Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Sci Rep ; 13(1): 12983, 2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37563252

RESUMO

The World Health Organization's R&D Blueprint list of priority diseases for 2022 includes Lassa fever, signifying the need for research and development in emergency contexts. This disease is caused by the arenavirus Lassa virus (LASV). Being an enveloped virus, LASV should be susceptible to a variety of microbicidal actives, although empirical data to support this expectation are needed. We evaluated the virucidal efficacy of sodium hypochlorite, ethanol, a formulated dual quaternary ammonium compound, an accelerated hydrogen peroxide formulation, and a p-chloro-m-xylenol formulation, per ASTM E1052-20, against LASV engineered to express green fluorescent protein (GFP). A 10-µL volume of virus in tripartite soil (bovine serum albumin, tryptone, and mucin) was combined with 50 µL of disinfectant in suspension for 0.5, 1, 5, or 10 min at 20-25 °C. Neutralized test mixtures were quantified by GFP expression to determine log10 reduction. Remaining material was passaged on Vero cells to confirm absence of residual infectious virus. Input virus titers of 6.6-8.0 log10 per assay were completely inactivated by each disinfectant within 1-5 min contact time. The rapid and substantial inactivation of LASV suggests the utility of these microbicides for mitigating spread of infectious virus during Lassa fever outbreaks.


Assuntos
Anti-Infecciosos , Desinfetantes , Febre Lassa , Animais , Chlorocebus aethiops , Humanos , Vírus Lassa , Febre Lassa/prevenção & controle , Células Vero , Anti-Infecciosos/metabolismo , Desinfetantes/farmacologia , Desinfetantes/metabolismo , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo
2.
Front Microbiol ; 13: 847313, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35391722

RESUMO

High-touch environmental surfaces are acknowledged as potential sources of pathogen transmission, particularly in health care settings where infectious agents may be readily abundant. Methods of disinfecting these surfaces often include direct application of a chemical disinfectant or simply wiping the surface with a disinfectant pre-soaked wipe (DPW). In this study, we examine the ability of four disinfectants, ethanol (EtOH), sodium hypochlorite (NaOCl), chlorine dioxide (ClO2), and potassium monopersulfate (KMPS), to inactivate SARS-CoV-2 on a hard, non-porous surface, assessing the effects of concentration and contact time. The efficacy of DPWs to decontaminate carriers spiked with SARS-CoV-2, as well as the transferability of the virus from used DPWs to clean surfaces, is also assessed. Stainless steel carriers inoculated with approximately 6 logs of SARS-CoV-2 prepared in a soil load were disinfected within 5 min through exposure to 66.5% EtOH, 0.5% NaOCl, and 1% KMPS. The addition of mechanical wiping using DPWs impregnated with these biocides rendered the virus inactive almost immediately, with no viral transfer from the used DPW to adjacent surfaces. Carriers treated with 100 ppm of ClO2 showed a significant amount of viable virus remaining after 10 min of biocide exposure, while the virus was only completely inactivated after 10 min of treatment with 500 ppm of ClO2. Wiping SARS-CoV-2-spiked carriers with DPWs containing either concentration of ClO2 for 5 s left significant amounts of viable virus on the carriers. Furthermore, higher titers of infectious virus retained on the ClO2-infused DPWs were transferred to uninoculated carriers immediately after wiping. Overall, 66.5% EtOH, 0.5% NaOCl, and 1% KMPS appear to be highly effective biocidal agents against SARS-CoV-2, while ClO2 formulations are much less efficacious.

3.
PLoS One ; 16(9): e0258151, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34591919

RESUMO

BACKGROUND: Few studies have quantified aerosol concentrations of SARS-CoV-2 in hospitals and long-term care homes, and fewer still have examined samples for viability. This information is needed to clarify transmission risks beyond close contact. METHODS: We deployed particulate air samplers in rooms with COVID-19 positive patients in hospital ward and ICU rooms, rooms in long-term care homes experiencing outbreaks, and a correctional facility experiencing an outbreak. Samplers were placed between 2 and 3 meters from the patient. Aerosol (small liquid particles suspended in air) samples were collected onto gelatin filters by Ultrasonic Personal Air Samplers (UPAS) fitted with <2.5µm (micrometer) and <10 µm size-selective inlets operated for 16 hours (total 1.92m3), and with a Coriolis Biosampler over 10 minutes (total 1.5m3). Samples were assayed for viable SARS-CoV-2 virus and for the viral genome by multiplex PCR using the E and N protein target sequences. We validated the sampling methods by inoculating gelatin filters with viable vesicular stomatitis virus (VSV), and with three concentrations of viable SARS-CoV-2, operating personal samplers for 16hrs, and quantifying viable virus recovery by TCID50 assay. RESULTS: In total, 138 samples were collected from 99 rooms. RNA samples were positive in 9.1% (6/66) of samples obtained with the UPAS 2.5µm samplers, 13.5% (7/52) with the UPAS 10µm samplers, and 10.0% (2/20) samples obtained with the Coriolis samplers. Culturable virus was not recovered in any samples. Viral RNA was detected in 15.1% of the rooms sampled. There was no significant difference in viral RNA recovery between the different room locations or samplers. Method development experiments indicated minimal loss of SARS-CoV-2 viability via the personal air sampler operation.


Assuntos
Aerossóis/isolamento & purificação , Microbiologia do Ar , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , Animais , COVID-19/epidemiologia , COVID-19/transmissão , Chlorocebus aethiops , Hospitais , Humanos , Assistência de Longa Duração , RNA Viral/isolamento & purificação , Células Vero
4.
Sci Rep ; 11(1): 18316, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34526550

RESUMO

Shortages of personal protective equipment for use during the SARS-CoV-2 pandemic continue to be an issue among health-care workers globally. Extended and repeated use of N95 filtering facepiece respirators without adequate decontamination is of particular concern. Although several methods to decontaminate and re-use these masks have been proposed, logistic or practical issues limit adoption of these techniques. In this study, we propose and validate the use of the application of moist heat (70 °C with humidity augmented by an open pan of water) applied by commonly available hospital (blanket) warming cabinets to decontaminate N95 masks. This report shows that a variety of N95 masks can be repeatedly decontaminated of SARS-CoV-2 over 6 h moist heat exposure without compromise of their filtering function as assessed by standard fit and sodium chloride aerosol filtration efficiency testing. This approached can easily adapted to provide point-of-care N95 mask decontamination allowing for increased practical utility of mask recycling in the health care setting.


Assuntos
Descontaminação/métodos , Respiradores N95/virologia , SARS-CoV-2/fisiologia , Reutilização de Equipamento , Hospitais , Humanos , Umidade , Sistemas Automatizados de Assistência Junto ao Leito , Fatores de Tempo , Inativação de Vírus
5.
Front Public Health ; 9: 657443, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34447735

RESUMO

The authors evaluated four disinfectant pre-impregnated wipes (DPW) for efficacy against Ebola virus Makona variant (EBOV) and vesicular stomatitis virus (VSV), Indiana serotype. Steel carriers were inoculated with the infectious virus and then were wiped with DPW in the Wiperator instrument per ASTM E2967-15. Following the use of J-Cloth impregnated with medium (negative control wipes) or the use of activated hydrogen peroxide (AHP)-, ethanol-, sodium hypochlorite (NaOCl)-, or single or dual quaternary ammonium compound (QAC)-based DPW, virus recovery from the carriers was assayed by titration assay and by two passages on Vero E6 cells in 6-well plates. The Wiperator also enabled the measurement of potential transfer of the virus from the inoculated carrier to a secondary carrier by the DPW or control wipes. The J-Cloth wipes wetted with medium alone (no microbicidal active) removed 1.9-3.5 log10 of virus from inoculated carriers but transferred ~4 log10 of the wiped virus to secondary carriers. DPW containing AHP, ethanol, NaOCl, or single or dual QAC as active microbicidal ingredients removed/inactivated ~6 log10 of the virus, with minimal EBOV or no VSV virus transfer to a secondary surface observed. In Ebola virus outbreaks, a DPW with demonstrated virucidal efficacy, used as directed, may help to mitigate the unintended spread of the infectious virus while performing surface cleaning.


Assuntos
Desinfetantes , Ebolavirus , Doença pelo Vírus Ebola , Estomatite Vesicular , Animais , Desinfetantes/farmacologia , Doença pelo Vírus Ebola/prevenção & controle , Aço Inoxidável
6.
PLoS One ; 16(6): e0253068, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34111204

RESUMO

The novel coronavirus, SARS-CoV-2, has spread into a pandemic since its emergence in Wuhan, China in December of 2019. This has been facilitated by its high transmissibility within the human population and its ability to remain viable on inanimate surfaces for an extended period. To address the latter, we examined the effect of simulated sunlight on the viability of SARS-CoV-2 spiked into tissue culture medium or mucus. The study revealed that inactivation took 37 minutes in medium and 107 minutes in mucus. These times-to-inactivation were unexpected since they are longer than have been observed in other studies. From this work, we demonstrate that sunlight represents an effective decontamination method but the speed of decontamination is variable based on the underlying matrix. This information has an important impact on the development of infection prevention and control protocols to reduce the spread of this deadly pathogen.


Assuntos
COVID-19/virologia , Descontaminação/métodos , Muco/virologia , SARS-CoV-2/efeitos da radiação , Luz Solar , Inativação de Vírus/efeitos da radiação , Humanos , Viabilidade Microbiana/efeitos da radiação , SARS-CoV-2/fisiologia
9.
Sci Rep ; 11(1): 984, 2021 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-33441775

RESUMO

The spread of COVID-19 in healthcare settings is concerning, with healthcare workers representing a disproportionately high percentage of confirmed cases. Although SARS-CoV-2 virus has been found to persist on surfaces for a number of days, the extent and duration of fomites as a mode of transmission, particularly in healthcare settings, has not been fully characterized. To shed light on this critical matter, the present study provides the first comprehensive assessment of SARS-CoV-2 stability on experimentally contaminated personal protective equipment (PPE) widely used by healthcare workers and the general public. Persistence of viable virus was monitored over 21 days on eight different materials, including nitrile medical examination gloves, reinforced chemical resistant gloves, N-95 and N-100 particulate respirator masks, Tyvek, plastic, cotton, and stainless steel. Unlike previous reports, viable SARS-CoV-2 in the presence of a soil load persisted for up to 21 days on experimentally inoculated PPE, including materials from filtering facepiece respirators (N-95 and N-100 masks) and a plastic visor. Conversely, when applied to 100% cotton fabric, the virus underwent rapid degradation and became undetectable by TCID50 assay within 24 h. These findings underline the importance of appropriate handling of contaminated PPE during and following use in high-risk settings and provide interesting insight into the potential utility of cotton in limiting COVID-19 transmission.


Assuntos
Equipamento de Proteção Individual , SARS-CoV-2/fisiologia , Porosidade , RNA Viral/genética , SARS-CoV-2/genética , Propriedades de Superfície
10.
Appl Biosaf ; 26(2): 66-70, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36034692

RESUMO

Introduction: Positive pressure breathing air-fed protective suits from three vendors are commonly used in biosafety level 4 (BSL-4) laboratories: they are Dover Chemturion suits (ILC Dover, DE), Delta suits (Honeywell Safety, NC), and HVO suits (HVO-ISSI-Deutschland GmbH, Germany). To address the potential risk of infectious agents being introduced through the supplied breathing air stream, some suit manufacturers incorporate protective filters on the suits themselves. However, these integrated filters are not amenable to in situ testing for efficacy verification. We have been using external filters from Matheson USA on the positive pressure suits since our BSL-4 laboratories were commissioned two decades ago. As part of our BSL-4 protective suit management program, we test these filters before them being put into use, and annually thereafter. In the past few years, we have observed these filters failing at a higher rate, as high as two out of three of the new filters tested at one point. Objective: The purpose of this study was to procure personal protective filters from other sources and validate their efficacy long-term. Methods: Filters from Respirex, HVO, and Honeywell were validated for filter integrity and filter loading. Results: Respirex filters performed well during the initial testing and periodic testing thereafter. Regular testing of the Respirex filters has now been ongoing for 30 months with continued successful performance. Conclusion: Filters from Respirex are a suitable option to protect personnel wearing positive pressure suits in BSL-4 laboratories.

11.
PLoS One ; 15(12): e0243965, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33326504

RESUMO

The response to the COVID-19 epidemic is generating severe shortages of personal protective equipment around the world. In particular, the supply of N95 respirator masks has become severely depleted, with supplies having to be rationed and health care workers having to use masks for prolonged periods in many countries. We sought to test the ability of 7 different decontamination methods: autoclave treatment, ethylene oxide gassing (ETO), low temperature hydrogen peroxide gas plasma (LT-HPGP) treatment, vaporous hydrogen peroxide (VHP) exposure, peracetic acid dry fogging (PAF), ultraviolet C irradiation (UVCI) and moist heat (MH) treatment to decontaminate a variety of different N95 masks following experimental contamination with SARS-CoV-2 or vesicular stomatitis virus as a surrogate. In addition, we sought to determine whether masks would tolerate repeated cycles of decontamination while maintaining structural and functional integrity. All methods except for UVCI were effective in total elimination of viable virus from treated masks. We found that all respirator masks tolerated at least one cycle of all treatment modalities without structural or functional deterioration as assessed by fit testing; filtration efficiency testing results were mostly similar except that a single cycle of LT-HPGP was associated with failures in 3 of 6 masks assessed. VHP, PAF, UVCI, and MH were associated with preserved mask integrity to a minimum of 10 cycles by both fit and filtration testing. A similar result was shown with ethylene oxide gassing to the maximum 3 cycles tested. Pleated, layered non-woven fabric N95 masks retained integrity in fit testing for at least 10 cycles of autoclaving but the molded N95 masks failed after 1 cycle; filtration testing however was intact to 5 cycles for all masks. The successful application of autoclaving for layered, pleated masks may be of particular use to institutions globally due to the virtually universal accessibility of autoclaves in health care settings. Given the ability to modify widely available heating cabinets on hospital wards in well-resourced settings, the application of moist heat may allow local processing of N95 masks.


Assuntos
Descontaminação/métodos , Reutilização de Equipamento , Respiradores N95/virologia , COVID-19/patologia , COVID-19/virologia , Óxido de Etileno/farmacologia , Humanos , Peróxido de Hidrogênio/farmacologia , Ácido Peracético/farmacologia , Gases em Plasma/farmacologia , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta , Vesiculovirus/efeitos dos fármacos , Vesiculovirus/efeitos da radiação
12.
Sci Rep ; 10(1): 15247, 2020 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943689

RESUMO

Microbicides play critical roles in infection prevention and control of Ebola virus by decontaminating high-touch environmental surfaces (HITES), interrupting the virus-HITES-hands nexus. We evaluated the efficacy of formulations containing different microbicidal actives for inactivating Ebola virus-Makona strain (EBOV/Mak) on stainless-steel carriers per ASTM E2197-11. Formulations of sodium hypochlorite (NaOCl) (0.05-1%), ethanol (70%), chloroxylenol (PCMX) (0.12-0.48% by weight) in hard water, and a ready-to-use disinfectant spray with 58% ethanol (EDS), were tested at contact times of 0, or 0.5 to 10 min at ambient temperature. EBOV/Mak was inactivated (> 6 log10) by 70% ethanol after contact times ≥ 2.5 min, by 0.5% and 1% NaOCl or EDS (> 4 log10) at contact times ≥ 5 min, and by 0.12-0.48% PCMX (> 4.2 log10) at contact times ≥ 5 min. Residual infectious virus in neutralized samples was assessed by passage on cells and evaluation for viral cytopathic effect. No infectious virus was detected in cells inoculated with EBOV/Mak exposed to NaOCl (0.5% or 1%), PCMX (0.12% to 0.48%), or EDS for ≥ 5 min. These results demonstrate ≥ 6 log10 inactivation of EBOV/Mak dried on prototypic surfaces by EDS or formulations of NaOCl (≥ 0.5%), PCMX (≥ 0.12%), or 70% ethanol at contact times ≥ 5 min.


Assuntos
Anti-Infecciosos/farmacologia , Ebolavirus/efeitos dos fármacos , Doença pelo Vírus Ebola/prevenção & controle , Inativação de Vírus/efeitos dos fármacos , Animais , Chlorocebus aethiops , Efeito Citopatogênico Viral/efeitos dos fármacos , Desinfetantes/farmacologia , Ebolavirus/patogenicidade , Microbiologia Ambiental , Etanol/farmacologia , Doença pelo Vírus Ebola/transmissão , Doença pelo Vírus Ebola/virologia , Humanos , Técnicas In Vitro , Porosidade , Hipoclorito de Sódio/farmacologia , Propriedades de Superfície , Células Vero , Xilenos/farmacologia
13.
Front Public Health ; 8: 183, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32582604

RESUMO

Disinfectant pre-soaked wipes (DPW) containing activated hydrogen peroxide (AHP) or quaternary ammonium compounds (QAC) were tested using ASTM E2967-15 to determine removal, transfer, and inactivation of Ebola virus Makona variant (EBOV/Mak) and vesicular stomatitis virus (VSV) from contaminated stainless steel prototypic environmental surfaces. The infectious virus-contaminated carriers were subjected to wiping in the Wiperator per the standard. Following the use of negative control (J-Cloth)-, AHP-, or QAC-based wipes, recovery of residual infectious virus was assayed. In the case of the J-Cloth wipes (negative control), although removal of virus from inoculated carriers was extensive i.e., ~99% (1.9-3.5 log10) transfer of virus by these wipes to a secondary surface amounted to ≤ 2% (~3.8 log10) of the initial virus load. In the case of each DPW, >6 log10 removal/inactivation of virus was observed, with limited (EBOV/Mak) or no (VSV) virus transfer observed. The efficacy of wipes for decontaminating high-touch environmental surfaces spiked with EBOV/Mak or VSV is discussed. In summary, removal of EBOV/Mak and VSV using wipes was extensive in this study. In the absence of a sufficient concentration and contact time of an appropriate microbicidal active in DPW (such as the AHP- and QAC-based DPW tested), transfer of a low, albeit significant (from an infectious unit/infectious dose perspective), quantity of infectious virus from the inoculated surface to a secondary surface was observed. In the case of Ebola virus, it is essential that a DPW with an appropriate microbicidal active, following the appropriate contact time, be used to prevent unintended transfer of infectious virus to a clean secondary surface (as observed in negative control /J-Cloth). Otherwise, there exists the possibility of dissemination of Ebola virus and the associated risk of transmission of Ebola virus disease.


Assuntos
Desinfetantes , Ebolavirus , Doença pelo Vírus Ebola , Estomatite Vesicular , Animais , Doença pelo Vírus Ebola/prevenção & controle , Vesiculovirus
15.
Intensive Care Med Exp ; 7(1): 54, 2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31520194

RESUMO

BACKGROUND: There are currently limited data for the use of specific antiviral therapies for the treatment of Ebola virus disease (EVD). While there is anecdotal evidence that supportive care may be effective, there is a paucity of direct experimental data to demonstrate a role for supportive care in EVD. We studied the impact of ICU-level supportive care interventions including fluid resuscitation, vasoactive medications, blood transfusion, hydrocortisone, and ventilator support on the pathophysiology of EVD in rhesus macaques infected with a universally lethal dose of Ebola virus strain Makona C07. METHODS: Four NHPs were infected with a universally lethal dose Ebola virus strain Makona, in accordance with the gold standard lethal Ebola NHP challenge model. Following infection, the following therapeutic interventions were employed: continuous bedside supportive care, ventilator support, judicious fluid resuscitation, vasoactive medications, blood transfusion, and hydrocortisone as needed to treat cardiovascular compromise. A range of physiological parameters were continuously monitored to gage any response to the interventions. RESULTS: All four NHPs developed EVD and demonstrated a similar clinical course. All animals reached a terminal endpoint, which occurred at an average time of 166.5 ± 14.8 h post-infection. Fluid administration may have temporarily blunted a rise in lactate, but the effect was short lived. Vasoactive medications resulted in short-lived improvements in mean arterial pressure. Blood transfusion and hydrocortisone did not appear to have a significant positive impact on the course of the disease. CONCLUSIONS: The model employed for this study is reflective of an intramuscular infection in humans (e.g., needle stick) and is highly lethal to NHPs. Using this model, we found that the animals developed progressive severe organ dysfunction and profound shock preceding death. While the overall impact of supportive care on the observed pathophysiology was limited, we did observe some time-dependent positive responses. Since this model is highly lethal, it does not reflect the full spectrum of human EVD. Our findings support the need for continued development of animal models that replicate the spectrum of human disease as well as ongoing development of anti-Ebola therapies to complement supportive care.

16.
Sci Rep ; 9(1): 6590, 2019 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-31036865

RESUMO

The efficacy of Dettol Antiseptic Liquid (DAL) for inactivating Ebola virus (Makona C07 variant) (EBOV/Mak) within an organic load in suspension was evaluated per ASTM E1052-11. Three DAL lots were evaluated at dilutions of 1:10, 1:20, and 1:40, with contact times of 0.5, 1, 5, and 10 min. Approximately 7 log10 tissue culture infectious dose50 (TCID50) of EBOV/Mak was exposed to DAL at ambient temperature. Each dilution tested reduced the infectious EBOV/Mak titer by ~5 log10 within one min. Detectable virus was still present after an 0.5-min exposure, but each DAL dilution caused >4 log10 reduction within this time. Detection of virus below the limit of detection of the TCID50 assay was assessed by inoculating flasks of Vero E6 cells with undiluted neutralized sample and evaluating the cultures for cytopathic effect after 14 days incubation. No infectious virus was detected with this non-quantitative method in samples subjected to DAL for 5 or 10 min, regardless of the dilution evaluated. The rapid and substantial inactivation of EBOV/Mak by DAL suggests that use of this hygiene product could help prevent the spread of Ebola virus disease during outbreaks.


Assuntos
Ebolavirus/efeitos dos fármacos , Doença pelo Vírus Ebola/prevenção & controle , Suspensões/farmacologia , Xilenos/farmacologia , Animais , Anti-Infecciosos Locais/farmacologia , Chlorocebus aethiops , Doença pelo Vírus Ebola/virologia , Humanos , Células Vero , Inativação de Vírus/efeitos dos fármacos
17.
Front Public Health ; 7: 23, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30847337

RESUMO

The transmission of infectious microbes via bioaerosols is of significant concern for both human and animal health. However, gaps in our understanding of respiratory pathogen transmission and methodological heterogeneity persist. New developments have enabled progress in this domain, and one of the major turning points has been the recognition that cross-disciplinary collaborations across spheres of human and animal health, microbiology, biophysics, engineering, aerobiology, infection control, public health, occupational health, and industrial hygiene are essential. Collaborative initiatives support advances in topics such as bioaerosol behavior, dispersion models, risk assessment, risk/exposure effects, and mitigation strategies in clinical, experimental, agricultural, and other field settings. There is a need to enhance the knowledge translation for researchers, stakeholders, and private partners to support a growing network of individuals and agencies to achieve common goals to mitigate inter- and intra-species pathogen transmission via bioaerosols.

18.
Sci Rep ; 7(1): 4388, 2017 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-28663587

RESUMO

After the largest Ebola virus outbreak in history, experts have attempted to answer how the Zaire ebolavirus species emerged in West Africa and caused chains of human-to-human transmission. The widespread and untimely infection of Health Care Workers (HCW) in the affected countries accelerated spread of the virus within the community. Among the reasons attributed to this trend, it must be considered that HCW were exposed to the virus in their occupational environment. The contribution of environmental conditions to the spread of Ebola in West Africa was examined by investigating the effect of temperature/humidity on the virus's environmental persistence and by modeling if saturation (liquid stress) allows for penetration of Ebola virus through personal protective equipment (PPE). Ebola-Makona virus persisted on PPE and materials found in outbreak settings for less than 72 hours at 27 °C and 80% relative humidity (RH). A difference in virus penetration was observed between dry (5%, 1/21 tests) and saturated (33%, 7/21 tests) samples of PPE. Infectious virus particles penetrated through saturated coupons of Tyvek Micro Clean, Tychem QC, whole surgical masks and N95 respirators. These findings suggest inclusion of saturation or similar liquid stress simulation in protective equipment testing standards.


Assuntos
Ebolavirus/fisiologia , Meio Ambiente , Doença pelo Vírus Ebola/transmissão , Doença pelo Vírus Ebola/virologia , Equipamento de Proteção Individual , África Ocidental , Clima , Surtos de Doenças , Humanos
19.
Sci Rep ; 7(1): 3390, 2017 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-28611428

RESUMO

Marburg virus (MARV) has caused outbreaks of filoviral hemorrhagic fever since its discovery in 1967. The largest and deadliest outbreak occurred in Angola in 2005, with 252 cases and 227 deaths. In 2014, we developed a mouse-adapted MARV, Angola variant through serial passaging in mice. The mouse-adapted MARV exhibits many of the hallmarks of MARV disease in humans. By applying deep-sequencing to every passage of the virus, we are able to study virus evolution in this host with surprising precision. We show that two regions go through substantial changes: the intergenic region between NP and VP35, as well as the first 100 amino acids of the VP40 protein. Our results also reveal that there were profound changes during the production of the final virus stock in cell culture. Overall, our results show that a handful of regions carry most of the mutations acquired during the adaptation of the virus to a new host and that many mutations become fixed very early during the adaptation process.


Assuntos
Adaptação Biológica/genética , Genoma Viral , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Doença do Vírus de Marburg/patologia , Doença do Vírus de Marburg/virologia , Marburgvirus/genética , Proteínas Virais/genética , Animais , Células Cultivadas , Doença do Vírus de Marburg/genética , Marburgvirus/crescimento & desenvolvimento , Marburgvirus/isolamento & purificação , Camundongos , RNA Viral/genética , Inoculações Seriadas , Carga Viral
20.
Sci Rep ; 6: 38293, 2016 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-27910909

RESUMO

The recent Ebola virus outbreak in West Africa has forced experts to re-evaluate their understanding of how to best disinfect areas contaminated with infectious bodily fluids. Recent research has found that Ebola virus remains viable in blood for 7-10 days making appropriate disinfection crucial to infection control. We sought to determine if the three most important outbreak variants of Zaire ebolavirus (Mayinga, Kikwit and Makona) exhibit separate phenotypes when challenged with a range of sodium hypochlorite (NaOCl) concentrations or 70% ethanol (EtOH) at average West African temperature. The time dependent killing of Ebola virus was evaluated by measuring infectious virus and viral RNA (vRNA), to determine if RNA detection is a viable method for decontamination measurement in areas without high containment laboratory access. Makona was less susceptible to weaker concentrations of NaOCl (0.05 and 0.1%) than Mayinga and Kikwit. At the recommended concentration of NaOCl (≥0.5%) all of the variants were inert after 5 minutes of contact time. Similarly, all variants were inactivated by 70% EtOH after 2.5 minutes, only Makona was detected at 1 minute. In multiple instances, high amounts of vRNA was detected in the absence of infectious virus, suggesting that it does not serve as an accurate measure of remaining infectivity after cleansing.


Assuntos
Surtos de Doenças , Desinfetantes/farmacologia , Ebolavirus/efeitos dos fármacos , Etanol/farmacologia , Doença pelo Vírus Ebola/epidemiologia , Hipoclorito de Sódio/farmacologia , África Ocidental/epidemiologia , Desinfecção/métodos , Ebolavirus/genética , Ebolavirus/crescimento & desenvolvimento , Doença pelo Vírus Ebola/transmissão , Doença pelo Vírus Ebola/virologia , Humanos , Testes de Sensibilidade Microbiana , RNA Viral/antagonistas & inibidores , RNA Viral/biossíntese , RNA Viral/genética , Vírion/efeitos dos fármacos , Vírion/genética , Vírion/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA