Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Transfus Apher Sci ; 61(2): 103316, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34774438

RESUMO

BACKGROUND: The Blood Donation Service West serves North Rhine-Westphalia (NRW), Rhineland-Palatinate (RP), and Saarland, an area of 56,500 km2. In addition to routine red blood cell concentrates, plasma, and platelets, special products are provided. Since 2014, this has included autologous serum eye drops (ASED) for topical use in patients suffering from different illnesses accompanied by dry eye disease. METHODS: A volume of 250-525 mL of patient blood was collected into an anticoagulant-free blood bag. Laboratory testing included Hepatitis B/C-, HIV 1/2-, and Lues-serology. Coagulation and centrifugation were followed by leukoreduction. Single-use vials were obtained by filling mini-bag systems using a sterile tube welder. Storage at ≤-20 °C enabled a shelf-life of up to 6 months and 30 days at 4 °C after thawing for shipment. RESULTS: Contracts were closed with 15 ophthalmology clinics and medical practices in NRW and RP to supply patients with ASED. The patient pool increased from 19 in 2014 to 46 in 2020, with an average age of 43-55 years. Overall, blood collections almost tripled from 31 to 100 per year, increasing the stock of deliverable single-use vials from 3328 to 13,358. Delivery in a liquid state allowed engagement of 44 pharmacies located in the patient neighborhoods for continuous supply. CONCLUSION: Manufacturing in a closed bag system allowed integration into blood bank operations. However, cost-coverage by health insurance remained a case-by-case decision. Allogeneic application as 'just-another-blood-product' could be an aspiration. Yet, conclusive data from large clinical trials are needed for licensed provision in Germany.


Assuntos
Doadores de Sangue , Transplante de Células-Tronco Hematopoéticas , Adulto , Humanos , Pessoa de Meia-Idade , Soluções Oftálmicas/uso terapêutico , Cruz Vermelha , Soro
2.
Clin Hemorheol Microcirc ; 76(3): 367-379, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32675400

RESUMO

BACKGROUND: Autologous blood doping (ABD) is applied to improve performance capacity. ABD includes blood donation, red blood cell (RBC) storage at -80°C and re-infusion prior to or during competition. ABD is not directly detectable with current detection techniques. OBJECTIVE: Since cryopreservation is known to affect RBC physiology in vitro, the aim of the study was to examine whether these alterations are detectable in vivo. METHODS: Blood from six healthy male donors was transferred into conventional blood bags, cryopreserved, stored for 18 weeks at -80°C and re-infused with a RBC volume corresponding to ∼4% of total blood volume into respective donor. RBC physiology parameters were measured before blood donation/re-infusion, and 0/1/2/6/24/48/72 h and 1 w post re-infusion. RESULTS: RBC parameters and age markers were unaffected during intervention. RBC deformability increased from pre-blood-sampling to pre-re-infusion while deformability and viscosity values remained unaltered post re-infusion. RBC nitric oxide associated analytes, metabolic parameters and electrolyte concentrations remained unaffected. CONCLUSIONS: The data of this pilot study indicate that the increase in RBC deformability might be related to neoformation of RBC after blood donation. The lack of changes in tested parameters might be related to the low re-infused RBC volume which might explain differences to in vitro results.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Criopreservação/métodos , Dopagem Esportivo/métodos , Reologia/métodos , Adulto , Voluntários Saudáveis , Humanos , Masculino , Projetos Piloto
3.
Transfus Med Hemother ; 44(4): 232-239, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28924428

RESUMO

BACKGROUND: We assessed the effect of the uniform donor questionnaire (UDQ) on deferral rates in first-time and repeat donors. We focused on the introduced question about unprotected sexual contact with a new partner. Another goal was a stratified comparison of the deferral rates of the donor questionnaire (DQ) and UDQ. METHODS: Data on donors and deferrals using the DQ and UDQ were collected at four blood establishments. The comparison included a 2-year period by questionnaire version. For the comparison of the questionnaires, an adjusted multinomial logistic regression was performed. RESULTS: The analysis included 260,848 donations. First-time (FTD) and repeat donations (RD) showed higher deferral rates with the UDQ (FTD +5.4%, RD +1.4%). Deferral due to a new partner was 3.0% in first-time and 0.4% in repeat donors. The majority of these occurred in the youngest age groups. The most frequent deferral criterion was 'disease' (5.1%). CONCLUSION: The regression revealed stronger predictors for deferral than the questionnaire version. Especially younger age carried a higher and independent risk for deferral. The additional deferrals of mainly young first-time donors due to a new sexual partner may identify those donors with potential heterosexual risk behavior who would otherwise not be identified.

4.
Blood Transfus ; 12(1): 73-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24333057

RESUMO

BACKGROUND: The Colton blood group antigens Co(a), Co(b) and Co3 are encoded by the AQP1 gene which produces a water channel forming integral protein. The extremely rare Co-deficiency enables immunisation against the Co3 isoantigen. MATERIALS AND METHODS: Four patients from different regions of Europe who belong to the ethnic minority of Romani (Gypsy) presented with irregular antibodies against a high frequency red blood cell antigen. Positive cross-matches with all red blood cells tested were reported. An Anti-Co3 antibody was identified as the cause of incompatibility in the four cases. The genetic background was determined by polymerase chain reaction typing with sequence-specific primers and by DNA sequencing. RESULTS: The Co(a-b-) phenotype was confirmed in the four patients despite the fact that genotyping revealed the CO*01 allele of the AQP1 gene. A homozygous AQP1 c.601delG mutation, leading to a frame shift and producing a premature stop in the next codon, was responsible for the Co-negative phenotype in all four cases. While one patient was successfully transfused with blood from his sibling with the identical mutation, another case, a baby affected by haemolytic disease of the newborn, recovered without transfusion. DISCUSSION: Despite the difficulties in undertaking a population study to determine the prevalence of this AQP1 c.601delG allele in the ethnic minority of Romani, the observations described in this report clearly suggest an accumulation of this mutation, which causes the Co(a-b-) phenotype, in Romani (Gypsy) patients. Further studies are necessary to prove such an accumulation.


Assuntos
Aquaporina 1/genética , Sequência de Bases , Antígenos de Grupos Sanguíneos/genética , Roma (Grupo Étnico)/genética , Deleção de Sequência , Adulto , Análise Mutacional de DNA , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Saudi J Anaesth ; 5(1): 101-4, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21655031

RESUMO

We report on a patient with acute intermittent porphyria, who received 8 AB0 incompatible units of packed red blood cells in an emergency situation. She never showed any signs of severe intravascular haemolysis. The patient died after four weeks because of a multi-organ failure caused from the malpractice of the porphyria. The problems of bedside testing, mixing field reaction, fresh frozen plasma and molecular-genetic determination of bloodgroup were discussed.

6.
Ann Hematol ; 89(1): 83-91, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19484239

RESUMO

Screening of platelet concentrates (PCs) for bacterial contamination with cultivation methods is carried out as a routine procedure in some countries. The aim is to prevent the transfusion of contaminated PCs. The German Evaluation of Regular Monitoring Study Group conducted a prospective multicenter study on 52,243 PCs to investigate the prevalence of bacteria (BacT/ALERT, bioMerieux). This study describes the detected bacterial spectrum, the proportion of PCs with a positive test result that had been transfused, and the results of the clinical follow-up. One hundred thirteen (67%) of 169 potentially or confirmed positive units had already been transfused at the time of the first positive signal. The transfusion of units contaminated by Staphylococcus aureus, Serratia marcescens, and 73% of the units contaminated with Staphylococcus epidermidis, Staphylococcus capitis, or Staphylococcus saccharolyticus was prevented. In contrast, 85% of units with Propionibacterium acnes were transfused. A clonal relationship of the isolates from the pooled PCs and from the associated red blood cell concentrates was found in all investigated cases. The follow-up revealed six febrile reactions to culture-positive PCs not classified as transfusion reaction (TRs) by treating physicians. This demonstrates the importance of hemovigilance. Serious septic reactions due to Klebsiella pneumoniae in two units of one apheresis PC that had tested false-negative were reported; one had a fatal outcome. Culture systems reduce the risk of transfusion of contaminated PCs but cannot guarantee sterility. Physicians must be aware of bacterial contamination of PCs as a potential cause of TRs and must report all adverse events.


Assuntos
Plaquetas/microbiologia , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Transfusão de Plaquetas/normas , Técnicas Bacteriológicas/métodos , Técnicas Bacteriológicas/normas , Seguimentos , Humanos
7.
Transfusion ; 47(4): 644-52, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17381623

RESUMO

BACKGROUND: The GERMS Group initiated a prospective multicenter study to assess prevalence and nature of bacterial contamination of pooled buffy-coat platelet concentrates (PPCs) and apheresis platelet concentrates (APCs) by routine screening with a bacterial culture system. STUDY DESIGN AND METHODS: In nine centers overall, 52,243 platelet (PLT) concentrates (15,198 APCs, 37,045 PPCs) were analyzed by aerobic and anaerobic cultures (BacT/ALERT, bioMérieux). RESULTS: In 135 PLT concentrates (PCs; 0.26%), bacteria could be identified in the first culture (0.4% for APCs vs. 0.2% for PPCs; p < 0.001). In 37 (0.07%) of these PC units, the same bacteria strain could be identified in a second culture from the sample bag and/or the PC unit. The rate of confirmed-positive units did not differ significantly between APC (0.09%; 1/1169) and PPC units (0.06%; 1/1544). Bacteria from skin flora (Propionibacterium acnes, Staphylococcus epidermidis) were the most prevalent contaminants. Median times to first positive culture from start of incubation were 0.7 and 3.7 days in aerobic and anaerobic cultures for confirmed-positive units. With a "negative-to-date" issue strategy, most PC units (55%) had already been issued by time of the first positive culture. CONCLUSION: The rate of confirmed bacterial contamination of PC units was low. Nevertheless, clinicians must be aware of this risk. The risk of bacterial contamination does not warrant universal preference of APCs. It must be questioned whether routine bacterial screening by a culture method can sufficiently prevent contaminated products from being transfused due to the delay until a positive signal in the culture system and due to false-negative results.


Assuntos
Bactérias/isolamento & purificação , Infecções Bacterianas/sangue , Plaquetas/microbiologia , Transfusão de Plaquetas/estatística & dados numéricos , Bactérias/crescimento & desenvolvimento , Infecções Bacterianas/etiologia , Infecções Bacterianas/prevenção & controle , Preservação de Sangue/métodos , Preservação de Sangue/normas , Contagem de Colônia Microbiana , Humanos , Transfusão de Plaquetas/efeitos adversos , Plaquetoferese , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA