Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Med ; 64(7): 1087-1092, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37116915

RESUMO

Conventional MRI has important limitations when assessing for progression of disease (POD) versus treatment-related changes (TRC) in patients with malignant brain tumors. We describe the observed impact and pitfalls of implementing 18F-fluoroethyltyrosine (18F-FET) perfusion PET/MRI into routine clinical practice. Methods: Through expanded-access investigational new drug use of 18F-FET, hybrid 18F-FET perfusion PET/MRI was performed during clinical management of 80 patients with World Health Organization central nervous system grade 3 or 4 gliomas or brain metastases of 6 tissue origins for which the prior brain MRI results were ambiguous. The diagnostic performance with 18F-FET PET/MRI was dually evaluated within routine clinical service and for retrospective parametric evaluation. Various 18F-FET perfusion PET/MRI parameters were assessed, and patients were monitored for at least 6 mo to confirm the diagnosis using pathology, imaging, and clinical progress. Results: Hybrid 18F-FET perfusion PET/MRI had high overall accuracy (86%), sensitivity (86%), and specificity (87%) for difficult diagnostic cases for which conventional MRI accuracy was poor (66%). 18F-FET tumor-to-brain ratio static metrics were highly reliable for distinguishing POD from TRC (area under the curve, 0.90). Dynamic tumor-to-brain intercept was more accurate (85%) than SUV slope (73%) or time to peak (73%). Concordant PET/MRI findings were 89% accurate. When PET and MRI conflicted, 18F-FET PET was correct in 12 of 15 cases (80%), whereas MRI was correct in 3 of 15 cases (20%). Clinical management changed after 88% (36/41) of POD diagnoses, whereas management was maintained after 87% (34/39) of TRC diagnoses. Conclusion: Hybrid 18F-FET PET/MRI positively impacted the routine clinical care of challenging malignant brain tumor cases at a U.S. institution. The results add to a growing body of literature that 18F-FET PET complements MRI, even rescuing MRI when it fails.


Assuntos
Neoplasias Encefálicas , Humanos , Estudos Retrospectivos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Progressão da Doença , Imageamento por Ressonância Magnética/métodos , Perfusão , Tomografia por Emissão de Pósitrons/métodos , Tirosina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA