Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
3.
Am J Cardiol ; 205: 234-240, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37611416

RESUMO

Periprocedural systemic embolism is a well-documented complication of transcatheter aortic valve replacement (TAVR). Although the most focus was given to cerebral embolism (which remains unpredictable, difficult to prevent, and a source of increased morbidity and mortality after TAVR), coronary embolism remains less investigated and potentially overlooked. This study provides a case series of 3 patients diagnosed with coronary embolism after TAVR in our institution over a 2-year period (3 of 297 cases, 1%) and a systematic literature review (4 studies; 19 case reports). Overall, coronary embolism associated with TAVR is frequently characterized by proximal vessel occlusion causing ST-elevation myocardial infarction and hemodynamic instability with lower mortality in the acute phase as compared with late coronary embolism. However, it often presents with distal vessel occlusion and minor symptoms that may be overlooked in the periprocedural period. In conclusion, we suggest that TAVR-associated coronary embolism has a much higher prevalence than previously documented. Further studies are warranted to properly assess the prevalence and impact of this phenomenon.


Assuntos
Doença da Artéria Coronariana , Embolia , Embolia Intracraniana , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Embolia/epidemiologia , Embolia/etiologia
6.
JACC Case Rep ; 5: 101691, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36523949

RESUMO

Aortic perforation is a rare complication of transcatheter aortic valve replacement associated with grim outcomes. Tortuous and calcified aortas increase the risk of aortic trauma and perforation. We report a case in which, despite massive thoracic bleeding, avoidance of thoracic aortic surgery resulted in clinical recovery. (Level of Difficulty: Intermediate.).

7.
Int J Mol Sci ; 22(10)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068392

RESUMO

Myocardial infarction (MI) remains the leading cause of death in the western world. Despite advancements in interventional revascularization technologies, many patients are not candidates for them due to comorbidities or lack of local resources. Non-invasive approaches to accelerate revascularization within ischemic tissues through angiogenesis by providing Vascular Endothelial Growth Factor (VEGF) in protein or gene form has been effective in animal models but not in humans likely due to its short half-life and systemic toxicity. Here, we tested the hypothesis that PR1P, a small VEGF binding peptide that we developed, which stabilizes and upregulates endogenous VEGF, could be used to improve outcome from MI in rodents. To test this hypothesis, we induced MI in mice and rats via left coronary artery ligation and then treated animals with every other day intraperitoneal PR1P or scrambled peptide for 14 days. Hemodynamic monitoring and echocardiography in mice and echocardiography in rats at 14 days showed PR1P significantly improved multiple functional markers of heart function, including stroke volume and cardiac output. Furthermore, molecular biology and histological analyses of tissue samples showed that systemic PR1P targeted, stabilized and upregulated endogenous VEGF within ischemic myocardium. We conclude that PR1P is a potential non-invasive candidate therapeutic for MI.


Assuntos
Antígeno AC133/metabolismo , Modelos Animais de Doenças , Isquemia/complicações , Infarto do Miocárdio/prevenção & controle , Neovascularização Fisiológica/efeitos dos fármacos , Fragmentos de Peptídeos/farmacologia , Fator A de Crescimento do Endotélio Vascular/metabolismo , Animais , Feminino , Isquemia/metabolismo , Isquemia/patologia , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Ratos , Ratos Sprague-Dawley , Transdução de Sinais , Fator A de Crescimento do Endotélio Vascular/genética , Função Ventricular Esquerda/efeitos dos fármacos
8.
Harefuah ; 160(4): 205-209, 2021 Apr.
Artigo em Hebraico | MEDLINE | ID: mdl-33899367

RESUMO

INTRODUCTION: Resistant hypertension is a commonplace condition among patients referred to specialty hypertension clinics, which is associated with increased morbidity and mortality. Refractory hypertension however is a rare extreme subtype of resistant hypertension in which blood pressure is uncontrolled despite treatment with five antihypertensive drug classes including a diuretic and a mineralocorticoid receptor antagonist, and is associated with even worse prognosis. We herein describe a 40-year-old woman with severe refractory hypertension and target organ damage for who percutaneous renal sympathetic denervation successfully reduced blood pressure to normal levels and alleviated chronic headaches. Renal denervation should be considered in patients with refractory hypertension, especially when sympathetic over-activity is suspected.


Assuntos
Hipertensão , Adulto , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Feminino , Humanos , Hipertensão/tratamento farmacológico , Rim , Simpatectomia , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 97(6): E868-E874, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865879

RESUMO

INTRODUCTION: Percutaneous mitral valve repair (PMVR), such as MitraClip, is performed on high-risk patients and involves hemodynamic alternations that may cause acute kidney injury (AKI). We aimed to evaluate the incidence of AKI, predictors for developing AKI and the correlation with mortality after MitraClip. METHODS: We performed a retrospective analysis of collected data from patients who underwent PMVR in two tertiary medical centers in Israel to identify factors associated with AKI. RESULTS: The study population included 163 patients. The median age was 77 years; 60.7% of patients were male. The median eGFR significantly decreased post-procedure from 49 (35-72) to 47.8 (31-65.5) ml/min/1.73 m2 (p < .001). Forty-seven patients (29%) developed AKI. None of the patients who developed AKI required hemodialysis. Predictors of AKI included: baseline eGFR ≤30 ml/min/1.73 m2 , severity of residual MR, TMPG>5 mmHg, diuretic use, and re-do procedures. Among the patients who developed AKI there was an improvement in kidney function during follow-up, and creatinine levels significantly decreased from a peak mean creatinine of 179.5 (143-252) mmol/l to 136 (92-174) mmol/l (p < .001). However, 19% (9 out of 47) of patients experienced partial recovery and their creatinine level, when compared to their baseline, remained elevated. One-year survival showed a trend for increased mortality among patients who developed AKI (86.2% vs. 80.9%, p = .4), and patients who developed AKI that persisted had increased 1-year mortality compared with patients that had recovered their kidney function (86.8% vs. 55.6%, p = .01). CONCLUSION: The incidence of AKI after MitraClip is high. AKI is reversible in most patients; however, the persistence of kidney injury is associated with increased 1-year mortality.


Assuntos
Injúria Renal Aguda , Insuficiência da Valva Mitral , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Idoso , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 25: 1-8, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33168433

RESUMO

Treatment of lesions in small coronary vessels is associated with an increased risk of adverse cardiovascular events after percutaneous coronary intervention (PCI).We aimed to evaluate the outcomes of patients undergoing small-vessel PCI in the BIONICS trial and to identify predictors of stent failure. 1910 patients were randomized to treatment with the EluNIR™ ridaforolimus-eluting stent (RES) or Resolute™ zotarolimus-eluting stent (ZES). Small vessels were defined as reference vessel diameters (RVD) ≤2.5 mm. A Cox proportional hazards model was used to identify predictors of target lesion failure (TLF) through 2 years. Patients undergoing small vessel disease PCI had a higher frequency of diabetes, prior myocardial infarction (MI), and prior PCI. 2 year TLF was higher among patients with small vessels (9.7% vs. 5.9%, HR 1.7 [95% CI 1.22-2.37], p < 0.01), driven by increased rates of target vessel-MI and target lesion revascularization (TLR). Stent thrombosis at 2 years was higher among patients with small vessel disease (1.4% vs. 0.3%, HR 5.25 [95% CI 1.47-18.8], p < 0.01). 2 year TLF rates were similar in the RES and ZES patient groups (Pinteraction 0.86). In conclusion, patients undergoing PCI in small vessels have significantly worse outcomes despite the use of contemporary stents.


Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Biônica , Fármacos Cardiovasculares/efeitos adversos , Humanos , Incidência , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
ESC Heart Fail ; 7(6): 4071-4079, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33085190

RESUMO

AIMS: We evaluated the impact of MitraClip on systolic pulmonary artery pressure (sPAP) and the effects of baseline sPAP on outcomes. METHODS AND RESULTS: In a cohort of patients who underwent MitraClip implantation, three groups were defined according to pre-procedure sPAP levels. Clinical and echocardiographic data were compared. The study included 177 patients: 59 had severe pulmonary hypertension (PHT), 96 had mild to moderate PHT, and 22 had no PHT. In patients with pre-existing severe PHT, sPAP was reduced from 70.8 ± 9.2 to 56.8 ± 13.7 mmHg (P < 0.001), sPAP remained unchanged in patients with mild to moderate PHT but was significantly increased from 30.8 ± 4.3 to 38.6 ± 8.3 mmHg in the no-PHT group (P < 0.001). Improvement of sPAP was observed in 77% of severe PHT group, while worsening of sPAP was more common among patients with no-PHT [57% compared with 33% among the mild to moderate PHT and 7% in the severe PHT group, respectively, (P < 0.001)]. One year survival was similar among the study groups. CONCLUSIONS: MitraClip decreases PHT among patients with severe PHT. A concerning finding is that most patients with no-PHT increase their sPAP.

12.
JACC Cardiovasc Interv ; 13(18): 2091-2096, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32972568

RESUMO

OBJECTIVES: This study sought to report short-term results of safety, performance, and efficacy of the Mistral device first-in-human study in patients suffering from severe functional tricuspid insufficiency. BACKGROUND: Patients who suffer from severe tricuspid regurgitation (TR) and who are at high surgical risk have no standard care therapy. Therefore, minimally invasive and safer methods are sought. The Mistral device is an investigational spiral-shaped device intended for percutaneous transcatheter repair. The Mistral device approximates the tricuspid leaflets by grasping together the chordae tendineae of the tricuspid valve. METHODS: Seven patients (4 women; mean age 73.14 ± 7.4 years) with severe (n = 5) and massive (n = 2) symptomatic TR and high surgical risk underwent Mistral tricuspid repair under transesophageal echocardiography guidance. RESULTS: Mistral was successfully implanted in all cases with a single device deployed in 6 patients, with 2 devices deployed in 1 patient. No procedural or 30-day adverse events occurred. TR was reduced by at least 1 grade in all patients. Effective regurgitant orifice area was reduced from median 0.52 cm2 (interquartile range [IQR]: 0.40 to 0.60 cm2) at baseline to 0.15 cm2 (IQR: 0.14 to 0.21 cm2) at 30 days post-procedure (p < 0.01), vena contracta width was reduced from 0.95 cm (IQR: 0.81 to 1.16 cm) to 0.62 cm (IQR: 0.52 to 0.67 cm) (p < 0.05), and regurgitant volume decreased from 49.4 ml/beat (IQR: 45.2 to 57.7 ml/beat) to 19.7 ml/beat (IQR: 12.4 to 23.9 ml/beat) (p < 0.01). Right ventricular fractional area change improved from 27.0% (IQR: 21.3% to 33.5%) at baseline to 38.5% (IQR: 29.0% to 47.1%) at 30-day follow-up (p < 0.05). Significant improvements in New York Heart Association functional class, Kansas City Cardiomyopathy Questionnaire score, and 6-min walk test were observed at 30 days. CONCLUSIONS: Tricuspid valve repair with the Mistral device appears safe and leads to 30-day reduction of tricuspid insufficiency and improvement of right ventricular function and exercise capacity.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Masculino , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
14.
J Thromb Thrombolysis ; 47(4): 550-557, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30689152

RESUMO

Direct oral anticoagulants (DOACs) are commonly administered at a level that is lower than that recommended by dose reduction criteria. This raises concern regarding the adequacy of anticoagulation achieved. To evaluate the relationship between inappropriate dosing and DOAC levels. Medical records of atrial fibrillation patients who underwent DOAC level testing during 2013-2017 were reviewed. The primary outcomes were drug levels under and above the expected steady-state range, and in the lowest and highest quartiles. Of 143 patients who underwent DOAC measurements, only 87 (60.8%) received the appropriate dose. Levels under the expected range and in the lowest quartile were found in 11.9% and 15.0% of patients treated with appropriate dosing compared to 21% and 41.5% of patients treated with inappropriately low dose. DOAC levels were above the expected range and in the highest quartile in 23.8% and 32.5% of patients treated with the appropriate dose compared to 7.1% and 9.4% treated with inappropriately low dose. In multivariate analysis, the administration of an appropriate DOAC dose was associated with a lower rate of DOAC in the lowest level (adjusted odds ratio [95% CI] 0.30 (0.12, 0.76), P = 0.011). On the other hand, appropriate dose was associated with drug levels in the highest quartile (odds ratio [95% CI] 3.77 (0.12, 0.76), P = 0.011). Treatment with inappropriately low DOAC dosing compared to appropriate dose is associated with lower DOAC levels. However, among those treated with appropriate dosing, a higher proportion had high DOAC levels above the expected range.


Assuntos
Anticoagulantes , Fibrilação Atrial , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Fibrilação Atrial/sangue , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Masculino , Prontuários Médicos
15.
Catheter Cardiovasc Interv ; 92(3): 574-582, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29602220

RESUMO

OBJECTIVES: To evaluate the role mitral regurgitation (MR) etiology and severity play in outcomes for patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Multiple prior studies have investigated the influence of MR severity on outcomes for patients undergoing TAVR. Less has been published regarding the effects of MR etiology on outcomes, including its impact on heart failure hospitalization. METHODS: Two hundred and seventy patients undergoing TAVR at 2 hospitals were enrolled. Each patient had a baseline and follow-up (within 30 days of TAVR) echocardiogram that was analyzed. MR was graded as none, mild, moderate, or severe, as well as functional or degenerative. We compared patient outcomes, including death and heart failure hospitalization, among none-mild MR, moderate-severe functional MR, and moderate-severe degenerative MR groups. RESULTS: Two hundred and seventy patients underwent TAVR, reducing mean aortic valve gradients from 45 ± 15 mm Hg to 9 ± 4 mm Hg. On multivariable analysis, only patients with moderate-severe degenerative MR had decreased survival free of death or CHF hospitalization compared to those with none-mild MR (P = .011). Subanalysis showed patients with moderate-severe degenerative MR were more likely to be hospitalized for heart failure at 2 years compared to those with moderate-severe functional MR (P = .02). Patients with moderate-severe degenerative MR were also less likely to have improvement in MR severity at follow up (P = .01). CONCLUSIONS: Special consideration should be given to patients with moderate-severe degenerative MR undergoing TAVR. As transcatheter approaches for mitral valve repair and replacement continue to evolve, moderate-severe degenerative MR patients may benefit from consideration of double valve intervention.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Georgia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Israel , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Readmissão do Paciente , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
Harefuah ; 157(3): 167-169, 2018 03.
Artigo em Hebraico | MEDLINE | ID: mdl-29582947

RESUMO

INTRODUCTION: Aortic stenosis is the most common significant valvular disease in the western world. These patients are treated operatively unless they are at high operative risk or inoperable. During the last decade an alternative approach has evolved - transcatheter aortic valve implantation (TAVI). This method was shown to be at least as effective and safe as the operative one. However, very little data exists on long term follow-up (5 years and above), especially regarding valve durability and patient survival. OBJECTIVES: To present a long term follow-up on patients who underwent transcutaneous self-expandable aortic valve implantation in our department between the years 2008-2011. METHODS: In September 2008 the first CoreValve implantation was performed in Israel at Hadassah Medical Center. All records of patients who were transplanted between 9.2008 and 10.2011 were reviewed. The function of the valve early after the procedure was compared to its function at the end of the follow-up period. RESULTS: A total of 38 patients (out of 71) survived at least 54 months, of them, 19 have an echocardiography examination at the end of the follow-up period. In all patients the implanted valve was found to function well at the end of the follow-up period, without significant stenosis or paravalvular leak. In fact, in approximately half of these patients, the degree of paravalvular leak decreased during the follow-up period. DISCUSSION: On long term (5 years) follow-up of patients who were implanted with the self-expandable aortic valve (CoreValve), no deterioration of the valve was observed. In fact, in approximately half of the patients, a decrease in the severity of the paravalvular leak was demonstrated.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica , Seguimentos , Humanos , Israel , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
17.
Drug Deliv Transl Res ; 8(4): 945-953, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28656488

RESUMO

The innate immunity system plays a critical role in vascular repair and restenosis development. Liposomes encapsulating bisphosphonates (LipBPs), but not free BPs, suppress neointima formation following vascular injury mediated in part by monocytes. The objective of this study was to elucidate the role of monocyte subpopulations on vascular healing following LipBP treatment. The potency- and dose-dependent treatment effect of clodronate (CLOD) and alendronate (ALN) liposomes on restenosis inhibition, total monocyte depletion, and monocytes subpopulation was studied. Rats subjected to carotid injury were treated by a single IV injection of LipBPs at the time of injury. Low- and high-dose LipALN treatment (3 and 10 mg/kg, respectively) resulted in a dose-dependent effect on restenosis development after 30 days. Both doses of LipALN resulted in a dose-dependent inhibition of restenosis, but only high dose of LipALN depleted monocytes (-60.1 ± 4.4%, 48 h post injury). Although LipCLOD treatment (at an equivalent potency to 3 mg/kg alendronate) significantly reduced monocyte levels (72.1 ± 6%), no restenosis inhibition was observed. The major finding of this study is the correlation found between monocyte subclasses and restenosis inhibition. Non-classical monocyte (NCM) levels were found higher in LipALN-treated rats, but lower in LipCLOD-treated rats, 24 h after injury and treatment. We suggest that the inhibition of circulating monocyte subpopulations is the predominant mechanism by which LipBPs prevent restenosis. The effect of LipBP treatment on the monocyte subpopulation correlates with the dose and potency of LipBPs.


Assuntos
Alendronato/administração & dosagem , Lesões das Artérias Carótidas/tratamento farmacológico , Ácido Clodrônico/administração & dosagem , Reestenose Coronária/prevenção & controle , Monócitos/imunologia , Lesões do Sistema Vascular/tratamento farmacológico , Animais , Lesões das Artérias Carótidas/imunologia , Lipossomos , Masculino , Ratos , Lesões do Sistema Vascular/imunologia
18.
JACC Cardiovasc Interv ; 10(14): 1428-1435, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28728656

RESUMO

OBJECTIVES: The study sought to examine the effect of coronary artery disease (CAD) on mortality in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: CAD is common in the TAVR population. However, there are conflicting data on the prognostic significance of CAD and its treatment in this population. METHODS: The authors analyzed 1,270 consecutive patients with severe aortic stenosis (AS) undergoing TAVR at 3 Israeli centers. They investigated the association of CAD severity (no CAD, nonsevere CAD [i.e., SYNTAX score (SS) <22], severe CAD [SS >22]) and revascularization completeness ("reasonable" incomplete revascularization [ICR] [i.e., residual SS <8]; ICR [residual SS >8]) with all-cause mortality following TAVR using a Cox proportional hazards ratio model adjusted for multiple prognostic variables. RESULTS: Of the 1,270 patients, 817 (64%) had no CAD, 331 (26%) had nonsevere CAD, and 122 (10%) had severe CAD. Over a median follow-up of 1.9 years, 311 (24.5%) patients died. Mortality was higher in the severe CAD and the ICR groups, but not in the nonsevere CAD or "reasonable" ICR groups, versus no CAD. After multivariate adjustment, both severe CAD (hazard ratio: 2.091; p = 0.017) and ICR (hazard ratio: 1.720; p = 0.031) were associated with increased mortality. CONCLUSIONS: Only severe CAD was associated with increased mortality post-TAVR. More complete revascularization pre-TAVR may attenuate the association of severe CAD and mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Circ Cardiovasc Interv ; 10(4)2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28400461

RESUMO

BACKGROUND: Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). METHODS AND RESULTS: Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm2; P=0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P=0.02), and lower core laboratory-adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P=0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P=0.03). CONCLUSIONS: In this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Oriente Médio/epidemiologia , Nova Zelândia/epidemiologia , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Reoperação/métodos , Taxa de Sobrevida/tendências , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos/epidemiologia
20.
Case Rep Cardiol ; 2017: 2760580, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29348945

RESUMO

High precision is necessary during percutaneous transcatheter heart valve implantation. The precision of the implantation has been established by increasing the heart rate (usually to 200 beats per minute) to the point of significantly reduced cardiac output and thus minimizing valve movement. Routinely, this tachycardia is induced by rapid pacing. Here we report a case of failure to pace during valve-in-valve (VIV) Edwards Sapien XT implantation in the tricuspid valve position. Transient cardiac arrest was induced by intravenous adenosine injection enabling accurate valve implantation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA