1.
Materials (Basel) ; 17(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38612141

RESUMO

Fiber-reinforced cementitious matrix (FRCM) composites have been largely used to strengthen existing concrete and masonry structures in the last decade. To design FRCM-strengthened members, the provisions of the Italian CNR-DT 215 (2018) or the American ACI 549.4R and 6R (2020) guidelines can be adopted. According to the former, the FRCM effective strain, i.e., the composite strain associated with the loss of composite action, can be obtained by combining the results of direct shear tests on FRCM-substrate joints and of tensile tests on the bare reinforcing textile. According to the latter, the effective strain can be obtained by testing FRCM coupons in tension, using the so-called clevis-grip test set-up. However, the complex bond behavior of the FRCM cannot be fully captured by considering only the effective strain. Thus, a cohesive approach has been used to describe the stress transfer between the composite and the substrate and cohesive material laws (CMLs) with different shapes have been proposed. The determination of the CML associated with a specific FRCM-substrate joint is fundamental to capture the behavior of the FRCM-strengthened member and should be determined based on the results of experimental bond tests. In this paper, a procedure previously proposed by the authors to calibrate the CML from the load response obtained by direct shear tests of FRCM-substrate joints is applied to different FRCM composites. Namely, carbon, AR glass, and PBO FRCMs are considered. The results obtained prove that the procedure allows to estimate the CML and to associate the idealized load response of a specific type of FRCM to the corresponding CML. The estimated CML can be used to determine the onset of debonding in FRCM-substrate joints, the crack number and spacing in FRCM coupons, and the locations where debonding occurs in FRCM-strengthened members.

2.
Materials (Basel) ; 15(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36079365

RESUMO

This study presents three-point bending fracture tests on glass fiber-reinforced polymer (GFRP) reinforced concrete notched beams. Few studies have been conducted to date to understand the fracture behavior of this type of specimens. The specimens have nominal depth, width, and length equal to 150 mm, 150 mm, and 550 mm. Plain concrete notched beams with the same dimensions are cast from the same batch of concrete to compare the responses with GFRP reinforced concrete notched beams. The notch of the plain concrete specimens is either saw cut or cast. These two notch fabrication methods are compared based on the load responses. The peak load, crack mouth opening displacement (CMOD), GFRP bar slip at two ends, and load point displacement are used to discuss the results of the fracture tests. In addition, digital image analysis is performed to identify the fracture process zone (FPZ) and the location of the neutral axis, which are used to determine the force in the GFRP bar via cross-sectional analysis. Finally, the GFRP bar force versus slip responses are compared with those from the pull-out tests performed on the same bar to show that the bond of the bar in the pull-out tests represents an upper bound limit compared to the behavior in bending.

3.
Materials (Basel) ; 15(9)2022 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-35591615

RESUMO

Fabric-reinforced cementitious matrix (FRCM) composites, comprising high-strength fiber textiles embedded within inorganic matrices, represent an effective, cost-efficient, and low-invasive solution for strengthening and retrofitting existing masonry and reinforced concrete structures. Among different textiles employed in FRCM composites, polyparaphenylene benzo-bisoxazole (PBO) textiles are adopted due to their high tensile strength and good adhesion with the matrix. Although several experimental, numerical, and analytical works were performed to investigate the mechanical properties of PBO FRCM composites, limited information is available on their long-term behavior, as well as in the case of exposure to aggressive environments. This paper presents and discusses the results of a wide experimental campaign aimed at investigating the effect of different environmental conditions on the long-term tensile behavior of a PBO FRCM composite. Tests are performed using a clamping-grip tensile test set-up. The effect of various aggressive environments on the composite matrix cracking stress, composite tensile strength, ultimate strain, and fully cracked stage slope is investigated by comparing the results of nominally equal conditioned and unconditioned (control) specimens. These results are also compared with those of other FRCM composites comprising glass and carbon textiles subjected to the same conditionings, collected from the literature. The results show only limited reductions in the tensile properties, even after long exposure to aggressive environments.

4.
Materials (Basel) ; 14(24)2021 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-34947224

RESUMO

Limited deflection of structural members represents an important requirement to guarantee proper functionality and appearance of building and infrastructures. According to Eurocodes, this requirement is ensured by limiting the maximum deflection of horizontal structural members to a fraction of their span. However, each Eurocode provides different maximum deflection limits, which are independent of the type of superstructures considered. Thus, the respect of these limits may not always guarantee the integrity of certain superstructures. In this paper, the reliability of the Eurocode deflection control methods, in guaranteeing the integrity of the superstructures, is assessed and discussed. First, different types of horizontal member, namely rib and clay (hollow) pot, composite steel-concrete, and timber beam slabs are designed to respect the deflection limit enforced by the Eurocodes. Then, the maximum curvature developed by these members is compared with the ultimate (limit) curvatures of various superstructures (e.g., ceramic and stone tile floorings). The results obtained show that the approach adopted by Eurocode 2 may provide non-conservative results, but also that the rules proposed by Eurocodes 4 and 5, albeit more reliable, do not always guarantee the integrity of the superstructure. Based on these results, an alternative method, based on the curvature control, is proposed and its advantages and limitations critically discussed. This method appears simpler and more reliable than the method currently adopted by the Eurocodes.

5.
Materials (Basel) ; 14(23)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34885284

RESUMO

Rehabilitation, strengthening, and retrofitting of existing masonry buildings represent an important challenge for the construction engineering field. Often, slab strengthening/retrofitting is performed by replacing existing timber and steel beams or by adding new beams to improve the slab load-carrying capacity. The computation of the stresses at the beam-masonry interface (i.e., the contact pressure) is crucial to properly design the beam support length, preventing local failure of masonry and beam. This paper presents a simple analytical procedure to compute the contact pressure at the beam-masonry interface. The analytical procedure is validated by comparison between analytical and corresponding numerical results obtained by finite element modeling. Different types of beam (solid and laminated timber beams and steel beams) were considered, as well as different support conditions (simply resting on the wall considering different support lengths or fully embedded). The results obtained show that the method proposed is simple and reliable, which makes it suitable for professional practice.

6.
Materials (Basel) ; 14(20)2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34683763

RESUMO

In recent years, inorganic-matrix reinforcement systems, such as fiber-reinforced cementitious matrix (FRCM), composite-reinforced mortars (CRM), and steel-reinforced grout (SRG), have been increasingly used to retrofit and strengthen existing masonry and concrete structures. Despite their good short-term properties, limited information is available on their long-term behavior. In this paper, the long-term bond behavior of some FRCM, CRM, and SRG systems bonded to masonry substrates is investigated. Namely, the results of single-lap direct shear tests of FRCM-, CRM-, and SRG-masonry joints subjected to wet-dry cycles are provided and discussed. First, FRCM composites comprising carbon, polyparaphenylene benzobisoxazole (PBO), and alkali-resistant (AR) glass textiles embedded within cement-based matrices, are considered. Then, CRM and SRG systems made of an AR glass composite grid embedded with natural hydraulic lime (NHL) and of unidirectional steel cords embedded within the same lime matrix, respectively, are studied. For each type of composite, six specimens are exposed to 50 wet-dry cycles prior to testing. The results are compared with those of nominally equal unconditioned specimens previously tested by the authors. This comparison shows a shifting of the failure mode for some composites from debonding at the matrix-fiber interface to debonding at the matrix-substrate interface. Furthermore, the average peak stress of all systems decreases except for the carbon FRCM and the CRM, for which it remains unaltered or increases.

7.
Materials (Basel) ; 14(18)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34576636

RESUMO

This paper describes methods, procedures, and results of cyclic loading tensile tests of a PBO FRCM composite. The main objective of the research is the evaluation of the effect of low- and high-cycle fatigue on the composite tensile properties, namely the tensile strength, ultimate tensile strain, and slope of the stress-strain curve. To this end, low- and high-cycle fatigue tests and post-fatigue tests were performed to study the composite behavior when subjected to cyclic loading and after being subjected to a different number of cycles. The results showed that the mean stress and amplitude of fatigue cycles affect the specimen behavior and mode of failure. In high-cycle fatigue tests, failure occurred due to progressive fiber filaments rupture. In low-cycle fatigue, the stress-strain response and failure mode were similar to those observed in quasi-static tensile tests. The results obtained provide important information on the fatigue behavior of PBO FRCM coupons, showing the need for further studies to better understand the behavior of existing concrete and masonry members strengthened with FRCM composites and subjected to cyclic loading.

8.
Materials (Basel) ; 13(10)2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32455652

RESUMO

Several reinforced-concrete (RC) structural elements are subjected to cyclic load, such those employed in highway and railroad bridges and viaducts. The durability of these elements may be reduced as a consequence of fatigue, which mainly affects the steel reinforcement. The use of externally bonded (EB) fiber-reinforced cementitious matrix (FRCM) composites allows the moment capacity to be shared by the internal reinforcement and the EB composite, thus increasing the fatigue life of the strengthened RC member. The effectiveness of EB FRCM composites is related to the composite bond properties. However, limited research is currently available on the effect of fatigue on the bond behavior of FRCM-substrate joints. This study provides first the state of the art on the fatigue behavior of different FRCM composites bonded to a concrete substrate. Then, the fatigue bond behavior of a polyparaphenylene benzo-bisoxazole (PBO) FRCM is experimentally investigated using a modified beam test set-up. The use of this set-up provided information on the effect of fiber-matrix interface shear and normal stresses on the specimen fatigue bond behavior. The results showed that fatigue loading may induce premature debonding at the matrix-fiber interface and that stresses normal to the interface reduce the specimen fatigue life.