Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 57(7): 1026-1034, 2019 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-30838831

RESUMO

Introduction Dried blood spot (DBS) sample applications now encompass analytes related to clinical diagnosis, epidemiological studies, therapeutic drug monitoring, pharmacokinetic and toxicokinetic studies. Haematocrit (Hct) and haemoglobin (Hb) at very high or low concentrations may influence the accuracy of measurement quantification of the DBS sample. In this study, we aimed to predict the Hct of the punched DBS through primary spectrophotometric estimation of its haemoglobin-derivative (Hb-drv) content. Methods Formic acid solution was used to elute Hb-drv content of 3.2 mm spotted blood from its dry matrix. Direct spectrometry measurement was utilised to scan the extracted Hb-drv in the visible spectrum range of 520-600 nm. The linear relationship between an individual's Hct percentage and Hb-drv concentration was applied to estimate the Hct level of the blood spot. De-identified whole blood samples were used for the method development and evaluation studies. Results The Hb-drv estimation is valid in samples >2 months old. Method validation experiments DBS demonstrate linearity between 82.5 and 207.5 g/L, average coefficient of variation of 3.6% (intra-assay) and 7.7% (inter-assay), analytical recovery of 84%, and a high positive correlation (r=0.88) between Hb-drv and the original whole blood Hct. The Bland-Altman difference plot demonstrates a mean difference of 2.4% between the calculated DBS Hct and the directly measured Hct from fresh whole bloods. Conclusions We have successfully developed a simple Hb-drv method to estimate Hct in aged DBS samples. This method can be incorporated into DBS analytical work-flow for the in-situ estimation of Hct and subsequent correction of the analyte of interest as required.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Hemoglobinas/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Calibragem , Criança , Pré-Escolar , Formiatos/química , Hematócrito/normas , Hemoglobinas/normas , Humanos , Lactente , Pessoa de Meia-Idade , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrofotometria , Fatores de Tempo , Adulto Jovem
2.
Thromb Haemost ; 95(2): 362-72, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16493500

RESUMO

Developmental haemostasis is a concept, now universally accepted, introduced by Andrew et al. in the late 1980's. However, coagulation analysers and reagents have changed significantly over the past 15 years. Coagulation testing is known to be sensitive to changes in individual reagents and analysers. We hypothesised that the reference ranges developed by Andrew et al. may not be appropriate for use in a modern coagulation laboratory. Our study was designed to determine whether a current day coagulation testing system (STA Compact analyser and Diagnostica Stago reagent system) was sensitive to age-related changes in coagulation assays. This is the first large scale study since Andrew et al. to determine the age associated numerical changes in coagulation proteins. Our results confirm the concepts of developmental haemostasis elucidated by Andrew et al. However, our results clearly demonstrate that the absolute values of reference ranges for coagulation assays in neonates and children vary with analyser and reagent systems. The results confirm the need for coagulation laboratories to develop age-related reference ranges specific to their own testing systems. Without this, accurate diagnosis and management of neonates and children with suspected bleeding or clotting disorders is not possible. Finally we present age related reference ranges for D-dimers, TFPI, and endogenous thrombin potential, previously not described.


Assuntos
Testes de Coagulação Sanguínea/normas , Hemostasia , Desenvolvimento Humano/fisiologia , Adolescente , Adulto , Fatores Etários , Testes de Coagulação Sanguínea/instrumentação , Criança , Pré-Escolar , Técnicas de Laboratório Clínico , Produtos de Degradação da Fibrina e do Fibrinogênio/normas , Humanos , Lactente , Recém-Nascido , Laboratórios Hospitalares , Lipoproteínas/normas , Valores de Referência , Trombina/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA