Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
BMJ Case Rep ; 17(7)2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39025798

RESUMO

Laparoscopic intraperitoneal onlay mesh repair is favoured for diaphragmatic hernias due to better outcomes. However, fixation devices pose risks, including cardiac tamponade. A man underwent laparoscopic repair for a large diaphragmatic hernia. One week later, he presented with chest discomfort which was initially attributed to postoperative pain. Subsequently, patient represented with worsening of chest pain and tachycardia. CT requested to rule out pulmonary embolism revealed a large pericardial effusion. Urgent drainage via apical approach resolved tamponade. The case highlights the challenges in managing pericardial effusions post-laparoscopy in the presence of diaphragmatic mesh and stresses multidisciplinary collaboration. Literature review highlights risks associated with fixation devices. Suggestions include limiting their use near vital structures. Key learning point of this case report is to raise awareness of cardiac tamponade following diaphragmatic hernia repair. Limited evidence necessitates cautious use of fixation devices, emphasising patient safety.


Assuntos
Tamponamento Cardíaco , Hérnia Diafragmática , Laparoscopia , Humanos , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Laparoscopia/efeitos adversos , Masculino , Hérnia Diafragmática/cirurgia , Hérnia Diafragmática/diagnóstico por imagem , Hérnia Diafragmática/etiologia , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/etiologia , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Derrame Pericárdico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Dor no Peito/etiologia , Drenagem/métodos , Pessoa de Meia-Idade
5.
Adv Clin Exp Med ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38934334

RESUMO

BACKGROUND: The path and interaction of leads within the cardiovascular system are influenced by various factors, including the implantation technique. Furthermore, the multifaceted composition of these leads, often comprising multiple materials, can contribute to their potential degradation and wear over time. OBJECTIVES: Our aim was to investigate the wear of lead insulation following the removal of transvenous leads and pinpoint the regions of the lead most vulnerable to damage. MATERIAL AND METHODS: We undertook a prospective analysis of patients from a single tertiary center who underwent transvenous lead explantation (TLE) between October 1, 2013, and July 31, 2015. Specifically, our examination focused on endocardial leads removed using simple screw-out and gentle traction techniques. Subsequent lead evaluations were conducted utilizing scanning electron and optical microscopes. RESULTS: Among the 86 patients who underwent the TLE procedure, 26 patients (30%) required the removal of 39 leads through simple traction. Inspection using scanning electron microscopy consistently indicated insulation damage across all leads. A total of 347 damaged sites were identified: 261 without lead unsealing and 86 exhibiting unsealing. Notably, the sections of the leads located within the intra-pocket area demonstrated the highest vulnerability to damage (odds ratio (OR): = 9.112, 95% confidence interval (95% CI): 3.326-24.960), whereas the intravenous regions displayed the lowest susceptibility (OR: 0.323, 95% CI: 0.151-0.694). CONCLUSIONS: Our study reveals that all evaluated leads exhibited insulation damage, with the intra-pocket segments manifesting a notably higher prevalence of damage than the intravenous segments.

7.
Eur J Prev Cardiol ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381595

RESUMO

BACKGROUND: Long COVID syndrome has had a major impact on million patients' lives worldwide. The cardiovascular system is an important aspect of this multifaceted disease that may manifest in many ways. We have hereby performed a narrative review in order to identify the extent of the cardiovascular manifestations of the Long COVID syndrome. METHODS AND RESULTS: An in-depth systematic search of the literature has been conducted for this narrative review. The systematic search of PubMed and Cochrane databases yielded 3,993, of which 629 underwent full text screening. A total of 78 studies were included in the final qualitative synthesis and data evaluation. The pathophysiology of the cardiovascular sequelae of Long COVID syndrome and the cardiac manifestations and complications of Long COVID syndrome are critically evaluated. In addition, potential cardiovascular risk factors are assessed, and preventive methods and treatment options are examined in this review. CONCLUSIONS: This systematic review poignantly summarises the evidence from the available literature regarding the cardiovascular manifestations of Long COVID syndrome and reviews potential mechanistic pathways, diagnostic approaches, preventive measures and treatment options.

8.
Clin Med (Lond) ; 23(6): 594-605, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38065591

RESUMO

Recent randomised trials have shown that clinical outcomes with transcatheter aortic valve implantation (TAVI) are non-inferior to surgical aortic valve replacement (SAVR) in patients with symptomatic aortic stenosis at intermediate to low risk. Health-related quality of life (HrQoL) outcomes in these patient groups remain uncertain. A systematic search of the literature was conducted that included nine trials and 11,295 patients. Kansas City Cardiomyopathy Questionnaire (KCCQ), a heart-failure-specific measure and EuroQol-5D (EQ-5D) (a generic health status tool) changes were the primary outcomes. New York Heart Association (NYHA) classification was the secondary outcome. Improvement in KCCQ scores was greater with TAVI (mean difference (MD)=13.56, 95% confidence interval (CI) 11.67-15.46, p<0.001) at 1 month, as was the improvement in EQ-5D (MD=0.07, 95% CI 0.05-0.08, p<0.001). There was no difference in KCCQ (MD=1.05, 95% CI -0.11 to 2.21, p=0.08) or EQ-5D (MD=-0.01, 95% CI -0.03 to 0.01), p=0.37) at 12 months. NYHA functional class 3/4 was lower in patients undergoing TAVI at 1 month (MD=0.51, 95% CI 0.34-0.78, p=0.002), but there was no difference at 12 months (MD=1.10; 95% CI 0.87-1.38, p=0.43). Overall, TAVI offers early benefit in HRQoL outcomes compared with SAVR, but they are equivalent at 12 months.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Risco , Resultado do Tratamento , Fatores de Risco
9.
Echocardiography ; 40(10): 1068-1078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632153

RESUMO

BACKGROUND: His bundle pacing (HBP) has proved to be a valuable alternative enabling the physiological activation of cardiac contraction in cardiac resynchronization therapy (CRT). At present, however, little is known about the optimal method of programming of the His bundle-paced CRT systems in terms of achieving the best cardiac output. AIM: The aim of this study was to evaluate the impact of cardiac resynchronization therapy with conduction system pacing (CRT+CSP) on echo-based hemodynamic parameters in the early post-operative measurements. METHODS: The study enrollment criteria included: permanent atrial fibrillation, heart failure and bundle branch block. All patients underwent implantation of CRT + HBP. During the post-operative phase, we aimed to optimize HOT-CRT settings in order to achieve the greatest cardiac output assessed by complex echocardiographic measurements. RESULTS: The study included 21 patients, mean age 71.2 (6.3) years, predominantly men (71.4%) with non-ischemic cardiomyopathy 62%. All patients had heart failure with NYHA functional class III and IV (81%). Mean left ventricular ejection fraction was 27.5 (9.7%). The mean duration of the QRS complex was 148.8 ms. The effects of resynchronization pacing: HBP alone, HBP with left ventricular pacing, HBP with biventricular pacing (BiV) and BiV without HBP ​​were analyzed consecutively. HBP combined with left ventricular pacing demonstrated the best hemodynamic response. CONCLUSION: His bundle pacing coupled with LV pacing proved to be the most advantageous pacing program setting with regard to cardiac output. Moreover, it performed better than biventricular pacing and significantly better than RV pacing.

12.
Pol Arch Intern Med ; 133(12)2023 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-37227294

RESUMO

INTRODUCTION: Single atrial stimulation (AAI) has been commonly used for permanent pacing in sick sinus syndrome and significant bradycardia. OBJECTIVE: The study aimed to evaluate long­term AAI pacing and to identify timing and reasons for pacing mode change. PATIENTS AND METHODS: Retrospectively, we included 207 patients (60% women) with initial AAI pacing, who were followed­up for an average of 12 years. RESULTS: At the time of death or loss to follow­up, 71 patients (34.3%) had unchanged AAI pacing mode. The reason for an upgrade of the pacing system was development of atrial fibrillation (AF) in 43 patients (20.78%) and atrioventricular block (AVB) in 34 patients (16.4%). The cumulative ratio for a pacemaker upgrade reoperation reached 2.77 per 100 patient­years of the follow­up. Cumulative ventricular pacing below 10% after an upgrade to dual­chamber pacemaker was observed in 28.6% of the patients. Younger age at implant was the leading independent predictor of the change to dual­chamber simulation (hazard ratio, 1.98; 95% CI, 1.976-1.988; P = 0.001). There were 11 (5%) lead malfunctions that required reoperation. Subclavian vein occlusion was noted in 9 upgrade procedures (11%). One cardiac device-related infection was observed. CONCLUSIONS: The reliability of AAI pacing decreases with each year of observation due to development of AF and AVB. However, in the current era of effective AF treatment, the advantages of AAI pacemakers, such as lower incidence of lead malfunction, venous occlusion, and infection, as compared with dual-chamber pacemakers, may make AAI pacemakers a viable option.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Feminino , Masculino , Síndrome do Nó Sinusal/terapia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Átrios do Coração , Fibrilação Atrial/terapia
13.
JAMA Intern Med ; 183(6): 566-580, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951832

RESUMO

Importance: Post-COVID-19 condition (PCC) is a complex heterogeneous disorder that has affected the lives of millions of people globally. Identification of potential risk factors to better understand who is at risk of developing PCC is important because it would allow for early and appropriate clinical support. Objective: To evaluate the demographic characteristics and comorbidities that have been found to be associated with an increased risk of developing PCC. Data sources: Medline and Embase databases were systematically searched from inception to December 5, 2022. Study Selection: The meta-analysis included all published studies that investigated the risk factors and/or predictors of PCC in adult (≥18 years) patients. Data Extraction and Synthesis: Odds ratios (ORs) for each risk factor were pooled from the selected studies. For each potential risk factor, the random-effects model was used to compare the risk of developing PCC between individuals with and without the risk factor. Data analyses were performed from December 5, 2022, to February 10, 2023. Main Outcomes and Measures: The risk factors for PCC included patient age; sex; body mass index, calculated as weight in kilograms divided by height in meters squared; smoking status; comorbidities, including anxiety and/or depression, asthma, chronic kidney disease, chronic obstructive pulmonary disease, diabetes, immunosuppression, and ischemic heart disease; previous hospitalization or ICU (intensive care unit) admission with COVID-19; and previous vaccination against COVID-19. Results: The initial search yielded 5334 records of which 255 articles underwent full-text evaluation, which identified 41 articles and a total of 860 783 patients that were included. The findings of the meta-analysis showed that female sex (OR, 1.56; 95% CI, 1.41-1.73), age (OR, 1.21; 95% CI, 1.11-1.33), high BMI (OR, 1.15; 95% CI, 1.08-1.23), and smoking (OR, 1.10; 95% CI, 1.07-1.13) were associated with an increased risk of developing PCC. In addition, the presence of comorbidities and previous hospitalization or ICU admission were found to be associated with high risk of PCC (OR, 2.48; 95% CI, 1.97-3.13 and OR, 2.37; 95% CI, 2.18-2.56, respectively). Patients who had been vaccinated against COVID-19 with 2 doses had a significantly lower risk of developing PCC compared with patients who were not vaccinated (OR, 0.57; 95% CI, 0.43-0.76). Conclusions and Relevance: This systematic review and meta-analysis demonstrated that certain demographic characteristics (eg, age and sex), comorbidities, and severe COVID-19 were associated with an increased risk of PCC, whereas vaccination had a protective role against developing PCC sequelae. These findings may enable a better understanding of who may develop PCC and provide additional evidence for the benefits of vaccination. Trial Registration: PROSPERO Identifier: CRD42022381002.


Assuntos
COVID-19 , Adulto , Humanos , Feminino , COVID-19/epidemiologia , Fatores de Risco , Comorbidade , Hospitalização
14.
Europace ; 25(3): 1100-1109, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36660771

RESUMO

AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Resultado do Tratamento , Estudos Retrospectivos
15.
Artigo em Inglês | MEDLINE | ID: mdl-36141583

RESUMO

The purpose of this research is to analyze the shopping behavior of international students (Asian vs. European) studying in Poland. Participants were recruited from universities located in Warsaw between June and September 2020. A total of 806 questionnaires were collected, 87 of which were eliminated due to non-response. The research sample consisted of 719 people. We conducted an exploratory factor analysis and cluster analysis for the entire study population and separately for European and Asian students. In exploratory factor analysis, two factors were extracted for the entire population, while three factors each were extracted for the European and Asian student groups. In cluster analysis, we obtained four clusters each for the entire study population and the group of European and Asian students. Our study found that among Asian students, compared to European students, there was a greater change in shopping behavior during the COVID-19 pandemic, expressed by a greater preference for online shopping, greater purchases of fruits and vegetables, purchases of local products, and shorter shopping time.


Assuntos
COVID-19 , COVID-19/epidemiologia , Comportamento do Consumidor , Humanos , Pandemias , Polônia/epidemiologia , Estudantes , Verduras
16.
J Child Adolesc Trauma ; 15(3): 567-583, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35958724

RESUMO

This study investigated the prevalence of parentification in a nationwide cross-sectional study. There were N = 47,984 Polish adolescents aged 12-21 (M = 15.60; SD = 1.98; female 52.7%, male 47.3%). The results indicated that more adolescents experienced emotional parentification (toward parents 35.9%; toward siblings 25.2%) as compared to instrumental parentification (toward parents 7.2%; toward siblings 15.5%), which is noteworthy, since emotional parentification is the most detrimental form of parentification in USA samples. Overall, 15.5% of the participants reported a sense of injustice related to their family caregiving roles and 61.2% reported satisfaction related to their family caregiving roles. The results are important given the dearth of prevalence studies.

17.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-35471499

RESUMO

OBJECTIVES: Multiple studies have suggested that women have worse outcomes than men following mitral valve (MV) surgery-most of those studies reported on conventional sternotomy (CS) MV surgery. Therefore, we aimed to explore whether or not the minimally invasive mitral valve surgery (MIMVS) approach might mitigate a worse survival in women following MV surgery. METHODS: We identified patients with isolated primary MV operations with or without tricuspid valve repair performed between 2007 and 2019. Patients were propensity score-matched across the MIMVS and CS surgical approaches. Sex was excluded from the matching process to discern whether female patients had a different likelihood of receiving minimally invasive surgery than males. A Cox proportional hazards model was fitted in the matched cohort and adjusted for the imbalance in baseline characteristics using the propensity score. RESULTS: Of 956 patients (417 MIMVS, 539 CS; 424 females), the matched set comprised 342 pairs (684 patients; 296 females) of patients who were well balanced across MIMVS and CS groups with regard to preoperative clinical characteristics. We observed a 47/53% female/male ratio in the CS group and a 39/61% in the MIMVS group, P = 0.054. In both matched groups, women were older than males. A Cox model adjusted for propensity scores showed no survival difference with sex, surgical type or interaction. CONCLUSIONS: Women present to the surgical team at an older age. They appear less likely to be considered for a MIMVS approach than men. Neither sex nor surgical approach was associated with worse survival in a matched sample.


Assuntos
Insuficiência da Valva Mitral , Ferida Cirúrgica , Feminino , Humanos , Masculino , Valva Mitral/cirurgia , Resultado do Tratamento , Esternotomia , Insuficiência da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos
20.
J Electrocardiol ; 72: 1-5, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35219111

RESUMO

Algorithms designed to reduce the right ventricular (RV) pacing burden are widely available in modern dual-chamber implantable pacing devices. These algorithms allow the atrioventricular delay for sensed ventricular events to be longer than for ventricular paced events. However, since these features are unique to pacemaker manufacturers, they often produce unfamiliar electrocardiographic (ECG) appearances that suggest pacemaker dysfunction. We describe a Vp suppression algorithm used in Biotronik dual-chamber pacemakers and implantable cardioverter-defibrillator devices.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Algoritmos , Estimulação Cardíaca Artificial , Eletrocardiografia , Ventrículos do Coração , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA