Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 688
Filtrar
1.
Orbit ; : 1-4, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796753

RESUMO

An 88-year-old male patient presented with a large mass on the left lateral bulbar conjunctiva. The tumor appeared two months after the resection of a conjunctival atypical fibroxanthoma (AFX) performed by a cornea specialist. Magnetic resonance imaging of the orbits showed deep orbital invasion along the lateral rectus muscle. The mass and the entire conjunctival sac were totally excised with lid-sparing orbital exenteration. Histopathological analysis confirmed that the mass was an extension of the AFX. Two weeks after surgery, large B-cell lymphoma was diagnosed in the oropharynx. Chemotherapy was initiated, and after seven months of follow-up, there was no recurrence of the AFX. The authors believe that this is the first report of orbital invasion by AFX.

2.
Ophthalmic Plast Reconstr Surg ; 40(3): 336-339, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738711

RESUMO

PURPOSE: To investigate the relationship between the kinematics of spontaneous blinks and the anterior area of the levator palpebrae superioris muscle in patients with Graves orbitopathy (GO). METHODS: This is a case-control study. The authors measured the margin reflex distance of the upper eyelid (margin reflex distance 1), the kinematics of spontaneous blinks, and the anterior area of levator palpebrae superioris muscle in CT coronal scans of patients with Graves upper eyelid retraction (GO) and a control group. The eye with the greatest margin reflex distance 1 was selected for analysis in each group. RESULTS: A total of 68 participants were included, with 36 in the GO group and 32 in the control group. In the GO group, the mean margin reflex distance 1 measured 6.5 mm, while in the control group, it was 3.9 mm. Almost all parameters related to the closing phase of spontaneous blinking activity, including amplitude, velocity, blinking rate, and interblink time, did not differ between the two groups. However, the effectiveness of the blink's amplitude (ratio of blink amplitude to margin reflex distance 1) and the main sequence (relationship between amplitude and velocity) were significantly reduced in the GO group compared with the control group. The area of the levator palpebrae superioris muscle was significantly larger in GO than in controls, with 71.4% of patients' muscles outside of the maximum range of the controls. CONCLUSIONS: In patients with GO, there is a reduction in blinking effectiveness, also known as blink lagophthalmos, which is a factor in the common occurrence of ocular surface symptoms. The increase in velocity with amplitude is also reduced in GO.


Assuntos
Piscadela , Pálpebras , Oftalmopatia de Graves , Músculos Oculomotores , Humanos , Piscadela/fisiologia , Feminino , Oftalmopatia de Graves/fisiopatologia , Oftalmopatia de Graves/complicações , Oftalmopatia de Graves/diagnóstico , Masculino , Pessoa de Meia-Idade , Músculos Oculomotores/fisiopatologia , Adulto , Estudos de Casos e Controles , Pálpebras/fisiopatologia , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/diagnóstico , Idoso , Tomografia Computadorizada por Raios X , Lagoftalmia
3.
Biomedicines ; 12(5)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38790999

RESUMO

Pain is the most frequent symptom of disease. In treating pain, a lower incidence of adverse effects is found for paracetamol versus other non-steroidal anti-inflammatory drugs. Nevertheless, paracetamol can trigger side effects when taken regularly. Combined therapy is a common way of lowering the dose of a drug and thus of reducing adverse reactions. Since ß-caryophyllene oxide (a natural bicyclic sesquiterpene) is known to produce an analgesic effect, this study aimed to determine the anti-nociceptive and gastroprotective activity of administering the combination of paracetamol plus ß-caryophyllene oxide to CD1 mice. Anti-nociception was evaluated with the formalin model and gastroprotection with the model of ethanol-induced gastric lesions. According to the isobolographic analysis, the anti-nociceptive interaction of paracetamol and ß-caryophyllene oxide was synergistic. Various pain-related pathways were explored for their possible participation in the mechanism of action of the anti-nociceptive effect of ß-caryophyllene oxide, finding that NO, opioid receptors, serotonin receptors, and K+ATP channels are not involved. The combined treatment showed gastroprotective activity against ethanol-induced gastric damage. Hence, the synergistic anti-nociceptive effect of combining paracetamol with ß-caryophyllene oxide could be advantageous for the management of inflammatory pain, and the gastroprotective activity should help to protect against the adverse effects of chronic use.

4.
JMIR Aging ; 7: e50219, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639994

RESUMO

BACKGROUND: There is a need to develop and coordinate dementia care plans that use assistive technology for vulnerable groups such as immigrant populations. However, immigrant populations are seldom included in various stages of the development and implementation of assistive technology, which does not optimize technology acceptance. OBJECTIVE: This study aims to gain an in-depth understanding of the acceptance of a digital personal assistant, called Anne4Care, by older adult immigrants living with dementia in their own homes. METHODS: This study used a qualitative descriptive research design with naturalistic inquiry. A total of 13 older adults participated in this study. The participants were invited for 2 interviews. After an introduction of Anne4Care, the first interview examined the lives and needs of participants, their expectations, and previous experiences with assistive technology in daily life. Four months later, the second interview sought to understand facilitators and barriers, suggestions for modifications, and the role of health care professionals. Three semistructured interviews were conducted with health care professionals to examine the roles and challenges they experienced in the use and implementation of Anne4Care. Content analysis, using NVivo11, was performed on all transcripts. RESULTS: All 13 participants had an immigration background. There were 10 male and 3 female participants, with ages ranging from 52 to 83 years. Participants were diagnosed with an early-stage form of dementia or acquired brain injury. None of the older adult participants knew or used digital assistive technology at the beginning. They obtained assistance from health care professionals and family caregivers who explained and set up the technology. Four themes were found to be critical aspects of the acceptance of the digital personal assistant Anne4Care: (1) use of Anne4Care, (2) positive aspects of Anne4Care, (3) challenges with Anne4Care, and (4) expectations. Assistance at first increased the burden on health care professionals and families. After the initial effort, most health care professionals and families experienced that Anne4Care reduced their tasks and stress. Contributions of Anne4Care included companionship, help with daily tasks, and opportunities to communicate in multiple languages. On the other hand, some participants expressed anxiety toward the use of Anne4Care. Furthermore, the platform required an internet connection at home and Anne4Care could not be used outside the home. CONCLUSIONS: Although older adult immigrants living with dementia had no previous experience with digital assistive technology specifically, the acceptance of the digital personal assistant, called Anne4Care, by older adult immigrants living with dementia was rather high. The digital assistant can be further developed to allow for interactive conversations and for use outside of one's home. Participation of end users during various stages of the development, refinement, and implementation of health technology innovations is of utmost importance to maximize technology acceptance.


Assuntos
Demência , Emigrantes e Imigrantes , Tecnologia Assistiva , Humanos , Masculino , Feminino , Idoso , Demência/diagnóstico , Cuidadores , Pesquisa Qualitativa
6.
Artigo em Inglês | MEDLINE | ID: mdl-38534073

RESUMO

PURPOSE: To measure the spontaneous blinking metrics after blepharoptosis correction with frontalis muscle flap advancement. METHODS: A video system was employed to measure the amplitude and velocity of spontaneous blinking of 24 eyelids after the frontalis muscle flap surgery for blepharoptosis correction. A control group with no eyelid disorders was also measured. The data of 13 eyelids who had frontalis slings with autogenous fascia, which were previously collected with the same method in another study, were used for comparison. Digital images were used to measure the superior margin reflex distance and the presence of lagophthalmos during a gentle closure of the palpebral fissure. Superficial keratitis was assessed by corneal biomicroscopy. RESULTS: The mean amplitude of spontaneous blinking was 6.3 mm in controls, 2.6 mm in the frontalis flap patients, and 2.1 mm in the fascia sling group. The mean blink velocity was 133.8 mm/second in controls, 39.0 mm/second (3.7 standard error) after the frontalis flap, and 36.3 mm/second in patients with frontalis sling with fascia. For these 2 parameters, there was no statistical difference between the surgical groups, but a significant reduction when compared with the control group. No significant association was found between lagophthalmos and keratitis and the surgical procedure. CONCLUSIONS: There is no difference between the blinking metrics of eyelids operated using the frontalis muscle flap advancement technique or frontalis sling with autogenous fascia. The presence of lagophthalmos and keratitis also does not differ between the 2 procedures.

7.
Personal Neurosci ; 7: e6, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38384665

RESUMO

Despite being one of the main components of anxiety and playing a pivotal role in how an individual perceives and copes with anxiogenic situations or responds to a given treatment, trait anxiety is paradoxically omitted in most animal models of anxiety. This is problematic and particularly more concerning in models that are used to screen drugs and other treatments for specific anxiety disorders and to investigate their neurobiological mechanisms. Our group has been engaged in the search for specific anxiety-related traits in animal models of anxiety. We developed two new lines of rats with strong phenotypic divergence for high (Carioca High-conditioned Freezing [CHF]) and low (Carioca Low-conditioned Freezing [CLF]) trait anxiety as expressed in the contextual fear conditioning paradigm. Here, we summarize key behavioral, pharmacological, physiological, and neurobiological differences in one these lines, the CHF rat line, relative to randomized-cross controls and discuss how far they represent a valid and reliable animal model of generalized anxiety disorder and so high trait anxiety.

8.
Can J Aging ; : 1-8, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372162

RESUMO

BACKGROUND: The COVID-19 pandemic created many challenges for in-patient care including patient isolation and limitations on hospital visitation. Although communication technology, such as video calling or texting, can reduce social isolation, there are challenges for implementation, particularly for older adults. OBJECTIVE/METHODS: This study used a mixed methodology to understand the challenges faced by in-patients and to explore the perspectives of patients, family members, and health care providers (HCPs) regarding the use of communication technology. Surveys and focus groups were used. FINDINGS: Patients who had access to communication technology perceived the COVID-19 pandemic to have more adverse impact on their well-beings but less on hospitalization outcomes, compared to those without. Most HCPs perceived that technology could improve programs offered, connectedness of patients to others, and access to transitions of care supports. Focus groups highlighted challenges with technology infrastructure in hospitals. DISCUSSION: Our study findings may assist efforts in appropriately adopting communication technology to improve the quality of in-patient and transition care.

9.
Can J Aging ; : 1-15, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38297497

RESUMO

Worldwide, over 55-million people have dementia, and the number will triple by 2050. Persons living with dementia are exposed to risks secondary to cognitive challenges including getting lost. The adverse outcomes of going missing include injuries, death, and premature institutionalization. In this scoping review, we investigate risk factors associated with going missing among persons living with dementia. We searched and screened studies from four electronic databases (Medline, CINAHL, Embase, and Scopus), and extracted relevant data. We identified 3,376 articles, of which 73 met the inclusion criteria. Most studies used quantitative research methods. We identified 27 variables grouped into three risk factor domains: (a) demographics and personal characteristics, (b) health conditions and symptoms, and (c) environmental and contextual antecedents. Identification of risk factors associated with getting lost helps to anticipate missing incidents. Risk factors can be paired with proactive strategies to prevent incidents and inform policies to create safer communities.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38215463

RESUMO

PURPOSE: To review existing literature concerning the effectiveness and safety of tocilizumab (TCZ) for managing thyroid eye disease. METHODS: A systematic search was conducted across the PubMed and Embase databases to identify studies on TCZ therapy, from inception to May 2023. The search included the keywords "Graves orbitopathy," "thyroid ophthalmopathy," "thyroid eye disease," "thyroid-associated orbitopathy," "thyroid-associated ophthalmopathy," "Graves ophthalmopathy," "endocrine ophthalmopathy," and "Tocilizumab." Only articles written in English, Spanish, or French were considered. RESULTS: Among the 1,013 articles initially screened, a total of 29 fulfilled the eligibility criteria and were selected. Most studies were case reports or case series, and only one randomized clinical trial was found. TCZ has been used mainly in glucocorticoid-resistant or relapsing cases, with a dosage ranging from 4 or 8 mg/kg every 4 weeks when intravenous or a weekly subcutaneous dose of 162 mg. Treatment duration is usually adjusted to the clinical response. TCZ is mostly effective in reducing inflammatory signs during the active phase of thyroid eye disease, with an improvement of at least 3 points in clinical activity score and an overall relapsing rate of 8.2%. Numerous studies have shown marked reductions in proptosis; although the only available randomized controlled trial reported a nonstatistically significant improvement 6 months after treatment, a recent meta-analysis indicated that TCZ seems to be the most effective treatment for reducing proptosis. No severe side effects related to intravenous or subcutaneous TCZ administration were reported. DISCUSSION: Despite these promising findings, randomized clinical trials to directly compare the efficacy and safety of TCZ and other currently available therapeutic options are needed.

11.
Dig Dis Sci ; 69(2): 399-409, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38170334

RESUMO

BACKGROUND AND AIMS: Self-management skills improve outcomes for patients with cirrhosis. While education programs exist to teach these skills, there are limited patient assessments to evaluate their efficacy. We aimed to develop and evaluate cirrhosis knowledge assessments for patients with compensated and decompensated cirrhosis. METHODS: Across two institutions, a 4-stage process was undertaken: first, we developed a comprehensive set of questions regarding cirrhosis self-management. Second, the questions underwent critical review by patients and hepatology providers. Third, patients with cirrhosis answered these questions before and after a written educational tool. Questions were updated based on results. Fourth, patients answered the updated questions before and after a video educational tool. Binomial test or paired sample t-test was used to compare pre- and post-tests depending on question type. RESULTS: In phase 3, 134 patients completed pre- and post-tests. 44% were decompensated, 81% were diagnosed with cirrhosis at least 3 years, and 52% were 60-75 years. 95% of single-answer questions were answered correctly by at least 70% of patients in the pre-test. None of the answers improved significantly with education. After phase 3, 6 questions were removed and 6 questions were edited to increase challenge. In phase 4, 96 patients (42 compensated, 54 decompensated) completed pre- and post-tests. In the compensated assessment, 3 questions improved after education and the summative score increased (7.9 to 9.0, P < 0.001). In the decompensated assessment, 4 questions improved after education and the summative score increased (7.0 to 7.7, P = 0.004). CONCLUSION: Through a rigorous process, we created and evaluated cirrhosis knowledge assessments for patients with compensated and decompensated cirrhosis. Further validation is required and then these assessments can be used to improve patient education.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Cirrose Hepática , Autogestão , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/terapia , Educação de Pacientes como Assunto , Pessoa de Meia-Idade , Idoso
15.
Arq. bras. oftalmol ; 87(6): e2022, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513692

RESUMO

ABSTRACT Orbital decompression is widely performed for the management of proptosis for cosmetic and functional cases of Graves orbitopathy. The main side effects include dry eye, diplopia, and numbness. Blindness after orbital decompression is extremely rare. The mechanisms of vision loss after decompression are not well described in the literature. Considering the devastating effect and rarity of this complication, this study presented two cases of blindness after orbital decompression. In both cases, vision loss was provoked by slight bleeding in the orbital apex.


RESUMO A descompressão orbitária é uma cirurgia amplamente empregada para correção da proptose em casos cosméticos e funcionais da orbitopatia de Graves. Os principais efeitos colaterais induzidos pela descompressão são olho seco, diplopia e parestesias. Amaurose pós descompressão é uma complicação extremamente rara e cujos mecanismos são pouco discutidos na literatura. Considerando o efeito devastador representado pela perda visual e a escassez de relatos dessa complicação, os autores apresentam dois relatos de amaurose após descompressão orbitária. Nos dois casos a perda visual ocorreu devido a sangramento de pequena monta no ápice orbitário.

16.
Ophthalmic Plast Reconstr Surg ; 39(6S): S40-S45, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38054984

RESUMO

PURPOSE: The purpose of this study was to analyze Rundle's original data and subsequent articles on Graves orbitopathy (GO) natural history. METHODS: Rundle's texts were analyzed qualitatively and quantitatively. Serial measurements were plotted and fitted with different functions. Subsequent articles in the English literature on the natural history of GO were also analyzed. RESULTS: Different functions such as simple linear regressions, parabolic, saturating exponential growth, and exponential decay functions were well fitted for Rundle's data on measurements of proptosis and supraduction along time. The few quantitative data of the same variables post-Rundle were also well-fitted with various functions. CONCLUSION: Rundle described in his articles, from 1945 to 1957, 2 phases of ocular changes in GO: dynamic and static. However, he did not mention the pathophysiology of these phases nor used the terms inflammatory and cicatricial. Actually, most of his observations and the subsequent data in the literature on proptosis and supraduction did not obey the biphasic pattern of the so-called Rundle's curve.


Assuntos
Exoftalmia , Oftalmopatia de Graves , Masculino , Humanos , Exoftalmia/diagnóstico , Olho , Face
17.
Arq Bras Oftalmol ; 86(6): 1006, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38126533
18.
Orbit ; : 1-9, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37942625

RESUMO

PURPOSE: To review the literature on the location of the anterior ethmoidal foramen (AEF) and trauma during transconjunctival medial wall decompression. METHODS: A comprehensive literature search was conducted using the PubMed, Embase, and Scopus databases, combining the terms "olfactory fossa" and "fovea ethmoidalis" with "trauma," "cerebrospinal fluid leak," "pneumocephalus," "orbital decompression," and "anterior ethmoidal artery" (AEA). All cases of cranial base trauma during medial orbital decompression and the anatomical studies on the location of the AEF and the course of the AEA were reviewed. RESULTS: Ninety-four articles were identified, of which 37 were related to the AEF, 41 reported the course of the AEA, and 16 to reported cases of cranial base trauma. Out of these cases, 10 were related to transconjunctival medial orbital decompression, affecting 11 patients. Most AEFs are situated at the frontoethmoidal suture, but up to 38.15% of AEFs are located above the suture on the frontal bone. Most AEFs are adjacent to the roof of the ethmoidal sinus. The distance of the AEF to the cranial base increases in the presence of supraorbital ethmoidal cells (SOEC). CONCLUSIONS: The position of the AEF is variable and should not be considered a safe landmark for all patients.

19.
Arq Bras Oftalmol ; 87(6): e20220006, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37851738

RESUMO

Orbital decompression is widely performed for the management of proptosis for cosmetic and functional cases of Graves orbitopathy. The main side effects include dry eye, diplopia, and numbness. Blindness after orbital decompression is extremely rare. The mechanisms of vision loss after decompression are not well described in the literature. Considering the devastating effect and rarity of this complication, this study presented two cases of blindness after orbital decompression. In both cases, vision loss was provoked by slight bleeding in the orbital apex.


Assuntos
Oftalmopatia de Graves , Humanos , Oftalmopatia de Graves/cirurgia , Órbita/cirurgia , Descompressão Cirúrgica/efeitos adversos , Cegueira/etiologia , Estudos Retrospectivos
20.
Int J Med Inform ; 179: 105235, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37806176

RESUMO

BACKGROUND: Acquired brain injury (ABI) can lead to significant impairments and difficulties in everyday life, necessitating the need for rehabilitation. Mixed-reality (MR) technologies have revolutionized the delivery of neurorehabilitation therapies. However, inconsistencies in research methodology, diverse study populations and designs, and exaggerated claims in the research, media, and private consumer sectors have impacted the knowledge base of the field, including within the context of ABI rehabilitation. OBJECTIVE: This scoping review aims to explore MR-systems in ABI rehabilitation, while assessing the evidence base and technology readiness levels of these systems. METHODS: Seven databases were searched for studies, which were screened and analyzed by two independent raters. The types of MR systems, levels of evidence, and technology readiness levels were extracted and analyzed using descriptive analyses. RESULTS: Twenty-six studies were included in the review, all of which focused on ABI etiologies stemming from strokes. Across studies, upper-limb motor rehabilitation was the most common rehabilitation target of MR interventions, followed by gait, cognition, and lower-extremity functioning. At present, overall results indicate low evidence for MR-applications in ABI rehabilitation, with a median technology readiness level of 6, corresponding to system prototypes being tested in relevant environments. CONCLUSION: Although challenges regarding system usability and design were reported, results appear promising with ongoing research. With variability across studies, technologies, and populations, determining the effectiveness of MR interventions in ABI remains a challenge, necessitating the need for ongoing innovation, research, and development of these systems.


Assuntos
Lesões Encefálicas , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Lesões Encefálicas/reabilitação , Reabilitação do Acidente Vascular Cerebral/métodos , Cognição , Extremidade Superior
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA