Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neurol India ; 72(3): 585-589, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-39041977

RESUMO

BACKGROUND AND AIM: In hydrocephalus patients, after ventriculoperitoneal (VP) shunt, decrease in pulsatility index (PI) correlates with decrease in ventricle size. Also, increase in PI is noted in obstructed or malfunctioning VP shunts. However, previous studies were either done in infants and children or included patients of all age groups. Our aim was to compare PI before and after successful VP shunt surgery in adult patients and also the trend of transcranial Doppler (TCD) parameters for 3 days after surgery. MATERIALS AND METHODS: A prospective, observational study was done in 20 adult patients undergoing VP shunt. Clinical features, vitals, Evans index, and TCD parameters were noted in the preoperative period. A computed tomography (CT) head was repeated 4-6 h after surgery, and the position of ventricular end of shunt was confirmed and Evans index was calculated. The vitals and TCD parameters were noted at same time and for the next 2 days. Repeated measures analysis of variance (ANOVA) and paired t-test were uses for statistical analysis. RESULTS: A total of 18 patients were included for statistical analysis. The mean preoperative PI was 1.19 ± 0.24 and the postoperative PI after surgery was 0.97 ± 0.17, 0.97 ± 0.23, and 0.94 ± 0.21 (P = 0.0039) on postoperative day (POD) 1 (POD1), POD2, and POD3, respectively. The mean preoperative value of Evans index was 0.37 ± 0.06 and there was statistically significant (P = < 0.001) reduction to 0.33 ± 0.07 after VP shunt surgery. The change in PI and change in Evans index were found to be positively correlated (r = 0.34 and P = 0.0013). CONCLUSIONS: The decrease in PI after VP shunt surgery correlates with decrease in ventricular size. Any increase in PI in the postoperative period should raise the suspicion of malfunctioning of VP shunt.


Assuntos
Hidrocefalia , Ultrassonografia Doppler Transcraniana , Derivação Ventriculoperitoneal , Humanos , Hidrocefalia/cirurgia , Hidrocefalia/diagnóstico por imagem , Feminino , Masculino , Adulto , Estudos Prospectivos , Pessoa de Meia-Idade , Fluxo Pulsátil/fisiologia , Adulto Jovem , Idoso , Período Pós-Operatório
3.
J Anaesthesiol Clin Pharmacol ; 38(1): 130-136, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35706620

RESUMO

Background and Aims: The supraglottic airway devices (SADs) that allow direct (without an intermediary device like Aintree or airway exchange catheters) tracheal intubation can be invaluable for field use in conditions ideally managed by intubation. Whilst fiberscope-guided intubation is the method of choice, if these 'direct-intubation' SADs could provide high success rates for blind tracheal intubation, their scope of use can increase tremendously. Our study assesses intubating laryngeal mask airway (ILMA), i-gel and Ambu AuraGain for blind tracheal intubation in adults. Material and Methods: Ninety adults undergoing elective surgery were randomized into three equal groups. After induction of anesthesia, the group-specific SAD was inserted and on achieving adequate ventilation, blind tracheal intubation was attempted over two attempts. Success rates and time of achieving adequate device placement and tracheal intubation through these were evaluated. Data were analyzed using SPSS version 17.0 and P < 0.05 was considered statistically significant. Results: All three devices could achieve adequate ventilation within two allowed attempts. Successful tracheal intubation rates were significantly better with ILMA than i-gel on first attempt (87% vs. 27%, P < 0.001) and after second attempt that was supplemented with optimization maneuvers (100% vs. 40%, P < 0.001). No patient could be intubated through Ambu AuraGain within two attempts. Time taken for successful tracheal intubation did not differ significantly (P = 0.205) with ILMA or i-gel. Conclusion: Out of ILMA, I-gel and Ambu AuraGain, ILMA is the best device for blind tracheal intubation in adults with normal airways.

5.
Indian J Anaesth ; 65(6): 439-444, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34248186

RESUMO

BACKGROUND AND AIMS: Postoperative upper airway complications are frequently encountered with the use of supraglottic airway devices (SADs). Cuff pressure is one of the risk factors for upper airway complications with SADs. Among SADs, i-gel has shown lesser incidence. The effect of different cuff pressures on the incidence of postoperative upper airway complications is not known with Ambu AuraGain and nor has Ambu AuraGain been compared with i-gel in this regard. So, we undertook this study. METHODS: A total of 200 patients undergoing elective laparoscopic surgery were randomised into 3 groups based on the SAD used and intra-cuff pressure: i-gel (IG) (n = 66); Ambu AuraGain at 25 cmH2O cuff pressure (AL) (n = 67); and Ambu AuraGain at 60 cmH2O cuff pressure (AH) (n = 67). The oropharyngeal leak pressures (OLPs) were measured after insertion and generation of carboperitoneum. An observer who was blind to the intraoperative details assessed the patients for two postoperative days for sore throat, dysphagia, dysphonia, or any other upper airway complications. RESULTS: The OLPs before and after carboperitoneum in the 3 groups were (IG-24.22 ± 7.87 and 28.31 ± 8.52, AL-24.40 ± 5.84 and 26.94 ± 5.93, AH-25.02 ± 5.02 and 28.91 ± 5.6) cmH2O (P = 0.747 and P = 0.231). The overall incidence of postoperative sore throat among the 3 groups was: IG-5.7%, AL-14.9%, and AH-17.9%; P = 0.135. Dysphagia was seen only with Ambu AuraGain at high pressure in 4 patients (5.97%) (P = 0.017). CONCLUSION: Limiting cuff pressure in Ambu AuraGain to 25, as against 60 cmH2O, does not affect the OLP but has the potential of reducing the incidence of dysphagia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA