Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Case Rep Intern Med ; 8(3): 002427, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33869103

RESUMO

BACKGROUND: Multimodality imaging of a cardiac mass lesion may raise suspicion of a primitive cardiac lymphoma (PCL). However, a definitive diagnosis requires histopathological confirmation. METHODS: This report describes the methodology we used to perform biopsy sampling of a cardiac mass lesion affecting a 45-year-old man. In order to increase endomyocardial biopsy diagnostic accuracy, we used pre-acquired cardiac magnetic resonance (CMR) images to guide the bioptome on a cardiac site overtly infiltrated by the suspected tumour. The right ventricular outflow tract was identified as the target site for biopsy sampling. To reduce the risk of the procedure, the biopsy was performed at a safe distance from the tip of a diagnostic quadripolar catheter positioned at the level of the pulmonary valve, previously identified by pacing manoeuvres. The reported approach demonstrated safety and diagnostic accuracy, allowing the identification of an extremely rare PCL subtype of T-cell origin. CONCLUSION: Biopsy sampling of a suspected tumour may be safely and accurately performed using pre-acquired CMR images to guide the bioptome on the target site. LEARNING POINTS: Multimodal imaging techniques capable of tissue characterization may raise suspicion of a primary cardiac lymphoma (PCL).However, the final diagnosis of PCL can be confirmed only by histological examination of a tissue sample.Biopsy sampling of the mass lesion may be accurately guided by previously acquired cardiac magnetic resonance images.

2.
J Interv Card Electrophysiol ; 50(3): 245-251, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28875448

RESUMO

PURPOSE: Complete pulmonary vein isolation (PVI) is the best documented target for catheter ablation, and different technologies have shown comparable outcomes. The multielectrode phased-RF/duty cycled (PhRF/DC) pulmonary vein ablation catheter (PVAC) and its second generation (PVAC-GOLD) have shown promising clinical results in single and multicenter experiences. Our aim is to assess and compare the safety and efficacy in the real clinical practice among two generations of circular PhRF/DC catheters by performing PVI in patients suffering from recurrent atrial fibrillation (AF). METHODS: Eighty-four AF patients treated with PVAC and 64 with PVAC-GOLD were prospectively followed in five Italian cardiology centers in the mainframe of the 1STOP-ClinicalService project. RESULTS: Fluoroscopic and total procedure time were significantly different in the two groups. In particular, in the PVAC-GOLD group, the mean fluoroscopic time was 22.8 ± 12.7 min vs 31.6 ± 18.9 in the PVAC group (p = 0.002), and the mean total procedure duration was 117.6 ± 36.0 vs 147.4 ± 40.6, in the PVAC-GOLD group and the PVAC group, respectively (p = 0.001). Only two out of 148 patients reported a peri-procedural complication. Over 20.9 ± 12.0 months of follow-up, AF recurrence occurred in 58 patients. Kaplan-Meier freedom from AF recurrence did not differ between the two groups (64.1 ± 10% in the PVAC group vs 68.2 ± 9% in the PVAC-GOLD group at 1 year, p = ns). CONCLUSIONS: In our multicenter analysis, AF ablation using two generations of circular PhRF/DC catheters is safe and effective. No difference was observed in terms of safety and efficacy of the AF ablation between the two catheters, with the mean procedural time being shorter in the PVAC-GOLD group.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/mortalidade , Cateteres Cardíacos , Ablação por Cateter/mortalidade , Estudos de Coortes , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Fluoroscopia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/diagnóstico por imagem , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
3.
Anadolu Kardiyol Derg ; 12(2): 132-41, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22281793

RESUMO

OBJECTIVE: To understand whether patients with post-ischemic dilated cardiomyopathy and myocardial viability (MV) could benefit from cardiac resynchronization therapy (CRT) in terms of clinical, echocardiographic and neuro- hormonal parameters compared to patients without MV. METHODS: One hundred and four consecutive patients were enrolled in a prospective observational cohort study. Using dobutamine stress echocardiography, 2 groups were identified: group A of 51 patients with MV and group B of 53 patients without MV. All patients were implanted with biventricular pacing devices combined with an internal cardioverter-defibrillator. Clinical, echocardiographic and neuro-hormonal parameters were evaluated at baseline and at six month follow-up. Analysis of variance for repeated measures on each variable suggestive of remodeling was performed. We considered responder every patient with: decrease of > 15% in left ventricular volumes and/or improvement in left ventricular ejection fraction of > 5% in addition to NYHA class improvement. RESULTS: All the variables improved in both groups (time effect). Comparing the two groups (group effect), the following variables were significantly better in group A: N-terminal pro-B-type natriuretic peptide (p=0.02), NYHA class (p=0.003), reverse remodeling (RR) (p=0.007), dP/dt (p=0.005), left ventricular ejection fraction (p=0.009), 3rd sound (p=0.01), and left ventricular end-systolic volume after the first week (p=0.035). RR occurred at the first week after CRT only in Group A and was maintained for all the time of this study. The maximum difference of the decrease of left ventricular volumes between the two groups occurred after the first week (p<0.001). CONCLUSION: Patients with MV responded better than patients without MV with a significant improvement after the first week from CRT.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/terapia , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/fisiopatologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
4.
Heart Rhythm ; 5(11): 1510-6, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18984524

RESUMO

BACKGROUND: A novel catheter design (HD Mesh ablator, Bard) combining high-density circumferential mapping and direct radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). OBJECTIVE: The purpose of this study was to assess the feasibility of the Mesh catheter for PV isolation in patients with paroxysmal atrial fibrillation (AF). METHODS: Twenty consecutive patients (mean age 56.4 +/- 12.2 years; 16 men) with paroxysmal drug-refractory AF were referred for ablation. The procedure was performed in a stepwise manner: PV isolation was initially attempted with the Mesh ablator, and if that was not successful, a conventional ablation approach was then used. RESULTS: A total of 73 PVs including seven veins with left common ostium were targeted. Successful deployment of the Mesh was achieved in all but four veins (94.5%). Using the Mesh catheter for ablation, PV isolation was achieved in 46 (63%) of the 73 PVs. The mean (RF) ablation time required to achieve complete isolation was 12.4 +/- 6.1 minutes per PV. The Mesh-only approach allowed isolation of all veins in eight (40%) patients. In combination with conventional ablation, successful PV isolation was achieved in 71 (97%) of 73 PVs. No complications attributable to the Mesh ablator occurred in this series. CONCLUSIONS: PV isolation using the Mesh catheter is feasible and may simplify the current PV isolation procedures. With the current catheter design, PV isolation could be achieved in 63% of PVs. A larger Mesh diameter with an over-the-wire design may help improve the acute success rate.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 19(11): 1127-34, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18554207

RESUMO

UNLABELLED: Voltage Mapping-Guided Biopsy in ARVC/D. INTRODUCTION: To improve the endomyocardial biopsy (EMB) diagnostic sensitivity for arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D), we hypothesized a biopsy sampling focused on selected right ventricle (RV) low-voltage areas identified by electroanatomic voltage mapping. METHODS AND RESULTS: The study population (22 patients, 10 men; mean age 34 +/- 10 years) included 11 patients with overt ARVC/D (group A) and 11 patients with suspected ARVC/D (group B), according to both arrhythmic profile and standardized noninvasive diagnostic criteria. In all 22 patients, an RV bipolar voltage mapping was performed with CARTO system sampling multiple endocardial sites (262 +/- 61), during sinus rhythm, with a 0.5-1.5 mV color range setting of voltage display. All 11 (100%) group A patients and 8 of the 11 (73%) group B patients (P = nonsignificant [NS]) presented RV low-voltage areas (<0.5 mV). In 8 group A patients and in all 8 group B patients with a pathological RV voltage map, an EMB focused on the low-voltage areas was performed. In 6 (75%) group A patients and in 7 (87%) group B patients (P = NS), voltage mapping-guided EMB was diagnostic for ARVC/D. In the remaining 3 patients, only nonspecific histological findings were observed. CONCLUSIONS: The results of our study (1) confirm the high diagnostic sensitivity of RV voltage mapping in patients with overt ARVC/D, (2) document a high prevalence of RV low-voltage areas even in patients with suspected ARVC/D, and (3) demonstrate that in patients with clinical evidence or suspicion for ARVC/D, presenting RV low-voltage areas, EMB guided by voltage mapping may provide ARVC/D diagnosis confirmation.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Biópsia por Agulha/métodos , Mapeamento Potencial de Superfície Corporal/métodos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos
6.
Ital Heart J Suppl ; 5(8): 639-46, 2004 Aug.
Artigo em Italiano | MEDLINE | ID: mdl-15554019

RESUMO

BACKGROUND: Three-dimensional nonfluoroscopic system may be helpful to guide radiofrequency catheter ablation procedures and to reduce the radiological exposure. A new intracardiac navigation and multicatheter visualization system based on Ohm's law (LocaLisa, Medtronic, Minneapolis, MN, USA) has been recently introduced. The aim of our study was to assess the efficacy of the Loca-Lisa system in comparison to fluoroscopy-based approach in reducing the radiological exposure time required for radiofrequency catheter ablation procedures. METHODS: One hundred and thirty-seven consecutive patients underwent LocaLisa-based radiofrequency catheter ablation procedures in our cardiac electrophysiology laboratory during 19 months of LocaLisa utilization (from October 2001 to April 2003): 46 atrial flutter, 44 atrioventricular node reentrant tachycardia, 16 atrioventricular reentry tachycardia due to atrioventricular accessory pathway, 14 atrial fibrillation, 11 ectopic atrial tachycardia, and 6 atrioventricular node modulation. We retrospectively compared the radiological exposure times of this group of patients to those of the last 137 patients undergone fluoroscopy-based radiofrequency catheter ablation procedures for curing the same index arrhythmia by the same procedural protocol. RESULTS: The mean radiological exposure time was significantly shorter for the LocaLisa-based radiofrequency catheter ablation procedures (16 +/- 12 vs 34 +/- 17 min; reduction of 53%, p < 0.01) and it occurred for all the arrhythmia types. The reduction was of 64% (from 39 +/- 18 to 14 +/- 12 min, p < 0.01) for atrial flutter, 42% (from 24 +/- 10 to 14 +/- 11 min, p < 0.01) for atrioventricular nodal reentrant tachycardia, 30% (from 40 +/- 14 to 28 +/- 14 min, p = 0.02) for atrioventricular reentry tachycardia, 57% (from 49 +/- 12 to 21 +/- 13 min, p < 0.01) for atrial fibrillation (right atrial linear lesions), 50% (from 38 +/- 12 to 19 +/- 8 min, p < 0.01) for ectopic atrial tachycardia and 42% (from 12 +/- 11 to 7 +/- 5 min, p = NS) for atrioventricular node modulation. The reduction in the radiological exposure time progressively increased as our team got used with the nonfluoroscopic navigation system. CONCLUSIONS: Overall and single arrhythmia-divided mean radiological exposure times can be significantly reduced by the LocaLisa system during radiofrequency catheter ablation procedures. The reduction of radiation increases progressively by becoming friendly to the system with a very short duration of learning curve phase.


Assuntos
Ablação por Cateter/métodos , Estudos de Casos e Controles , Eletrofisiologia , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
7.
Ital Heart J Suppl ; 5(3): 221-4, 2004 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-15116869

RESUMO

The most common initial symptom of acute aortic dissection is chest or abdominal pain. Nevertheless, in a minority of cases, it may have an atypical presentation, making the diagnosis clinically challenging. This article reports on a case of acute type A aortic dissection presenting as mental status confusion. The diagnostic suspicion for a cerebrovascular accident may have catastrophic consequences in a clinical condition, which is associated with a high mortality during the first 48 hours after the onset of symptoms if untreated. The right diagnosis was made by combining a careful physical examination, echocardiography, and computed tomography. The available literature about neurologic manifestations, their pathophysiology and prevalence as the initial symptom of acute type A aortic dissection is reviewed.


Assuntos
Aorta , Aneurisma da Aorta Torácica/psicologia , Aneurisma Aórtico/psicologia , Dissecção Aórtica/psicologia , Tronco Braquiocefálico , Confusão/etiologia , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Aortografia , Implante de Prótese Vascular , Isquemia Encefálica/diagnóstico , Diagnóstico Diferencial , Ecocardiografia , Cefaleia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Vômito/etiologia
8.
Blood Coagul Fibrinolysis ; 15(1): 95-8, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15166950

RESUMO

Antiphospholipid syndrome is a disorder characterized by arterial and venous thromboses, thrombocytopaenia and stroke. Acute myocardial infarction is rarely associated with this syndrome. The treatment of these patients is a clinical challenge. This report is about a patient with antiphospholipid syndrome presenting with an acute myocardial infarction after an exercise test. The infarct-related coronary artery was successfully revascularized by primary angioplasty and stenting without any major bleeding complications. We think that the physical exertion could have favoured acute coronary thrombosis in this particular setting.


Assuntos
Angioplastia Coronária com Balão , Síndrome Antifosfolipídica/complicações , Infarto do Miocárdio/terapia , Stents , Teste de Esforço/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/etiologia , Resultado do Tratamento , Trombose Venosa/tratamento farmacológico , Trombose Venosa/etiologia , Varfarina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA