 years, range 8-18 years, mean body weight 59.3 kg, range 38-100 kg) who underwent S-ICD implant from April 2014 to June 2020. Mean follow-up was 41.9±21.9 months. Only one patient presented, 6 weeks after implantation, skin erosion at the inferior parasternal incision that resolved after antibiotic therapy, without the necessity of any system revision. Two patients experienced appropriate shocks and four inappropriate shocks, due to T wave oversensing or atrial arrhythmia. Only one patient, with arrhythmogenic right ventricular dysplasia, required a system revision after 36 months of the first implantation and then a reintervention with a replacement of the S-ICD by a conventional ICD system. CONCLUSIONS: Our experience suggests that the S-ICD device can be used in some children over the age of 8 as well as adults, with a similar rate of unwanted side effects, and early evidence of apparent efficacy.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Adolescente , Adulto , Arritmias Cardíacas/terapia , Criança , Morte Súbita Cardíaca/prevenção & controle , Humanos , Sistema de Registros , Resultado do Tratamento
13.
Am J Cardiol ; 166: 107-113, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34930612

RESUMO

Adults with congenital heart disease (ACHD) are frequently affected by thyroid diseases (TDs). However, the clinical relevance of TD in ACHD remains unknown. We aimed to describe the prevalence of TD in the ACHD population and to ascertain whether TD are associated with worse outcome. Patients with ACHD >18 years attending our tertiary center for a day-case between 2014 and 2019 were included. Clinical data between patients' first visit and December 2020 were collected. Primary end point was a combination of death, hospitalization for heart failure (HF), and new-onset of arrhythmic events. Secondary end points were each part of the primary outcome as separate end points. A total of 495 patients with ACHD (32.2 [24.5 to 45.6] years; 54% women) were included. Median follow-up was 9.4 (4.5 to 13.1) years. The prevalence of TD was 30%. TD group showed worse clinical status, as demonstrated by N-terminal pro b-type natriuretic peptide values (243.5 [96.5 to 523] vs 94 [45 to 207] pg/ml, p <0.001) and New York Heart Association class (27% vs 13% in class III to IV, p <0.0001) with higher incident rate of adverse events at follow-up (4.45 [3.43 to 5.69] % vs 1.29[0.94 to 1.75] % per person-year, p <0.001). TD were independently associated with higher risk of death (hazard ratio [HR] 4.1, p = 0.009), arrhythmic events (HR 3.8, p <0.0001), and hospitalization for HF (HR 8.02, p <0.0001). There was a fourfold increased risk of primary end point in the TD group even after propensity score matching for clinical variables including age, gender, disease complexity, physiological stage, previous palliative surgery, ventricular function, pulmonary arterial hypertension, cyanosis, and presence of systemic right ventricle (HR 4.47, p <0.0001). In conclusion, TD are predictive of adverse outcome in the ACHD population. Routine screening of thyroid function during follow-up in this population may be helpful to identify those with higher risk of death, arrhythmias, and HF.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Doenças da Glândula Tireoide , Adulto , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/epidemiologia , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Prognóstico , Doenças da Glândula Tireoide/complicações , Doenças da Glândula Tireoide/epidemiologia
14.
JACC Case Rep ; 3(5): 736-739, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34317616

RESUMO

Obstruction of the superior vena cava represents an under-recognized cause of chylothorax in the adult population. Our case report describes the successful conservative management of chylothorax due to bilateral superior vena cava obstruction in an adult patient with complex congenital heart disease. (Level of Difficulty: Beginner.).

15.
J Electrocardiol ; 66: 16-17, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33690022

RESUMO

A 3-months-old infant was urgently admitted for drowsiness and lack of appetite started 24 h before. The ECG showed sinus rhythm with a prolonged AV interval (200 ms) and very large QRS complexes (280 ms) due to Flecainide overdosing following incorrectly administration for poor communication between parents resulted in both giving a dose to the infant. Flecainide serum level was 1.2µg/ml, confirming the diagnosis of an accidental drug intoxication. The patient started continue hydration with a close monitoring. Three hours later a significant narrowing of the QRS complex (150 ms) was observed, then over the following 24 h, the QRS almost completely normalized.


Assuntos
Antiarrítmicos , Overdose de Drogas , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Flecainida , Humanos , Lactente
16.
Pacing Clin Electrophysiol ; 44(5): 952-954, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33283282

RESUMO

This case report describes a procedure of retrieval of a leadless transcatheter pacemaker from the right pulmonary artery 3 days after device implantation. An 80-year-old man affected by ischemic cardiomyopathy and sinus node dysfunction was implanted with a leadless transcatheter pacemaker in the low septum of the right ventricle. Three days after the procedure, the leadless pacemaker migrated into a side branch of the right pulmonary artery. The device was successfully removed using two snares hooked to a tine via the proximal retrieval feature.


Assuntos
Fibrilação Atrial/terapia , Remoção de Dispositivo , Marca-Passo Artificial , Artéria Pulmonar , Síndrome do Nó Sinusal/terapia , Idoso de 80 Anos ou mais , Angiografia , Humanos , Masculino
18.
Int J Cardiol Congenit Heart Dis ; 6: 100266, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35360668

RESUMO

Background: real-world data on COVID-19 vaccine safety, immunogenicity and acceptance in adults with congenital heart disease (ACHD) are lacking. Methods: ACHD patients who were offered COVID-19 vaccination from January to June 2021 were included. Data on adverse events, on patients' attitude towards vaccination and antispike IgG titre were retrospectively collected. A group of healthy individuals with similar age and sex undergoing vaccination was included for comparison. Results: 208 patients followed in a single ACHD tertiary centre (33.3 [26-45] years, 54% male) received COVID-19 vaccine, 65% vaccinated at our institution: 199 (96%) received Pfizer-BioNTech BNT162b2 vaccine, 4 (2%) Moderna-1273 and 5 (2%) AstraZeneca-ChAdOx1. Median follow-up after vaccination was 79 [57-96] days. No major adverse event was reported and the incidence of minor events was not different between ACHD patients and the control group. One patient was diagnosed with acute pericarditis. There were two deaths unrelated to the vaccine during follow-up. Three (1.5%) vaccinated patients tested positive for COVID-19. Antispike IgG titre, available in 159 (76%) patients, was 1334 [600-3401] BAU/ml, not significantly different from the control group (p=0.2). One patient with Fontan failure was seronegative. Advanced physiological stage was associated with lower antibody response, independently from previous viral exposure (p<0.0001). Fourteen percent refused COVID-19 vaccination at our institution. However, 50% of vaccinated patients declared to have been influenced by the discussion with the ACHD cardiologist and 66% of those vaccinated in situ reported that undergoing COVID-19 vaccination at the ACHD centre made them feel safer. Conclusion: COVID-19 vaccines appear safe in ACHD with satisfactory immunogenicity. However, the most vulnerable patients showed lower antibody response. ACHD team may play a key role in vaccine acceptance.

19.
Eur Heart J Case Rep ; 4(5): 1-7, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33204982

RESUMO

BACKGROUND: Pulmonary valve (PV) endocarditis is a frequent complication during follow-up in patients with repaired right ventricular outflow tract (RVOT) obstruction and poses relevant diagnostic and treatment challenges. We aimed to describe in details the possible different clinical presentations of this rare condition and to highlight the role of both transthoracic and transoesophageal echocardiography which, in experienced hands, may provide comprehensive useful information for the clinicians. CASE SUMMARY: We below describe the clinical presentation and the echo findings of three cases of pulmonary valve endocarditis complicating disease course after different repair modalities of congenital right ventricular outflow tract obstruction. DISCUSSION: The present case series outlines the diagnostic challenges of this increasingly frequent complication during follow-up of patients with congenital RVOT dysfunction after both surgical and percutaneous repair. Despite the diffusion of multimodality imaging, echocardiography with PV-dedicated views play a pivotal role in diagnosing such condition and guiding clinical management. Furthermore, this case series highlight that the suspicion of infective endocarditis should be raised whenever a sudden increase in transvalvular gradient is found during follow-up.

20.
J Electrocardiol ; 62: 145-147, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32882527

RESUMO

We report the case of a patient with recurrent episodes of postoperative intra-atrial reentrant tachycardia occurring after surgical patch closure of a sinus venosus atrial septal defect (SVASD). Arrhythmic episodes, as usually reported in scar-related arrhythmias, were resistant to antiarrhythmic therapy and worsened patient's quality of life. Therefore, we decided to perform an intracardiac electrophysiology study using a 3D-high definition mapping system to identify and treat the precise arrhythmic substrate with radiofrequency ablation. There is a growing evidence that this technique represents a valid therapeutic option in postoperative arrhythmias refractory to medical treatment in patients with repaired congenital heart disease.


Assuntos
Ablação por Cateter , Preparações Farmacêuticas , Taquicardia Supraventricular , Eletrocardiografia , Humanos , Qualidade de Vida , Taquicardia Supraventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA