2.
J Clin Monit Comput ; 33(2): 211-222, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30847738

RESUMO

Hemodynamic management is a mainstay of patient care in the operating room and intensive care unit (ICU). In order to optimize patient treatment, researchers investigate monitoring technologies, cardiovascular (patho-) physiology, and hemodynamic treatment strategies. The Journal of Clinical Monitoring and Computing (JCMC) is a well-established and recognized platform for publishing research in this field. In this review, we highlight recent advancements and summarize selected papers published in the JCMC in 2018 related to hemodynamic monitoring and management.


Assuntos
Monitorização Hemodinâmica/métodos , Hemodinâmica/fisiologia , Monitorização Fisiológica/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Determinação da Pressão Arterial , Débito Cardíaco , Sistema Cardiovascular , Humanos , Hipotensão , Unidades de Terapia Intensiva , Período Intraoperatório , Salas Cirúrgicas , Publicações Periódicas como Assunto , Período Perioperatório
3.
J Clin Monit Comput ; 32(2): 189-196, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29484529

RESUMO

Hemodynamic monitoring provides the basis for the optimization of cardiovascular dynamics in intensive care medicine and anesthesiology. The Journal of Clinical Monitoring and Computing (JCMC) is an ideal platform to publish research related to hemodynamic monitoring technologies, cardiovascular (patho)physiology, and hemodynamic treatment strategies. In this review, we discuss selected papers published on cardiovascular and hemodynamic monitoring in the JCMC in 2017.


Assuntos
Técnicas de Diagnóstico Cardiovascular/instrumentação , Técnicas de Diagnóstico Cardiovascular/tendências , Ecocardiografia/tendências , Técnicas de Diluição do Indicador/tendências , Monitorização Fisiológica/tendências , Publicações Periódicas como Assunto/tendências , Animais , Determinação da Pressão Arterial , Sistema Cardiovascular , Ecocardiografia/instrumentação , Hemodinâmica , Humanos , Técnicas de Diluição do Indicador/instrumentação , Monitorização Fisiológica/instrumentação , Volume Sistólico
4.
J Clin Monit Comput ; 30(5): 519-26, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26873749

RESUMO

To compare the performance of a bioreactance cardiac output (CO) monitor (NICOM) and transcutaneous Doppler (USCOM) during head up tilting (HUT). Healthy young adult subjects, age 22 ± 1 years, 7 male and 7 female, were tilted over 3-5 s from supine to 70° HUT, 30° HUT and back to supine. Positions were held for 3 min. Simultaneous readings of NICOM and USCOM were performed 30 s into each new position. Mean blood pressure (MBP), heart rate (HR), CO and stroke volume (SV), and thoracic fluid content (TFC) were recorded. Bland-Altman, percentage changes and analysis of variance for repeated measures were used for statistical analysis. Pre-tilt NICOM CO and SV readings (6.1 ± 1.0 L/min and 113 ± 25 ml) were higher than those from USCOM (4.1 ± 0.6 L/min and 77 ± 9 ml) (P < 0.001). Bland-Altman limits of agreement for CO were wide with a percentage error of 38 %. HUT increased MBP and HR (P < 0.001). CO and SV readings decreased with HUT. However, the percentage changes in USCOM and NICOM readings did not concur (P < 0.001). Whereas USCOM provided gravitational effect proportional changes in SV readings of 23 ± 15 % (30° half tilt) and 44 ± 11 % (70° near full tilt), NICOM changes did not being 28 ± 10 and 33 ± 11 %. TFC decreased linearly with HUT. The NICOM does not provide linear changes in SV as predicted by physiology when patients are tilted. Furthermore there is a lack of agreement with USCOM measurements at baseline and during tilting.


Assuntos
Débito Cardíaco/fisiologia , Ecocardiografia Doppler/métodos , Posicionamento do Paciente , Volume Sistólico/fisiologia , Termodiluição/métodos , Cateterismo , Feminino , Voluntários Saudáveis , Frequência Cardíaca/fisiologia , Hemodinâmica , Humanos , Modelos Lineares , Masculino , Monitorização Fisiológica , Artéria Pulmonar/patologia , Adulto Jovem
6.
J Clin Monit Comput ; 30(5): 559-67, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26315476

RESUMO

The demise of the pulmonary artery catheter as a gold standard in cardiac output measurement has created the need for new standard. Doppler cardiac output can be measured suprasternally (USCOM) and via the oesophagus (CardioQ). Use in tandem they may provide a reliable trend line of cardiac output changes against which new technologies can be assessed. Data from three similar clinical studies was pooled. Simultaneous USCOM and CardioQ readings, 13 (7-27), were performed every 15-30 min intraoperatively. Within individual patient regression analysis was performed. Data was normalized, CardioQ against USCOM, to eliminate the systematic error component following calibration. Bland-Altman and trend, concordance and polar analysis, were performed on the grouped data. Cardiac output was indexed (CI) to BSA. Data from 53 patients, aged 59 (26-81) years, scheduled for major surgery were included. Within-individual mean (SD) CI was 3.4 (0.6) L min(-1) m(-2). Correlation was good to excellent in 83 % of cases, R(2) > 0.80, and reasonable in 96 %, R(2) > 0.60. Percentage error was 38 %, and decreased to 14 % with normalization. The estimated 95 % precision for a single Doppler reading was ±10 %. Concordance rate was 96.6 % (confidence intervals 94.7-99.5 %) and above the >92 % threshold for good trending ability. Polar analysis also confirmed good trending ability. The regression line between Doppler methods was offset with a slope of 0.9, thus CardioQ CI readings increased relative to USCOM. Both Doppler methods trended cardiac output reliably. Used in tandem they provide a new standard to assess cardiac output trending.


Assuntos
Débito Cardíaco , Ecocardiografia Doppler/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Calibragem , Esôfago/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Análise de Regressão , Reprodutibilidade dos Testes , Projetos de Pesquisa , Processamento de Sinais Assistido por Computador , Procedimentos Cirúrgicos Operatórios , Estudos de Validação como Assunto
7.
Anesth Analg ; 121(4): 936-945, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26218863

RESUMO

BACKGROUND: Minimally invasive continuous cardiac output measurements are recommended for use during anesthesia to guide fluid therapy, but such measurements must trend changes reliably. The NICOM Cheetah, a BioReactance monitor, is being recommended for intraoperative use. To validate its use, Doppler methods, suprasternal USCOM and esophageal CardioQ, were used in tandem to provide reliable estimates of changing trends in cardiac output. Preliminary comparisons showed that upper abdominal surgical interventions caused shifts in the calibration of the NICOM. The purpose of this study was to confirm and measure these calibration shifts. METHODS: Major surgery patients, aged 58 (32-78) years, 12 males and 15 females, were divided into 4 study groups: (a) controls-lower abdominal or peripheral surgery (n = 9); (b) laparoscopy with abdominal insufflation (n = 6); (c) open upper abdominal surgery with large multiblade retractor placement (n = 6) and (d) head-down robotic surgery (n = 6). Simultaneous NICOM and Doppler readings were taken every 15 to 30 minutes. Within-individual time plots were drawn, and regression analysis between NICOM-USCOM and CardioQ-USCOM readings was performed. Bland-Altman and trend (concordance) analyses were also performed. RESULTS: Three hundred ninety NICOM comparisons were collected. Duration of surgeries was 4 (1½ to 11) hours, with 7 to 22 sets of readings per case. Mean (SD) cardiac index from USCOM readings was 3.5(1.0) L/min/m. Individual time plots showed shifts in NICOM calibration relative to Doppler (USCOM) in cardiac index of ±0.9 (0.6-1.4) L/min/m during the surgical interventions. In 13 of 18 patients (72%), the shift was downward, but upward shifts did occur. Within-individual correlations between CardioQ-USCOM showed good trending R = 0.87 (range, 0.60-0.97). In the control group, NICOM-USCOM also showed good trending R = 0.89 (0.69-0.97). However, trending was poor in the intervention groups, R = 0.43 (0.03-0.71; P < 0.0001). The Bland-Altman percentage error between NICOM-USCOM (57 [54-60]%) was greater than that between CardioQ-USCOM (42 [40-44]%) (P < 0.0001). Concordance rates were 82 (77-88)% from 101 data pairs and 95 (90-99)% from 72 data pairs, respectively. CONCLUSIONS: Doppler monitoring used in tandem provided valid trend lines of cardiac output changes against which NICOM readings could be compared. Intraoperatively, the NICOM was shown to track changes in cardiac output reliably in most circumstances. However, surgical interventions to the upper abdomen caused shifts in readings by >1 L/min/m, and the direction of the shifts was unpredictable. Anesthesiologists need to be aware of these calibration shifts and anticipate their occurrence, whenever the NICOM is used intraoperatively.


Assuntos
Débito Cardíaco/fisiologia , Ecocardiografia Doppler/normas , Esôfago , Laparoscopia/normas , Monitorização Intraoperatória/normas , Esterno , Adulto , Idoso , Calibragem/normas , Cardiografia de Impedância/métodos , Cardiografia de Impedância/normas , Ecocardiografia Doppler/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Robótica/normas
8.
Teach Learn Med ; 27(3): 307-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26158333

RESUMO

PROBLEM: The availability of less expensive and smaller ultrasound machines has enabled the use of ultrasound in virtually all major medical/surgical disciplines. Some medical schools have incorporated point-of-care ultrasound training into their undergraduate curriculum, whereas many postgraduate programs have made ultrasound training a standard. The Chinese University of Hong Kong has charged its Department of Anaesthesia and Intensive Care to spearhead the introduction of ultrasound into the final-year medical curriculum by introducing handheld transthoracic echocardiography as part of perioperative assessment. INTERVENTION: All 133 final-year students completed a 2-week anesthesia rotation, which began with a half-day session consisting of a lecture and hands-on practice session during which they learned 9 basic transthoracic echocardiography views using 4 basic ultrasound probe positions. CONTEXT: Each student was required to perform a transthoracic echocardiography-examine under supervision of 1 patient/week for 2 weeks, and their results were compared against that of the supervisor's. Most patients were elective cardiac surgery patients. One long question on transthoracic echocardiography was included in their end-of-year surgery examination paper. Students provided feedback on their experience. OUTCOME: Most students learned the basic transthoracic echocardiography views fairly efficiently and had variable, though generally favorable, success rates in identifying obvious cardiac anomalies, including use of color Doppler. A few common mistakes were identified but were easily correctable. Logistics for mobilizing enough bedside supervision were challenging. Students reported positive feedback on the teaching initiative. LESSONS LEARNED: We were able to execute a successful short training course on transthoracic echocardiography during the final-year medical degree anesthesia rotation. Our initiative may set an example for other clinical departments to design similar courses pertinent to their specialties and syllabuses.


Assuntos
Anestesiologia/educação , Ecocardiografia/instrumentação , Educação de Graduação em Medicina/métodos , Estudantes de Medicina , Competência Clínica , Currículo , Humanos
10.
Adv Health Sci Educ Theory Pract ; 20(4): 885-901, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25413583

RESUMO

Virtual patients are computerised representations of realistic clinical cases. They were developed to teach clinical reasoning skills through delivery of multiple standardized patient cases. The anesthesia course at The Chinese University of Hong Kong developed two novel types of virtual patients, formative assessment cases studies and storyline, to teach its final year medical students on a 2 week rotational course. Acute pain management cases were used to test if these two types of virtual patient could enhance student learning. A 2 × 2 cross over study was performed in academic year 2010-2011 on 130 students divided into four groups of 32-34. Performance was evaluated by acute pain management items set within three examinations; an end of module 60-item multiple choice paper, a short answer modified essay paper and the end of year final surgery modified essay paper. The pain management case studies were found to enhanced student performance in all three examinations, whilst the storyline virtual patient had no demonstrable effect. Student-teaching evaluation questionnaires showed that the case studies were favored more than the storyline virtual patient. Login times showed that students on average logged onto the case studies for 6 h, whereas only half the students logged on and used the storyline virtual patient. Formative assessment case studies were well liked by the students and reinforced learning of clinical algorithms through repetition and feedback, whereas the educational role of the more narrative and less interactive storyline virtual patient was less clear .


Assuntos
Anestesiologia/educação , Simulação por Computador , Educação de Graduação em Medicina/métodos , Manejo da Dor/normas , Adulto , Idoso , Currículo , Avaliação Educacional , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade
11.
Ann Surg ; 261(2): 297-303, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24509208

RESUMO

OBJECTIVE: To evaluate the risks of perioperative respiratory complications and postoperative morbidity associated with active and passive cigarette smoking. BACKGROUND: Environmental tobacco smoke is associated with perioperative respiratory events in children, but its effect in adults is unknown. METHODS: We conducted a cohort study of 736 adult patients receiving general anesthesia for major elective surgery. Patients were classified according to their self-reported smoking history and urinary cotinine concentration within 48 hours before surgery. The main outcomes were composite measures of perioperative respiratory complications and postoperative morbidity on the third day after surgery. RESULTS: There were 313 (42.5%) never-smokers (reference group), 92 (12.5%) passive nonsmokers, 157 (21.3%) ex-smokers without environmental tobacco smoke exposure, 53 (7.2%) passive ex-smokers, and 121 (16.4%) smokers. The incidence of perioperative respiratory complications and postoperative morbidity was 9.5% [95% confidence interval (CI), 7.5-11.8] and 29.2% (95% CI, 26.0-32.6), respectively. Smoking was significantly associated with an increased risk of perioperative respiratory complications [relative risk (RR), 4.40; 95% CI, 2.20-8.80] and postoperative morbidity (RR, 1.86; 95% CI, 1.22-2.83). Although passive smoking was not associated with the risk of perioperative respiratory complications, the risk of postoperative morbidity was increased in passive nonsmokers (RR, 1.51; 95% CI, 1.04-2.21) and passive ex-smokers (RR, 2.21; 95% CI, 1.39-3.50). CONCLUSIONS: One in 5 adults was exposed to environmental tobacco smoke before surgery. Passive cigarette smoking showed very little, if any, increased risk of perioperative respiratory complications. Both active exposure and passive exposure to cigarette smoke increased the risk of postoperative morbidity.


Assuntos
Complicações Pós-Operatórias/etiologia , Doenças Respiratórias/etiologia , Fumar/efeitos adversos , Poluição por Fumaça de Tabaco/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Doenças Respiratórias/epidemiologia , Fatores de Risco , Autorrelato , Adulto Jovem
12.
J Clin Monit Comput ; 28(1): 83-93, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23907210

RESUMO

Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to the Circulation" we use the example of an elderly man undergoing major urological robotic surgery to highlight the utility and limitations of intra-operative USCOM use. USCOM readings were verified against oesophageal Doppler. Despite the lack of major blood loss (<500 ml in 8-h), significant changes in haemodynamics were recorded. CO ranged from 3.2 to 8.3 l/min. The quality of USCOM scans and reliability of data was initially poor, but improved as CO increased as surgery progressed. When USCOM scans became acceptable the correlation with oesophageal Doppler was R(2) = 8.0 (p < 0.001). Several characteristic features of the supra-sternal Doppler scans were identified: Aortic and pulmonary flow waves, valve closure, E and A waves, false A-wave and aberrant arterial flow patterns. Their identification helped with identifying the main flow signal across the aortic valve. The USCOM has the potential to monitor changes in CO and related flow parameters intra-operatively and thus help the anaesthetist to more fully understand the patient's haemodynamics. However, achieving a good quality scan is important as it improves the reliability of USCOM data. The supra-sternal route is rich in flow signals and identifying the aortic valve signal is paramount. Recognizing the other characteristic waveforms in the signal helps greatly.


Assuntos
Anestesia/métodos , Cistectomia/métodos , Ecocardiografia Doppler/métodos , Monitorização Intraoperatória/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Urológicos/métodos , Idoso de 80 Anos ou mais , Débito Cardíaco , Desenho de Equipamento , Esôfago/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Monitorização Fisiológica , Robótica , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/cirurgia
13.
J Cardiothorac Vasc Anesth ; 27(6): 1122-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24011911

RESUMO

OBJECTIVE: To evaluate the ability of the third-generation (3.01) of FloTrac/Vigileo monitor (Edwards Lifesciences, Irvine, CA) to follow variations in cardiac output (∆CO) using the new polar plot approach. DESIGN: Prospective interventional study. SETTING: Single hospital university study. PARTICIPANTS: Twenty-five patients referred for cardiac surgery. INTERVENTIONS: CO was measured simultaneously by 3 to 5 bolus thermodilution (COtd measurements), using a pulmonary artery catheter and by arterial pulse contour analysis, using the FloTrac/Vigileo (COvi). Data were collected at eight time points: before incision, after sternotomy, before and after protamine sulfate infusion, at the start of sternal closure, at the end of surgery, on arrival to intensive care unit, and after a standardized volume expansion with 500 mL of hetastarch 6%. MEASUREMENTS AND MAIN RESULTS: One-hundred thirty-five pairs of CO data were collected; the mean bias of all CO measurements corrected for repeated measures was 0.2 L/min with limits of agreements of -3.3 L/min and +2.9 L/min. The percentage error was 66.5%. The polar plot analysis included 71 significant ∆CO and showed a mean polar angle of -3.4 degrees with 95% polar percentage error equivalent limits of -61 to 55; 69% of analysed data points fell within the 30-degree limits and provided a correct polar concordance rate. CONCLUSIONS: Third-generation FloTrac/Vigileo software still lacks the accuracy to reliably detect changes in cardiac output (∆CO) in cardiac surgery. Improvements to FloTrac/Vigileo CO algorithm and software still are needed in this particular setting.


Assuntos
Débito Cardíaco/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Software , Adulto , Idoso , Idoso de 80 Anos ou mais , Interpretação Estatística de Dados , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Termodiluição/métodos
15.
Anesthesiology ; 116(3): 716-28, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22270506

RESUMO

Observational studies on transfusion in trauma comparing high versus low plasma:erythrocyte ratio were prone to survivor bias because plasma administration typically started later than erythrocytes. Therefore, early deaths were categorized in the low plasma:erythrocyte group, whereas early survivors had a higher chance of receiving a higher ratio. When early deaths were excluded, however, a bias against higher ratio can be created. Survivor bias could be reduced by performing before-and-after studies or treating the plasma:erythrocyte ratio as a time-dependent covariate.We reviewed 26 studies on blood ratios in trauma. Fifteen of the studies were survivor bias-unlikely or biased against higher ratio; among them, 10 showed an association between higher ratio and improved survival, and five did not. Eleven studies that were judged survivor bias-prone favoring higher ratio suggested that a higher ratio was superior.Without randomized controlled trials controlling for survivor bias, the current available evidence supporting higher plasma:erythrocyte resuscitation is inconclusive.


Assuntos
Transfusão de Eritrócitos , Plasma , Choque Hemorrágico/epidemiologia , Choque Hemorrágico/terapia , Sobreviventes , Viés , Transfusão de Eritrócitos/tendências , Humanos , Prevalência
16.
J Emerg Med ; 42(2): 174-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22056111

RESUMO

BACKGROUND: Cannulation of the internal jugular vein (IJV) is traditionally performed using the central-longitudinal approach. Pneumothorax, carotid artery puncture, and failure to cannulate are uncommon, but by no means rare, complications. Ultrasound (US) guidance for IJV cannulation has reduced but not eliminated such complications. TECHNIQUE: We herein introduce a new approach, coined the "medial-transverse approach" due to the perpendicular angle at which the introducer needle is advanced toward the IJV from the median to lateral direction. DISCUSSION: The direction of the introducer needle is not toward the lung, thus virtually eliminating the possibility of pneumothorax. The image of the entire needle is seen when the US probe is typically orientated for a short-axis view of the IJV and carotid artery, thus improving the chance of uncomplicated IJV puncture. We have used this technique with apparent success in thousands of cases over the past 20 years in two different institutions. CONCLUSION: A modified IJV cannulation technique that seems to have unique advantages over traditional approaches has been described. This technique is compatible with the blind and US-guided approaches.


Assuntos
Cateterismo Venoso Central/métodos , Veias Jugulares/cirurgia , Humanos , Veias Jugulares/diagnóstico por imagem , Posicionamento do Paciente , Pneumotórax/prevenção & controle , Ultrassonografia de Intervenção
18.
Curr Opin Crit Care ; 17(4): 323-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21716105

RESUMO

PURPOSE OF REVIEW: Thoracic trauma leading to multiple fractured ribs (MFR) remains very common. Good analgesia may help to improve a patient's respiratory mechanics and to avoid intubation of the trachea for ventilatory support and therefore may dramatically alter the course of recovery. We herein review the analgesia options for patients with MFR. RECENT FINDINGS: For healthy patients with one to two fractured ribs, systemic analgesics may suffice. For more than three to four fractured ribs, studies and experience have reaffirmed the superior analgesia made possible with thoracic epidural, thoracic paravertebral, and intercostal blocks. From experience, interpleural block has significant drawbacks. Catheterization allows the continuation of analgesia for 2 or more days with just one block. Use of the landmark technique is usually satisfactory for accurate block placement but ultrasound and nerve stimulation are showing promise in further improving needle and catheter placement accuracy, especially in the presence of difficult anatomy. SUMMARY: Thoracic epidural, thoracic paravertebral, and intercostal blocks are the top choices for patients with MFR and they are of equivalent efficacy. Each has unique advantages and disadvantages. Our preference tends to be the thoracic paravertebral approach.


Assuntos
Anestesia por Condução/métodos , Dor/tratamento farmacológico , Fraturas das Costelas/terapia , Traumatismos Torácicos/terapia , Doença Aguda , Anti-Inflamatórios não Esteroides/uso terapêutico , Humanos , Bloqueio Nervoso/métodos , Manejo da Dor , Medição da Dor/métodos , Fraturas das Costelas/diagnóstico por imagem , Fraturas das Costelas/patologia , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/patologia , Ultrassonografia
19.
Anesth Analg ; 113(3): 515-22, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21680855

RESUMO

BACKGROUND: Reliable cardiac output monitoring is particularly useful in the cirrhotic patient undergoing liver transplant surgery, because cirrhosis of the liver is associated with a vasodilated and high output state, known as cirrhotic cardiomyopathy, that challenges the reliability of pulse contour cardiac output technology. The contractility of the ventricle in cirrhosis is impaired, which is tolerated even though the ejection fraction and cardiac output are elevated because of the low peripheral resistance. However, during surgery the cirrhotic patient can decompensate because of the physiological changes and stress of surgery. Recently, we showed that the FloTrac/Vigileo™ failed to perform in cirrhotic patients undergoing transplant surgery. In response, the company upgraded their software. Therefore, we have assessed the accuracy and reliability of this new third-generation (version 3.02) FloTrac/Vigileo algorithm software in the same setting. METHODS: The cardiac index was measured simultaneously by single-bolus thermodilution (CI(TD)), using a pulmonary artery catheter, and pulse contour analysis, using the FloTrac/Vigileo (CI(V)). Readings were made at 10 time points during and after liver transplant surgery in 21 patients. Comparisons with data from our 2009 study, which used second-generation (version 01.10) software, were also made. RESULTS: Our new data show that version 3.02 software significantly reduced the adverse effect on pulse contour cardiac output reading bias in low peripheral resistance states, and thus improves the overall precision and trending ability of the system. Regression analysis between CI(TD) and CI(V) showed that the correlation was moderate (r =0.67, 95% confidence interval, 0.40 to 0.86). The Bland and Altman analysis showed that bias was 0.4 L.min(-1) · m(-2), and the percentage error was 52% (95% confidence interval, 49% to 55%). Trending ability of the new software also was improved but was still well below the current benchmarks. CONCLUSION: The new software (version 3.02) provided substantial improvements over the previous versions with better overall precision and trending ability. Further algorithm refinements will increase this technology's reliability to be extensively used in the highly complex setting of cirrhotic patients undergoing liver transplantation.


Assuntos
Pressão Sanguínea , Débito Cardíaco , Cardiomiopatias/fisiopatologia , Cateterismo Periférico/instrumentação , Cirrose Hepática/cirurgia , Transplante de Fígado , Monitorização Intraoperatória/instrumentação , Artéria Radial/fisiopatologia , Software , Adulto , Algoritmos , Cardiomiopatias/etiologia , Cateterismo de Swan-Ganz , Desenho de Equipamento , Feminino , Humanos , Itália , Cirrose Hepática/complicações , Cirrose Hepática/fisiopatologia , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Análise de Regressão , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Termodiluição , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA