Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38914901

RESUMO

BACKGROUND: While ethanol infusion into the vein of Marshall (VOM) as an adjunct to atrial fibrillation ablation has shown promise, adoption has been limited by the technical expertise required, unclear antiarrhythmic mechanism, and complication risk. Delayed pericardial effusions have been associated with ethanol infusion into the VOM in prior studies. Very little is known about how the procedural approach itself can impact the risk of delayed effusions. We sought to understand the incidence and influence of procedural technique on complications including delayed pericardial effusions from VOM ethanol infusion at a large single medical center. METHODS: A total of 275 atrial ablation cases wherein VOM ethanol infusion was attempted were identified from the time of the program's inception in 2019 at Maine Medical Center (Portland, ME) until October of 2023. Cases were classified into phase I cases (early experience) and phase II cases (later experience) based upon temporal programmatic changes in the ethanol dose and infusion rate as well as the use of routine VOM venography. Procedural details and complications were adjudicated from the medical record. RESULTS: The overall VOM ethanol infusion success was 91.4%. Nine complications (3.3%) occurred in eight patients (2.9% of patients). These were more frequent in phase I (5.8%) compared to phase II (1.3%, p = 0.047). This difference was driven by a difference in delayed presentations of tamponade, which occurred in four patients in phase I (3.3%) and in no patients in phase II (0%, p = 0.037). Twelve-month estimated atrial arrhythmia freedom did not differ between groups (73.8% phase I vs 70.4% phase II, p = 0.24). CONCLUSION: In our single-center experience, adjustments to the procedural approach with lower ethanol infusion rate and dosage, combined with utilizing selective VOM venography, associated with a lowering of complication rates and in particular, delayed pericardial tamponade.

2.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737773

RESUMO

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Retrospectivos , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Ablação por Cateter/métodos
4.
J Am Coll Cardiol ; 47(1): 98-107, 2006 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-16386671

RESUMO

UNLABELLED: In the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II, implantable cardioverter-defibrillator (ICD)-randomized patients underwent electrophysiologic testing. Both inducible and noninducible patients received an ICD. We correlated inducibility with the occurrence of subsequent ventricular tachycardia (VT) or ventricular fibrillation (VF). Intracardiac ICD electrograms for subsequent events were analyzed to categorize the spontaneous arrhythmia as VT or VF. The two-year Kaplan-Meier event rate for VT in inducible patients was 29.0% versus 19.3% in noninducible patients. However, ICD therapy for spontaneous VF was less common at two years in inducible patients (3.2%) than in noninducible patients (8.6%). In the MADIT II study, inducibility predicted an increased likelihood of VT but decreased VF. OBJECTIVES: We correlated electrophysiologic inducibility with spontaneous ventricular tachycardia (VT) or ventricular fibrillation (VF) in the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II. BACKGROUND: In the MADIT II study, 593 (82%) of 720 implantable cardioverter-defibrillator (ICD) randomized patients underwent electrophysiologic testing. Patients received an ICD whether they were inducible or not. METHODS: A "standard" inducibility definition included sustained monomorphic or polymorphic VT induced with three or fewer extrastimuli or VF induced with two or fewer extrastimuli. We compared a narrow inducibility definition (only monomorphic VT) and a broad definition (standard definition plus VF with three extrastimuli). We used ICD-stored electrograms to categorize spontaneous VT or VF. RESULTS: Inducible patients (standard definition) had a greater likelihood of experiencing ICD therapy for VT than noninducible patients (p = 0.023). Unexpectedly, ICD therapy for spontaneous VF was less common (p = 0.021) in inducible patients than in noninducible patients. The two-year Kaplan-Meier event rate for VT or VF was 29.4% for inducible patients and 25.5% for noninducible patients. Standard inducibility did not predict the combined end point of VT or VF (p = 0.280, by log-rank analysis). The narrow inducibility definition outperformed the standard definition, whereas the broad definition appeared inferior to the standard definition. CONCLUSIONS: In the MADIT II study patients, inducibility was associated with an increased likelihood of VT. Noninducible MADIT II study subjects using this electrophysiologic protocol had a considerable VT event rate and a higher VF event rate than inducible patients. Induction of polymorphic VT or VF, even with double extrastimuli, appears less relevant than induction of monomorphic VT.


Assuntos
Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA