Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
8.
Transfusion ; 37(5): 523-7, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9149779

RESUMO

BACKGROUND: Although certain transfusion risks are eliminated by the use of autologous blood, clerical errors may still occur. In addition, because of differences in donor selection criteria and donor-patient expectations, the consequences of certain errors may be different in autologous and allogeneic donations. STUDY DESIGN AND METHODS: In January 1996, autologous donation error rates in Canada from 1989 to November 1995 were estimated by 1) a detailed questionnaire sent to hospitals supplied by the Canadian Red Cross, Blood Services, Transfusion Center of Quebec at Montreal autologous donation program (n = 31), 2) a review of that institution's quality assurance non-compliance reports, and 3) a detailed questionnaire sent to other Canadian Red Cross centers with autologous donation programs (n = 16) and hospital-based autologous programs in Canada (n = 3). The total number of autologous donations collected was determined from Canadian Red Cross annual reports and information supplied by hospital-based programs. RESULTS: There were 113 errors reported for 16,873 units collected by the Montreal center (1/149 units) based on collection center and hospital data. The most frequent errors were the late receipt of units for surgery (25% of errors) or the receipt of units in the wrong hospital (23%). Other Canadian programs reported 166 errors for approximately 53,500 units collected (1/322 units). However, this figure was based mainly on collection center, and not hospital, data. The most frequent errors were in labeling (48%) and component preparation (25%). One unit of autologous fresh-frozen plasma was transfused to the wrong recipient. Errors were more frequent if components were produced, if units were drawn in hospitals for interhospital transfer, or it units were shipped between Red Cross centers. CONCLUSION: Errors are not infrequent in autologous donation programs. Autologous transfusion should not be considered as being without risk.


Assuntos
Doadores de Sangue , Transfusão de Sangue Autóloga/normas , Erros Médicos/estatística & dados numéricos , Canadá/epidemiologia , Estudos de Avaliação como Assunto , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Transplante Homólogo/normas
9.
Transfusion ; 37(3): 309-12, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9122905

RESUMO

BACKGROUND: Because most bacteria isolated from contaminated platelet concentrates are thought to originate from the donor's skin, the efficacy of four methods of skin disinfection was compared. STUDY DESIGN AND METHODS: Contact plates were used for antecubital skin cultures after they were demonstrated to be easier to use and at least as sensitive as a swab system. One antecubital fossa of each subject was disinfected by a standard method, the use of a povidone-iodine swabstick containing 0.75-percent available iodine followed by the use of a povidone-iodine swabstick containing 1-percent available iodine. The other arm was disinfected with either a 70-percent isopropyl alcohol scrub followed by an ampoule of 2-percent iodine tincture (Group 1; n = 126); a green-soap sponge followed by a 70-percent isopropyl alcohol swab, used for donors who are allergic to iodine (Group 2; n = 30); or a 0.5-percent chlorhexidine gluconate and 70-percent isopropyl alcohol sponge followed by an ampoule of 0.5-percent chlorhexidine gluconate and 70-percent isopropyl alcohol (Group 3; n = 40). Contact plate cultures were done before and after disinfection, and colonies counted after a 48-hour 37 degrees C incubation period. RESULTS: Similar numbers of bacteria grew from both antecubital fossae of the same subject before disinfection (p = 0.71). Compared to the standard povidoneiodine method, isopropyl alcohol and tincture of iodine resulted in significantly less bacterial growth (p < 0.001), the green soap and isopropyl alcohol method resulted in significantly more bacterial growth (p < 0.001), and the chlorhexidine gluconate and isopropyl alcohol method resulted in similar amounts of bacterial growth (p > 0.3). CONCLUSION: Isopropyl alcohol scrub followed by iodine tincture is more efficacious than povidone-iodine as measured by contact plate cultures. For donors who are allergic to iodine, chlorhexidine gluconate and isopropyl alcohol is more efficacious than green soap and isopropyl alcohol.


Assuntos
Anti-Infecciosos Locais/farmacologia , Pele/microbiologia , 1-Propanol/farmacologia , Bactérias/efeitos dos fármacos , Bactérias/crescimento & desenvolvimento , Bactérias/isolamento & purificação , Contagem de Colônia Microbiana , Estudos de Avaliação como Assunto , Humanos , Iodo/farmacologia , Flebotomia , Povidona-Iodo/farmacologia
10.
Vox Sang ; 72(1): 52-60, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9031502

RESUMO

BACKGROUND AND OBJECTIVES: Certain clinical conditions are related to the presence of platelet-specific alloantibodies in the patient's serum. We studied the molecular diversity of HPA-1a antibodies to analyze some peculiarities of this antibody response. MATERIALS AND METHODS: Human antibody Fab fragments that bind to the platelet alloantigen HPA-1a on glycoprotein IIb-IIIa (GPIIbIIIa) were generated by using a recombinant phage display system. We established an immunoglobulin G1, kappa combinatorial library from the peripheral blood lymphocytes of a person undergoing a severe posttransfusion purpura. RESULTS: Characterization of Fab clones selected from the fifth round of antigen-specific panning of this library demonstrates a highly specific reactivity to the HPA-1a alloantigen. The nucleotide sequence analysis of representative HPA-la-specific clones reveals at least 3 distinct V1 and 3VH gene segments that present an extensive degree of mutation as demonstrated by comparison of gene usage and homologies to the nearest germline genes. CONCLUSIONS: These human HPA-la-specific Fab reagents should allow us to better understand the molecular mechanism involved in HPA-la alloimmunization.


Assuntos
Antígenos de Plaquetas Humanas/imunologia , Plaquetas/imunologia , Fragmentos Fab das Imunoglobulinas/imunologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/imunologia , Sequência de Aminoácidos , Anticorpos Monoclonais/imunologia , Epitopos , Humanos , Fragmentos Fab das Imunoglobulinas/genética , Integrina beta3 , Dados de Sequência Molecular , Biblioteca de Peptídeos
12.
Blood ; 88(6): 2144-50, 1996 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-8822934

RESUMO

Intrathymic clonal deletion is thought to be the major mechanism responsible for tolerance to nonsequestered antigens such as the ones expressed by bone marrow-derived cells. In the case of sequestered antigens that potentially do not come in contact with T cells in the thymus, it is thought that autoreactive T cells are present in periphery but are tightly regulated to prevent autoimmune disease. Indeed, autoreactive T cells to sequestered antigens can be isolated in healthy individuals. However, the presence of autoreactive T cells to nonsequestered circulating antigens had not been observed. In this report, we present evidence for the presence, in the periphery of all healthy individuals tested (n = 25), of autoreactive T cells to GpIIb-IIIa, a membrane antigen present on bone marrow-derived cells that is expressed on circulating platelets and on the cell surface of the epithelial cells of the thymic stroma early in intrauterine life. Using an in vitro T-cell proliferation assay, we have demonstrated that activation of these specific GpIIb-IIIa autoreactive alpha beta TCR+ CD4+ CD8- T cells requires internalization and processing of the GpIIb-IIIa by antigen-presenting cells and its presentation by HLA-DR class II molecules in the presence of exogenous interleukin 2 (IL-2). This indicates that some autoreactive T cells directed against membrane antigens present on bone marrow-derived cells and also expressed in the thymus are not necessarily eliminated by intrathymic deletion.


Assuntos
Autoantígenos/imunologia , Autoimunidade , Medula Óssea/imunologia , Linfócitos T CD4-Positivos/imunologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/imunologia , Células Apresentadoras de Antígenos/imunologia , Antígenos de Superfície/imunologia , Células da Medula Óssea , Membrana Celular/imunologia , Endocitose , Antígenos HLA-DR/imunologia , Humanos , Ativação Linfocitária , Receptores de Interleucina-2/metabolismo
13.
Vox Sang ; 70(1): 31-3, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8928488

RESUMO

A 'new', inherited, high-frequency blood group antigen has been named PEL and is numbered 901014. Two PEL-propositi with anti-PEL have been found, both French-Canadians. Two other French-Canadian propositi with very weak expression of PEL on their red cells have an antibody, provisionally named anti-MTP, which does not react with PEL-cells.


Assuntos
Antígenos de Superfície/isolamento & purificação , Eritrócitos/imunologia , Adulto , Antígenos de Superfície/imunologia , Canadá , Feminino , Humanos
14.
Eur J Immunol ; 25(11): 3123-7, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7489752

RESUMO

Peripheral tolerance to self antigens has been suspected to play an important role in the regulation of the immune response in humans since autoreactive T cells can be isolated from the peripheral blood of healthy individuals. The mechanism of this tolerance is not known, but a number of groups have shown that autoreactive T cells can be induced to proliferate in vitro by the addition of their specific antigen and exogenous interleukin (IL)-2. In this report, we present the analysis of autoreactive T cells, isolated from healthy individuals, to the autoantigen GpIIb-IIIa present on circulating bone-marrow-derived cells and on thymic epithelial cells. We found that the response of GpIIb-IIIa autoreactive T cells in vitro, when stimulated with GpIIb-IIIa, shares characteristics with the response found for anergic T cells. In response to GpIIb-IIIa, the GpIIb-IIIa-autoreactive T cells are neither able to proliferate nor produce IL-2 on their own, but do express IL-2 receptors alpha on their cell surface and produce IFN-gamma. This state of unresponsiveness can be broken by the addition of exogenous IL-2 and IL-7, as in the case of anergic T cells. However, GpIIb-IIIa-autoreactive T cells differ from anergic T cells in their capacity to be stimulated by IL-12 and by their production of IL-2 mRNA. Interestingly, once the unresponsive state to GpIIb-IIIa has been broken by the addition of IL-2, GpIIb-IIIa autoreactive T cells can produce IL-2 and proliferate when restimulated by GpIIb-IIIa alone. Altogether, these results suggest that the tolerance of GpIIb-IIIa autoreactive T cells from healthy individuals could involve post-transcriptional regulation of IL-2 expression.


Assuntos
Tolerância Imunológica/imunologia , Interleucina-2/biossíntese , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/imunologia , Linfócitos T/imunologia , Autoimunidade/imunologia , Linhagem Celular , Anergia Clonal/imunologia , Humanos , Interferon gama/biossíntese , Interleucina-12/fisiologia , Interleucina-2/genética , Interleucina-2/fisiologia , Interleucina-7/fisiologia , Ativação Linfocitária/imunologia , Processamento Pós-Transcricional do RNA/imunologia , RNA Mensageiro/análise , Receptores de Interleucina-2/biossíntese , Receptores de Interleucina-2/genética , Linfócitos T/metabolismo
16.
Br J Haematol ; 87(4): 813-7, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7986721

RESUMO

We analysed the titre and isotype composition of antibodies produced by mothers giving birth to babies with or without neonatal alloimmune thrombocytopenic purpura (NAITP) and patients with post-transfusion purpura (PTP). All these individuals produced an antibody specific for the HPA-1a allotype present on the platelet glycoprotein IIb-IIIa (GPIIb-IIIa). Sera from mothers who gave birth to thrombocytopenic babies (group 1, n = 36), non-thrombocytopenic babies (group 2, n = 4) or from PTP patients (group 3, n = 3) were tested by an indirect-ELISA. Results indicated no evident differences in the isotype composition or titre of the antibodies from the three groups of sera. The antibody titre ranged from 1:120 to 1:3500. Antibodies with the IgG1 subclass were present in all sera. Most sera contained IgG1 alone (24/43 sera tested) or in combination with IgG3 (10/43). IgG2 was never present and only three sera showed intermediate reactivity with anti-IgG4 MAb. Few sera (nine sera from groups 1 and 2) were weakly positive when tested with the anti-IgM antibodies. These results suggest that neither the titre nor the isotype composition can be used to predict the severity or the occurrence of thrombocytopenia in newborns.


Assuntos
Antígenos de Plaquetas Humanas/imunologia , Plaquetas/imunologia , Isotipos de Imunoglobulinas/sangue , Isoanticorpos/sangue , Adulto , Idoso , Reações Antígeno-Anticorpo/imunologia , Feminino , Humanos , Imunoglobulina G/sangue , Cadeias Leves de Imunoglobulina/sangue , Recém-Nascido , Integrina beta3 , Contagem de Plaquetas , Trombocitopenia/congênito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA