Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Food Chem ; 438: 137932, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-37979271

RESUMO

"Empty cup aroma" is an important characteristic and quality evaluation standard of Jiangxiang-type Baijiu (JXB). In this study, an in situ detection method for the empty cup aroma of JXB was established, and the authenticity and origin information of JXB were identified with an untargeted flavoromics strategy. The complex composition of JXB leads to slow ethanol volatilization, which is a potential method for identifying artificial JXB. The results of the sensory analysis showed that acidic, sauce, burnt and qu in the empty cup of JXB were the strongest at the 45 min stage. A total of 155 compounds were detected in the empty cups of 15 JXB from different regions during 45 min of standing, and 34 compounds were identified as key aroma compounds in the empty cups of JXB. Eleven potential markers were screened (VIP > 1), which can be used to distinguish JXB produced in Guizhou/Sichuan and other regions.


Assuntos
Odorantes , Compostos Orgânicos Voláteis , Odorantes/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Compostos Orgânicos Voláteis/análise , Etanol/análise , Volatilização
2.
Anal Bioanal Chem ; 411(27): 7251-7260, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31612256

RESUMO

Chloride widely exists in the environment and will cause serious interference for arsenic speciation analysis. The determination of four arsenic species including arsenite (As(III)), arsenate (As(V)), monomethylarsenate (MMA), and dimethylarsonate (DMA) in samples containing high concentrations of Cl- was carried out in this work by coupling of liquid chromatography (LC) with hydride generation atomic fluorescence spectrometry (HG-AFS). The interference of Cl- was successfully eliminated by coupling two anion-exchange chromatographic columns in series and eluting with 35.0 mmol L-1 (NH4)2HPO4 (pH = 6.00). A novel pre-treatment system was subsequently developed to realize on-line column switch and pre-reduction of As(V). The analysis time was shortened by an isocratic elution but programmed flow rate method, and the sensitivity of As(V) was also enhanced by the introduction of pre-reduction using the developed system. The proposed method can resist at least 10 g L-1 Cl- without any pre-treatment operations. Since LC-HG-AFS is low-cost and can be afforded or self-assembled by most labs, the developed method can be adopted as a routine analysis method for arsenic species in chloride-bearing samples, such as urine and seawater. Graphical abstract.


Assuntos
Arseniatos/análise , Arsenicais/análise , Arsenitos/análise , Poluentes Químicos da Água/análise , Arseniatos/urina , Arsênio/análise , Arsênio/urina , Arsenicais/urina , Arsenitos/urina , Cloretos/análise , Cloretos/urina , Cromatografia Líquida de Alta Pressão/instrumentação , Desenho de Equipamento , Humanos , Limite de Detecção , Metilação , Água do Mar/análise , Espectrometria de Fluorescência/instrumentação , Espectrofotometria Atômica/instrumentação , Poluentes Químicos da Água/urina
3.
Int J Anal Chem ; 2019: 3280840, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31275389

RESUMO

A sensitive and accurate simultaneous continuous analysis for six arsenic species including arsenobetaine (AsB), arsenocholine (AsC), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenite (AsIII), and arsenate (AsV) has been developed by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). An anion-exchange column of Hamilton PRP-X100 (Switzerland) was applied for separation of the six arsenic species with gradient elution of 1.25 mmol/L Na2HPO4 and 11.0 mmol/L KH2PO4 as the mobile phase A and 2.5 mmol/L Na2HPO4 and 22.0 mmol/L KH2PO4 as the mobile phase B. The linearity ranges for AsB, AsC, MMA, DMA, AsIII, and AsV were between 0.5 and 50.0 µg/L, and the detection limits of the six arsenic species were all within 0.01-0.35 ng/L. The relative standard deviations (RSDs) were within 2.26-3.68% and the recovery rates of samples ranged from 95 to 103%. The proposed method was applied for the arsenic speciation analysis of sediment pore-water samples, which were taken from the supernatant after centrifugation and filtration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA