Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Braz Oral Res ; 36: e053, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35442382

RESUMO

This study assessed the ability of XP-endo Finisher R (FKG, La Chaux-de-Fonds, Switzerland) to remove filling remnants from curved mesiobuccal canals of maxillary molars, using the passive ultrasonic irrigation (PUI) technique as a comparison. Twenty-four curved main mesiobuccal canals (MB1) of maxillary molars were instrumented with Wave One (#25/07) and filled with gutta-percha points and AH Plus Sealer. Samples were then re-treated with a standardized protocol with Wave One (#35/06) as the master apical file. Micro-CT scans measured baseline volume of remaining filling material (in mm3). Samples were divided into two groups (n = 12) according to the supplementary cleaning approach: (PUI) or XP-endo Finisher R. Statistics compared baseline and final volume of filling material (within-group); and the percentage of filling material reduction (between-group). Mean baseline volumes, final volumes, and percentages of reduction (%) of filling material for XP-endo Finisher R and PUI were respectively: 0.060 mm3, 0.042 mm3, and 31.28%; and 0.064 mm3, 0.054 mm3, and 16.57%. Both tested protocols reduced the amount of filling material (p < 0.05). XP-endo Finisher R had higher percentage of reduction as compared to PUI (p < 0.05). XP-endo Finisher R and PUI used as supplementary cleaning protocols during re-treatment improved the removal of root filling material in curved canals; but XP-endo Finisher R was approximately twice more efficient. The complete filling material removal during re-treatment procedures is still a challenge. Supplementary cleaning protocols may help to remove the remaining material after the complete mechanical preparation of curved canals. XP-endo Finisher R was approximately twice more efficient than PUI.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Retratamento , Materiais Restauradores do Canal Radicular/uso terapêutico , Preparo de Canal Radicular , Ultrassom
2.
Braz. oral res. (Online) ; 36: e053, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1374749

RESUMO

Abstract: This study assessed the ability of XP-endo Finisher R (FKG, La Chaux-de-Fonds, Switzerland) to remove filling remnants from curved mesiobuccal canals of maxillary molars, using the passive ultrasonic irrigation (PUI) technique as a comparison. Twenty-four curved main mesiobuccal canals (MB1) of maxillary molars were instrumented with Wave One (#25/07) and filled with gutta-percha points and AH Plus Sealer. Samples were then re-treated with a standardized protocol with Wave One (#35/06) as the master apical file. Micro-CT scans measured baseline volume of remaining filling material (in mm3). Samples were divided into two groups (n = 12) according to the supplementary cleaning approach: (PUI) or XP-endo Finisher R. Statistics compared baseline and final volume of filling material (within-group); and the percentage of filling material reduction (between-group). Mean baseline volumes, final volumes, and percentages of reduction (%) of filling material for XP-endo Finisher R and PUI were respectively: 0.060 mm3, 0.042 mm3, and 31.28%; and 0.064 mm3, 0.054 mm3, and 16.57%. Both tested protocols reduced the amount of filling material (p < 0.05). XP-endo Finisher R had higher percentage of reduction as compared to PUI (p < 0.05). XP-endo Finisher R and PUI used as supplementary cleaning protocols during re-treatment improved the removal of root filling material in curved canals; but XP-endo Finisher R was approximately twice more efficient. The complete filling material removal during re-treatment procedures is still a challenge. Supplementary cleaning protocols may help to remove the remaining material after the complete mechanical preparation of curved canals. XP-endo Finisher R was approximately twice more efficient than PUI.

3.
Microsc Res Tech ; 82(8): 1290-1296, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30993775

RESUMO

In this study, we evaluated the effectiveness of 1 and 5.25% NaOCl solutions, with or without surfactant, in disinfecting gutta-percha cones. Surface changes of the gutta-percha cones after disinfection were also assessed under scanning electron microscopy (SEM). One-hundred and eight gutta-percha cones previously contaminated with Enterococcus faecalis were left in contact for 30 s or 1 min with the following solutions (n = 12): 1% NaOCl; 1% NaOCl + 2% cetrimide; 5.25% NaOCl; 5.25% NaOCl + 2% cetrimide. Positive control group was composed by the remaining contaminated cones (n = 12), and the negative control group by noncontaminated cones (n = 12). The cones were kept in Eppendorf tubes containing Trypticase Soy Broth at 37°C for 24 hr, and then, the presence of turbidity was analyzed. Ten additional cones (n = 2) were observed under SEM to evaluate surface changes after 1 min of disinfection. The data analysis (Kruskal-Wallis test, α = 5%) demonstrated that regardless the presence of surfactant, the NaOCl solutions used were effective in the disinfection when cones were immersed for 1 min. However, at the 30-s period, only the 5.25% NaOCl solution was effective. SEM analysis demonstrated that NaOCl solutions promoted the formation of sodium chloride crystals on cones surface, less visible when the 1% NaOCl associated to surfactant was used. The addition of surfactant did not affect the disinfection capacity of NaOCl solutions. However, the surfactant has apparently inhibited the sodium chloride crystals deposition on the cones surface when associated to 1% NaOCl solution.


Assuntos
Desinfecção/métodos , Guta-Percha/análise , Hipoclorito de Sódio/farmacologia , Propriedades de Superfície , Tensoativos/farmacologia , Enterococcus faecalis/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Materiais Restauradores do Canal Radicular/análise , Cloreto de Sódio
4.
Clin Oral Investig ; 23(4): 1837-1844, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30215147

RESUMO

OBJECTIVES: This study aimed to compare WaveOne Gold with ProTaper and RaCe systems regarding remaining filling material, apical transportation (AT), and working time (WT) after (i) filling removal and (ii) shaping of curved canals. METHODS: Thirty mesiobuccal canals of maxillary molars were prepared and filled. After 30 days, they were randomly assigned into three groups (n = 10), according to the instruments used for filling removal and shaping, respectively: WOG-WaveOne Gold Primary and Medium; PTG-ProTaper Retreatment and ProTaper Next; RCG-D-RaCe and RaCe. Micro-CT analysis assessed the residual filling material and AT. WT was recorded. Data were statistically analyzed (α = .05). RESULTS: There was no significant difference between groups in the amount of filling material at any evaluated moment (P > .05). All groups presented low AT values. The WT was similar in all groups in filling removal (P > .05), and in shaping step WOG was faster than PTG and RCG (P < .05). CONCLUSIONS: Neither system could completely remove the filling material. The instruments evaluated were safe and the reciprocating system was faster than the rotary systems in shaping the canals. CLINICAL RELEVANCE: This study provided consistent information on filling material removal capacity of WaveOne Gold. Considering that all tested systems were safe, WaveOne Gold may be an alternative with cost-effectiveness and shorter learning curve for endodontic retreatment.


Assuntos
Obturação do Canal Radicular , Preparo de Canal Radicular/instrumentação , Microtomografia por Raio-X , Cavidade Pulpar , Humanos , Retratamento , Materiais Restauradores do Canal Radicular
5.
Microsc Res Tech ; 82(2): 128-133, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30582246

RESUMO

This study evaluated the influence of canal irrigation protocols with 5.25% calcium hypochlorite [Ca(OCl)2 ], 5.25% sodium hypochlorite (NaOCl) and 17% EDTA solution on the inorganic component of root canal dentin. Sixty roots were randomly divided into six groups (n = 10): Saline solution (SS) (control); Saline solution (SSE) +17% EDTA; CH - 5.25% Ca(OCl)2 ; CHE - 5.25% Ca(OCl)2 + 17% EDTA; SH - 5.25% NaOCl; SHE - 5.25% NaOCl +17% EDTA. After canal irrigation, the specimens were longitudinally split and analyzed by scanning electron microscopy (SEM). Dentinal tubules were observed in transverse (middle and apical thirds) direction. The images were classified in scores, according to smear layer removal and peritubular dentin alteration, and data were analyzed by Kruskal-Wallis's test, followed by Dunn's test (α = 0.05). In the middle third, all groups with EDTA presented better removal of the smear layer with higher peritubular dentin alteration (p < .05). In the apical third, this happened only in SHE (p < .05). Ca(OCl)2 and NaOCl exhibit similar performance to remove smear layer and alteration of the inorganic component in the middle third. In the apical third, NaOCl associated with EDTA showed better performance in smear layer removal.


Assuntos
Compostos de Cálcio/metabolismo , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Ácido Edético/metabolismo , Irrigantes do Canal Radicular/metabolismo , Camada de Esfregaço/ultraestrutura , Hipoclorito de Sódio/metabolismo , Dente Pré-Molar/efeitos dos fármacos , Dente Pré-Molar/ultraestrutura , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura
6.
Contemp Clin Dent ; 9(1): 26-30, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29599579

RESUMO

AIM: The aim of this study was to determine the bond strength (BS) of a self-adhesive resin cement to the contaminated root dentin. MATERIALS AND METHODS: The crown and apical third of twenty single-rooted teeth were removed. The root canals were flared and 1-mm-thick root sections were obtained. The sections were rinsed, dried, and sterilized. The control group (n=20) was composed of one section of each third, which remained immersed in sterile trypticase soy broth (TSB) for 2 months. The other sections comprised the experimental group (n = 40) and were immersed in a suspension of Enterococcus faecalis. The culture medium was changed at every 4 days for 2 months. The sections were rinsed with distilled water, dried, and the root canal space was filled with the self-adhesive resin cement RelyX™ U200. After 24 h, the push-out test was performed and the types of interface failure were observed on a stereo microscope. STATISTICAL ANALYSIS: Data were statistically analyzed by the nonparametric Mann-Whitney test (α=5%). RESULTS: A significant reduction was observed in the BS of resin cement to the contaminated dentin compared to the healthy dentin, for both thirds analyzed (P < 0.05). The BS was significantly greater at the cervical third compared to the middle third for specimens in the experimental group (P < 0.05). Adhesive and mixed failures were observed more frequently in specimens contaminated with E. faecalis. CONCLUSION: Bacterial contamination negatively infl uenced the BS of the self-adhesive resin cement to the root dentin, and there was a predominance of adhesive and mixed failures.

7.
Braz. dent. j ; 29(1): 54-59, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888720

RESUMO

Abstract The aim of this study was to assess the amount of apically extruded debris during filling removal with WaveOne Gold (WOG), ProTaper Universal Retreatment (PTR), D-RaCe Retreatment (DRR) or hand files (HF), to compare the working time during filling removal, and to describe failures of NiTi instruments. Forty mesiobuccal roots of maxillary first molars were prepared with WOG Primary, obturated and divided into 4 groups (n=10), according to the instruments used: WOG, PTR, DRR or HF. Distilled water was used as irrigant and the extruded debris were collected in Eppendorf tubes and dried. The amount of extruded debris was determined by subtracting the final from the initial weight. The time of filling removal for each canal was recorded and the instruments used were analyzed pre and post-operatively by SEM. Kruskal-Wallis and Dunn's test analyzed extruded debris data and ANOVA, followed by Tukey's test, compared the working time data (a=0.05). Instrument deformation and fracture were described. WOG produced significantly less debris compared with HF and DRR (p<0.05), and similar to PTR (p>0.05). HF, PTR and DRR showed no significant difference (p>0.05). Working time in HF group was significantly higher than others (p<0.05). SEM analyses showed, from the 18 instruments evaluated, 3 fractures and 10 deformations. All instruments tested caused debris extrusion. WOG was associated with less extrusion than DRR and HF. Filling removal with HF was slower than with the other instruments. All NiTi systems presented fracture and deformation.


Resumo O objetivo deste estudo foi avaliar a extrusão apical de debris durante a desobturação com WaveOne Gold (WOG), ProTaper Universal Retratamento (PTR), D-RaCe (DRR) ou limas manuais (HF), comparar o tempo de trabalho durante a desobturação, e descrever as falhas dos instrumentos de NiTi. Quarenta canais de raízes mésio-vestibulares de primeiros molars superiores foram preparados com WOG Primary, obturados e divididos em 4 grupos (n = 10), de acordo com os instrumentos a serem utilizados: WOG, PTR, DRR ou HF. Água destilada foi utilizada como irrigante, e os debris extruídos foram coletados em tubos Eppendorf e secos. A quantidade de debris extruídos foi determinada subtraindo-se o peso inicial do peso final. O tempo de cada desobturação foi anotado e os instrumentos utilizados foram analisados no pré e pós-operatório em MEV. Os testes Kruskal-Wallis e Dunn foram utilizados para analisar os dados da extrusão de debris, e os testes ANOVA e Tukey para comparar os dados do tempo de trabalho (a=0.05). As deformações e fraturas dos instrumentos foram descritas. O grupo WOG produziu significativamente menos debris quando comparado aos grupos HF e DRR (p<0.05), e foi similar ao grupo PTR (p>0.05). Os grupos HF, PTR e DRR não apresentaram diferença estatisticamente significante (p>0.05). O tempo de trabalho no grupo HF foi significativamente maior do que nos outros grupos (p<0.05). A análise em MEV mostrou que, dos 18 instrumentos avaliados, 3 fraturaram e em 10 foi observado deformação. Todos os sistemas testados causaram extrusão apical de debris. WOG foi associado com menor extrusão do que DRR e HF. A desobturação com HF foi mais lenta do que com os demais instrumentos. Todos os sistemas de NITI apresentaram fratura e deformação.


Assuntos
Humanos , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Ápice Dentário , Irrigação Terapêutica
8.
Gen Dent ; 66(1): e1-e4, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29303756

RESUMO

The aim of this case report is to describe the treatment of an 11-year-old boy who was referred to an endodontist for evaluation of external inflammatory root resorption in the distal apical third of the permanent maxillary left lateral incisor, caused by deviation in the eruption path of the permanent maxillary left canine. The results of the pulpal sensitivity test of the permanent maxillary left lateral incisor were inconclusive and similar to those for the homologous tooth, so the endodontist opted for a clinical and radiographic follow-up. The patient was referred to an orthodontist, who placed a fixed Haas-type palatal expander. After the eruption of all permanent teeth, the orthodontist placed a fixed orthodontic appliance. After approximately 3 years of monitoring, bone repair with dental remodeling was observed, and the results of a pulpal sensitivity test were positive. This case demonstrates that proper monitoring is critical in establishing the diagnosis and treatment plan and ultimately to the success of clinical management.


Assuntos
Dente Canino , Incisivo , Reabsorção da Raiz/terapia , Erupção Ectópica de Dente/terapia , Técnicas de Movimentação Dentária/métodos , Criança , Dente Canino/diagnóstico por imagem , Humanos , Incisivo/diagnóstico por imagem , Masculino , Aparelhos Ortodônticos , Radiografia Dentária , Radiografia Panorâmica , Reabsorção da Raiz/diagnóstico por imagem , Reabsorção da Raiz/etiologia , Erupção Ectópica de Dente/complicações , Erupção Ectópica de Dente/diagnóstico por imagem , Técnicas de Movimentação Dentária/instrumentação
9.
Braz Dent J ; 29(1): 54-59, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29267525

RESUMO

The aim of this study was to assess the amount of apically extruded debris during filling removal with WaveOne Gold (WOG), ProTaper Universal Retreatment (PTR), D-RaCe Retreatment (DRR) or hand files (HF), to compare the working time during filling removal, and to describe failures of NiTi instruments. Forty mesiobuccal roots of maxillary first molars were prepared with WOG Primary, obturated and divided into 4 groups (n=10), according to the instruments used: WOG, PTR, DRR or HF. Distilled water was used as irrigant and the extruded debris were collected in Eppendorf tubes and dried. The amount of extruded debris was determined by subtracting the final from the initial weight. The time of filling removal for each canal was recorded and the instruments used were analyzed pre and post-operatively by SEM. Kruskal-Wallis and Dunn's test analyzed extruded debris data and ANOVA, followed by Tukey's test, compared the working time data (a=0.05). Instrument deformation and fracture were described. WOG produced significantly less debris compared with HF and DRR (p<0.05), and similar to PTR (p>0.05). HF, PTR and DRR showed no significant difference (p>0.05). Working time in HF group was significantly higher than others (p<0.05). SEM analyses showed, from the 18 instruments evaluated, 3 fractures and 10 deformations. All instruments tested caused debris extrusion. WOG was associated with less extrusion than DRR and HF. Filling removal with HF was slower than with the other instruments. All NiTi systems presented fracture and deformation.


Assuntos
Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Ápice Dentário , Humanos , Irrigação Terapêutica
10.
Braz Dent J ; 28(5): 592-596, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29215684

RESUMO

The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Assuntos
Guta-Percha , Teste de Materiais
11.
Braz. dent. j ; 28(5): 592-596, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888696

RESUMO

Abstract The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Resumo O objetivo deste estudo foi avaliar a radipacidade de diferentes pontas de guta-percha (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® e Odous®) em amostras de 1 mm de espessura, conforme estabelecido pela especificação #57 da ANSI/ADA e pela ISO 6876/2001, em comparação com amostras de menor espessura. Doze amostras de cada material, quatro para cada espessura (0,3, 0,6 e 1 mm; 8 mm de diâmetro), foram confeccionadas por meio de laminação e compressão entre duas lâminas de vidro polidas, até a espessura desejada. Radiografias digitais foram obtidas juntamente com uma escala de alumínio graduada, com espessuras variando de 1 a 10 mm. O aparelho de raios X foi ajustado para 70 kVp, 10 mA, 0,4s de tempo de exposição, com distância focal de 36 cm. Um observador calibrado quantificou a média dos valores de pixel no programa Adobe Photoshop®. Os dados foram analisados utilizando os testes ANOVA e Tukey, com nível de significância de 5%. Nas espessuras de 0,6 e 1 mm, todos os materiais testados apresentaram radiopacidade maior do que 3 mm de alumínio (valor de referência). Na espessura de 0,3 mm, Odous e Tanari apresentaram radiopacidade significativamente menor que a referência, e as outras marcas mostraram radiopacidade semelhante à referência. Conclui-se que os materiais apresentaram diferentes radiopacidades e todos mostraram valores acima do mínimo recomendado pela especificação #57 da ANSI/ADA, sendo Odous e Tanari menos radiopacos do que o valor de referência nas amostras mais finas (0.3 mm).


Assuntos
Guta-Percha , Teste de Materiais
12.
Braz Dent J ; 26(5): 525-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26647940

RESUMO

The aim of this study was to evaluate the mesiobuccal root of maxillary first molars, according to the root canal configuration, prevalence and location of isthmuses at 3 and 6 mm from the apex, comparing cone-beam computed tomography (CBCT) analysis and cross sectioning of roots by thirds. Images of the mesiobuccal root of 100 maxillary first molars were acquired by CBCT and then roots were cross-sectioned into two parts, starting at 3 mm from the apex. Data were recorded and analyzed according to Weine's classification for root canal configuration, and Hsu and Kim's classification for isthmuses. In the analysis of CBCT images, 8 root canals were classified as type I, 57 as type II, 35 as type III. In the cross-sectioning technique, 19 root canals were classified as type I, 60 as type II, 20 as type III and 1 as type IV. The classification of isthmuses was predominantly type I in both CBCT and cross-sectioning evaluations for sections at 3 mm from the apex, while for sections at 6 mm from the apex, the classification of isthmuses was predominantly types V and II in CBCT and cross-sectioning evaluations, respectively. The cross-sectioning technique showed better results in detection of the internal morphology of root canals than CBCT scanning.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Maxila/anatomia & histologia , Dente Molar/anatomia & histologia , Humanos
13.
Braz. dent. j ; 26(5): 525-529, Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767628

RESUMO

Abstract: The aim of this study was to evaluate the mesiobuccal root of maxillary first molars, according to the root canal configuration, prevalence and location of isthmuses at 3 and 6 mm from the apex, comparing cone-beam computed tomography (CBCT) analysis and cross sectioning of roots by thirds. Images of the mesiobuccal root of 100 maxillary first molars were acquired by CBCT and then roots were cross-sectioned into two parts, starting at 3 mm from the apex. Data were recorded and analyzed according to Weine's classification for root canal configuration, and Hsu and Kim's classification for isthmuses. In the analysis of CBCT images, 8 root canals were classified as type I, 57 as type II, 35 as type III. In the cross-sectioning technique, 19 root canals were classified as type I, 60 as type II, 20 as type III and 1 as type IV. The classification of isthmuses was predominantly type I in both CBCT and cross-sectioning evaluations for sections at 3 mm from the apex, while for sections at 6 mm from the apex, the classification of isthmuses was predominantly types V and II in CBCT and cross-sectioning evaluations, respectively. The cross-sectioning technique showed better results in detection of the internal morphology of root canals than CBCT scanning.


Resumo: O objetivo do presente estudo foi avaliar a raiz mésio-vestibular de primeiros molares superiores, de acordo com a configuração do canal radicular e com a prevalência e localização de istmos a 3 e a 6 mm do ápice, comparando a análise realizada em tomografia computadorizada de feixe cônico (TCFC) com a técnica de seccionamento transversal por terços. Foram obtidas imagens tomográficas das raízes mésio-vestibulares de 100 primeiros molares superiores, e em seguida, as raízes foram seccionadas em dois segmentos, iniciando nos 3 mm a partir do ápice. Os dados foram analisados de acordo com a classificação de Weine para configuração de canais radiculares, e de acordo com a classificação de Hsu e Kim para avaliação dos istmos. Na análise das imagens das TCFCs, 8 canais radiculares foram classificados como tipo I, 57 como tipo II, e 35 como tipo III. Na técnica de seccionamento transversal, 19 canais radiculares foram classificados como tipo I, 60 como tipo II, 20 como tipo III, e 1 como tipo IV. Na avaliação dos istmos, houve predominância do tipo I tanto na TCFC quanto na técnica de seccionamento transversal a 3 mm do ápice. Entretanto, a 6 mm do ápice, a classificação dos istmos foi predominantemente tipo V e II, na avaliação em TCFC e na técnica de seccionamento transversal, respectivamente. A técnica de seccionamento transversal demonstrou melhores resultados na detecção da morfologia interna dos canais radiculares avaliados do que a TCFC.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Maxila/anatomia & histologia , Dente Molar/anatomia & histologia
14.
J Endod ; 41(11): 1923-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26410152

RESUMO

Florid cemento-osseous dysplasia (FCOD) belongs to the group of fibro-osseous lesions in which normal bone is replaced by fibrous connective tissue and calcified cementum tissue of the avascular type. Among the various types of fibro-osseous lesions, FCOD is one of the most commonly encountered diseases in clinical practice and may involve 3 or 4 of the quadrants. FCOD is located in the periapical regions of teeth, and the lesions are predominantly radiolucent (osteolytic phase), become mixed over time (cementoblast phase), and ultimately become radiopaque (osteogenic phase) with a thin radiolucent peripheral halo. The characteristics of FCOD in the initial stages are similar to those of periapical lesions of inflammatory origin, which may lead to misdiagnosis. A 38-year-old woman sought dental care because of complaints of pain on the right side of her face. A clinical examination revealed no marked alterations; a panoramic radiograph was therefore requested and revealed the presence of radiolucent lesions associated with the periapical regions of some of the lower teeth. Thus, the professional referred the patient for endodontic treatment of the associated teeth with the justification that the lesions were of endodontic origin. However, the endodontist found that the teeth responded positively to a sensitivity test. The initial diagnosis could have resulted in unnecessary root canal treatment, but after careful clinical, radiographic, and tomographic assessments by different professionals, FCOD was diagnosed, conservatively treated, and regularly monitored. It is important that dentists have a basic knowledge of the various injuries that affect the jaw bones to prevent errors in diagnosis and treatment and to promote oral health.


Assuntos
Erros de Diagnóstico , Displasia Fibrosa Óssea/diagnóstico , Displasia Fibrosa Óssea/patologia , Osteomielite/diagnóstico , Osteomielite/patologia , Periodontite Periapical/diagnóstico , Periodontite Periapical/patologia , Adulto , Diagnóstico Diferencial , Feminino , Displasia Fibrosa Óssea/diagnóstico por imagem , Humanos , Osteomielite/diagnóstico por imagem , Periodontite Periapical/diagnóstico por imagem , Radiografia Panorâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA