Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Am Coll Radiol ; 21(1): 107-117, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37634790

RESUMO

BACKGROUND: Preferred size-threshold recommendations for management of incidental adrenal lesions remain controversial. PURPOSE: This meta-analysis aimed to compare the diagnostic accuracy of different size thresholds for detecting malignancy in patients with incidental adrenal lesions on imaging. MATERIALS AND METHODS: A systematic review of MEDLINE, Embase, Scopus, the Cochrane Library, and the gray literature, covering the period from inception to September 2021, was performed. Studies with >10 patients evaluating the diagnostic accuracy of imaging size thresholds for detecting malignancy in patients with incidental adrenal lesions and no prior history of cancer were included. Study, clinical, imaging, and accuracy data for eligible studies were independently acquired by two reviewers. Primary meta-analysis was performed using a bivariate mixed-effects regression model. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. RESULTS: From 2,690 citations, 40 studies (9,794 patients with mean age ranging from 41 to 66 years) were included. Most (36 of 40) were retrospective single-center studies. CT with or without MRI served as the index test(s). Sensitivity and specificity values, respectively, by size threshold used in the included studies were as follows: 85% (95% confidence interval [CI] 74%-91%) and 39% (95% CI 23%-57%) for 3-cm thresholds; 85% (95% CI 78%-90%) and 75% (95% CI 62%-85%) for 4-cm thresholds; 70% (95% CI 56%-81%) and 74% (95% CI 59%-85%) for 5-cm thresholds; and 75% (95% CI 67%-82%) and 77% (95% CI 62%-87%) for 6-cm thresholds. No cause for variability in sensitivity or specificity was identified on subgroup analysis of the 4-cm threshold. Nearly half of the studies (19 of 40) had at least one QUADAS-2 domain with a high risk of bias. CONCLUSIONS: A 4-cm size threshold demonstrates the highest combined sensitivity and specificity, with a preserved specificity compared with higher size thresholds, but with a trend toward improved sensitivity. Future research reevaluating 4-5 cm size thresholds while excluding characteristically benign lesions by imaging may help redefine a size threshold that has improved specificity but preserved sensitivity, compared with the existing 4-cm threshold.


Assuntos
Melanoma Maligno Cutâneo , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética
2.
World J Radiol ; 14(9): 319-328, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36186517

RESUMO

BACKGROUND: The 2018 ovarian-adnexal reporting and data system (O-RADS) guidelines are aimed at providing a system for consistent reports and risk stratification for ovarian lesions found on ultrasound. It provides key characteristics and findings for lesions, a lexicon of descriptors to communicate findings, and risk characterization and associated follow-up recommendation guidelines. However, the O-RADS guidelines have not been validated in North American institutions or amongst less experienced readers. AIM: To evaluate the diagnostic accuracy and inter-reader reliability of ultrasound O-RADS risk stratification amongst less experienced readers in a North American institution with and without pre-test training. METHODS: A single-center retrospective study was performed using 100 ovarian/adnexal lesions of varying O-RADS scores. Of these cases, 50 were allotted to a training cohort and 50 to a testing cohort via a non-randomized group selection process in order to approximately equal distribution of O-RADS categories both within and between groups. Reference standard O-RADS scores were established through consensus of three fellowship-trained body imaging radiologists. Three PGY-4 residents were independently evaluated for diagnostic accuracy and inter-reader reliability with and without pre-test O-RADS training. Sensitivity, specificity, positive predictive value, negative predictive value (NPV), and area under the curve (AUC) were used to measure accuracy. Fleiss kappa and weighted quadratic (pairwise) kappa values were used to measure inter-reader reliability. Statistical significance was P < 0.05. RESULTS: Mean patient age was 40 ± 16 years with lesions ranging from 1.2 to 22.5 cm. Readers demonstrated excellent specificities (85%-100% pre-training and 91%-100% post-training) and NPVs (89%-100% pre-training and 91-100% post-training) across the O-RADS categories. Sensitivities were variable (55%-100% pre-training and 64%-100% post-training) with malignant O-RADS 4 and 5 Lesions pre-training and post-training AUC values of 0.87-0.95 and 0.94-098, respectively (P < 0.001). Nineteen of 22 (86%) misclassified cases in pre-training were related to mischaracterization of dermoid features or wall/septation morphology. Fifteen of 17 (88%) of post-training misclassified cases were related to one of these two errors. Fleiss kappa inter-reader reliability was 'good' and pairwise inter-reader reliability was 'very good' with pre-training and post-training assessment (k = 0.76 and 0.77; and k = 0.77-0.87 and 0.85-0.89, respectively). CONCLUSION: Less experienced readers in North America achieved excellent specificities and AUC values with very good pairwise inter-reader reliability. They may be subject to misclassification of potentially malignant lesions, and specific training around dermoid features and smooth vs irregular inner wall/septation morphology may improve sensitivity.

3.
J Ultrason ; 22(88): e51-e56, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35449702

RESUMO

Thyroid nodules are very common in the general population. Most are benign and even those that are malignant are typically slow-growing and do not require treatment. Overdiagnosis and overtreatment of thyroid nodules has resulted in significant healthcare costs. ACR TI-RADS was developed to address these concerns, and reduce the number of unnecessary biopsies and follow-up intervals. ACR TI-RADS offers a point-based risk stratification system centered on five sonographic features: consistency, echogenicity, shape, margins and echogenic foci. While the system has noticeable benefits and comparable accuracy with other available risk stratification systems (ATA, EU-TIRADS and K-TIRADS), there are inherent challenges relating to suboptimal inter-reader agreement. In this article, we include 10 educational tips that may be helpful to the ultrasound practitioner for improving the consistency of nodule interpretation with ACR TI-RADS.

4.
World J Radiol ; 14(1): 19-29, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35126875

RESUMO

BACKGROUND: The American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) was introduced to standardize the ultrasound characterization of thyroid nodules. Studies have shown that ACR-TIRADS reduces unnecessary biopsies and improves consistency of imaging recommendations. Despite its widespread adoption, there are few studies to date assessing the inter-reader agreement amongst radiology trainees with limited ultrasound experience. We hypothesize that in PGY-4 radiology residents with no prior exposure to ACR TI-RADS, a statistically significant improvement in inter-reader reliability can be achieved with a one hour training session. AIM: To evaluate the inter-reader agreement of radiology residents in using ACR TI-RADS before and after training. METHODS: A single center retrospective cohort study evaluating 50 thyroid nodules in 40 patients of varying TI-RADS levels was performed. Reference standard TI-RADS scores were established through a consensus panel of three fellowship-trained staff radiologists with between 1 and 14 years of clinical experience each. Three PGY-4 radiology residents (trainees) were selected as blinded readers for this study. Each trainee had between 4 to 5 mo of designated ultrasound training. No trainee had received specialized TI-RADS training prior to this study. Each of the readers independently reviewed the 50 testing cases and assigned a TI-RADS score to each case before and after TI-RADS training performed 6 wk apart. Fleiss kappa was used to measure the pooled inter-reader agreement. The relative diagnostic performance of readers, pre- and post-training, when compared against the reference standard. RESULTS: There were 33 females and 7 males with a mean age of 56.6 ± 13.6 years. The mean nodule size was 19 ± 14 mm (range from 5 to 63 mm). A statistically significant superior inter-reader agreement was found on the post-training assessment compared to the pre-training assessment for the following variables: 1. "Shape" (k of 0.09 [slight] pre-training vs 0.67 [substantial] post-training, P < 0.001), 2. "Echogenic foci" (k of 0.28 [fair] pre-training vs 0.45 [moderate] post-training, P = 0.004), 3. 'TI-RADS level' (k of 0.14 [slight] pre-training vs 0.36 [fair] post-training, P < 0.001) and 4. 'Recommendations' (k of 0.36 [fair] pre-training vs 0.50 [moderate] post-training, P = 0.02). No significant differences between the pre- and post-training assessments were found for the variables 'composition', 'echogenicity' and 'margins'. There was a general trend towards improved pooled sensitivity with TI-RADS levels 1 to 4 for the post-training assessment while the pooled specificity was relatively high (76.6%-96.8%) for all TI-RADS level. CONCLUSION: Statistically significant improvement in inter-reader agreement in the assigning TI-RADS level and recommendations after training is observed. Our study supports the use of dedicated ACR TI-RADS training in radiology residents.

5.
J Orthop Res ; 39(10): 2187-2196, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33247597

RESUMO

Magnetic resonance imaging findings often do not distinguish between people with and without low back pain (LBP). However, there are still a large number of people who undergo magnetic resonance imaging to help determine the etiology of their back pain. Texture analysis shows promise for the classification of tissues that look similar, and machine learning can minimize the number of comparisons. This study aimed to determine if texture features from lumbar spine magnetic resonance imaging differ between people with and without LBP. In total, 14 participants with chronic LBP were matched for age, weight, and gender with 14 healthy volunteers. A custom texture analysis software was used to construct a gray-level co-occurrence matrix with one to four pixels offset in 0° direction for the disc and superior and inferior endplate regions. The Random Forests Algorithm was used to select the most promising classifiers. The linear mixed-effect model analysis was used to compare groups (pain vs. pain-free) at each level controlling for age. The Random Forest Algorithm recommended focusing on intervertebral discs and endplate zones at L4-5 and L5-S1. Differences were observed between groups for L5-S1 superior endplate contrast, homogeneity, and energy (p = .02). Differences were observed for L5-S1 disc contrast and homogeneity (p < .01), as well as for the inferior endplates contrast, homogeneity, and energy (p < .03). Magnetic resonance imaging textural features may have potential in identifying structures that may be the target of further investigations about the reasons for LBP.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Dor Lombar , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/patologia , Dor Lombar/diagnóstico por imagem , Dor Lombar/etiologia , Dor Lombar/patologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Região Lombossacral , Imageamento por Ressonância Magnética/métodos
6.
BMC Musculoskelet Disord ; 14: 353, 2013 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-24330551

RESUMO

BACKGROUND: Limited intrinsic healing potential of the meniscus and a strong correlation between meniscal injury and osteoarthritis have prompted investigation of surgical repair options, including the implantation of functional bioengineered constructs. Cell-based constructs appear promising, however the generation of meniscal constructs is complicated by the presence of diverse cell populations within this heterogeneous tissue and gaps in the information concerning their response to manipulation of oxygen tension during cell culture. METHODS: Four human lateral menisci were harvested from patients undergoing total knee replacement. Inner and outer meniscal fibrochondrocytes (MFCs) were expanded to passage 3 in growth medium supplemented with basic fibroblast growth factor (FGF-2), then embedded in porous collagen type I scaffolds and chondrogenically stimulated with transforming growth factor ß3 (TGF-ß3) under 21% (normal or normoxic) or 3% (hypoxic) oxygen tension for 21 days. Following scaffold culture, constructs were analyzed biochemically for glycosaminoglycan production, histologically for deposition of extracellular matrix (ECM), as well as at the molecular level for expression of characteristic mRNA transcripts. RESULTS: Constructs cultured under normal oxygen tension expressed higher levels of collagen type II (p = 0.05), aggrecan (p < 0.05) and cartilage oligomeric matrix protein, (COMP) (p < 0.05) compared to hypoxic expanded and cultured constructs. Accumulation of ECM rich in collagen type II and sulfated proteoglycan was evident in normoxic cultured scaffolds compared to those under low oxygen tension. There was no significant difference in expression of these genes between scaffolds seeded with MFCs isolated from inner or outer regions of the tissue following 21 days chondrogenic stimulation (p > 0.05). CONCLUSIONS: Cells isolated from inner and outer regions of the human meniscus demonstrated equivalent differentiation potential toward chondrogenic phenotype and ECM production. Oxygen tension played a key role in modulating the redifferentiation of meniscal fibrochondrocytes on a 3D collagen scaffold in vitro.


Assuntos
Condrócitos/citologia , Matriz Extracelular/metabolismo , Fibroblastos/citologia , Meniscos Tibiais/citologia , Oxigênio/fisiologia , Idoso , Agrecanas/metabolismo , Proteína de Matriz Oligomérica de Cartilagem/metabolismo , Desdiferenciação Celular , Diferenciação Celular , Células Cultivadas , Condrócitos/metabolismo , Condrogênese , Colágeno Tipo I/metabolismo , Colágeno Tipo II/metabolismo , Feminino , Fibroblastos/metabolismo , Expressão Gênica , Humanos , Meniscos Tibiais/metabolismo , Pessoa de Meia-Idade , Fenazinas , Fenótipo , Alicerces Teciduais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA