Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 128(13): 132501, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35426696

RESUMO

We report the first measurement of the parity-violating elastic electron scattering asymmetry on ^{27}Al. The ^{27}Al elastic asymmetry is A_{PV}=2.16±0.11(stat)±0.16(syst) ppm, and was measured at ⟨Q^{2}⟩=0.02357±0.00010 GeV^{2}, ⟨θ_{lab}⟩=7.61°±0.02°, and ⟨E_{lab}⟩=1.157 GeV with the Q_{weak} apparatus at Jefferson Lab. Predictions using a simple Born approximation as well as more sophisticated distorted-wave calculations are in good agreement with this result. From this asymmetry the ^{27}Al neutron radius R_{n}=2.89±0.12 fm was determined using a many-models correlation technique. The corresponding neutron skin thickness R_{n}-R_{p}=-0.04±0.12 fm is small, as expected for a light nucleus with a neutron excess of only 1. This result thus serves as a successful benchmark for electroweak determinations of neutron radii on heavier nuclei. A tree-level approach was used to extract the ^{27}Al weak radius R_{w}=3.00±0.15 fm, and the weak skin thickness R_{wk}-R_{ch}=-0.04±0.15 fm. The weak form factor at this Q^{2} is F_{wk}=0.39±0.04.

2.
Phys Rev Lett ; 125(11): 112502, 2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32976004

RESUMO

A beam-normal single-spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable related to the imaginary part of the two-photon exchange process. We report a 2% precision measurement of the beam-normal single-spin asymmetry in elastic electron-proton scattering with a mean scattering angle of θ_{lab}=7.9° and a mean energy of 1.149 GeV. The asymmetry result is B_{n}=-5.194±0.067(stat)±0.082 (syst) ppm. This is the most precise measurement of this quantity available to date and therefore provides a stringent test of two-photon exchange models at far-forward scattering angles (θ_{lab}→0) where they should be most reliable.

3.
Phys Rev Lett ; 111(14): 141803, 2013 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-24152148

RESUMO

The Q(weak) experiment has measured the parity-violating asymmetry in ep elastic scattering at Q(2)=0.025(GeV/c)(2), employing 145 µA of 89% longitudinally polarized electrons on a 34.4 cm long liquid hydrogen target at Jefferson Lab. The results of the experiment's commissioning run, constituting approximately 4% of the data collected in the experiment, are reported here. From these initial results, the measured asymmetry is A(ep)=-279±35 (stat) ± 31 (syst) ppb, which is the smallest and most precise asymmetry ever measured in ep scattering. The small Q(2) of this experiment has made possible the first determination of the weak charge of the proton Q(W)(p) by incorporating earlier parity-violating electron scattering (PVES) data at higher Q(2) to constrain hadronic corrections. The value of Q(W)(p) obtained in this way is Q(W)(p)(PVES)=0.064±0.012, which is in good agreement with the standard model prediction of Q(W)(p)(SM)=0.0710±0.0007. When this result is further combined with the Cs atomic parity violation (APV) measurement, significant constraints on the weak charges of the up and down quarks can also be extracted. That PVES+APV analysis reveals the neutron's weak charge to be Q(W)(n)(PVES+APV)=-0.975±0.010.

4.
Ann Dyslexia ; 63(3-4): 187-200, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23152145

RESUMO

The purpose of this paper is to describe briefly the development and utility of the Assessment of Reading Instructional Knowledge-Adults (ARIK-A), the only nationally normed (n = 468) measure of adult reading instructional knowledge, created to facilitate professional development of adult educators. Developmental data reveal reliabilities ranging from 0.73 to 0.85 for five ARIK-A scales (alphabetics, fluency, vocabulary, comprehension, and assessment) and 0.91 for the composite score; factor analytic data and expert review provide support for construct validity as well. Information on how to use the ARIK-A to determine mastery and relative standing is presented. With two alternate forms, the ARIK-A is a promising and needed tool for adult education practitioners within continuing education and professional development contexts.


Assuntos
Compreensão , Educação Inclusiva , Leitura , Vocabulário , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Educação Continuada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estados Unidos , Adulto Jovem
5.
Phys Rev Lett ; 108(12): 122002, 2012 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-22540573

RESUMO

The parity-violating (PV) asymmetry of inclusive π- production in electron scattering from a liquid deuterium target was measured at backward angles. The measurement was conducted as a part of the G0 experiment, at a beam energy of 360 MeV. The physics process dominating pion production for these kinematics is quasifree photoproduction off the neutron via the Δ0 resonance. In the context of heavy-baryon chiral perturbation theory, this asymmetry is related to a low-energy constant d(Δ)- that characterizes the parity-violating γNΔ coupling. Zhu et al. calculated d(Δ)- in a model benchmarked by the large asymmetries seen in hyperon weak radiative decays, and predicted potentially large asymmetries for this process, ranging from A(γ)-=-5.2 to +5.2 ppm. The measurement performed in this work leads to A(γ)-=-0.36±1.06±0.37±0.03 ppm (where sources of statistical, systematic and theoretical uncertainties are included), which would disfavor enchancements considered by Zhu et al. proportional to V(ud)/V(us). The measurement is part of a program of inelastic scattering measurements that were conducted by the G0 experiment, seeking to determine the N-Δ axial transition form factors using PV electron scattering.

7.
Phys Rev Lett ; 107(2): 022501, 2011 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-21797598

RESUMO

We have measured the beam-normal single-spin asymmetries in elastic scattering of transversely polarized electrons from the proton, and performed the first measurement in quasielastic scattering on the deuteron, at backward angles (lab scattering angle of 108°) for Q² = 0.22 GeV²/c² and 0.63 GeV²/c² at beam energies of 362 and 687 MeV, respectively. The asymmetry arises due to the imaginary part of the interference of the two-photon exchange amplitude with that of single-photon exchange. Results for the proton are consistent with a model calculation which includes inelastic intermediate hadronic (πN) states. An estimate of the beam-normal single-spin asymmetry for the scattering from the neutron is made using a quasistatic deuterium approximation, and is also in agreement with theory.

8.
Phys Rev Lett ; 104(1): 012001, 2010 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-20366359

RESUMO

We have measured parity-violating asymmetries in elastic electron-proton and quasielastic electron-deuteron scattering at Q2=0.22 and 0.63 GeV2. They are sensitive to strange quark contributions to currents in the nucleon and the nucleon axial-vector current. The results indicate strange quark contributions of approximately < 10% of the charge and magnetic nucleon form factors at these four-momentum transfers. We also present the first measurement of anapole moment effects in the axial-vector current at these four-momentum transfers.

9.
J Med Phys ; 34(4): 223-5, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20098553

RESUMO

Techniques are being standardized in our department for total body irradiation (TBI) with six MV photons in linear accelerator for preconditioning to bone marrow transplantation (BMT). Individualized shields with low melting point alloy are to be fabricated for shielding critical organs such as lungs, kidneys etc. A method to mount diminished dimension of shields in a tray at 3.75m is designed in the department for a teletreatment distance of four meters with magna field with A simulator image taken with the patient's midplane (MP) at one meter distance is used to mark the dimensions of lung, scaled down by a factor of 3.75/4.0. These lung dimensions are reprinted from the digital simulator image for making the shield. The methodology of the technique using digitized minification in radiography is the first of its kind to be used for shield cutting in magna field radiotherapy.

10.
J Med Phys ; 34(1): 31-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20126563

RESUMO

The objective of the present study is to establish radiation standards for absorbed doses, for clinical high energy linear accelerator beams. In the nonavailability of a cobalt-60 beam for arriving at Nd, water values for thimble chambers, we investigated the efficacy of perspex mounted extrapolation chamber (EC) used earlier for low energy x-rays and beta dosimetry. Extrapolation chamber with facility for achieving variable electrode separations 10.5mm to 0.5mm using micrometer screw was used for calibrations. Photon beams 6 MV and 15 MV and electron beams 6 MeV and 15 MeV from Varian Clinac linacs were calibrated. Absorbed Dose estimates to Perspex were converted into dose to solid water for comparison with FC 65 ionisation chamber measurements in water. Measurements made during the period December 2006 to June 2008 are considered for evaluation. Uncorrected ionization readings of EC for all the radiation beams over the entire period were within 2% showing the consistency of measurements. Absorbed doses estimated by EC were in good agreement with in-water calibrations within 2% for photons and electron beams. The present results suggest that extrapolation chambers can be considered as an independent measuring system for absorbed dose in addition to Farmer type ion chambers. In the absence of standard beam quality (Co-60 radiations as reference Quality for Nd,water) the possibility of keeping EC as Primary Standards for absorbed dose calibrations in high energy radiation beams from linacs should be explored. As there are neither Standard Laboratories nor SSDL available in our country, we look forward to keep EC as Local Standard for hospital chamber calibrations. We are also participating in the IAEA mailed TLD intercomparison programme for quality audit of existing status of radiation dosimetry in high energy linac beams. The performance of EC has to be confirmed with cobalt-60 beams by a separate study, as linacs are susceptible for minor variations in dose output on different days.

11.
Gulf J Oncolog ; (5): 44-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20084785

RESUMO

Intensity modulated radiotherapy (IMRT) is an advanced form of 3D conformal radiotherapy combining several intensity modulated beams to deliver the prescribed dose to the target with precision, sparing the adjacent normal tissue structures. The complex nature of IMRT delivery needs a precise patient specific quality assurance (QA), proper verification of dosimetry and treatment. QA procedures are important measures to ensure that the treatment can be delivered according to the treatment plan. In this report, we are presenting a formulation of a proposed protocol and results of patient specific QA carried on two IMRT plans. The QA consists of an absolute dosimetry, film dosimetry and dynalog files verification of treatment plans. The absolute doses, planar and fluence doses calculated by the TPS are compared with the measured values. The dynalog files recorded during the treatment delivery of two plans were analysed. The measured error in absolute dose is <3% in both the plans. An average of >98% of counts are having <0.1 cm errors in dMLC positions. The average RMS value of leaf motions is <0.05 cm in both the cases. The errors in film dosimetry are <3%. All the results obtained are comparable to the standard values and well within the acceptable limits. The paper outlines the minimum procedures required for the patient specific QA measurements for the clinical implementation of IMRT. The measurements help to understand and confirm the accuracy of IMRT delivery system.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas
12.
J Med Phys ; 33(2): 49-53, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19893690

RESUMO

The objective of this study was to conduct an audit on QA aspects of treatment delivery by the verification of the treatment fields' position on different days to document the efficiency of immobilization methods and reproducibility of treatment. A retrospective study was carried out on 60 patients, each 20 treated for head and neck, breast, and pelvic sites; and a total of 506 images obtained by electronic portal imaging device (EPID) were analyzed. The portal images acquired using the EPID systems attached to the Varian linear accelerators were superimposed on the reference images. The anatomy matching software (Varian portal Vision. 6.0) was used, and the displacements in two dimensions and rotation were noted for each treated field to study the patient setup errors. The percentages of mean deviations more than 3 mm in 'lateral (X) and longitudinal (Y)' directions were 17.5%, 11.25%, and 7.5% for breast, pelvis, and head and neck cases respectively. In all cases, the percentage of mean deviation with more than 5 mm error was 0.83%. The maximum average mean deviation in all the cases was 1.87. The average mean SD along X and Y directions in all the cases was less than 2.65. The results revealed that the ranges of setup errors are site specific and immobilization methods improve reproducibility. The observed variations were well within the limits. The study confirmed the accuracy and quality of treatments delivered to the patients.

13.
J Med Phys ; 33(2): 60-3, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19893692

RESUMO

3 Dimensional Conformal Radiotherapy (3D-CRT) planning software helps in displaying the 3D dose distribution at different levels in the planned target volume (PTV). Physical or dynamic wedges are commonly applied to obtain homogeneous dose distribution in the PTV. Despite all these planning efforts, there are about 10% increased dose hot spots encountered in final plans. To overcome the effect of formation of hot spots, a manual forward planning method has been used. In this method, two more beams with multi-leaf collimator (MLC) of different weights are added in addition to medial and lateral wedged tangent beams. Fifteen patient treatment plans were taken up to check and compare the validity of using additional MLC fields to achieve better homogeneity in dose distributions. The resultant dose distributions with and without presence of MLC were compared objectively. The dose volume histogram (DVH) of each plan for the PTV was evaluated. The 3D dose distributions and homogeneity index (HI) values were compared. The 3D dose maximum values were reduced by 4% to 7%, and hot spots assumed point size. Optimizations of 3D-CRT plans with MLC fields improved the homogeneity and conformability of dose distribution in the PTV. This paper outlines a method of obtaining optimal 3D dose distribution within the PTV in the 3D-CRT planning of breast cases.

14.
J Med Phys ; 33(2): 64-71, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19893693

RESUMO

This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique. The various QA tests verified the mechanical and dosimetric stability of the mMLC of linear accelerator when operated in dynamic mode (dMLC). The mechanical QA tests also verified the positional accuracy and kinetic properties of the dMLC. The stability of dMLC was analyzed qualitatively and quantitatively using radiographic film and Omnipro IMRT software. The output stability, variation in output for different sweeping gap widths, and dosimetric leaf separation were measured. Dose delivery with IMRT was verified against the dose computed by the treatment planning system (TPS). Monitor units (MUs) calculated by the planning system for the IMRT were cross-checked with independent commercial dose management software. Visual inspection and qualitative analysis showed that the leaf positioning accuracy was well within the acceptable limits. Dosimetric QA tests confirmed the dosimetric stability of the mMLC in dynamic mode. The verification of MUs using commercial software confirmed the reliability of the IMRT planning system for dose computation. The dosimetric measurements validated the fractional dose delivery.

15.
J Med Phys ; 33(3): 127-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19893703

RESUMO

Intensity-modulated radiotherapy (IMRT) clinical dose delivery is based on computer-controlled multileaf movements at different velocities. To test the accuracy of modulation of the beam periodically, quality assurance (QA) methods are necessary. Using a cylindrical phantom, dose delivery was checked at a constant geometry for sweeping fields. Repeated measurements with an in-house designed methodology over a period of 1 year indicate that the method is very sensitive to check the proper functioning of such dose delivery in medical linacs. A cylindrical perspex phantom with facility to accurately position a 0.6-cc (FC 65) ion chamber at constant depth at isocenter, (SA 24 constancy check tool phantom for MU check, Scanditronix Wellhofer) was used. Dosimeter readings were integrated for 4-mm, 10-mm, 20-mm sweeping fields and for 3 angular positions of the gantry periodically. Consistency of standard sweeping field output (10-mm slit width) and the ratios of outputs against other slit widths over a long period were reported. A 10-mm sweeping field output was found reproducible within an accuracy of 0.03% (n = 25) over 1 year. Four-millimeter, 20-mm outputs expressed as ratio with respect to 10-mm sweep output remained within a mean deviation of 0.2% and 0.03% respectively. Outputs at 3 gantry angles remained within 0.5%, showing that the effect of dynamic movements of multileaf collimator (MLC) on the output is minimal for angular positions of gantry. This method of QA is very simple and is recommended in addition to individual patient QA measurements, which reflect the accuracy of dose planning system. In addition to standard output and energy checks of linacs, the above measurements can be complemented so as to check proper functioning of multileaf collimator for dynamic field dose delivery.

16.
J Med Phys ; 32(3): 92-6, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21157527

RESUMO

There is need for simple methods for checking consistency of beam outputs and energy in linear accelerators used for radiotherapy. A method was designed by the department using perspex phantom with which the dosimetric data of two medical linear accelerators (Clinac 600 CD, Clinac 2300 CD) were evaluated over a period of 30 months. The efficacy of methods followed was checked. Routine beam consistency checks were designed for photon beams with 15 cm/ 5 cm depth ionizations in perspex phantom and variable depth combinations for electron beams. Calculated ionization ratios were compared with measured values to show their significance. The dose/MU for all radiation beams was maintained within 2% accuracy over the period of 30 months. Clinac 600 CD machine showed decreasing trend of cGy/MU, while Clinac 2300 CD showed increasing trend of cGy/MU over a period, which needed tuning of monitor chamber two times each. Tuning of output to achieve standard value was carried out once, for all electron energies when the output dose/MU exceeded 3%. During one week (June 2005), there were slight changes in electron energy detected using the ratio method, which did not recur anytime afterwards. The methods designed are adequate to find the consistency in the beam output and energies in the radiotherapy linacs.

17.
Br J Haematol ; 129(6): 847-53, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15953014

RESUMO

Type I recessive congenital methaemoglobinaemia (RCM), caused by the reduced form of nicotinamide adenine dinucleotide (NADH)-cytochrome b(5) reductase (cytb(5)r) deficiency, manifests clinically as cyanosis without neurological dysfunction. Two mutations, E255- and G291D, have been identified in the NADH-binding lobe of cytb(5)r in previously reported patients, and we have detected a further novel mutation, D239G, in this lobe in two unrelated Irish families. Although one family belongs to the genetically isolated Traveller Community, which separated from the general Irish population during the 1845-48 famine, the D239G mutation was present on the same haplotype in both families. Three known cytb(5)r mutations were also identified, including the R159- mutation, which causes loss of the entire NADH-binding lobe and had previously been reported in an individual with type II RCM. Characterization of the three NADH-binding lobe mutants using a heterologous expression system revealed that all three variants retained stoichiometric levels of flavin adenine dinucleotide with spectroscopic and thermodynamic properties comparable with those of native cytb(5)r. In contrast to the E255- and G291D variants, the novel D239G mutation had no adverse impact on protein thermostability. The D239G mutation perturbed substrate binding, causing both decreased specificity for NADH and increased specificity for NADPH. Thus cytb(5)r deficient patients who are heterozygous for an NADH-binding lobe mutation can exhibit the clinically less severe type I phenotype, even in association with heterozygous deletion of the NADH-binding lobe.


Assuntos
Citocromo-B(5) Redutase/genética , Metemoglobinemia/congênito , Metemoglobinemia/genética , Mutação , NAD/metabolismo , Adolescente , Cristalografia por Raios X , Citocromo-B(5) Redutase/química , Citocromo-B(5) Redutase/metabolismo , Feminino , Genes Recessivos , Haplótipos , Humanos , Recém-Nascido , Masculino , Metemoglobinemia/enzimologia , Mutagênese Sítio-Dirigida , Reação em Cadeia da Polimerase/métodos , Termodinâmica
18.
Phys Rev Lett ; 91(21): 212302, 2003 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-14683292

RESUMO

The forward-backward asymmetry in np-->dpi(0), which must be zero in the center-of-mass system if charge symmetry is respected, has been measured to be [17.2+/-8.0(stat)+/-5.5(syst)]x10(-4), at an incident neutron energy of 279.5 MeV. This observable is compared to recent chiral effective field theory calculations, with implications regarding the du quark mass difference.

19.
Cardiovasc Surg ; 9(6): 565-70, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11604339

RESUMO

Calciphylaxis is a rare syndrome characterized by progressive vascular calcification and ischemic tissue loss in patients with chronic renal failure. We report our five-year experience with five patients who developed foot gangrene due to calciphylaxis. All five patients had characteristic clinical, laboratory, and radiologic findings of the disorder, but no diagnostic variable was uniformly present. All five had progressed to advanced gangrene at the time of surgical consultation. Despite aggressive local attempts to control infection, all five patients died of septic complications. Parathyroidectomy was performed in three patients but did not alter the course in any case. This small experience suggests that the outcome of foot gangrene associated with calciphylaxis is predicated on the degree of tissue loss. Aggressive local wound care does not appear to be adequate to control infection in patients who have already developed gangrene. Although parathyroidectomy may have important long-term advantages in patients with calciphylaxis, it does not appear to affect outcome in these advanced cases.


Assuntos
Calciofilaxia/complicações , Pé/patologia , Falência Renal Crônica/complicações , Adulto , Calciofilaxia/patologia , Calciofilaxia/cirurgia , Feminino , Gangrena , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Paratireoidectomia , Prognóstico , Diálise Renal , Úlcera Cutânea/etiologia , Úlcera Cutânea/patologia
20.
Learn Mem ; 8(5): 272-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11584074

RESUMO

Plasticity in dendritic spines may underlie learning and memory. Spinophilin, a protein enriched in dendritic spines, has the properties of a scaffolding protein and is believed to regulate actin cytoskeletal dynamics affecting dendritic spine morphology. It also binds protein phosphatase-1 (PP-1), an enzyme that regulates dendritic spine physiology. In this study, we tested the role of spinophilin in conditioned taste aversion learning (CTA) using transgenic spinophilin knockout mice. CTA is a form of associative learning in which an animal rejects a food that has been paired previously with a toxic effect (e.g., a sucrose solution paired with a malaise-inducing injection of lithium chloride). Acquisition and extinction of CTA was tested in spinophilin knockout and wild-type mice using taste solutions (sucrose or sodium chloride) or flavors (Kool-Aid) paired with moderate or high doses of LiCl (0.15 M, 20 or 40 mL/kg). When sucrose or NaCl solutions were paired with a moderate dose of LiCl, spinophilin knockout mice were unable to learn a CTA. At the higher dose, knockout mice acquired a CTA but extinguished more rapidly than wild-type mice. A more salient flavor stimulus (taste plus odor) revealed similar CTA learning at both doses of LiCl in both knockouts and wild types. Sensory processing in the knockouts appeared normal because knockout mice and wild-type mice expressed identical unconditioned taste preferences in two-bottle tests, and identical lying-on-belly responses to acute LiCl. We conclude that spinophilin is a candidate molecule required for normal CTA learning.


Assuntos
Aprendizagem da Esquiva/fisiologia , Proteínas dos Microfilamentos/genética , Proteínas dos Microfilamentos/fisiologia , Proteínas do Tecido Nervoso/genética , Proteínas do Tecido Nervoso/fisiologia , Paladar/genética , Paladar/fisiologia , Animais , Cloreto de Lítio/farmacologia , Cloreto de Lítio/toxicidade , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA