Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Eur Heart J Suppl ; 26(Suppl 1): i23-i28, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38867874

RESUMO

The identification of ventricular premature complexes during a cardiological evaluation necessitates the implementation of diagnostic processes aimed at discerning the clinical context that may predispose individuals to a high risk of sudden cardiac death. Epidemiological studies reveal that ventricular premature beats occur in approximately 75% of healthy (or seemingly healthy) individuals, as long as there is no evidence of underlying structural heart disease, such as benign idiopathic ventricular extrasystole originating from the right and left ventricular outflow tracts. In the real world, however, ventricular ectopic beats with morphologies very similar to seemingly benign occurrences are not uncommon. They are notable in subjects exhibiting rapid and complex repetitive forms during exercise testing and Holter electrocardiogram. Additionally, these subjects may display more or less extensive scarring signs on cardiac magnetic resonance and may have a family history of cardiomyopathy and/or sudden cardiac death. Therefore, the purpose of this review is to critically analyse the process of evaluating premature ventricular complexes, which is crucial for accurate risk stratification. The latter cannot overlook some inevitable elements, including morphology, origin, complexity, and the associated clinical setting (absence or presence of structural heart disease).

2.
JACC Clin Electrophysiol ; 9(12): 2615-2627, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37768253

RESUMO

BACKGROUND: Electrocardiographic (ECG) findings in arrhythmogenic left ventricular cardiomyopathy (ALVC) are limited to small case series. OBJECTIVES: This study aimed to analyze the ECG characteristics of ALVC patients and to correlate ECG with cardiac magnetic resonance and genotype data. METHODS: We reviewed data of 54 consecutive ALVC patients (32 men, age 39 ± 15 years) and compared them with 84 healthy controls with normal cardiac magnetic resonance. RESULTS: T-wave inversion was often noted (57.4%), particularly in the inferior and lateral leads. Low QRS voltages in limb leads were observed in 22.2% of patients. The following novel ECG findings were identified: left posterior fascicular block (LPFB) (20.4%), pathological Q waves (33.3%), and a prominent R-wave in V1 with a R/S ratio ≥0.5 (24.1%). The QRS voltages were lower in ALVC compared with controls, particularly in lead I and II. At receiver-operating characteristic analysis, the sum of the R-wave in I to II ≤8 mm (AUC: 0.909; P < 0.0001) and S-wave in V1 plus R-wave in V6 ≤12 mm (AUC: 0.784; P < 0.0001) effectively discriminated ALVC patients from controls. It is noteworthy that 4 of the 8 patients with an apparently normal ECG were recognized by these new signs. Transmural late gadolinium enhancement was associated to LPFB, a R/S ratio ≥0.5 in V1, and inferolateral T-wave inversion, and a ringlike pattern correlated to fragmented QRS, SV1+RV6 ≤12 mm, low QRS voltage, and desmoplakin alterations. CONCLUSIONS: Pathological Q waves, LPFB, and a prominent R-wave in V1 were common ECG signs in ALVC. An R-wave sum in I to II ≤8 mm and SV1+RV6 ≤12 mm were specific findings for ALVC phenotypes compared with controls.


Assuntos
Cardiomiopatias , Meios de Contraste , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Gadolínio , Eletrocardiografia , Arritmias Cardíacas , Bloqueio de Ramo
3.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37527153

RESUMO

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Síndromes de Pré-Excitação , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Feixe Acessório Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Fatores de Risco , Eletrocardiografia
4.
Front Cardiovasc Med ; 10: 1115328, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529713

RESUMO

Aims: Supraventricular tachycardias may trigger atrial fibrillation (AF). The aim of the study was to evaluate the prevalence of supraventricular tachycardia (SVT) inducibility in patients referred for AF ablation and to evaluate the effects of SVT ablation on AF recurrences. Methods and results: 249 patients (mean age: 54 ± 14 years) referred for paroxysmal AF ablation were studied. In all patients, only AF relapses had been documented in the clinical history. 47 patients (19%; mean age: 42 ± 11 years) had inducible SVT during the electrophysiological study and underwent an ablation targeted only at SVT suppression. Ablation was successful in all 47 patients. The ablative procedures were: 11 slow-pathway ablations for atrioventricular nodal re-entrant tachycardia; 6 concealed accessory pathway ablations for atrioventricular re-entrant tachycardia; 17 focal ectopic atrial tachycardia ablations; 13 with only one arrhythmogenic pulmonary vein. No recurrences of SVT were observed during the follow-up (32 ± 18 months). 4 patients (8.5%) showed recurrence of at least one episode of AF. Patients with inducible SVT had less structural heart disease and were younger than those without inducible SVT. Conclusion: A significant proportion of candidates for AF ablation are inducible for an SVT. SVT ablation showed a preventive effect on AF recurrences. Those patients should be selected for simpler ablation procedures tailored only to the triggering arrhythmia suppression.

5.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37466354

RESUMO

AIMS: Left ventricular scar is an arrhythmic substrate that may be missed by echocardiography and diagnosed only by cardiac magnetic resonance (CMR), which is a time-consuming and expensive imaging modality. Premature ventricular complexes (PVCs) with a right-bundle-branch-block (RBBB) pattern are independent predictors of late gadolinium enhancement (LGE) but their positive predictive value is low. We studied which electrocardiographic features of PVCs with an RBBB pattern are associated with a higher probability of the absence of an underlying LGE. METHODS: The study included 121 athletes (36 ± 16 years; 48.8% men) with monomorphic PVCs with an RBBB configuration and normal standard clinical investigations who underwent CMR. LGE was identified in 35 patients (29%), predominantly in those with PVCs with a superior/intermediate axis (SA-IntA) compared to inferior axis (IA) (38% vs. 10%, P = 0.002). Among patients with SA-IntA morphology, the contemporary presence of qR pattern in lead aVR and V1 was exclusively found in patients without LGE at CMR (51.0% vs. 0%, P < 0.0001). Among patients with IA, the absence of LGE correlated to a narrow ectopic QRS (145 ± 16 vs. 184 ± 27 msec, P < 0.001). CONCLUSIONS: Among athletes with apparently idiopathic PVCs with a RBBB configuration, the presence of a concealed LGE at CMR was documented in 29% of cases, mostly in those with a SA-IntA. In our experience, the contemporary presence of qR pattern in lead aVR and V1 in PVCs with RBBB/SA-IntA morphology or, on the other hand, a relatively narrow QRS in PVCs with an IA, predicted absence of LGE.


Assuntos
Cicatriz , Complexos Ventriculares Prematuros , Masculino , Humanos , Feminino , Meios de Contraste , Gadolínio , Ventrículos do Coração/diagnóstico por imagem , Eletrocardiografia/métodos , Bloqueio de Ramo , Atletas
6.
J Arrhythm ; 39(3): 310-314, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37324770

RESUMO

Advances in cardiac implantable electronic devices (CIEDs) have prolonged life expectancy in various medical settings. However, the issue of hypersensitivity to components of CIEDs is still a concern. Since 1970, allergic reactions to metallic and nonmetallic components of CIEDs have been reported. Hypersensitivity reactions to medical devices are rare and not fully understood. In some cases, diagnosis and treatment are difficult. Cardiologists should always keep in mind pacemaker allergy when a patient appears with wound complications and no signs of infection. Patch testing should be tailored toward the specific biomaterials used in a device, in addition to testing with standard screening allergens in select cases.

7.
Eur Heart J Suppl ; 25(Suppl C): C265-C270, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125279

RESUMO

Radiofrequency (RF) catheter ablation has become a widely used therapeutic approach. However, long-term results in terms of arrhythmia recurrence are still suboptimal. Cardiac magnetic resonance (CMR) could offer a valuable tool to overcome this limitation, with the possibility of targeting the arrhythmic substrate and evaluating the location, depth, and possible gaps of RF lesions. Moreover, real-time CMR-guided procedures offer a radiation-free approach with an evaluation of anatomical structures, substrates, RF lesions, and possible complications during a single procedure. The first steps in the field have been made with cavotricuspid isthmus ablation, showing similar procedural duration and success rate to standard fluoroscopy-guided procedures, while allowing visualization of anatomic structures and RF lesions. These promising results open the path for further studies in the context of more complex arrhythmias, like atrial fibrillation and ventricular tachycardias. Of note, setting up an interventional CMR (iCMR) centre requires safety and technical standards, mostly related to the need for CMR-compatible equipment and medical staff's educational training. For the cardiac imagers, it is fundamental to provide correct CMR sequences for catheter tracking and guide RF delivery. At the same time, the electrophysiologist needs a rapid interpretation of CMR images during the procedures. The aim of this paper is first to review the logistic and technical aspects of setting up an iCMR suite. Then, we will describe the experience in iCMR-guided flutter ablations of two European centres, Policlinico Casilino in Rome, Italy, and Haga Teaching Hospital in The Hague, the Netherlands.

8.
Eur Heart J Suppl ; 25(Suppl C): C1-C6, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125283

RESUMO

For several years, the autonomic nervous system has played a central role in the pathophysiological mechanism of atrial fibrillation (AF), so much so that it has been considered one of the cornerstones of Coumel's triangle. The clinical and therapeutic management of AF secondary to sympatho-vagal imbalance represents one of the most important examples of how precision medicine should be applied. Increasing knowledge of this kind of arrhythmias has made it possible to select specific antiarrhythmic drugs and to diversify their use according to vagal or adrenergic AF forms. Ablative strategies, such as cardioneuroablation and non-direct cardiac neuromodulation methods (such as renal denervation and peripheral vagal stimulation), have gradually emerged. In the possibly near future, there will be a development of new acquisitions regarding new pharmacological therapeutic strategies and gene therapy. Finally, finding an AF in patients experiencing syncopal episodes opens a whole chapter regarding interesting, but also complex, diagnostic and therapeutic strategies, ranging from neurally mediated forms to convulsive seizure that could also increase the risk of sudden death.

9.
Eur Heart J Suppl ; 25(Suppl C): C344-C348, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125286

RESUMO

Implantable cardiac monitors (ICMs) have found increasing use in clinical practice over the years, proving, when used in high-risk populations, to facilitate the diagnosis of bradyarrhythmias and tachyarrhythmias requiring treatment. Experience with heart failure patients undergoing pacemaker (PMK) or implantable defibrillator (ICD) implantation, which allow for continuous electrocardiographic monitoring and transthoracic impedance assessment, has made it possible to identify predictors of heart failure flare-ups. In this context, the use of telemonitoring has been shown to ensure better management of patients with heart failure. These benefits cannot be assessed to date in patients with heart failure and left ventricular ejection fraction (LVEF) > 35% who have no indication for PMK or ICD implantation. This population has been shown to have a significant incidence of ventricular arrhythmias and bradyarrhythmias. In addition, a significant number of cerebrovascular events are observed in this population, largely attributable to the high incidence of atrial fibrillation (AF). In this population, the occurrence of AF has also been shown to have a negative impact on patients' prognosis; at the same time, a rhythm control strategy has been shown to be more beneficial in this area than a rate control strategy. Studies also suggest arrhythmias have a negative impact on the cognitive status and quality of life of heart failure patients. These reasons could justify the implantation of ICMs equipped with telemonitoring systems in heart failure patients. The information provided by the monitoring system, if properly managed, could bring benefits in terms of prognosis and quality of life along with a reduction in economic costs. We will try here, by answering a few questions, to assess whether there is an indication for ICM in heart failure, which patients should be candidates and how these patients should be managed.

10.
Eur Heart J Suppl ; 25(Suppl C): C179-C184, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125290

RESUMO

This article summarizes the main electrocardiogram (ECG) findings in dilated cardiomyopathy (DCM) patients. Recent reports are described in the great 'pot' of DCM peculiar ECG patterns that are typical of specific forms of DCM. Patients with late gadolinium enhancement on CMR, who are at greatest arrhythmic risk, have also distinctive ECG features. Future studies in large DCM populations should evaluate the diagnostic and prognostic value of the ECG.

11.
Eur Heart J Suppl ; 25(Suppl C): C218-C226, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125292

RESUMO

Sudden cardiac death (SCD) can be caused by several clinical conditions, overt or misconceived, which recognize different pathophysiologies determining the development of fatal arrhythmic events. In the various forms of structural heart disease such as ischaemic heart disease, cardiomyopathies (e.g. hypertrophic cardiomyopathy, dilated cardiomyopathy, and arrhythmogenic cardiomyopathy), channelopathies (e.g. long-QT syndrome, congenital short QT, Brugada syndrome, early repolarization (ER) syndrome, and idiopathic ventricular fibrillation) but also in the apparently healthy subject, the 12-lead electrocardiogram (ECG) has proved, over the years, to be a reliable and readily available method for stratifying the risk of adverse arrhythmic events and consequently SCD. Several electrocardiographic markers have been shown to be associated with adverse outcomes in different types of patients. Although with different sensitivity and specificity in each clinical condition, depolarization abnormalities, such as QRS fragmentation, Q waves, QRS duration, left posterior fascicular block, low QRS voltage, and left ventricular hypertrophy and similarly repolarization abnormalities as ER pattern, T wave alternans, QT interval, and QT dispersion, have shown significant efficacy in predicting SCD. Despite the advancement of techniques especially in the field of imaging, the correct interpretation of the 12-lead ECG remains, therefore, an effective tool for assessing the possible prognostic outcome in terms of arrhythmic risk and SCD in different types of patients.

12.
Eur Heart J Suppl ; 25(Suppl C): C261-C264, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125307

RESUMO

Neurocardiogenic syncope, also called vasovagal syncope, represents one of the clinical manifestations of neurally mediated syncopal syndrome. Generally, the prognosis of the cardioinhibitory form of neurocardiogenic syncope is good, but quality of life is seriously compromised in patients who experience severe forms. Drug therapy has not achieved good clinical results and very heterogeneous data come from studies regarding permanent cardiac pacing. In this scenario, the ganglionated plexi ablation has been proposed as an effective and safe method in patients with cardioinhibitory neurocardiogenic syncope, especially in young patients in order to avoid or prolong, as much as possible, the timing of definitive cardiac pacing. Certainly, making this procedure less extensive and limiting the ablation in the right atrium (avoiding the potential complications of a left atrial approach) and at level of anatomical regions of the most important ganglionated plexy, considered 'gateway' of the sino-atrial and atrio-ventricular node function (through the recognition of specific endocardial potentials), could be very advantageous in this clinical scenario. Finally, randomized, multicentre, clinical trials on a large population are needed to better understand which is the best ablation treatment (right-only or bi-atrial) and provide evidence for syncope guidelines.

13.
Eur Heart J Suppl ; 25(Suppl C): C253-C257, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125309

RESUMO

Radiofrequency catheter ablation of the cavotricuspid isthmus is the standard treatment for patients suffering from typical atrial flutter. The aim of this study was to test the feasibility of tissue thickness and lesion transmurality measurement by a novel dielectric system. This was a retrospective multicentric non-randomized open-label, single-arm study. The atrial wall thickness was significantly higher close to the tricuspid annulus than close to the inferior vena cava and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspid valve to the inferior vena cava. The possibility to visualize the tissue thickness could modify the way to deliver radiofrequency energy, allowing a tailored approach in cardiac ablation procedures.

14.
Eur Heart J Suppl ; 25(Suppl C): C185-C188, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125310

RESUMO

Magnetic resonance (MR) represents a new interesting imaging approach for guiding electrophysiology (EP)-based ablation procedures of atrial flutter and typical atrial fibrillation. This new approach permits to reach good results if compared with conventional EP ablation. Tissue characterization by MR permits to detect cardiac anatomy and pathological substrate like myocardial scars well visualized with late gadolinium enhancement (LGE) sequences. Intra-procedural imaging is useful to real-time follow the catheter during the ablation procedure and at the same time to visualize cardiac anatomy in addition to understanding if the ablation is correctly performed using oedema sequences. Performing cardiac ablations inside an MR room permits to reduce radiation exposure and occupational illnesses.

15.
Eur Heart J Suppl ; 25(Suppl C): C169-C172, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125311

RESUMO

Criteria for diagnosis of arrhythmogenic cardiomyopathy (ACM) were first proposed in 1994 and subsequently revised in 2010 and in 2020 by an international task force. According to the last consensus of 2020, ACM is defined as a heart muscle disease affecting right ventricle, left ventricle or both, whose principal pathologic feature is fibrofatty myocardial replacement that impairs systolic ventricular function and predisposes to lethal ventricular arrhythmias. ECG findings not only could help to early recognize affected patients but also could identify the ones with maximum risk of ventricular arrhythmias and sudden cardiac death.

16.
Eur Heart J Suppl ; 25(Suppl C): C234-C241, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125312

RESUMO

The conduction system of the human heart is composed of specialized cardiomyocytes that initiate and propagate the electric impulse with consequent rhythmic and synchronized contraction of the atria and ventricles, resulting in the normal cardiac cycle. Although the His-Purkinje system (HPS) was already described more than a century ago, there has been a recent resurgence of conduction system pacing (CSP), where pacing leads are positioned in the His bundle region and left bundle branch area to provide physiological cardiac activation as alternatives to the unnatural myocardial stimulation obtained with conventional right ventricular and biventricular pacing. In this review, we describe the fundamental anatomical and pathophysiological aspects of the specialized HPS along with the CSP technique's nuts and bolts to highlight its potential benefits in everyday clinical practice.

17.
Eur Heart J Suppl ; 25(Suppl C): C326-C330, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125315

RESUMO

Heart failure (HF) is one of the main causes of morbidity in the world and is responsible for an enormous amount of health costs, mostly due to hospitalizations. The remote control techniques of vital signs and health status have the potential to help prevent factors leading to HF instability by stimulating early therapeutic interventions. The goal of telemedicine is to change the intervention strategy from a 'reactive' type, in which therapy is optimized in response to the worsening of symptoms, to a 'pro-active' type, in which therapeutic changes are undertaken based on changes in the monitored parameters during the sub-clinical phase. This article is aimed at exploring the major results obtained by telemedicine application in HF patients with and without cardiac electronic devices or in those with haemodynamic sensors and to analyse the critical issues and the opportunities of its use.

18.
Life (Basel) ; 13(5)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37240784

RESUMO

Arrhythmogenic substrate, modulating factors, and triggering factors (the so-called Coumel's triangle concept) play a primary role in atrial fibrillation (AF) pathophysiology. Several years have elapsed since Coumel and co-workers advanced the concept of the relevance of autonomic nervous system (ANS) influences on atrial cells' electrophysiological characteristics. The ANS is not only associated with cardiac rhythm regulation but also exerts an important role in the triggering and maintenance of atrial fibrillation. This review aims to describe in detail the autonomic mechanisms involved in the pathophysiology of atrial fibrillation (AF), starting from the hypothesis of an "Autonomic Coumel Triangle" that stems from the condition of the fundamental role played by the ANS in all phases of the pathophysiology of AF. In this article, we provide updated information on the biomolecular mechanisms of the ANS role in Coumel's triangle, with the molecular pathways of cardiac autonomic neurotransmission, both adrenergic and cholinergic, and the interplay between the ANS and cardiomyocytes' action potential. The heterogeneity of the clinical spectrum of the ANS and AF, with the ANS playing a relevant role in situations that may promote the initiation and maintenance of AF, is highlighted. We also report on drug, biological, and gene therapy as well as interventional therapy. On the basis of the evidence reviewed, we propose that one should speak of an "Autonomic Coumel's Triangle" instead of simply "Coumel's Triangle".

19.
J Interv Card Electrophysiol ; 66(7): 1749-1757, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36869990

RESUMO

BACKGROUND: A novel ablation catheter has been released to map and ablate the cavo-tricuspid isthmus (CTI) in patients with atrial flutter (AFL), improving ablation efficiency. METHODS: We evaluated the acute and long-term outcome of CTI ablation aiming at bidirectional conduction block (BDB) in a prospective, multicenter cohort study enrolling 500 patients indicated for typical AFL ablation. Patients were grouped on the basis of the AFL ablation method (linear anatomical approach, Conv group n = 425, or maximum voltage guided, MVG group, n = 75) and ablation catheter (mini-electrodes technology, MiFi group, n = 254, or a standard 8-mm ablation catheter, BLZ group, n = 246). RESULTS: Complete BDB according to both validation criteria (sequential detailed activation mapping or mapping only the ablation site) was achieved in 443 patients (88.6%). The number of RF applications needed to achieve BDB was lower in the MiFi MVG group vs both the MiFi Conv group and the BLZ Conv group (3.2 ± 2 vs 5.2 ± 4 vs 9.3 ± 5, p < 0.0001 for all comparisons). Fluoroscopy time was similar among groups, whereas we observed a reduction in the procedure duration from the BLZ Conv group (61.9 ± 26min) to the MiFi MVG group (50.6 ± 17min, p = 0.048). During a mean follow-up of 548 ± 304 days, 32 (6.2%) patients suffered an AFL recurrence. No differences were found according to BDB achieved by both validation criteria. CONCLUSIONS: Ablation was highly effective in achieving acute CTI BDB and long-term arrhythmia freedom irrespective of the ablation strategy or the validation criteria for CTI chosen by the operator. The use of an ablation catheter equipped with mini-electrodes technology seems to improve ablation efficiency. CLINICAL TRIAL REGISTRATION: Atrial Flutter Ablation in a Real World Population. (LEONARDO). CLINICALTRIALS: gov Identifier: NCT02591875.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Estudos de Coortes , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Resultado do Tratamento , Estudos Clínicos como Assunto
20.
Artigo em Inglês | MEDLINE | ID: mdl-36901531

RESUMO

Rapidly growing worldwide, 5G service is expected to deeply change the way we communicate, connect and share data. It encompasses the whole spectrum of new technology, infrastructure and mobile connectivity, and will touch not only every sector in the industry, but also many aspects of our everyday life. Although the compliance with international regulations provides reasonable protection to public health and safety, there might be specific issues not fully covered by the current technical standards. Among the aspects that shall be carefully considered, there is the potential interference that can be induced on medical devices, and in particular on implantable medical devices that are critical for the patient's life, such as pacemakers and implantable defibrillators. This study aims to assess the actual risk that 5G communication systems pose to pacemakers and implantable defibrillators. The setup proposed by the ISO 14117 standard was adapted to include 5G characteristic frequencies of 700 MHz and 3.6 GHz. A total number of 384 tests were conducted. Among them, 43 EMI events were observed. Collected results reveal that RF hand-held transmitters operating in these two frequency bands do not pose additional risk compared to pre-5G bands and that the safety distance of 15 cm typically indicted by the PM/ICD manufacturer is still able to guarantee the patient's safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA