Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Med ; 10(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34441825

RESUMO

Selecting patients with a high chance of endured benefit from transcatheter aortic valve implantation (TAVI) is becoming relevant with changing indications and increasing number of TAVI being performed. The aim of our study was to investigate the association of the multidimensional prognostic index (MPI) based on a comprehensive geriatric assessment (CGA) on survival. The TAVI Care & Cure program is a prospective, observational registry of patients referred for TAVI at the Erasmus MC University Medical Center. Consecutive patients who underwent a complete CGA and TAVI were included. CGA components were used to calculate the MPI score. The impact of the MPI score on survival was evaluated using Cox regression. Furthermore, 376 patients were included, 143 (38.0%) patients belonged to the MPI-1 group and 233 (61.9%) patients to the MPI-2-3 group. After 3 years, 14.9% of the patients in the MPI-1 group and 30.5% of the patients in the MPI-2-3 group died (p = 0.001). Patients in MPI-1 had increased chances of overall survival in comparison with patients in MPI group 2-3 Hazard Ratio (HR) 0.57, (95% Confidence Interval (CI) 0.33-0.98)). In this study we found that the MPI tool could be useful to assess frailty and to predict which patient will have a higher chance of enduring benefit from a TAVI procedure.

2.
Age Ageing ; 49(6): 989-994, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32421189

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI. METHODS: The TAVI Care & Cure Program is an ongoing, prospective, observational study including patients referred for TAVI to our institution. A comprehensive geriatric assessment was performed to evaluate existence of frailty using the Erasmus Frailty Score (EFS). HRQoL was assessed using the EQ-5D-5 L at baseline and 1 year after TAVI. RESULTS: 239 patients underwent TAVI and completed HRQoL assessment 1 year after TAVI. Seventy (29.3%) patients were classified as frail (EFS ≥ 3). In non-frail patients, the EQ-5D-5 L index did not change (0.71(± 0.22) to 0.68(± 0.33) points, P = 0.22); in frail patients, the EQ-5D-5 L index decreased from 0.55(±0.26) to 0.44 points (±0.33) (P = 0.022). Frailty was an independent predictor of deteriorated HRQoL 1 year after TAVI (OR 2.24, 95% CI 1.07-4.70, P = 0.003). In frail patients, the absence of peripheral artery disease (OR 0.17, 95% 0.05-0.50, P = 0.001) and renal dysfunction (OR 0.13, 95% CI 0.04-0.41, P = <0.001) at baseline was associated with improved HRQoL 1 year after TAVI. CONCLUSION: Frailty is associated with deterioration of HRQoL 1 year after TAVI. Notably, HRQoL did improve in frail patients with no peripheral arterial disease or renal impairment at baseline.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Idoso Fragilizado , Fragilidade/diagnóstico , Humanos , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Age Ageing ; 49(3): 389-394, 2020 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-32091096

RESUMO

BACKGROUND: delirium is an event leading to negative health outcomes and increased mortality in patients. The aim of this study is to investigate the incidence, determinants and consequences of post-operative delirium (POD) in older patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: The TAVI Care and Cure program is a prospective, observational registry in patients referred for TAVI at Erasmus University Medical Centre. The presence of delirium was evaluated by daily clinical assessment by a geriatrician pre- and up to 3 days post-TAVI. Mortality data were obtained from the Dutch Civil Registry. RESULTS: A total of 543 patients underwent TAVI between January 2014 and December 2017. Overall, the incidence of POD was 14% (75/543 patients) but declined from 18% in 2014 to 7% in 2017 (P = 0.009). Patients who developed POD were older (81.9 ± 5.8 versus 78.6 ± 8.3 years, P < 0.001), had higher prevalence of renal dysfunction and prior stroke (54% versus 40%, P = 0.02; 31% versus 18%, P = 0.01) and were more often frail (32% versus 25%, P = 0.02). From a procedural perspective, general anesthesia (odds ratios (OR), 2.31; 95% CI, 1.40-3.83; P = 0.001), non-transfemoral access (OR, 2.37; 95% CI, 1.20-4.70; P = 0.01) and longer procedural time (OR, 1.01; 95% CI, 1.01-1.02; P < 0.001) were significantly associated with POD. One-year survival rate was 68% among patients who had suffered a POD and was 85% in patients without a POD (hazard ratio's 1.8 (95% CI 1.01-3.10), P = 0.045). CONCLUSION: POD frequently occurs after TAVI and is associated with increased mortality. It might be speculated that patient selection and the minimalistic approach of TAVI may reduce the frequency of delirium.


Assuntos
Estenose da Valva Aórtica , Delírio , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Delírio/diagnóstico , Delírio/epidemiologia , Humanos , Incidência , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Circ Cardiovasc Interv ; 13(1): e008372, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31937136

RESUMO

BACKGROUND: In aortic stenosis, valvulo-arterial impedance (Zva) estimates the overall left ventricular afterload (valve and arterial component). We investigated the association of Zva (≥5 versus <5 mm Hg mL-1 m-2) on quality of life (QOL) and exercise performance (EP) ≥1 year after transcatheter aortic valve replacement (TAVR). METHODS: The study population consists of 250 TAVR patients in whom baseline Zva and follow-up QOL was prospectively assessed using EuroQOL-5-dimensions instruments; EP was assessed in 192 patients who survived ≥1 year after TAVR using questionnaires related to daily activities. In 124 patients, Zva at 1-year was also available and was used to study the change in Zva (baseline to 1 year) on QOL/EP. RESULTS: Elevated baseline Zva was present in 125 patients (50%). At a median of 28 (IQR, 17-40) months, patients with elevated baseline Zva were more limited in mobility (88% versus 71%; P=0.004), self-care (40% versus 25%; P=0.019), and independent daily activities (taking a shower: 53% versus 38%, P=0.030; walking 100 meter: 76% versus 54%, P=0.001; and walking stairs: 74% versus 54%, P=0.011). By multivariable analysis, elevated Zva predicted unfavorable QOL (lower EuroQOL-5-dimensions-Utility Index, odds ratio, 1.98; CI, 1.15-3.41) and unfavorable EP (any limitation in ≥3 daily activities, odds ratio, 2.55; CI, 1.41-4.62). After TAVR, the proportion of patients with elevated Zva fell from 50% to 21% and remained 21% at 1 year and was found to be associated with more limitations in mobility, self-care, and daily activities compared with patients with Zva <5 mm Hg mL-1 m-2. CONCLUSIONS: Elevated Zva was seen in half of patients and predicted unfavorable long-term QOL and EP. At 1 year after TAVR, the prevalence of elevated Zva was 21% but remained associated with poor QOL/EP.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Tolerância ao Exercício , Hemodinâmica , Qualidade de Vida , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Inquéritos e Questionários , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Int J Cardiol ; 302: 36-41, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31859111

RESUMO

BACKGROUND: The capacity of TAVI-programs and numbers of sites performing TAVI has rapidly increased. This necessitated the initiation of the Rotterdam TAVI Care & Cure Program, aiming to improve patient-centered care during the TAVI pathway. METHODS: Consenting patients with severe aortic stenosis and an indication for TAVI will be included. The TAVI Care & Cure program will facilitate prognostic contributions to improve outcomes, patient satisfaction and quality of life in patients with valvular heart disease who are treated with a transcatheter aortic valve implantation in collaboration with the departments of cardiology, cardio-thoracic surgery, anesthesiology and geriatrics. CONCLUSION: With a single center observational registry, we aim to assess the TAVI patient clinical pathway, focusing on pre, peri and post interventional variables including functional status and HRQoL. We will evaluate the patient's complexity by applying an extended multidisciplinary approach, which includes a systematic application of geriatric assessments of frailty and cognitive function.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fragilidade/complicações , Avaliação Geriátrica , Qualidade de Vida , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Feminino , Fragilidade/psicologia , Humanos , Masculino , Países Baixos , Resultado do Tratamento
6.
Int J Cardiol ; 276: 48-52, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30409734

RESUMO

BACKGROUND: Frailty in patients undergoing Transcatheter Aortic Valve Implantation (TAVI) has been associated with an increased 1-year mortality rate but the relation of frailty and short term outcomes yields conflicting results. This study investigated the association of a novel and self-developed Erasmus Frailty Score with both short and long term outcomes after TAVI. METHODS: TAVI Care & Cure is an observational ongoing study, which includes consecutive patients undergoing TAVI at the Erasmus University Medical Centre. Prior to the TAVI, frailty status was assessed. The Erasmus Frailty Score (EFS) was defined as follows: 1 point assigned if: MMSE was <27 points, MUST ≥2 points, grip strength <20 kg for females, <30 kg for males, KATZ index ≥1 limited activity, Lawton and Brody index ≥2 limited activity. The maximum score was 5. Patients were classified as frail when the score was ≥3. Presence of delirium was evaluated by daily clinical assessment by a geriatrician pre- and post-TAVI. Mortality data were obtained from the Dutch Civil Registry. The impact of frailty on short and long term outcomes was evaluated. RESULTS: 213 patients were included for analysis. Frailty was present in 28.6% (n = 61), (EFS ≥ 3). Baseline frailty was associated with patients developing a delirium [OR 3.3 (95% CI 1,55-7,10), p = 0.002] and with increased risk of 1-year mortality [HR 2.1 (95% CI 1.01-4.52), p = 0.047]. CONCLUSION: The Erasmus Frailty Score is associated with delirium and 1 year mortality in older patients after TAVI and can be used as a complement to traditional risk factors.


Assuntos
Estenose da Valva Aórtica/mortalidade , Delírio/mortalidade , Idoso Fragilizado , Fragilidade/mortalidade , Avaliação Geriátrica/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Delírio/diagnóstico , Delírio/cirurgia , Feminino , Fragilidade/diagnóstico , Fragilidade/cirurgia , Humanos , Masculino , Mortalidade/tendências , Fatores de Risco , Substituição da Valva Aórtica Transcateter/tendências
7.
Ned Tijdschr Geneeskd ; 158: A7768, 2014.
Artigo em Holandês | MEDLINE | ID: mdl-25308222

RESUMO

Aortic valve stenosis is a common heart valve disorder in adults. Its prevalence increases with age and is therefore especially seen in older patients. Thirty to forty per cent of patients with symptomatic aortic valve stenosis are not referred for surgical valve replacement because of high age, their medical history or comorbidities. In 2002, the first transcatheter aortic valve implantation (TAVI) was carried out in an inoperable patient. Since 2012, TAVI has been included in international guidelines for heart valve diseases as a treatment strategy in symptomatic patients at a high risk of complications and a life expectancy of more than one year. Decision-making about which treatment is preferable takes a multidisciplinary approach. Important complications of TAVI are bleeding, renal function disorder, stroke, conduction abnormalities, valve insufficiency and death. TAVI procedures are carried out in the Netherlands only in cardiac centres in which specific expertise is present in the areas of structural cardiovascular disease. Scientific research is important for further developments and improvements.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco , Humanos , Países Baixos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA