Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
IEEE Sens J ; 22(5): 4569-4580, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35673527

RESUMO

An Electrical Impedance Tomography (EIT) system has been developed for dynamic three-dimensional imaging of changes in conductivity distribution in the human head, using scalp-mounted electrodes. We attribute these images to changes in cerebral perfusion. At 100 frames per second (fps), voltage measurement is achieved with full-scale signal-to-noise ratio of 105 dB and common-mode rejection ratio > 90 dB. A novel nonlinear method is presented for 3-D imaging of the difference in conductivity distribution in the head, relative to a reference time. The method achieves much reduced modelling error. It successfully localizes conductivity inclusions in experimental and simulation tests, where previous methods fail. For > 50 human volunteers, the rheoencephalography (REG) waveform is observed in EIT voltage measurements for every volunteer, with peak-to-peak amplitudes up to approx. 50 µVrms. Images are presented of the change in conductivity distribution during the REG/cardiac cycle, at 50 fps, showing maximum local conductivity change of approx. 1% in grey/white matter. A total of 17 tests were performed during short (typically 5s) carotid artery occlusions on 5 volunteers, monitored by Transcranial Doppler ultrasound. From EIT measurements averaged over complete REG/cardiac cycles, 13 occlusion tests showed consistently decreased conductivity of cerebral regions on the occluded side, and increased conductivity on the opposite side. The maximum local conductivity change during occlusion was approx. 20%. The simplicity of the carotid artery intervention provides a striking validation of the scalp-mounted measurement system in imaging cerebral hemodynamics, and the REG images indicate its unique combination of sensitivity and temporal resolution.

2.
Artigo em Inglês | MEDLINE | ID: mdl-22255957

RESUMO

Electrical Impedance Tomography (EIT) can resolve dynamic physiological information deep within human subjects [1], but its sensitivity is challenged in the case of imaging the head [2]. Here, we report a new system called fEITER that has been designed and built to enable functional imaging of the human brain using EIT via scalp-mounted electrodes, integrated with stimulation of evoked responses. Using Field-Programmable Gate Array (FPGA) technology, it provides excellent flexibility in terms of current-pattern excitation and signal processing. The instrument operates at 100 frames/second (fps) with noise of 1 µV on the rms voltage measurements. Clinical trials have been authorized by the UK MHRA and example data from human subjects are presented.


Assuntos
Impedância Elétrica , Eletrocardiografia/métodos , Eletrofisiologia/métodos , Tomografia/métodos , Encéfalo/patologia , Mapeamento Encefálico/métodos , Computadores , Condutividade Elétrica , Eletrodos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Couro Cabeludo/patologia , Razão Sinal-Ruído , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA