Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
2.
J Educ Perioper Med ; 26(1): E720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38516146

RESUMO

Background: Academic inquiry is foundational to the advancement of medicine and resident training and must be demonstrated to the Accreditation Council for Graduate Medical Education. Past attempts at increasing publication rates have failed to identify educational best practice models. Our aim was to increase resident publication rates via culture and value changes that are universally implementable, affordable, effective, and sustainable. Methods: In 2018, a multifaceted initiative was implemented to shift departmental values and foster a culture of academic productivity. This culture change stressed the value of scientific publication through frequent, consistent messaging from department leaders. In addition, residents were provided the freedom to choose their scholarly activities. In this retrospective cohort innovation, resident authors were identified for 4 academic years before and after the intervention and publication rates were determined (2014-2018 vs 2018-2022). Resident authors and publications per resident per year were compared using descriptive statistics and Student t test. Results: The pre- and postintervention groups included 38 and 37 residents, respectively. Resident-authored publications increased from 7 preintervention to 24 postintervention, representing 343% of baseline. Mean ± SD publications per resident per year similarly increased 357% from 0.183 ± 0.16 to 0.654 ± 0.11 postintervention. Unpaired t test analysis demonstrated a significant difference in total publications per year (P = .002) and authorship rate (P = .003). Conclusions: A multifaceted academic initiative resulted in a threefold increase in resident publication rates. This initiative demonstrates that local advocacy by leaders, freedom of choice for authors, and supportive departmental culture are driving factors in publication rates.

3.
Proc (Bayl Univ Med Cent) ; 37(1): 48-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38174013

RESUMO

Purpose: Hypoxemia during a failed airway scenario is life threatening. A dual-lumen pharyngeal oxygen delivery device (PODD) was developed to fit inside a traditional oropharyngeal airway for undisrupted supraglottic oxygenation and gas analysis during laryngoscopy and intubation. We hypothesized that the PODD would provide oxygen as effectively as high-flow nasal cannula (HFNC) while using lower oxygen flow rates. Methods: We compared oxygen delivery of the PODD to HFNC in a preoxygenated, apneic manikin lung that approximated an adult functional residual capacity. Four arms were studied: HFNC at 20 and 60 liters per minute (LPM) oxygen, PODD at 10 LPM oxygen, and a control arm with no oxygen flow after initial preoxygenation. Five randomized 20-minute trials were performed for each arm (20 trials total). Descriptive statistics and analysis of variance were used with statistical significance of P < 0.05. Results: Mean oxygen concentrations were statistically different and decreased from 97% as follows: 41 ± 0% for the control, 90 ± 1% for HFNC at 20 LPM, 88 ± 2% for HFNC at 60 LPM, and 97 ± 1% (no change) for the PODD at 10 LPM. Conclusion: Oxygen delivery with the PODD maintained oxygen concentration longer than HFNC in this manikin model at lower flow rates than HFNC.

4.
Proc (Bayl Univ Med Cent) ; 37(1): 61-62, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38174022
6.
A A Pract ; 17(2): e01661, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36779873

RESUMO

Central venous catheterization is a common procedure that may lead to inadvertent arterial cannulation, potentially causing bleeding, hematoma, stroke or rarely, death. In this near-miss case presentation, an aneurysmal carotid artery was misidentified with ultrasound by a junior resident, nearly leading to placement of a sheath into the artery. This case highlights arterial punctures that still occur even with ultrasound guidance. Further, training inadequacies as well as anatomic, cultural, and production pressure factors led to this potentially highly morbid near-miss. Physician teachers should critically evaluate teaching methods to confirm that trainees are learning skills as intended. (A&A Practice. 2023;17:e01661.).


Assuntos
Aneurisma , Cateterismo Venoso Central , Near Miss , Humanos , Cateterismo Venoso Central/efeitos adversos , Ultrassonografia , Artérias Carótidas/diagnóstico por imagem , Aneurisma/diagnóstico por imagem
7.
Proc (Bayl Univ Med Cent) ; 35(5): 703-704, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35991741

RESUMO

This is a case report of a 77-year-old man with severe symptomatic aortic stenosis who underwent removal of an impacted ureteral stone under general anesthesia. During emergence from general anesthesia, his legs were lowered from lithotomy position, resulting in sudden hypotension with progression to pulseless electrical activity. The legs were raised and placed into full flexion of the hips and knees. This maneuver was temporally related to a return of spontaneous circulation and full recovery. Possible mechanisms for this effect are discussed.

8.
Anesth Analg ; 132(5): 1191-1198, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33439605

RESUMO

BACKGROUND: Use of anesthesia machines as improvised intensive care unit (ICU) ventilators may occur in locations where waste anesthesia gas suction (WAGS) is unavailable. Anecdotal reports suggest as much as 18 cm H2O positive end-expiratory pressure (PEEP) being inadvertently applied under these circumstances, accompanied by inaccurate pressure readings by the anesthesia machine. We hypothesized that resistance within closed anesthesia gas scavenging systems (AGSS) disconnected from WAGS may inadvertently increase circuit pressures. METHODS: An anesthesia machine was connected to an anesthesia breathing circuit, a reference manometer, and a standard bag reservoir to simulate a lung. Ventilation was initiated as follows: volume control, tidal volume (TV) 500 mL, respiratory rate 12, ratio of inspiration to expiration times (I:E) 1:1.9, fraction of inspired oxygen (Fio2) 1.0, fresh gas flow (FGF) rate 2.0 liters per minute (LPM), and PEEP 0 cm H2O. After engaging the ventilator, PEEP and peak inspiratory pressure (PIP) were measured by the reference manometer and the anesthesia machine display simultaneously. The process was repeated using prescribed PEEP levels of 5, 10, 15, and 20 cm H2O. Measurements were repeated with the WAGS disconnected and then were performed again at FGF of 4, 6, 8, 10, and 15 LPM. This process was completed on 3 anesthesia machines: Dräger Perseus A500, Dräger Apollo, and the GE Avance CS2. Simple linear regression was used to assess differences. RESULTS: Utilizing nonparametric Bland-Altman analysis, the reference and machine manometer measurements of PIP demonstrated median differences of -0.40 cm H2O (95% limits of agreement [LOA], -1.00 to 0.55) for the Dräger Apollo, -0.40 cm H2O (95% LOA, -1.10 to 0.41) for the Dräger Perseus, and 1.70 cm H2O (95% LOA, 0.80-3.00) for the GE Avance CS2. At FGF 2 LPM and PEEP 0 cm H2O with the WAGS disconnected, the Dräger Apollo had a difference in PEEP of 0.02 cm H2O (95% confidence interval [CI], -0.04 to 0.08; P = .53); the Dräger Perseus A500, <0.0001 cm H2O (95% CI, -0.11 to 0.11; P = 1.00); and the GE Avance CS2, 8.62 cm H2O (95% CI, 8.55-8.69; P < .0001). After removing the hose connected to the AGSS and the visual indicator bag on the GE Avance CS2, the PEEP difference was 0.12 cm H2O (95% CI, 0.059-0.181; P = .0002). CONCLUSIONS: Displayed airway pressure measurements are clinically accurate in the setting of disconnected WAGS. The Dräger Perseus A500 and Apollo with open scavenging systems do not deliver inadvertent continuous positive airway pressure (CPAP) with WAGS disconnected, but the GE Avance CS2 with a closed AGSS does. This increase in airway pressure can be mitigated by the manufacturer's recommended alterations. Anesthesiologists should be aware of the potential clinically important increases in pressure that may be inadvertently delivered on some anesthesia machines, should the WAGS not be properly connected.


Assuntos
Anestesiologia/instrumentação , COVID-19/terapia , Unidades de Terapia Intensiva , Respiração com Pressão Positiva/instrumentação , Ventiladores Mecânicos , Anestesia/métodos , Anestesiologia/métodos , COVID-19/diagnóstico , COVID-19/epidemiologia , Cuidados Críticos/métodos , Humanos , Respiração com Pressão Positiva/métodos , Respiração Artificial/instrumentação , Respiração Artificial/métodos
9.
J Patient Saf ; 17(8): e1846-e1850, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32175957

RESUMO

OBJECTIVE: The aim of the study was to measure underdrape oxygen pooling, surgical site oxygen contamination, and time to restoration of 21% oxygen concentration after cessation of oxygen delivery by measuring oxygen concentration under simulated clinical conditions with various drapes. METHODS: In a 2-part study, oxygen permeability of four differing surgical drapes was measured (Part A) and a mannequin was used to measure underdrape oxygen pooling and surgical site oxygen contamination (Part B). In Part A, a container of high concentration oxygen was sealed with a surgical drape. Oxygen concentrations on both sides of the drape were then measured over time to quantify drape oxygen permeability. Part B included a mannequin model draped for a hypothetical surgical site with oxygen administered by face mask. Oxygen concentration was measured at both the surgical site and under the drape nearest the surgical site. RESULTS: Oxygen permeability varied significantly between drapes tested. The surgical site oxygen concentration ranged from 20% to 58% (P = 0.0001). The commonly used woven 100% cotton operating room (OR) towel was highly permeable. The plastic occlusive drape created an impermeable barrier, which did not allow for any oxygen contamination but created the longest time to return to 21% oxygen concentration at the underdrape site after cessation of oxygen delivery. CONCLUSIONS: Surgical drapes have varying oxygen permeability and can lead to high concentration underdrape oxygen pooling. Oxygen contamination of the surgical site varies widely based on drape material and may reach dangerously high levels, especially with the cotton OR towel. Surgical drape selection may impact OR fire risk.


Assuntos
Incêndios , Campos Cirúrgicos , Incêndios/prevenção & controle , Humanos , Salas Cirúrgicas , Oxigênio , Infecção da Ferida Cirúrgica/prevenção & controle
10.
Clin Neurol Neurosurg ; 200: 106371, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33307326

RESUMO

BACKGROUND AND PURPOSE: The Dawn and Extend Intra-Arterial (IA) acute stroke intervention trials have proven the benefit of thrombectomy in a select group of patients up to 24 h since their last known well time (LKWT) or time of symptom onset. Following the issuance of new treatment guidelines for large vessel occlusion strokes, we reviewed the paradigm shift effect on transfers for possible thrombectomy in a rural state. HYPOTHESIS: Extended time window for thrombectomy increases the need for better identification of potential transfers for thrombectomy in rural states with few hospitals capable of 24/7 interventional thrombectomy. METHODS: We analyzed all transfers to a comprehensive stroke center (CSC) from January to December 2018 which were specifically transferred for possible further intervention. This time period was selected in accordance with the change in American Heart Association (AHA) guidelines for extended time windows in mechanical thrombectomy (MT) care. RESULTS: A total of 132 patients were transferred for possible thrombectomy and advanced imaging. Thirty-four % patients underwent diagnostic angiogram with 33% patients having successful MT. Of the excluded patients 19% had large core infarcts by the time they arrived at hub hospital, 1.5% had hemorrhagic conversion, 32% had stroke without treatable occlusion not amenable for thrombectomy or cortical strokes on follow-up imaging, and 13.5% did not have stroke or LVO on follow-up imaging. CONCLUSION: Since the AHA's change in time window guidelines for mechanical thrombectomies, there has been an increased effort in identifying good candidates with computerized tomography angiography (CTA). To avoid undue burden on stroke systems of care, CTA identification of these patients at the spoke hospitals is key along with timely transport to appropriate thrombectomy capable sites. Given the rural nature of this state along with limited resources, selection of patients is a practical issue, especially for avoiding futile transfers, which might be true for large areas of the USA.


Assuntos
Isquemia Encefálica/cirurgia , Angiografia por Tomografia Computadorizada/tendências , Transferência de Pacientes/tendências , Acidente Vascular Cerebral/cirurgia , Trombectomia/tendências , Tempo para o Tratamento/tendências , Adulto , Idoso , Isquemia Encefálica/diagnóstico por imagem , Estudos de Coortes , Angiografia por Tomografia Computadorizada/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Transferência de Pacientes/métodos , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/métodos , Triagem/métodos , Triagem/tendências
11.
A A Pract ; 14(6): e01218, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32784318

RESUMO

Patient care duties will expose health care workers to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Many are concerned about subsequent household exposure to their families, particularly those family members with high risk of complications or mortality, potentiating additional community spread. Herein is described a temporary isolation room that can be created within a home, thereby decreasing bioburden exposure to family members. The design is simple, expedient, and can be built with locally sourced inexpensive supplies. A viewing and access window facilitates safe family interaction and decreases the emotional costs of isolation while providing a route to pass items as necessary.


Assuntos
Betacoronavirus , Infecções por Coronavirus/prevenção & controle , Pessoal de Saúde , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Quarentena/métodos , Arquitetura , COVID-19 , Habitação , Humanos , SARS-CoV-2
12.
Proc (Bayl Univ Med Cent) ; 33(1): 85-86, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32063782

RESUMO

Thromboembolectomy is often guided with fluoroscopy. For intracardiac and great vessel thromboemboli, transesophageal echocardiography (TEE) can assess these thrombi, guide precise suction catheter placement, prevent intracardiac injury, and serve as a hemodynamic monitor. TEE can also be used to assess blood flow and thrombotic material reduction following embolectomy. TEE is a low-risk, high-value, real-time imaging modality that facilitates thromboembolectomy and increases patient safety.

14.
Proc (Bayl Univ Med Cent) ; 32(4): 529-533, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31656411

RESUMO

Baylor Scott & White Health Central Texas displayed the diversity and growth of scholarly pursuits during Scholars Day on May 3, 2019. Residents and fellows, medical students, nurses, and research staff were among those showcasing their scholarly activity in areas such as medical innovation, clinical vignettes, research, and quality improvement. A selection committee chose 32 abstracts-12 select podium, 20 rapid fire. In addition, 60 abstracts were included as electronic poster presentations. Residency and fellowship program directors nominated presentations for the Excellence Awards. The scholarship committee chose four to receive travel awards to support the presentation of each project at a national meeting. Excellence Awards were granted to Jasson Abraham, MD, Jerry Fan, MD, Veronica Lozano, MD, and Chhaya Patel, MD. A selection of abstracts is presented here.

15.
J Vasc Interv Radiol ; 30(8): 1244-1250.e1, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31349978

RESUMO

PURPOSE: This randomized, placebo-controlled, double-blind, dose-escalation acute ischemic stroke trial was designed to demonstrate maximum tolerated dose, characterize adverse events (AEs), and explore clinical outcomes when intravenous dodecafluoropentane emulsion (DDFPe) was used as neuroprotection. METHODS: Acute ischemic stroke patients (n = 24) with National Institutes of Health Stroke Scale (NIHSS) score of 2-20 were randomized to either 3 doses of intravenous DDFPe or placebo, 1 every 90 minutes, starting within 12 hours of symptom onset. Doses were given without affecting standard stroke care. Each of the 3 dose cohorts included 8 patients, with 2 receiving placebo and 6 receiving DDFPe. Primary outcomes were serious adverse events (SAEs), AEs, NIHSS score, and modified Rankin Score (mRS). RESULTS: No dose-limiting toxicities were encountered, and no maximum tolerated dose was defined. One unrelated delayed death occurred in a DDFPe patient, and another occurred in the placebo group. Group SAEs and AEs were similar in incidence and severity. Early initiation of DDFPe treatment resulted in better NIHSS score response than late initiation (P = .03). Thirty- and 90-day mRS after high-dose therapy suggested clinical improvement (P = .01 and P = .03, respectively). However, the significance of differences in clinical outcomes was limited by small patient numbers and differences in stroke severity between cohorts. CONCLUSIONS: Intravenous DDFPe appears to be safe at all doses tested. Clinical improvements in NIHSS score and mRS were significant but compromised by small sample size.


Assuntos
Isquemia Encefálica/tratamento farmacológico , Fluorocarbonos/administração & dosagem , Fármacos Neuroprotetores/administração & dosagem , Acidente Vascular Cerebral/terapia , Administração Intravenosa , Arkansas , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Avaliação da Deficiência , Método Duplo-Cego , Esquema de Medicação , Feminino , Fluorocarbonos/efeitos adversos , Humanos , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Fármacos Neuroprotetores/efeitos adversos , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiothorac Vasc Anesth ; 33(1): 29-35, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30087025

RESUMO

OBJECTIVE: Describe the change in intraoperative transcatheter aortic valve replacement (TAVR) care by examining the utilization of transesophageal echocardiography (TEE) versus transthoracic echocardiography (TTE) and general anesthesia (GA) versus conscious sedation (CS) over time. DESIGN: Retrospective, observational. SETTING: A university, single, high-volume TAVR center. PARTICIPANTS: Patients who underwent TAVR. INTERVENTIONS: Retrospective data collection from the electronic medical records on TAVR patients at a single institution from March 1, 2014 to August 31, 2017. The intraoperative echocardiographic modality, anesthetic type, Society of Thoracic Surgeons (STS) operative mortality risk score, and date each new TAVR valve first was employed at the institution were recorded. MEASUREMENTS AND MAIN RESULTS: Data were analyzed using descriptive statistics apportioned into 6-month intervals. The Fisher exact test and chi-square test were used to test the association of anesthesia type and echocardiography over time, respectively. STS score, anesthetic type, and echocardiographic type were compared using the Wilcoxon rank sum test. Analysis showed increased use of TTE and CS, from 0% and 0% intially to 68.42% and 63.16% most recently (p < 0.0001). In the final study period (after March 1, 2017), the use of TTE and CS surpassed TEE and GA, respectively. STS scores were significantly higher among patients having TEE versus TTE (median STS 6.34 v 4.45, respectively [p = 0.0047]) and GA versus CS (median STS 6.36 v 4.37, respectively [p = 0.0090]). CONCLUSION: Although TAVR initially was conducted exclusively under GA with TEE, nearly two-thirds of TAVR procedures now are performed using CS and TTE at the authors' institution. STS scores were significantly lower in patients having CS and TTE.


Assuntos
Anestesia Geral/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana/métodos , Hospitais com Alto Volume de Atendimentos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
18.
Biomed Opt Express ; 9(11): 5667-5677, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30460154

RESUMO

Blood clotting is a serious clinical complication of many medical procedures and disorders including surgery, catheterization, transplantation, extracorporeal circuits, infections, and cancer. This complication leads to high patient morbidity and mortality due to clot-induced pulmonary embolism, stroke, and in some cases heart attack. Despite the clear medical significance, little progress has been made in developing the methods for detection of circulating blood clots (CBCs), also called emboli. We recently demonstrated the application of in vivo photoacoustic (PA) flow cytometry (PAFC) with unfocused ultrasound transducers for detection of CBCs in small vessels in a mouse model. In the current study, we extend applicability of PAFC for detection of CBCs in relatively large (1.5-2 mm) and deep (up to 5-6 mm) blood vessels in rat and rabbit models using a high pulse rate 1064 nm laser and focused ultrasound transducer with a central hole for an optic fiber. Employing phantoms and chemical activation of clotting, we demonstrated PA identification of white, red, and mixed CBCs producing negative, positive, and mixed PA contrast in blood background, respectively. We confirmed that PAFC can detect both red and white CBCs induced by microsurgical procedures, such as a needle or catheter insertion, as well as stroke modeled by injection of artificial clots. Our results show great potential for a PAFC diagnostic platform with a wearable PA fiber probe for diagnosis of thrombosis and embolism in vivo that is impossible with existing techniques.

20.
A A Case Rep ; 8(3): 64-66, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27941486

RESUMO

Amniotic fluid embolism (AFE) is a rare and often fatal complication that occurs in the peripartum period. We present a patient with an AFE who developed disseminated intravascular coagulation and cardiovascular collapse who may have benefitted from intravascular lipid emulsion rescue. This is the first published case in which lipid emulsion was a part of the successful treatment of AFE.


Assuntos
Embolia Amniótica/tratamento farmacológico , Lipídeos/uso terapêutico , Adulto , Embolia Amniótica/diagnóstico , Emulsões , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA