RESUMO
INTRODUCTION: The transition from paediatric to adult diabetes care (TPA) of children/adolescents with type 1 diabetes (T1D) represents a unique challenge and remains a critical phase in the T1D care pathway. This study aims to describe and understand the experience of the transition process from a participant's perspective in young adults who are living in France with T1D and to measure their satisfaction. METHODS: An online questionnaire was presented to people with T1D in France on a global online participant community platform. The questionnaire was developed by a scientific committee including paediatric and adult diabetologists and refined by a group of participants. Thematic qualitative analysis was performed on the responses. RESULTS: A total of 104 respondents were included in the survey (mean age 24.4 years [95% CI 23.8-25.0]; 61.5% female). The mean age at the time of transition was 18.4 years (95% CI 17.8-18.9), and 56% of respondents had their first adult diabetology follow-up in the same institution. During TPA, of the 76 participants who experienced personal issues, 74% experienced at least one issue with their diabetes management in the months following the transition. In the following months, 61% experienced new or unexpected problems in monitoring their diabetes after transition and 44% reported unusual glycaemic imbalances, including hypoglycaemia (8%) and hyperglycaemia (9%) requiring hospitalisation. Presence of personal issues during TPA was significantly associated with occurrence of problems with diabetes management or glycaemic imbalance. Three factors identified for a successful transition were (i) early meeting with the 'adult' diabetes care team, (ii) letting the participants choose the right age to leave paediatric clinic and (iii) having good diabetes control at the beginning of the TPA process. CONCLUSION: Most young adults with T1D report experiencing issues around TPA with significant consequences on their disease management. Hence, it is necessary to identify these issues to better support them and improve diabetes management during this phase.
RESUMO
OBJECTIVE: To evaluate the impact of prolonged hybrid closed loop (HCL) use in children with type 1 diabetes (T1D) on glucose control and BMI throughout pubertal progression. RESEARCH DESIGN AND METHODS: We used a prospective multicenter extension study following the Free-Life Kid AP (FLKAP) HCL trial. The 9-month previously reported FLKAP trial included 119 prepubertal children (aged 6-12 years). During the extension study, participants could continue to use HCL for 30 months (M9 to M39). HbA1c values were collected every 3 months up to M39, while continuous glucose monitoring metrics, BMI z scores, and Tanner stages were collected up to M24. Noninferiority tests were performed to assess parameter sustainability over time. RESULTS: One hundred seventeen children completed the extension study, with mean age 10.1 years (minimum to maximum, 6.8-14.0) at the beginning. Improvement of HbA1c obtained in the FLKAP trial was significantly sustained during extension (median [interquartile range], M9 7.0% [6.8-7.4], and M39 7.0% [6.6-7.4], P < 0.0001 for noninferiority test) and did not differ between children who entered puberty at M24 (Tanner stage ≥2; 54% of the patients) and patients who remained prepubertal. BMI z score also remained stable (M9 0.41 [-0.29 to 1.13] and M24 0.48 [-0.11 to 1.13], P < 0.0001, for noninferiority test). No severe hypoglycemia and one ketoacidosis episode not related to the HCL system occurred. CONCLUSIONS: Prolonged use of HCL can safely and effectively mitigate impairment of glucose control usually associated with pubertal progression without impact on BMI in children with T1D.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Puberdade , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Criança , Feminino , Masculino , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Estudos Prospectivos , Adolescente , Controle Glicêmico/métodos , Hemoglobinas Glicadas/metabolismo , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Insulina/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Índice de Massa CorporalRESUMO
Familial Renal Glucosuria (FRG) is a co-dominantly inherited trait characterized by orthoglycaemic glucosuria. From 2003 to 2015 we have reported several cohorts validating SLC5A2 (16p11.2), encoding SGLT2 (Na+/glucose cotransporter family member 2), as the gene responsible for FRG. The aim of this work was to validate the variants identified in our extended FRG cohort of published, as well more recent unreported cases, according to the ACMG-AMP 2015 criteria. Forty-six variants were evaluated, including 16 novel alleles first described in this study. All are rare, ultra-rare or absent from population databases and most are missense changes. According to the ACMG-AMP standards, only 74% of the variants were classified as P/LP. The lack of descriptions of unrelated patients with similar variants or failing to test additional affected family members, averted a conclusion for pathogenicity in the alleles that scored VUS, highlighting the importance of both family testing and variant reporting. Finally, the cryo-EM structure of the hSGLT2-MAP17 complex in the empagliflozin-bound state improved the ACMG-AMP pathogenicity score by identifying critical/functional protein domains.
Assuntos
Glicosúria Renal , Humanos , Glicosúria Renal/genética , Glicosúria Renal/metabolismo , Transportador 2 de Glucose-Sódio/genética , Transportador 2 de Glucose-Sódio/química , Transportador 2 de Glucose-Sódio/metabolismo , Alelos , Glucosídeos , LinhagemRESUMO
Background: It is unclear whether hybrid closed-loop (HCL) therapy attenuates the metabolic impact of missed or suboptimal meal insulin bolus compared with sensor-augmented pump (SAP) therapy in children with type 1 diabetes in free-living conditions. Methods: This is an ancillary study from a multicenter randomized controlled trial that compared 24/7 HCL with evening and night (E/N) HCL for 36 weeks in children between 6 and 12 years old. In the present study, the 60 children from the E/N arm underwent a SAP phase, an E/N HCL for 18 weeks, then a 24/7 phase for 18 weeks, extended for 36 more weeks. The last 28-30 days of each of the four phases were analyzed according to meal bolus management (cumulated 6817 days). The primary endpoint was the percentage of time that the sensor glucose was in the target range (TIR, 70-180 mg/dL) according to the number of missed boluses per day. Findings: TIR was 54% ± 10% with SAP, 63% ± 7% with E/N HCL, and steadily 67% ± 7% with 24/7 HCL. From the SAP phase to 72 weeks of HCL, the percentage of days with at least one missed meal bolus increased from 12% to 22%. Estimated marginal (EM) mean TIR when no bolus was missed was 54% (95% confidence intervals [CI] 53-56) in SAP and it was 13% higher (95% CI 11-15) in the 24/7 HCL phase. EM mean TIR with 1 and ≥2 missed boluses/day was 49.5% (95% CI 46-52) and 45% (95% CI 39-51) in SAP, and it was 15% (95% CI 14-16) and 17% higher (95% CI 6-28), respectively, in the 24/7 HCL phase (P < 0.05 for all comparisons vs. SAP). Interpretation: HCL persistently improves glycemic control compared with SAP, even in case of meal bolus omission. ClinicalTrials.gov (NCT03739099).
Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Glicemia/metabolismo , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Automonitorização da GlicemiaRESUMO
AIM: To assess the safety and efficacy of hybrid closed-loop (HCL) insulin delivery 24/7 versus only evening and night (E/N), and on extended 24/7 use, in free-living children with type 1 diabetes. MATERIALS AND METHODS: Prepubertal children (n = 122; 49 females/73 males; age, 8.6 ± 1.6 years; diabetes duration, 5.2 ± 2.3 years; insulin pump use, 4.6 ± 2.5 years; HbA1c 7.7% ± 0.7%/61 ± 5 mmol/mol) from four centres were randomized for 24/7 versus E/N activation of the Tandem Control-IQ system for 18 weeks. Afterwards, all children used the activated system 24/7 for 18 more weeks. The primary outcome was the percentage of time spent in the 70-180 mg/dL glucose range (TIR). RESULTS: HCL was active 94.1% and 51.1% of the time in the 24/7 and E/N modes, respectively. TIR from baseline increased more in the 24/7 versus the E/N mode (52.9% ± 9.5% to 67.3% ± 5.6% [+14.4%, 95% CI 12.4%-16.7%] vs. 55.1% ± 10.8% to 64.7% ± 7.0% [+9.6%, 95% CI 7.4%-11.6%]; P = .001). Mean percentage time below range was similarly reduced, from 4.2% and 4.6% to 2.7%, and the mean percentage time above range decreased more in the 24/7 mode (41.9% to 30.0% [-11.9%, 95% CI 9.7%-14.6%] vs. 39.8% to 32.6% [-7.2%, 95% CI 5.0%-9.9%]; P = .007). TIR increased through the whole range of baseline levels and always more with 24/7 use. The results were maintained during the extension phase in those initially on 24/7 use and improved in those with initial E/N use up to those with 24/7 use. Neither ketoacidosis nor severe hypoglycaemia occurred. CONCLUSIONS: The current study shows the safety and efficacy of the Tandem Control-IQ system in free-living children with type 1 diabetes for both E/N and 24/7 use; 24/7 use shows better outcomes, sustained for up to 36 weeks with no safety issues.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , MasculinoRESUMO
OBJECTIVES: The objective of this multicenter cross-sectional study was to determine predictors of poor glycaemic control in children with type 1 diabetes mellitus (T1DM), particularly with respect to socioeconomic status (SES). METHODS: Our study population consisted of 1154 children who attended T1DM follow-up consultation with a pediatric diabetes specialist. Clinical and demographic data were retrieved retrospectively from patients' records. Individual deprivation was defined by an EPICES (Evaluation of the Deprivation and Inequalities of Health in Healthcare Centers) score ≥ 30. Patients were assigned to quintiles of the European Deprivation Index (EDI) based on their area deprivation scores. We used multivariable linear regression models to detect potential associations between glycaemic control and indicators of low SES. RESULTS: In total, 33% (n = 376) of patients had an EPICES score ≥ 30 and 23% (n = 268) were in the 5th EDI quintile. Multivariable linear regression analysis showed that poor glycaemic control was associated with both individual (ß 0.38; 95%CI 0.26-0.5; p < 0.001) and area deprivation (ß 0.26; 95%CI 0.08-0.43; p = 0.004). Demographic factors, body mass index (BMI) and insulin regimen were also independently associated with poor glycaemic control (p < 0.001). Interestingly, access to diabetes technologies was not related to SES or either glycaemic control. CONCLUSION: Low SES is associated with a higher risk of poor glycaemic control, independently of insulin regimen. BMI, age at the time of consultation, duration of diabetes, and insulin regimen. Also have an impact on HbA1c. These parameters need to be considered when developing novel treatment strategies for children with T1DM to better target at-risk patients.
Assuntos
Carência Cultural , Diabetes Mellitus Tipo 1/epidemiologia , Controle Glicêmico , Adolescente , Glicemia/metabolismo , Criança , Pré-Escolar , Estudos Transversais , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/terapia , Feminino , França/epidemiologia , Hemoglobinas Glicadas/metabolismo , Controle Glicêmico/psicologia , Controle Glicêmico/estatística & dados numéricos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Classe Social , Fatores Socioeconômicos , Adulto JovemRESUMO
AIM: To compare the efficacy of three strategies for real-time continuous glucose monitoring (RT-CGM) over 12 months in children and adolescents with type 1 diabetes. METHODS: A French multicenter trial (NCT00949221) with a randomized, controlled, prospective, open, and parallel-group design was conducted. After 3 months of RT-CGM, patients were allocated to one of three groups: return to self-monitoring of blood glucose, continuous CGM (80% of the time), or discontinuous CGM (40% of the time). The primary outcome was hemoglobin A1c (HbA1c) levels from 3 to 12 months. The secondary outcomes were acute metabolic events, hypoglycemia, satisfaction with CGM and cost. RESULTS: We included 151 subjects, aged 2 to 17 years, with a mean HbA1c level of 8.5% (SD0.7; 69 mmol/mol). The longitudinal change in HbA1c levels was similar in all three groups, at 3, 6, 9 and 12 months. The medical secondary endpoints did not differ between groups. The rate of severe hypoglycemia was significantly lower than that for the pretreatment year for the entire study population. Subjects reported consistent use and good tolerance of the device, regardless of age or insulin treatment. The use of full-time RT-CGM for 3 months costs the national medical insurance system 2629 per patient. CONCLUSION: None of the three long-term RT-CGM strategies evaluated in pediatric type 1 diabetes was superior to the others in terms of HbA1c levels. CGM-use for 3 months decreased rates of severe hypoglycemia. Our results confirm the feasibility of long-term RT-CGM-use and the need to improve educational support for patients and caregivers.
Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Adolescente , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Automonitorização da Glicemia/normas , Calibragem , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/epidemiologia , Equipamentos e Provisões/normas , Feminino , França/epidemiologia , Humanos , Masculino , Prognóstico , Fatores de TempoRESUMO
This randomized control trial investigated glucose control with closed-loop (CL) versus threshold-low-glucose-suspend (TLGS) insulin pump delivery in pre-pubertal children with type 1 diabetes in supervised hotel conditions. The patients [n = 24, age range: 7-12, HbA1c: 7.5 ± 0.5% (58 ± 5 mmol/mol)] and their parents were admitted twice at a 3-week interval. CL control to range or TLGS set at 3.9 mmoL/L were assessed for 48 hour in randomized order. Admissions included three meals and one snack, and physical exercise. Meal boluses followed individual insulin/carb ratios. While overnight (22:00-08:00) per cent continuous glucose monitoring (CGM) time below 3.9 mmol/L (primary outcome) was similar, time in ranges 3.9 to 10.0 and 3.9 to 7.8 mmoL/L and mean CGM were all significantly improved with CL (P < 0.001). These results were confirmed over the whole 48 hour. Disconnections between devices and limited accuracy of glucose sensors in the hypoglycaemic range appeared as limiting factors for optimal control. CL mode was well accepted while fear of hypoglycaemia was unchanged. CL did not minimize nocturnal hypoglycaemia exposure but improved time in target range compared to TLGS. Although safe and well-accepted, CL systems would benefit from more integrated devices.
Assuntos
Algoritmos , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Glicemia/análise , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/farmacologia , Hipoglicemiantes/uso terapêuticoAssuntos
Anormalidades Múltiplas/tratamento farmacológico , Anti-Hipertensivos/efeitos adversos , Diazóxido/efeitos adversos , Face/anormalidades , Doenças Hematológicas/tratamento farmacológico , Derrame Pericárdico/induzido quimicamente , Derrame Pericárdico/patologia , Doenças Vestibulares/tratamento farmacológico , Anormalidades Múltiplas/patologia , Face/patologia , Feminino , Doenças Hematológicas/patologia , Humanos , Lactente , Prognóstico , Medição de Risco , Doenças Vestibulares/patologiaRESUMO
AIMS: To understand the opinions of children with type 1 diabetes about their everyday use of flash glucose monitoring. (FGM). METHODS: Children with type 1 diabetes using the FreeStyle Libre® FGM system and/or their parents were surveyed in several French medical centers between December 2016 and June 2017, regardless of their treatment regimen and metabolic control. RESULTS: Of the 347 patients recruited, 79.5% had been using the sensor for more than three months (average usage time: 285 days). The main reported motivations for initiating this type of monitoring were to avoid finger prick pain (for 85.9% of patients) and to allow parents to check nocturnal glucose levels (60.8%). Two-thirds of respondents experienced difficulties, mainly the sensor falling off (47.6%), measurement discrepancies (25.1%) and cutaneous reactions (22.2%); 89.5% changed their habits: 70.6% took more scans, 37.2% corrected their hyperglycemia more promptly, and 37.5% used trends to adjust their insulin dosage. About one-third of the study group (35.1%) experienced lower HbA1c levels, and two thirds (67.1%) were satisfied with the device. CONCLUSIONS: Our results show that FGM is a widely accepted option for self-monitoring diabetes, but that specific training is required to improve its use for insulin dosage adjustment and metabolic results.
Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/diagnóstico , Satisfação do Paciente , Adolescente , Comportamento do Adolescente , Fatores Etários , Biomarcadores/sangue , Criança , Comportamento Infantil , Pré-Escolar , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Desenho de Equipamento , Feminino , França , Hemoglobinas Glicadas , Hábitos , Pesquisas sobre Atenção à Saúde , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Hipoglicemiantes/administração & dosagem , Lactente , Recém-Nascido , Insulina/administração & dosagem , Masculino , Motivação , Pais/psicologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de TempoRESUMO
Mycoplasma pneumoniae-associated nephritis has been reported in children with various pathological findings. It nevertheless remains an uncommon disease and, within this clinical context, endo-and extracapillary glomerulonephritis in a child has never been described. We report here a case of a 3-year-old girl diagnosed with severe crescentic glomerulonephritis associated with M. pneumoniae infection who presented with nephrotic syndrome and impaired renal function. The serum C3 complement level was initially low but returned to normal after 1 month. Two courses of three methylprednisolone pulses were administered in association with plasmapheresis and, secondarily, mycophenolate mophetil. This treatment regimen led to disease remission and a favorable renal outcome at the 6-month follow-up. However, the treatment guidelines in this situation remain debatable.
Assuntos
Glomerulonefrite/terapia , Imunossupressores/administração & dosagem , Metilprednisolona/administração & dosagem , Ácido Micofenólico/análogos & derivados , Mycoplasma pneumoniae/isolamento & purificação , Plasmaferese , Pneumonia por Mycoplasma/complicações , Biomarcadores/sangue , Pré-Escolar , Convertases de Complemento C3-C5/metabolismo , Esquema de Medicação , Feminino , Glomerulonefrite/imunologia , Glomerulonefrite/microbiologia , Humanos , Ácido Micofenólico/administração & dosagem , Síndrome Nefrótica/microbiologia , Síndrome Nefrótica/terapia , Proteinúria/microbiologia , Proteinúria/terapia , Pulsoterapia , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do TratamentoRESUMO
Premature newborns are particularly vulnerable to iatrogenic hypothyroidism due to iodine exposure, usually through skin absorption of iodine-containing disinfectants or intravenous administration of iodinated contrast agents. We report here a case of severe iatrogenic hypothyroidism with goiter and cholestasis, discovered six weeks after a contrast enema using sodium ioxitalamate, an iodinated contrast agent. Prematurity, intrauterine growth retardation, and enteral feeding intolerance could explain why this complication occurred after contrast enema. Our observations suggest that indications of contrast enema in neonates need to be carefully considered, and when necessary, thyroid function should be monitored, especially in very premature infants.