Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Hellenic J Cardiol ; 75: 21-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37127207

RESUMO

BACKGROUND: The Cocoon patent foramen ovale (PFO) occluder is a new device especially designed for transcatheter closure of PFO. This occluder has some distinctive structural modifications aimed at reducing the risk of major complications of transcatheter PFO closure. In this report we present our initial experience to evaluate the efficacy and safety of the Cocoon PFO occluder in 253 patients who underwent transcatheter PFO closure. METHODS: The study cohort included 253 patients (median age 45 years) with embolic stroke of undetermined source who underwent attempted transcatheter closure of PFO for secondary prevention of paradoxical embolism. Patients were enrolled retrospectively from five sites in Greece and one in Romania between December 2016 and January 2021, and the median follow-up period was 28 months (range 12-48 months). Clinical and laboratory data from each participating center were sent to an electronic registry for evaluation and statistical analysis. RESULTS: The Cocoon PFO occluder was permanently implanted in all patients. At 6 months, complete occlusion of PFO was observed in 251/253 (99.2%) patients. Three (1.2%) patients had a trivial residual shunt. Thrombus formation on the device, which was successfully treated with recombinant tissue plasminogen activator infusion, was observed in one (0.4%) patient. No other complications occurred. During a median follow-up period of 28 months, 3 (1.2%) patients, aged 64-67 years, developed new onset paroxysmal atrial fibrillation. No neurologic events, cardiac erosions, allergic reactions to nickel, or thrombus formation occurred. CONCLUSION: The Cocoon PFO occluder is an effective and safe device that adds to our armamentarium for transcatheter closure of PFO.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Trombose , Humanos , Pessoa de Meia-Idade , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual , Próteses e Implantes , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos
2.
Hellenic J Cardiol ; 62(3): 206-211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33484876

RESUMO

BACKGROUND: The Cocoon septal occluder (CSO) is a new generation double disk occluder device for catheter closure of the secundum atrial septal defect (ASD). Initial clinical evaluations with the use of this device have shown quite satisfactory results but large follow-up studies are missing. In this international multicenter study, we present procedural and follow-up data from 4008 patients with secundum ASD who underwent catheter closure with the use of CSO. METHODS: The study cohort consisted of 1853 pediatric and 2155 adult patients with secundum ASD treated with the CSO. Patients were enrolled retrospectively from 11 international centers and were followed for a mean period of 43 months (range 12-84 months), postprocedural. Clinical, electrocardiographic, echocardiographic, procedural, and follow-up data were collected from each collaborating hospital. RESULTS: The CSO was permanently implanted in 3983 patients (99.4%). Echocardiographic evaluation at one month follow-up revealed complete closure in 99.6% of those patients who had a device implanted. Thrombus formation in one adult patient was the only major device related to procedural complication. During the follow-up period, no patient developed cardiac erosions, allergic reactions to nickel, or other major complications. CONCLUSIONS: Implantation of CSO provided satisfactory procedural and follow-up results with high success and no device-related cardiac erosions and nickel allergy.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Ecocardiografia Transesofagiana , Seguimentos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Estudos Retrospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
3.
Am J Cardiol ; 118(10): 1558-1562, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27670796

RESUMO

The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children.


Assuntos
Angiografia/métodos , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo Venoso Central/métodos , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia Doppler em Cores/métodos , Cirurgia Assistida por Computador/métodos , Cateteres Cardíacos , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Lactente , Masculino , Resultado do Tratamento
4.
Int J Cardiol ; 177(2): 418-22, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25305675

RESUMO

Despite its simplicity, device closure of atrial septal defects is still associated with rare but potentially lethal complications. In this prospective non-randomized multicenter study we investigated the safety and efficacy of the Cocoon septal occluder (CSO) for closure of atrial septal defects (ASDs) in 92 patients. Median age of the patients was 10.5 years (range 3-61 years) and median weight was 25 kg (range 13-65 kg). The device is an improved new generation double disc design made of Nitinol wire mesh that is coated with platinum using NanoFusion technology. The discs are connected by a waist with diameter ranging from 6mm to 40 mm with 2mm increments. All patients completed a 3-month follow-up. Mean ASD diameter was 21 ± 7 mm (range 10-35 mm), while the mean device diameter was 24 ± 8 mm (range 14-40 mm). The CSO was permanently implanted in all 92 patients. Complete echocardiographic closure of the defect immediately after the procedure or at the one month follow-up, was observed in all 92 patients (100%). No device-related complications were observed during the procedure or at short-term follow-up (range 3-12 months). Our preliminary results indicate that CSO is a promising device for transcatheter closure of ASDs. Further studies are required to document its efficacy, safety and long-term results in a larger patient population.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/epidemiologia , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal/estatística & dados numéricos , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA