Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiol Cases ; 25(1): 26-29, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35024064

RESUMO

Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle is a rare but well-recognized complication of device implantation. We report a case of an unicameral ICD lead inadvertently placed through the left subclavian artery right positioned, across the aortic valve into the left ventricle, in a patient with situs viscerum inversus. A transthoracic echocardiogram about a month after the procedure showed an unusual course of the lead. The lead was successfully removed without complications or sequelae. .

2.
J Med Imaging Radiat Oncol ; 66(7): 940-945, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34854240

RESUMO

INTRODUCTION: The objective of this study was to compare the frequency and entity, in computed tomography (CT) urography, of streak artefacts on the urinary tract generated by two contrast agents with a different iodine concentration and osmolarity. METHODS: Computed tomography scans including an excretory renal phase, performed on adult subjects in the period May-July 2020, were retrospectively evaluated in consensus by three expert radiologists, to detect any streak artefacts located in the urinary tract. Patients were administered either 1.6 mL/kg of Iodixanol 320 mgI/mL or 1.3 mL/kg of Iomeprol 400 mgI/mL. RESULTS: In total, 144 CT scans were analysed, subdivided into two groups administered either Iodixanol (71/144 (49.3%) patients) or Iomeprol (73/144 (50.7%) patients). In 41% cases, no beam hardening artefacts were found; among these, 12/59 (20.3%) patients had received Iodixanol and 47/59 (79.7%) Iomeprol. In the Iodixanol group, the mean contrast density on the renal pelvis was 2565.6 HU and streak artefacts occurred in 59/71 cases (83.1%); in 33/59 (55.9%) cases, the artefacts were marked, and in 26/59 (44.1%) minimal. In the Iomeprol group, the mean contrast density on the renal pelvis was 1666 HU and streak artefacts occurred in 26/73 cases (35.6%); in 7/26 (27%) cases, the artefacts were marked and in 19/26 (73%) minimal. CONCLUSION: The study data demonstrate a significant difference in the attenuation values of iodine urine in the excretory system between the Iodixanol and Iomeprol group. Iodixanol induced a higher frequency and burden of artefacts, compared to Iomeprol.


Assuntos
Meios de Contraste , Iodo , Adulto , Artefatos , Humanos , Iopamidol/análogos & derivados , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos , Urografia
3.
Microorganisms ; 9(10)2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34683358

RESUMO

Our daily experience in a COVID hospital has allowed us to learn about this disease in many of its changing and unusual aspects. Some of these uncommon manifestations, however, appeared more frequently than others, giving shape to a multifaceted COVID-19 disease. This pictorial review has the aim to describe the radiological aspects of atypical presentations and of some complications of COVID-19 disease in adults and children and provide a simple guide for radiologists to become familiar with the multiform aspects of this disease.

4.
Homo ; 72(1): 53-60, 2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33620370

RESUMO

The estimation of age and sex is mandatory in forensic identification of unknown skeletal remains and it could be reached analyzing different bones' features. The morphometric evaluation of Sella turcica is less described in literature. Many studies have been published in this field for age estimation but none of them based on head CT scan measurement. Previous studies were carried out for age estimation on different populations, but any study has been carried out on the Italian population. Furthermore, no studies were carried out with CT scan technology for the correlation between sex and Sella turcica. Thanks to CT scan technology it has been possible to measure sella turcica's dimensions in an easier way than previous methods, to detect more accurate parameters and even introduce a new one. In this study, the sample was composed of 115 adults, 53 males, and 62 females. Five different measurements of the sellae turcicae were taken. The purpose of this study was to find new elements for sex assessment with the evaluation of sella turcica measurements, improving previous studies, analyzing an Italian European sample. In this study, results of the statistical analysis showed correlation between sex and sella turcica's parameter "Length of Sella Turcica" for which grater values are related to male gender. In conclusion, the Authors consider this unexpected result useful for sex determination in association with other parameters.


Assuntos
Medicina Legal , Sela Túrcica , Adulto , Restos Mortais , Cefalometria , Feminino , Humanos , Masculino , Sela Túrcica/anatomia & histologia , Sela Túrcica/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA