Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007829

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Fatores de Risco , Pessoa de Meia-Idade
4.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38152923

RESUMO

OBJECTIVES: Relevant paravalvular leakage (PVL) due to prosthesis dislodgement is a rare but potentially severe complication after transcatheter mitral valve implantation (TMVI). Due to the epicardial anchoring mechanism of the Tendyne® TMVI system, repositioning of the valve stent may be possible by retensioning of the tether. This multicentre study aimed to investigate the procedural and short-term safety as well as efficacy of retensioning manoeuvres. METHODS: From 2017 to 2021, N = 18 patients who underwent secondary tether retensioning were identified. Baseline, procedural and follow-up data were available from N = 11 patients and analysed according to the Mitral Valve Research Consortium definitions. Continuous variables are shown as median with interquartile range. RESULTS: All patients [age 75 years (73.5, 85.0), 64% male (N = 7), EuroSCORE II 6.2% (5.8, 11.6)] presented with post-procedural PVL [63.6% (N = 7) with PVL ≥3+]. Of these, 54% (N = 6) showed signs of haemolysis. The majority were severely symptomatic [New York Heart Association ≥III (91%, N = 10)]. Procedural outcomes revealed no acute complications and no mortality. At discharge, PVL was completely eliminated in 91% (N = 10) of patients with 1 case of remaining moderate PVL. At 30 days, Mitral Valve Research Consortium device success was achieved in 82% (N = 9) of patients. Two patients required open surgical mitral valve replacement due to persistent and recurrent PVL. In 89% (N = 8) of patients with successful retensioning procedure, New York Heart Association class was I/II. There was no 30-day mortality. CONCLUSIONS: This multicentre study demonstrates technical feasibility, procedural safety and acute efficacy of retensioning procedures in the majority of patients. The potential to retension the tether in transapical TMVI may provide additional management advantages in populations at high surgical risk.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , New York , Cateterismo Cardíaco/métodos
7.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

8.
Curr Opin Cardiol ; 38(6): 478-483, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37556404

RESUMO

PURPOSE OF REVIEW: Coronary artery disease is the third leading cause of mortality worldwide. Coronary artery surgery is an important treatment option. Certain groups such as people of color, those from lower socioeconomic backgrounds and women tend to have lower rates of receiving the surgery they need ( Fig. 1 ). RECENT FINDINGS: Still there are disparities in treatment options for coronary artery disease among different groups, due to geographic location, economical situation, institutional tradition and sex. SUMMARY: Through continued research, awareness and utilization of innovative technologies, we can improve access and equity in healthcare for all patients, including patients in need of coronary surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doença da Artéria Coronariana , Humanos , Feminino , Doença da Artéria Coronariana/cirurgia , Ponte de Artéria Coronária , Procedimentos Cirúrgicos Vasculares , Disparidades em Assistência à Saúde
10.
EuroIntervention ; 19(6): 512-525, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37235388

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) using dedicated devices is an alternative therapy for high-risk patients with symptomatic mitral regurgitation (MR). AIMS: This study aimed to assess the 2-year outcomes and predictors of mortality in patients undergoing TMVR from the multicentre CHOICE-MI Registry. METHODS: The CHOICE-MI Registry included consecutive patients with symptomatic MR treated with 11 different dedicated TMVR devices at 31 international centres. The investigated endpoints included mortality and heart failure hospitalisation rates, procedural complications, residual MR, and functional status. Multivariable Cox regression analysis was applied to identify independent predictors of 2-year mortality. RESULTS: A total of 400 patients, median age 76 years (interquartile range [IQR] 71, 81), 59.5% male, EuroSCORE II 6.2% (IQR 3.8, 12.0), underwent TMVR. Technical success was achieved in 95.2% of patients. MR reduction to ≤1+ was observed in 95.2% at discharge with durable results at 1 and 2 years. New York Heart Association Functional Class had improved significantly at 1 and 2 years. All-cause mortality was 9.2% at 30 days, 27.9% at 1 year and 38.1% at 2 years after TMVR. Chronic obstructive pulmonary disease, reduced glomerular filtration rate, and low serum albumin were independent predictors of 2-year mortality. Among the 30-day complications, left ventricular outflow tract obstruction, access site and bleeding complications showed the strongest impact on 2-year mortality. CONCLUSIONS: In this real-world registry of patients with symptomatic MR undergoing TMVR, treatment with TMVR was associated with a durable resolution of MR and significant functional improvement at 2 years. Two-year mortality was 38.1%. Optimised patient selection and improved access site management are mandatory to improve outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
11.
Circ Cardiovasc Interv ; 16(6): e013045, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194288

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. METHODS: The CHOICE-MI registry (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) included patients with MR undergoing TMVR using dedicated devices. Patients with MR pathogeneses other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation). We compared outcomes between the TMVR and GDMT groups, using propensity score matching to adjust for baseline differences. RESULTS: After propensity score matching, 97 patient pairs undergoing TMVR (72.9±8.7 years; 60.8% men; transapical access, 91.8%) versus GDMT (73.1±11.0 years; 59.8% men) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared with 6.9% and 7.7%, respectively, in those receiving GDMT alone (both P<0.001). The 2-year rate of heart failure hospitalization was significantly lower in the TMVR group (32.8% versus 54.4%; hazard ratio, 0.59 [95% CI, 0.35-0.99]; P=0.04). Among survivors, a higher proportion of patients were in the New York Heart Association functional class I or II in the TMVR group at 1 year (78.2% versus 59.7%; P=0.03) and at 2 years (77.8% versus 53.2%; P=0.09). Two-year mortality was similar in the 2 groups (TMVR versus GDMT, 36.8% versus 40.8%; hazard ratio, 1.01 [95% CI, 0.62-1.64]; P=0.98). CONCLUSIONS: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for heart failure, and similar mortality compared with GDMT. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04688190 (CHOICE-MI) and NCT01626079 (COAPT).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Pontuação de Propensão , Resultado do Tratamento
12.
J Heart Lung Transplant ; 42(8): 1005-1014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37023840

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) provide circulatory blood pump support for severe heart failure patients. Pump inflow obstructions may lead to stroke and pump malfunction. We aimed to verify in vivo that gradual inflow obstructions, representing prepump thrombosis, are detectable by a pump-attached accelerometer, where the routine use of pump power (PLVAD) is deficient. METHOD: In a porcine model (n = 8), balloon-tipped catheters obstructed HVAD inflow conduits by 34% to 94% in 5 levels. Afterload increases and speed alterations were conducted as controls. We computed nonharmonic amplitudes (NHA) of pump vibrations captured by the accelerometer for the analysis. Changes in NHA and PLVAD were tested by a pairwise nonparametric statistical test. Detection sensitivities and specificities were investigated by receiver operating characteristics with areas under the curves (AUC). RESULTS: NHA remained marginally affected during control interventions, unlike PLVAD. NHA elevated during obstructions within 52-83%, while mass pendulation was most pronounced. Meanwhile, PLVAD changed far less. Increased pump speeds tended to amplify the NHA elevations. The corresponding AUC was 0.85-1.00 for NHA and 0.35-0.73 for PLVAD. CONCLUSION: Elevated NHA provides a reliable indication of subclinical gradual inflow obstructions. The accelerometer can potentially supplement PLVAD for earlier warnings and localization of pump.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Suínos , Animais , Coração Auxiliar/efeitos adversos , Trombose/diagnóstico , Curva ROC , Acelerometria , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/diagnóstico
13.
AsiaIntervention ; 9(1): 78-86, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36936096

RESUMO

Background: A comparison of 30-day and 1-year clinical outcomes in patients with pre-existing left ventricular (LV) dysfunction undergoing transcatheter mitral valve edge-to-edge repair (TEER) or transcatheter transapical mitral valve replacement (TMVR) has not previously been reported. Aims: We aimed to compare 30-day and 1-year rates of all-cause and cardiovascular mortality as well as rehospitalisation for heart failure (HFH). Methods: All patients with severe (≥3+) symptomatic mitral regurgitation (MR) and an LV ejection fraction ≤50% who underwent TEER or TMVR over a 5-year period were evaluated. Results: Ninety-six patients (50 TEER, age 80±9 years, 70% secondary MR and 46 TMVR, age 72±9 years, 91% secondary MR) were studied. Baseline demographic and transthoracic echocardiogram characteristics were well-matched, with the exception of age (TEER 80±9 vs TMVR 72±9; p=0.01). Successful device implantation occurred in 96% of TEER patients and 97.8% of TMVR patients. Ninety-two percent of TEER patients had ≤2+MR predischarge, whilst no TMVR patient had ≥1+MR (p<0.01). No significant difference in the combined endpoint of 30-day all-cause mortality or HFH was observed (p>0.05). At 1 year, freedom from all-cause mortality and HFH was 79.2% across the entire study population but was significantly higher in patients undergoing TEER (TEER: n=45 [90%] hazard ratio 11.26, 95% confidence interval [CI]: 10.59-11.93 vs TMVR: n=39 [67.4%] 95% CI: 10.09-11.33; p=0.008). Conclusions: Despite comparable rates of successful device implantation, MR reduction, and 30-day all-cause mortality/HFH, TEER patients had lower all-cause mortality and HFH rates at 1 year.

14.
Eur J Heart Fail ; 25(3): 399-410, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36883620

RESUMO

AIMS: This study aimed to compare outcomes after transcatheter mitral valve replacement (TMVR) and mitral valve transcatheter edge-to-edge repair (M-TEER) for the treatment of secondary mitral regurgitation (SMR). METHODS AND RESULTS: The CHOICE-MI registry included 262 patients with SMR treated with TMVR between 2014 and 2022. The EuroSMR registry included 1065 patients with SMR treated with M-TEER between 2014 and 2019. Propensity score (PS) matching was performed for 12 demographic, clinical and echocardiographic parameters. Echocardiographic, functional and clinical outcomes out to 1 year were compared in the matched cohorts. After PS matching, 235 TMVR patients (75.5 years [70.0, 80.0], 60.2% male, EuroSCORE II 6.3% [interquartile range 3.8, 12.4]) were compared to 411 M-TEER patients (76.7 years [70.1, 80.5], 59.0% male, EuroSCORE II 6.7% [3.9, 12.4]). All-cause mortality was 6.8% after TMVR and 3.8% after M-TEER at 30 days (p = 0.11), and 25.8% after TMVR and 18.9% after M-TEER at 1 year (p = 0.056). No differences in mortality after 1 year were found between both groups in a 30-day landmark analysis (TMVR: 20.4%, M-TEER: 15.8%, p = 0.21). Compared to M-TEER, TMVR resulted in more effective mitral regurgitation (MR) reduction (residual MR ≤1+ at discharge for TMVR vs. M-TEER: 95.8% vs. 68.8%, p < 0.001), and superior symptomatic improvement (New York Heart Association class ≤II at 1 year: 77.8% vs. 64.3%, p = 0.015). CONCLUSION: In this PS-matched comparison between TMVR and M-TEER in patients with severe SMR, TMVR was associated with superior reduction of MR and superior symptomatic improvement. While post-procedural mortality tended to be higher after TMVR, no significant differences in mortality were found beyond 30 days.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Pontuação de Propensão , Resultado do Tratamento , Cateterismo Cardíaco/métodos
15.
Eur J Heart Fail ; 25(6): 890-901, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36519634

RESUMO

Over the past decade, transcatheter mitral valve replacement (TMVR) technologies have evolved with the objective of improving outcomes for patients with severe mitral regurgitation (MR) deemed unsuitable for conventional mitral valve surgery. Although the safety and efficacy of transcatheter edge-to-edge mitral valve repair (TEER) is well-established, there is a sense amongst innovators that a major advantage of TMVR may be to offer a more complete solution for the correction of MR in patients whose complex anatomy means that the likelihood of achieving grade 0 or 1 MR with TEER is low. However, abrupt correction of MR in a poorly prepared left ventricle poses a number of unique haemodynamic challenges, particularly when sudden elimination of regurgitant flow causes a relative increase in left ventricular (LV) afterload. Rapid reduction in LV cavity size following MR elimination may itself result in relative LV outflow tract obstruction (LVOTO), irrespective of the intrinsic risk of LVOTO associated with TMVR. Nevertheless, TMVR on a beating heart affords the opportunity to study real-time invasive cardiac indices in high-risk patients with acute reversal of severe MR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Fatores de Risco , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
16.
Front Med (Lausanne) ; 9: 1055465, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405607

RESUMO

Extrapulmonary infections with Legionella species are rare, but important to acknowledge. We report a case of infective endocarditis (IE) with Legionella bozemanae in a 66-year-old immunocompetent man with an aortic homograft. The diagnosis was made by direct 16S rRNA gene amplification from valve material, confirmed by a targeted Legionella-PCR in serum and the detection of L. bozemanae specific antibodies. To our knowledge, this is the first confirmed case of IE with L. bozemanae as causative pathogen. The infected aortic prosthesis was replaced by a homograft, and the patient was successfully treated with levofloxacin and azithromycin for 6 weeks.

18.
Eur J Heart Fail ; 24(5): 887-898, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35338542

RESUMO

AIMS: Transcatheter mitral valve implantation (TMVI) represents a novel treatment option for patients with mitral regurgitation (MR) unsuitable for established therapies. The CHOICE-MI registry aimed to investigate outcomes of patients undergoing screening for TMVI. METHODS AND RESULTS: From May 2014 to March 2021, patients with MR considered suboptimal candidates for transcatheter edge-to-edge repair (TEER) and at high risk for mitral valve surgery underwent TMVI screening at 26 centres. Characteristics and outcomes were investigated for patients undergoing TMVI and for TMVI-ineligible patients referred to bailout-TEER, high-risk surgery or medical therapy (MT). The primary composite endpoint was all-cause mortality or heart failure hospitalization after 1 year. Among 746 patients included (78.5 years, interquartile range [IQR] 72.0-83.0, EuroSCORE II 4.7% [IQR 2.7-9.7]), 229 patients (30.7%) underwent TMVI with 10 different dedicated devices. At 1 year, residual MR ≤1+ was present in 95.2% and the primary endpoint occurred in 39.2% of patients treated with TMVI. In TMVI-ineligible patients (n = 517, 69.3%), rates of residual MR ≤1+ were 37.2%, 100.0% and 2.4% after bailout-TEER, high-risk surgery and MT, respectively. The primary endpoint at 1 year occurred in 28.8% of patients referred to bailout-TEER, in 42.9% of patients undergoing high-risk surgery and in 47.9% of patients remaining on MT. CONCLUSION: This registry included the largest number of patients treated with TMVI to date. TMVI with 10 dedicated devices resulted in predictable MR elimination and sustained functional improvement at 1 year. In TMVI-ineligible patients, bailout-TEER and high-risk surgery represented reasonable alternatives, while MT was associated with poor clinical and functional outcomes.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Sistema de Registros , Resultado do Tratamento
19.
Eur J Heart Fail ; 24(5): 899-907, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35064722

RESUMO

AIMS: Transcatheter mitral valve implantation (TMVI) is a new treatment option for patients with symptomatic mitral valve (MV) disease. Real-world data have not yet been reported. This study aimed to assess procedural and 30-day outcomes of TMVI in a real-world patient cohort. METHOD AND RESULTS: All consecutive patients undergoing implantation of a transapically delivered self-expanding valve at 26 European centres from January 2020 to April 2021 were included in this retrospective observational registry. Among 108 surgical high-risk patients included (43% female, mean age 75 ± 7 years, mean STS-PROM 7.2 ± 5.3%), 25% was treated for an off-label indication (e.g. previous MV intervention or surgery, mitral stenosis, mitral annular calcification). Patients were highly symptomatic (New York Heart Association [NYHA] functional class III/IV in 86%) and mitral regurgitation (MR) was graded 3+/4+ in 95% (38% primary, 37% secondary, and 25% mixed aetiology). Technical success rate was 96%, and MR reduction to ≤1+ was achieved in all patients with successful implantation. There were two procedural deaths and 30-day all-cause mortality was 12%. At early clinical follow-up, MR reduction was sustained and there were significant reductions of pulmonary pressure (systolic pulmonary artery pressure 52 vs. 42 mmHg, p < 0.001), and tricuspid regurgitation severity (p = 0.013). Heart failure symptoms improved significantly (73% in NYHA class I/II, p < 0.001). Procedural success rate according to MVARC criteria was 80% and was not different in patients treated for an off-label indication (74% vs. 81% for off- vs. on-label, p = 0.41). CONCLUSION: In a real-world patient population, TMVI has a high technical and procedural success rate with efficient and durable MR reduction and symptomatic improvement.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Insuficiência Cardíaca/etiologia , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA