Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Ultrason Imaging ; 46(2): 130-134, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38318708

RESUMO

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity (ftransmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs (n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB (p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB (p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.


Assuntos
Meios de Contraste , Fluorocarbonos , Ácidos Tri-Iodobenzoicos , Água , Ultrassonografia/métodos
2.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358329

RESUMO

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Assuntos
Compostos Férricos , Ferro , Microbolhas , Óxidos , Humanos , Coração , Ventrículos do Coração
3.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38028186

RESUMO

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

4.
J Transl Med ; 21(1): 477, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37461108

RESUMO

Pulmonary arterial hypertension (PAH) is a multifactorial disease associated with the remodeling of pulmonary blood vessels. If left unaddressed, PAH can lead to right heart failure and even death. Multiple biological processes, such as smooth muscle proliferation, endothelial dysfunction, inflammation, and resistance to apoptosis, are associated with PAH. Increasing evidence suggests that epigenetic factors play an important role in PAH by regulating the chromatin structure and altering the expression of critical genes. For example, aberrant DNA methylation and histone modifications such as histone acetylation and methylation have been observed in patients with PAH and are linked to vascular remodeling and pulmonary vascular dysfunction. In this review article, we provide a comprehensive overview of the role of key epigenetic targets in PAH pathogenesis, including DNA methyltransferase (DNMT), ten-eleven translocation enzymes (TET), switch-independent 3A (SIN3A), enhancer of zeste homolog 2 (EZH2), histone deacetylase (HDAC), and bromodomain-containing protein 4 (BRD4). Finally, we discuss the potential of multi-omics integration to better understand the molecular signature and profile of PAH patients and how this approach can help identify personalized treatment approaches.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Humanos , Hipertensão Arterial Pulmonar/genética , Medicina de Precisão , Hipertensão Pulmonar/patologia , Fatores de Transcrição/metabolismo , Proteínas Nucleares/metabolismo , Artéria Pulmonar/metabolismo , Artéria Pulmonar/patologia , Epigênese Genética , Remodelação Vascular/genética , Proteínas de Ciclo Celular/genética
5.
J Clin Transl Hepatol ; 11(3): 534-539, 2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-36969887

RESUMO

Background and Aims: Distinguishing alcoholic steatohepatitis (ASH) and nonalcoholic steatohepatitis (NASH) with biopsy alone is often difficult without a reliable clinical context. A novel finding on liver imaging, perivascular branching heterogeneity, has shown promise in distinguishing between these chronic liver diseases. Our study investigated the role of this finding on imaging to differentiate between ASH and NASH. The aim of this study was to determine the utility and reproducibility of this novel radiographic marker to help distinguish ASH from NASH. Methods: This was a retrospective cohort study conducted between 2016 and 2020 in patients with both liver biopsy-confirmed steatohepatitis/chronic hepatitis and abdominal magnetic resonance imaging within 13 months of each other. Two radiologists, blinded to patient clinical history and diagnosis, categorized the appearance of the liver as: 1- homogeneity, 2- mild heterogeneity, 3- moderate heterogeneity, 4- possible perivascular branching, 5- definite perivascular branching. Results: Of the 90 patients in the study, 60 were identified as NASH and 30 as ASH. The area under the curve (AUC) for both reader 1 and 2 when using the 5-point scale was 0.69 (CI: 0.56-0.82, p=0.006) and 0.72 (CI: 0.60-0.85, p=0.001), respectively. The positive predictive value (PPV) for identification of ASH when scoring 5 was 64.7% and 66.7% for reader 1 and 2, respectively. Interclass correlation coefficient was 0.74 in patients with ASH, indicating moderate reliability among both readers. Conclusions: Identification of this perivascular branching pattern on imaging is a promising novel diagnostic marker that can be used with other methods to help distinguish between ASH and NASH.

6.
J Appl Clin Med Phys ; 24(5): e13938, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36995917

RESUMO

Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.


Assuntos
Radiografia , Humanos , Controle de Qualidade , Padrões de Referência
7.
J Magn Reson Imaging ; 58(4): 1191-1197, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36744579

RESUMO

BACKGROUND: Focal nodular hyperplasia (FNH) and hepatic adenoma (HA) are two common benign liver lesions with different management options. In particular, resection is considered for large HA lesions to avoid possible bleeding complications or rarely malignant degeneration. PURPOSE: To determine whether early enhancement of a draining hepatic vein (EDHV) and absence of perilesional enhancement (PLE) on arterial phase MR images are useful for distinguishing FNH from HA. STUDY TYPE: Retrospective. POPULATION: A total of 34 patients: 16 with FNH and 18 with HA lesions. FIELD STRENGTH/SEQUENCE: A1.5 T, axial T1 fat-suppressed arterial postcontrast. ASSESMENT: Four abdominal radiologists blinded to pathologic diagnosis assessed for the presence or absence of EDHV in association with the lesion, definitively characterized by pathology. This was considered present if contrast could be identified in a hepatic vein contiguous with the lesion in question. Secondarily, PLE was evaluated. STATISTICAL TESTS: Fleiss's multirater kappa statistic, Chi-squared statistic, Phi-coefficient. Significance level P < 0.05. RESULTS: Considering all observations obtained from the four readers, an EDHV was identified with FNH 48.5% of the time. EDHV was seen with HA in 8.8% of cases. PLE was seen with significantly greater frequency in HA. The presence of an EDHV was associated with the absence of PLE. DATA CONCLUSION: In a lesion that may be either an FNH or HA, confident identification on arterial phase images of an EDHV should lead the reader to favor FNH, while the presence PLE should dissuade the reader from FNH. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 2.


Assuntos
Adenoma de Células Hepáticas , Hiperplasia Nodular Focal do Fígado , Neoplasias Hepáticas , Humanos , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Hiperplasia Nodular Focal do Fígado/patologia , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Veias Hepáticas , Meios de Contraste , Adenoma de Células Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Diferencial
8.
JACC Cardiovasc Imaging ; 16(2): 224-235, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36648035

RESUMO

BACKGROUND: Noninvasive and accurate assessment of intracardiac pressures has remained an elusive goal of noninvasive cardiac imaging. OBJECTIVES: The purpose of this study was to investigate if errors in intracardiac pressures obtained noninvasively using contrast microbubbles and the subharmonic-aided pressure estimation (SHAPE) technique are <5 mm Hg. METHODS: In a nonrandomized institutional review board-approved clinical trial (NCT03243942), patients scheduled for a left-sided and/or right-sided heart catheterization procedure and providing written informed consent were included. A standard-of-care catheterization procedure was performed advancing clinically used pressure catheters into the left and/or right ventricles and/or the aorta. After pressure catheter placement, patients received an infusion of Definity microbubbles (n = 56; 2 vials diluted in 50 mL of saline; infusion rate: 4-10 mL/min) (Lantheus Medical Imaging). Then SHAPE data was acquired using a validated interface developed on a SonixTablet scanner (BK Medical Systems) synchronously with the pressure catheter data. A conversion factor (mm Hg/dB) was derived from SHAPE data and measurements with a SphygmoCor XCEL PWA device (ATCOR Medical) and was combined with SHAPE data from the left and/or the right ventricles to obtain clinically relevant systolic and diastolic ventricular pressures. RESULTS: The mean value of absolute errors for left ventricular minimum and end diastolic pressures were 2.9 ± 2.0 and 1.7 ± 1.2 mm Hg (n = 26), respectively, and for right ventricular systolic pressures was 2.2 ± 1.5 mm Hg (n = 11). Two adverse events occurred during Definity infusion; both were resolved. CONCLUSIONS: These results indicate that the SHAPE technique with Definity microbubbles is encouragingly efficacious for obtaining intracardiac pressures noninvasively and accurately. (Noninvasive, Subharmonic Intra-Cardiac Pressure Measurement; NCT03243942).


Assuntos
Meios de Contraste , Microbolhas , Humanos , Ultrassonografia/métodos , Valor Preditivo dos Testes , Cateterismo Cardíaco/efeitos adversos
9.
Curr Probl Diagn Radiol ; 52(3): 180-186, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36470698

RESUMO

Detection of pulmonary nodules on chest x-rays is an important task for radiologists. Previous studies have shown improved detection rates using gray-scale inversion. The purpose of our study was to compare the efficacy of gray-scale inversion in improving the detection of pulmonary nodules on chest x-rays for radiologists and machine learning models (ML). We created a mixed dataset consisting of 60, 2-view (posteroanterior view - PA and lateral view) chest x-rays with computed tomography confirmed nodule(s) and 62 normal chest x-rays. Twenty percent of the cases were separated for a testing dataset (24 total images). Data augmentation through mirroring and transfer learning was used for the remaining cases (784 total images) for supervised training of 4 ML models (grayscale PA, grayscale lateral, gray-scale inversion PA, and gray-scale inversion lateral) on Google's cloud-based AutoML platform. Three cardiothoracic radiologists analyzed the complete 2-view dataset (n=120) and, for comparison to the ML, the single-view testing subsets (12 images each). Gray-scale inversion (area under the curve (AUC) 0.80, 95% confidence interval (CI) 0.75-0.85) did not improve diagnostic performance for radiologists compared to grayscale (AUC 0.84, 95% CI 0.79-0.88). Gray-scale inversion also did not improve diagnostic performance for the ML. The ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5% respectively). In the limited testing dataset, the ML did demonstrate higher sensitivity and negative predictive value for grayscale PA (72.7% and 75.0%), grayscale lateral (63.6% and 66.6%), and gray-scale inversion lateral views (72.7% and 76.9%), comparing favorably to the radiologists (63.9% and 72.3%, 27.8% and 58.3%, 19.5% and 50.5%, respectively). Further investigation of other post-processing algorithms to improve diagnostic performance of ML is warranted.


Assuntos
Nódulos Pulmonares Múltiplos , Radiografia Torácica , Humanos , Raios X , Radiografia Torácica/métodos , Estudos Retrospectivos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Redes Neurais de Computação , Radiologistas
10.
J Appl Clin Med Phys ; 23(7): e13664, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35699199

RESUMO

There is no current authoritative accounting of the number of clinical imaging physicists practicing in the United States. Information about the workforce is needed to inform future efforts to secure training pathways and opportunities. In this study, the AAPM Diagnostic Demand and Supply Projection Working Group collected lists of medical physicists from several state registration and licensure programs and the Conference of Radiation Control Program Directors (CRCPD) registry. By cross-referencing individuals among these lists, we were able to estimate the current imaging physics workforce in the United States by extrapolating based on population. The imaging physics workforce in the United States in 2019 consisted of approximately 1794 physicists supporting diagnostic X-ray (1073 board-certified) and 934 physicists supporting nuclear medicine (460 board-certified), with a number of individuals practicing in both subfields. There were an estimated 235 physicists supporting nuclear medicine exclusively (150 board-certified). The estimated total workforce, accounting for overlap, was 2029 medical physicists. These estimates are in approximate agreement with other published studies of segments of the workforce.


Assuntos
Radioterapia (Especialidade) , Diagnóstico por Imagem , Física Médica/educação , Humanos , Física , Radioterapia (Especialidade)/educação , Radiografia , Estados Unidos , Recursos Humanos
11.
Stem Cell Res ; 60: 102737, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35247838

RESUMO

The R14del pathogenic variant in the phospholamban (PLN) gene (PLN-R14del), has been identified in families with hereditary cardiomyopathy, including dilated and arrhythmogenic cardiomyopathies. Here we have generated human iPSC lines from five PLN-R14del carriers and three non-carrier family members. Peripheral blood mononuclear cells (PBMC) were obtained from the eight individuals and reprogrammed using Sendai viral vector system carrying the Yamanaka factors. All eight lines show typical iPSC morphology, normal karyotype, high expression of pluripotency markers, and possess the ability to differentiate into all three germ layers. These lines represent valuable resources for studying the pathophysiological mechanisms of PLN-R14del associated cardiomyopathy.


Assuntos
Cardiomiopatias , Células-Tronco Pluripotentes Induzidas , Proteínas de Ligação ao Cálcio/genética , Cardiomiopatias/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Leucócitos Mononucleares/metabolismo , Mutação
13.
Cardiovasc Res ; 118(15): 3140-3150, 2022 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-35191471

RESUMO

AIMS: A mutation in the phospholamban (PLN) gene, leading to deletion of Arg14 (R14del), has been associated with malignant arrhythmias and ventricular dilation. Identifying pre-symptomatic carriers with vulnerable myocardium is crucial because arrhythmia can result in sudden cardiac death, especially in young adults with PLN-R14del mutation. This study aimed at assessing the efficiency and efficacy of in vivo genome editing, using CRISPR/Cas9 and a cardiotropic adeno-associated virus-9 (AAV9), in improving cardiac function in young adult mice expressing the human PLN-R14del. METHODS AND RESULTS: Humanized mice were generated expressing human wild-type (hPLN-WT) or mutant (hPLN-R14del) PLN in the heterozygous state, mimicking human carriers. Cardiac magnetic resonance imaging at 12 weeks of age showed bi-ventricular dilation and increased stroke volume in mutant vs. WT mice, with no deficit in ejection fraction or cardiac output. Challenge of ex vivo hearts with isoproterenol and rapid pacing unmasked higher propensity for sustained ventricular tachycardia (VT) in hPLN-R14del relative to hPLN-WT. Specifically, the VT threshold was significantly reduced (20.3 ± 1.2 Hz in hPLN-R14del vs. 25.7 ± 1.3 Hz in WT, P < 0.01) reflecting higher arrhythmia burden. To inactivate the R14del allele, mice were tail-vein-injected with AAV9.CRISPR/Cas9/gRNA or AAV9 empty capsid (controls). CRISPR-Cas9 efficiency was evaluated by droplet digital polymerase chain reaction and NGS-based amplicon sequencing. In vivo gene editing significantly reduced end-diastolic and stroke volumes in hPLN-R14del CRISPR-treated mice compared to controls. Susceptibility to VT was also reduced, as the VT threshold was significantly increased relative to controls (30.9 ± 2.3 Hz vs. 21.3 ± 1.5 Hz; P < 0.01). CONCLUSIONS: This study is the first to show that disruption of hPLN-R14del allele by AAV9-CRISPR/Cas9 improves cardiac function and reduces VT susceptibility in humanized PLN-R14del mice, offering preclinical evidence for translatable approaches to therapeutically suppress the arrhythmogenic phenotype in human patients with PLN-R14del disease.


Assuntos
Cardiomiopatias , Edição de Genes , Humanos , Camundongos , Animais , Cardiomiopatias/genética , Cardiomiopatias/terapia
14.
Am J Hypertens ; 35(5): 397-406, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35079778

RESUMO

BACKGROUND: This study compared aortic pressures estimated using a SphygmoCor XCEL PWA device (ATCOR, Naperville, IL) noninvasively with aortic pressures obtained using pressure catheters during catheterization procedures and analyzed the impact of a linear-fit function on the estimated pressure values. METHODS: One hundred and thirty-six patients scheduled for cardiac catheterization procedure were enrolled in IRB approved studies. Catheterization procedures were performed according to standard-of-care to acquire aortic pressure measurements. Immediately after the catheterization procedure with the pressure catheters removed, while the patients were still in the catheterization laboratory, central aortic pressures were estimated with the SphygmoCor device (using its inbuilt transfer function). The error between measured and estimated aortic pressures was evaluated using Bland-Altman analysis (n = 93). A linear-fit was performed between the measured and estimated pressures, and using the linear equation the error measurements were repeated. A bootstrap analysis was performed to test the generalizability of the linear-fit function. In a subset of cases (n = 13), central aortic pressure values were also obtained using solid-state high-fidelity catheters (Millar, Houston, TX), and the error measurements were repeated. RESULTS: The magnitude of errors between the measured and estimated aortic pressures (mean errors >6.4 mm Hg; mean errors >8.0 mm Hg in the subset) were reduced to less than 1 mm Hg after using the linear-fit function derived in this study. CONCLUSIONS: For the population examined in this study, the SphygmoCor data must be used with the linear-fit function to obtain aortic pressures that are comparable to the measurements obtained using pressure catheters. CLINICAL TRIALS REGISTRATION: Trial Numbers NCT03243942 and NCT03245255.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Cateterismo Cardíaco , Catéteres , Humanos
15.
J Ultrasound Med ; 41(7): 1781-1789, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34724241

RESUMO

OBJECTIVES: Subharmonic aided pressure estimation (SHAPE) has been shown effective for noninvasively measuring hydrostatic fluid pressures in a variety of clinical applications. The objective of this study was to explore potential improvements in SHAPE sensitivity using monodisperse microbubbles. METHODS: Populations of monodisperse microbubbles were created using a commercially available microfluidics device (Solstice Pharmaceuticals). Size distributions were assessed using a Coulter Counter and stability of the distribution following fabrication was evaluated over 24 hours. Attenuation of the microbubble populations from 1 to 10 MHz was then quantified using single element transducers to identify each formulation's resonance frequency. Frequency spectra over increasing driving amplitudes were investigated to determine the nonlinear phases of subharmonic signal generation. SHAPE sensitivity was evaluated in a hydrostatic pressure-controlled water bath using a Logiq E10 scanner (GE Healthcare). RESULTS: Monodisperse lipid microbubble suspensions ranging from 2.4 to 5.3 µm in diameter were successfully created and they showed no discernable change in size distribution over 24 hours following activation. Calculated resonance frequencies ranged from 2.1 to 6.3 MHz and showed excellent correlation with microbubble diameter (R2 > 0.99). When investigating microbubble frequency response, subharmonic signal occurrence was shown to begin at 150 kPa peak negative pressure, grow up to 225 kPa, and saturate at approximately 250 kPa. Using the Logiq E10, monodisperse bubbles demonstrated a SHAPE sensitivity of -0.17 dB/mmHg, which was nearly twice the sensitivity of the commercial polydisperse microbubble currently being used in clinical trials. CONCLUSIONS: Monodisperse microbubbles have the potential to greatly improve the sensitivity of SHAPE for the noninvasive measurement of hydrostatic pressures.


Assuntos
Meios de Contraste , Microbolhas , Determinação da Pressão Arterial , Humanos , Transdutores , Ultrassonografia
16.
Nat Commun ; 12(1): 3316, 2021 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-34083524

RESUMO

The methylglyoxal-derived hydroimidazolone isomer, MGH-1, is an abundant advanced glycation end-product (AGE) associated with disease and age-related disorders. As AGE formation occurs spontaneously and without an enzyme, it remains unknown why certain sites on distinct proteins become modified with specific AGEs. Here, we use a combinatorial peptide library to determine the chemical features that favor MGH-1. When properly positioned, tyrosine is found to play an active mechanistic role that facilitates MGH-1 formation. This work offers mechanistic insight connecting multiple AGEs, including MGH-1 and carboxyethylarginine (CEA), and reconciles the role of negative charge in influencing glycation outcomes. Further, this study provides clear evidence that glycation outcomes can be influenced through long- or medium-range cooperative interactions. This work demonstrates that these chemical features also predictably template selective glycation on full-length protein targets expressed in mammalian cells. This information is vital for developing methods that control glycation in living cells and will enable the study of glycation as a functional post-translational modification.


Assuntos
Produtos Finais de Glicação Avançada/metabolismo , Proteínas/metabolismo , Sequência de Aminoácidos , Arginina/análogos & derivados , Arginina/química , Arginina/metabolismo , Produtos Finais de Glicação Avançada/química , Glicosilação , Células HEK293 , Humanos , Imidazóis/química , Imidazóis/metabolismo , Isomerismo , Biblioteca de Peptídeos , Processamento de Proteína Pós-Traducional , Proteínas/química , Proteínas/genética , Aldeído Pirúvico/análogos & derivados , Aldeído Pirúvico/química , Aldeído Pirúvico/metabolismo
17.
Skeletal Radiol ; 50(7): 1399-1409, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33404668

RESUMO

OBJECTIVE: To evaluate adults with history of Osgood Schlatter disease (OSD) for imaging features of lateral patellofemoral maltracking. METHODS: In a span of four years, 10,181 unique non-contrast knee MRIs were performed on patients aged 20-50. Patients with acute trauma, prior surgery, and synovial pathologies were excluded. 171 exams had imaging findings of OSD, and an age-matched control group of 342 patients without OSD was randomly selected. Two radiologists retrospectively reviewed MRIs for features of lateral patellofemoral maltracking. Maltracking was defined as edema in superolateral Hoffa's fat or a tibial tuberosity-trochlear groove (TT-TG) distance ≥20 mm with either patellar tilt/translation. Binomial logistic regression identified predictors of maltracking in OSD. Optimal TT-TG distance to indicate maltracking was determined by receiver operating characteristic curve. RESULTS: 59% (101/171) of the knees with OSD showed findings of maltracking, with patella alta, trochlear dysplasia, and quadriceps tendinosis as significant predictors of maltracking (p < 0.001). Patellofemoral chondrosis was present in 63% (107/171), with maltracking contributing to higher grade chondrosis more so than increasing age (OR 8.4 versus 1.07). 13 mm was the optimal cut-off TT-TG distance to indicate maltracking (sensitivity 83%, specificity 80%). The prevalence of maltracking in the control group was 15% (p < 0.001 compared with the OSD group). CONCLUSION: Adults with sequelae of OSD are at high risk of maltracking and are likely to develop patellofemoral chondrosis. A lower threshold for identifying maltracking patients, including a lower cut-off TT-TG distance can help identify those at risk. Radiologists should maintain a high index of suspicion for maltracking in adults with OSD to guide clinical intervention.


Assuntos
Instabilidade Articular , Osteocondrose , Articulação Patelofemoral , Adulto , Humanos , Imageamento por Ressonância Magnética , Patela , Articulação Patelofemoral/diagnóstico por imagem , Prevalência , Estudos Retrospectivos , Tíbia
18.
Abdom Radiol (NY) ; 46(6): 2908-2912, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33433636

RESUMO

PURPOSE: To evaluate the productivity difference between teaching and non-teaching workflow models in an abdominal imaging division in an academic radiology department. METHODS AND MATERIALS: RVU data were compiled for six faculty members from the abdominal imaging division over a six-month period. Modalities included ultrasound and CT of the abdomen and pelvis. The relative RVU productivity for faculty members by workflow was compared individually and the composite data for the workflow models were compared. The relative RVU productivity for each faculty member was compared individually and in aggregate to study the effect of the workflow models on RVUs using factorial ANOVA. Turnaround times (TAT) were compared for each attending under both models. TAT data were analyzed using paired t-tests with Bonferroni corrections for multiple comparisons. RESULTS: Daily RVU data from 387 instances were analyzed. Daily RVUs for faculty members ranged from 23.5 ± 2.3 (mean ± standard error) to 46.2 ± 2.4 with non-teaching and from 29.8 ± 2.2 to 54.4 ± 2.7 with teaching workflow, respectively. There was a significant main effect of the workflow model on RVU productivity (p < 0.05). A significant increase of 27.8% in RVUs was noted with teaching workflow (42.8 ± 0.9) relative to non-teaching workflow (33.5 ± 1.7; p < 0.05). Teaching workflow resulted in significantly higher view-final and complete-final TATs (593 ± 112 min, mean ± SE and 841 ± 96 min, mean ± SE, respectively) compared to the non-teaching workflow (385 ± 124 min). CONCLUSION: Teaching workflow improves abdominal imaging productivity with an increase in report turnaround times.


Assuntos
Diagnóstico por Imagem , Escalas de Valor Relativo , Abdome , Humanos , Ultrassonografia , Fluxo de Trabalho
19.
Artigo em Inglês | MEDLINE | ID: mdl-32784134

RESUMO

Thisstudy focuses on evaluating the real-time functionality of a customized interface and investigating the optimal parameters for intracardiac subharmonic-aided pressure estimation (SHAPE) utilizing Definity (Lantheus Medical Imaging Inc., North Billerica, MA, USA) and Sonazoid (GE Healthcare, Oslo, Norway) microbubbles. Pressure measurements within the chambers of the heart yield critical information for managing cardiovascular diseases. An alternative to current, invasive, clinical cardiac catheterization procedures is utilizing ultrasound contrast agents and SHAPE to noninvasively estimate intracardiac pressures. Therefore, this work developed a customized interface (on a SonixTablet, BK Ultrasound, Peabody, MA, USA) for real-time intracardiac SHAPE. In vitro, a Doppler flow phantom was utilized to mimic the dynamic pressure changes within the heart. Definity (15.0- [Formula: see text] microspheres corresponding to 0.1-0.15 mL) and Sonazoid (GE Healthcare; 0.4- [Formula: see text] microspheres corresponding to 0.05-0.15 mL) microbubbles were used. Data were acquired for varying transmit frequencies (2.5-4.0 MHz), and pulse shaping options (square wave and chirp down) to determine optimal transmit parameters. Simultaneously obtained radio frequency data and ambient pressure data were compared. For Definity, the chirp down pulse at 3.0 MHz yielded the highest correlation ( r = - 0.77 ± 0.2 ) between SHAPE and pressure catheter data. For Sonazoid, the square wave pulse at 2.5 MHz yielded the highest correlation ( r = - 0.72 ± 0.2 ). In conclusion, the real-time functionality of the customized interface has been verified, and the optimal parameters for utilizing Definity and Sonazoid for intracardiac SHAPE have been determined.


Assuntos
Meios de Contraste , Microbolhas , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia Doppler
20.
Acad Radiol ; 28(11): 1559-1569, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-32224035

RESUMO

RATIONALE AND OBJECTIVES: To investigate differences in radiation dose and image quality for single-plane flat-panel-detector based interventional fluoroscopy systems from two vendors using phantom study and clinical procedures. MATERIALS AND METHODS: AlluraClarityIQ (Philips) and Artis Q (Siemens-Healthineers) interventional fluoroscopy systems were evaluated. Phantom study included comparison of system-reported air-kerma rates (AKR) for clinical protocols with simulated patient thicknesses (20-40 cm). Differences in system-reported radiation dose estimates, cumulative-air-kerma (CAK) and kerma-area-product (KAP), for different clinical procedures were investigated. Subset analysis investigated differences in CAK, KAP and other factors affecting radiation dose when the same patients underwent repeat embolization procedures performed by the same physician on the two different fluoroscopy systems. Two blinded interventional radiologists reviewed image-quality for these procedures using a five-point scale (1-5; 5-best) for five parameters. RESULTS: Phantom study revealed that air-kerma rates was significantly higher for Artis Q system for 30-40cm of simulated patient thicknesses (p < 0.05). Overall data analysis from 4381 clinical cases revealed significant differences in CAK and KAP for certain procedures (p < 0.05); with significantly lower values for AlluraClarityIQ systems (median CAK lower by: 29%-58%). Subset analysis with 40 patients undergoing repeat embolization procedures on both systems revealed that median CAK and KAP were significantly lower for AlluraClarityIQ systems (p < 0.02) by 45% and 31%, respectively. Image quality scores for AlluraClarityIQ systems were significantly greater (mean difference range for five parameters: 1.3-1.6; p < 0.005). CONCLUSION: Radiation dose and image quality differences were observed between AlluraClarityIQ and Artis Q systems. AlluraClarityIQ systems showed lower radiation utilization and an increase in subjective perception of image quality.


Assuntos
Embolização Terapêutica , Radiografia Intervencionista , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA