Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Nucl Med ; 49(7): 605-609, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38778468

RESUMO

PURPOSE: Data published in the literature concerning the doses received by fetuses exposed to a 18 F-FDG PET are reassuring but were obtained from small and heterogeneous cohorts, and very few data are available concerning the fetal dose received after exposure to both PET and CT. The present study aimed to estimate the fetal dose received following a PET/CT exposure using methods that include anthropomorphic phantoms of pregnant women applied on a large cohort. PATIENTS AND METHODS: This retrospective multicenter study included 18 pregnant patients in the second and third trimesters. For PET exposure, the fetal volume and mean concentration of radioactivity in the fetus were measured by manually drawing regions of interest. Those data, combined with the time-integrated activities of the fetus and the mother's organs, were entered into the OLINDA/EXM software 2.0 to assess the fetal dose due to PET exposure. To estimate the fetal dose received due to CT exposure, 2 softwares were used: CT-Expo (based on geometric phantom models of nonpregnant patients) and VirtualDose (using pregnant patient phantoms). RESULTS: The fetal dose exposure for PET/CT examination in the second trimester ranged from 5.7 to 15.8 mGy using CT-Expo (mean, 11.6 mGy) and from 5.1 to 11.6 mGy using VirtualDose (mean, 8.6 mGy). In the third trimester, it ranged from 7.9 to 16.6 mGy using CT-Expo (mean, 10.7 mGy) and from 6.1 to 10.7 mGy using VirtualDose (mean, 7.6 mGy). CONCLUSIONS: The estimated fetal doses were in the same range of those previously published and are well below the threshold for deterministic effects. Pregnancy does not constitute an absolute contraindication for a clinically justified hybrid 18 F-FDG PET/CT.


Assuntos
Feto , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Doses de Radiação , Humanos , Feminino , Gravidez , Feto/diagnóstico por imagem , Feto/efeitos da radiação , Adulto , Imagens de Fantasmas , Estudos Retrospectivos
2.
Diagn Interv Imaging ; 104(4): 167-177, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36414506

RESUMO

Spectral computed tomography (CT) imaging encompasses a unique generation of CT systems based on a simple principle that makes use of the energy-dependent information present in CT images. Over the past two decades this principle has been expanded with the introduction of dual-energy CT systems. The first generation of spectral CT systems, represented either by dual-source or dual-layer technology, opened up a new imaging approach in the radiology community with their ability to overcome the limitations of tissue characterization encountered with conventional CT. Its expansion worldwide can also be considered as an important leverage for the recent groundbreaking technology based on a new chain of detection available on photon counting CT systems, which holds great promise for extending CT towards multi-energy CT imaging. The purpose of this article was to detail the basic principles and techniques of spectral CT with a particular emphasis on the newest technical developments of dual-energy and multi-energy CT systems.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Fótons
3.
Biomed Pharmacother ; 132: 110865, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33254427

RESUMO

INTRODUCTION: Selective Internal Radiation Therapy (SIRT) is used for the treatment of hepatic tumors. The aim of this retrospective study was to compare two dosimetric approaches based on 99mTc-MAA SPECT/CT and 90Y PET/CT, using Simplicit90Y™ versus the supplier suggested method of activity calculation. MATERIAL AND METHODS: A total of 19 patients underwent 21 SIRT after baseline angiography and 99mTc-MAA SPECT/CT, followed by 90Y PET/CT. Overlap between 99mTc-MAA and 90Y-microspheres was quantified with different thresholds isocontours. The perfused volume and tumor absorbed dose were estimated using Simplicit90Y™ based on SPECT/CT and PET/CT, then compared with the supplier suggested method. These data were related to overall survival to evaluate their prognostic impact. RESULTS: The overlap between PET/CT and SPECT/CT was dependent on thresholds, decreasing with an increasing threshold. The overlap between the 99mTc-MAA and 90Y-microspheres biodistributions versus the tumor distribution on morphological imaging was suboptimal, in particular for small tumor volume. The tumor absorbed dose estimated after 90Y PET/CT was not different from tumor absorbed dose estimated after SPECT/CT. The Perfused lobe absorbed dose was significantly lower while the volume of the perfused lobe was significantly higher when estimated by Simplicit90Y™ compared to the supplier suggested conventional approach. A statistical parameter based on overlap between tumor and 90Y-microspheres distribution as well as tumoral dosimetry was significantly related to the overall survival. CONCLUSION: Post-treatment imaging remains paramount to estimate the irradiation dosimetry, due to an imperfect overlap. The perfused volume could be estimated from functional imaging, given its impact on dosimetry. Finally, survival seems related to tumoral overlap and dosimetry.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/metabolismo , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Masculino , Pessoa de Meia-Idade , Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Radioisótopos de Ítrio/metabolismo
5.
Eur Radiol ; 30(10): 5690-5701, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32361774

RESUMO

OBJECTIVES: To establish national reference levels (RLs) in interventional procedures under CT guidance as required by the 2013/59/Euratom European Directive. METHODS: Seventeen categories of interventional procedures in thoracic, abdominopelvic, and osteoarticular specialties (percutaneous infiltration, vertebroplasty, biopsy, drainage, tumor destruction) were analyzed. Total dose length product (DLP), number of helical acquisitions (NH), and total DLP for helical, sequential, or fluoroscopic acquisitions were recorded for 10 to 20 patients per procedure at each center. RLs were calculated as the 3rd quartiles of the distributions and target values for optimization process (TVOs) as the median. RLs and TVOs were compared with previously published studies. RESULTS: Results on 5001 procedures from 49 centers confirmed the great variability in patient dose for the same category of procedures. RLs were proposed for the DLPs and NHs in the seventeen categories. RLs in terms of DLP and NH were 375 mGy.cm and 2 NH for spinal or peri-spinal infiltration, 1630 mGy.cm and 3 NH for vertebroplasty, 845 mGy.cm and 4 NH for biopsy, 1950 mGy.cm and 8 NH for destruction of tumors, and 1090 mGy.cm and 5 NH for drainage. DLP and NH increased with the complexity of procedures. CONCLUSIONS: This study was the first nationwide multicentric survey to propose RLs for interventional procedures under CT guidance. Heterogeneity of practice in centers were found with different levels of patient doses for the same procedure. The proposed RLs will allow imaging departments to benchmark their practice with others and optimize their protocols. KEY POINTS: • National reference levels are proposed for 17 categories of interventional procedures under CT guidance. • Reference levels are useful for benchmarking practices and optimizing protocols. • Reference levels are proposed for dose length product and the number of helical acquisitions.


Assuntos
Doses de Radiação , Radiografia Intervencionista/normas , Valores de Referência , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Fluoroscopia/métodos , França , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Coluna Vertebral , Inquéritos e Questionários , Tomografia Computadorizada por Raios X/métodos , Vertebroplastia , Adulto Jovem
6.
Eur Radiol ; 28(2): 630-641, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28836026

RESUMO

OBJECTIVES: To describe computed tomography (CT) scanning parameters, volume CT dose index (CTDIvol) and dose-length product (DLP) in paediatric practice and compare them to current diagnostic reference levels (DRLs). METHODS: The survey was conducted in radiology departments of six major university hospitals in France in 2010-2013. Data collection was automatised to extract and standardise information on scanning parameters from DICOM-header files. CTDIvol and DLP were estimated based on Monte Carlo transport simulation and computational reference phantoms. RESULTS: CTDIvol and DLP were derived for 4,300 studies, four age groups and 18 protocols. CTDIvol was lower in younger patients for non-head scans, but did not vary with age for routine head scans. Ratios of 95th to 5th percentile CTDIvol values were 2-4 for most body parts, but 5-7 for abdominal examinations and 4-14 for mediastinum CT with contrast, depending on age. The 75th percentile CTDIvol values were below the national DRLs for chest (all ages) and head and abdominal scans (≥10 years). CONCLUSION: The results suggest the need for a better optimisation of scanning parameters for routine head scans and infrequent protocols with patient age, enhanced standardisation of practices across departments and revision of current DRLs for children. KEY POINTS: • CTDIvol varied little with age for routine head scans. • CTDIvol was lowest in youngest children for chest or abdominal scans. • Individual and inter-department variability warrant enhanced standardisation of practices. • Recent surveys support the need for revised diagnostic reference levels. • More attention should be given to specific protocols (sinuses, neck, spine, mediastinum).


Assuntos
Hospitais Universitários , Imagens de Fantasmas , Exposição à Radiação/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Relação Dose-Resposta à Radiação , Feminino , França , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA