Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Ultrasound ; 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36790657

RESUMO

OBJECTIVE: To validate shear wave elastography (SWE) stiffness measurements for the ulnar collateral ligament (UCL) of the elbow compared to mechanical measurements. MATERIALS AND METHODS: Eleven fresh frozen human cadaveric upper extremities were evaluated by a musculoskeletal-specialized radiologist to provide SWE measurements used to calculate stiffness at 4 points along the anterior band of the UCL at various load states and flexion angles. Specimens were then dissected and optical markers were placed on the UCL to track displacement during applied force by a load frame, thereby providing measurements to calculate the mechanical stiffness. These two stiffness values were compared by ANOVA for all load states and flexion angles. RESULTS: Measurements of stiffness by SWE for the UCL were three orders of magnitude smaller than the true mechanical testing stiffness and no correlations between SWE and mechanical measurements of stiffness were found at 30, 60 or 90 degrees of elbow flexion (R2 = 0.004, p = 0.85; R2 = 0.001, p = 0.92; R2 = 0.15, p = 0.24 respectively). SWE stiffness was greatest near the insertion of the ligament and lowest in the mid-substance of the ligament (p = 0.0002). CONCLUSIONS: SWE stiffness did not correlate with mechanical measurements. Clinical utility of musculoskeletal SWE may be better defined when biomechanical properties or clinical outcomes can be correlated with SWE measurements. The ultimate clinical utility of SWE in musculoskeletal tissues may be qualitative, as demonstrated by differences throughout the length of the UCL in this study.

2.
J Knee Surg ; 36(3): 298-304, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34327694

RESUMO

Anterior cruciate ligament (ACL) graft failure rate has been reported to be greater than 5% at 5 years. Our study evaluated ACL excursion with anatomic and nonanatomic femoral and tibial tunnels to determine optimal flexion angle to tension the ACL to minimize excursion. Ten cadaveric knee specimens were used. The ACL was sectioned and the femoral and tibial attachments were marked. A 1/16-inch drill created a tunnel in the center of the ACL footprint on the tibia and femur and additional tunnels were made 5 mm from this. A suture was passed through each tunnel combination and attached to a string potentiometer. The knee was ranged from full extension to 120 degrees of flexion for 10 cycles while mounted in a custom fixture. The change in length (excursion) of the suture during movement was recorded for each combination of femoral and tibial tunnels. Anatomic reconstruction of the ACL with tunnel placement in the center of the femoral and tibial footprint did not result in an isometric graft, with excursion of the ACL during knee motion of 7.46 mm (standard deviation [SD]: 2.7mm), greatest at 2.84 degrees of flexion (SD: 4.22). The tunnel combination that resulted in the least excursion was a femoral footprint 5 mm anterior to the femoral and 5 mm posterior to the tibial footprint (4. 2mm, SD: 1.37 mm). The tunnel combination that resulted in the most excursion utilized femoral footprint 5 mm proximal to the femoral and 5 mm posterior to the tibial footprint (9.81 mm, SD: 2.68 mm). Anatomic ACL reconstruction results in significant excursion of the ACL throughout motion. If not tensioned properly, the ACL can stretch during range of motion, potentially leading to rerupture. To prevent stretching of the graft, the current biomechanical study recommends tensioning an anatomic ACL reconstruction at its point of maximal excursion, or between 0 and 5 degrees of flexion. The level of evidence is IV.


Assuntos
Ligamento Cruzado Anterior , Tíbia , Humanos , Ligamento Cruzado Anterior/cirurgia , Tíbia/cirurgia , Cadáver , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos
3.
J Biomech ; 137: 111094, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35489236

RESUMO

Failure by fatigue is one mechanism by which ligaments can rupture, with the accumulation of damage gradually degrading the ligament strength. Baseball pitchers who perform repeated high-level throwing continuously subject the medial ligament complex of the elbow to extreme levels of loading, which can lead to fatigue and eventual rupture. This study sought to investigate this behavior and quantify the fatigue properties of the anterior bundle of the medial collateral ligament (AMCL) with respect to valgus elbow torque. Eleven pairs of cadaveric elbow specimens were used for this study. One side of each pair was tested in vertical elongation at four flexion angles and then tested to failure at 90° of flexion. The contralateral specimens were tested in valgus fatigue at 90° of flexion using a specialized apparatus with application of known moments based on the elongation failure load. The average tensile failure load for the AMCL was 595.3 ± 201.9 N. During cycling, the average increase in the maximum valgus rotation angle was 4.77° ± 2.82°. The average maximum stretch of the AMCL middle band increased from 1.066 ± 0.017 to 1.076 ± 0.018 near the time of fatigue failure. The average cycles to failure for specimens tested at 90% and 80% of the estimated failure torque were 3211 ± 4721.33 and 25063 ± 30487.58, respectively. The nonlinear non-dimensional fatigue life and damage accretion results work in conjunction to predict the fatigue properties for a valgus elbow motion of arbitrary torque magnitude at 90° of elbow flexion.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Fenômenos Biomecânicos , Cadáver , Cotovelo , Humanos , Rotação , Ruptura
4.
J Am Acad Orthop Surg ; 28(20): e888-e899, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32701688

RESUMO

Bone marrow edema (BME) is a descriptive term used to describe high-signal intensity changes detected on magnetic resonance fluid-sensitive sequences that could be attributed to a number of underlying pathologies. Regardless of the cause, physiologic remodeling of the subchondral bone can be limited because of ongoing joint forces, increased focalization of stress, and reduced healing capacity of the subchondral bone. BME is a known prognostic factor associated with pain, dysfunction, and progressive cartilage damage. This review summarizes the current known causes of BMEs, theories related to histopathological changes, and current treatment options including novel biologic surgical options.


Assuntos
Doenças da Medula Óssea/etiologia , Doenças da Medula Óssea/terapia , Fosfatos de Cálcio/economia , Edema/etiologia , Edema/terapia , Adulto , Doenças da Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/patologia , Substitutos Ósseos/administração & dosagem , Fosfatos de Cálcio/administração & dosagem , Cartilagem Articular/patologia , Tratamento Conservador , Imagem de Difusão por Ressonância Magnética , Edema/diagnóstico por imagem , Edema/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos , Dor/etiologia , Prognóstico
5.
J Shoulder Elbow Surg ; 29(6): 1230-1235, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32197808

RESUMO

HYPOTHESIS AND BACKGROUND: Injuries to the elbow medial ulnar collateral ligament (mUCL) pose a diagnostic challenge, with the moving valgus stress test (MVST) currently accepted as the gold-standard clinical test. This study sought to biomechanically evaluate the change in length of the ulnar collateral ligament (UCL) during flexion-extension using a null hypothesis that the mUCL will not experience a greater change in length with movement than with static loading. METHODS: Seven fresh-frozen human cadaveric elbows were tested with static and dynamic valgus stress. We measured (1) ligament length with a multi-camera optical system, (2) elbow flexion with an incremental encoder, and (3) valgus deviation with an electronic inclinometer. With a force applied to the wrist to simulate a clinical stress examination, the elbow was flexed and extended in a physiological elbow simulator to mimic the flexion and extension of the MVST. RESULTS: The simulated MVST produced more elongation of the UCL compared with static stress testing (P < .001). Ninety degrees of flexion produced the highest mean change, and the anterior and posterior bands demonstrated different length change characteristics. Comparison of dynamic flexion and extension showed a statistically significant difference in change in length: The mUCL reached the greatest change during extension, with the greatest changes during extension near 90° of flexion. DISCUSSION AND CONCLUSION: The MVST produces significantly more elongation of the mUCL than either a static test or a moving test in flexion. This study provides biomechanical evidence of the validity of the MVST as a superior examination technique for injuries to the UCL.


Assuntos
Ligamento Colateral Ulnar/fisiopatologia , Articulação do Cotovelo/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Adulto , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Suporte de Carga/fisiologia
6.
J Orthop Res ; 37(9): 2027-2034, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31081556

RESUMO

The anterior bundle of the medial collateral ligament (AMCL) resists the loads that arise at the elbow during overhand throwing and has commonly been divided into posterior and anterior bands. While these anterior and posterior bands have been thought to bear the load at different flexion angles, any transition of the load distribution between the two bands is poorly understood and has not considered laxity (slack). This study considers the AMCL as three bands and quantifies the mechanical response to vertical distraction, simulating valgus-load joint opening, through the sequential superposition of the band responses after the elimination of inherent laxity. Eight cadaveric elbow specimens were used for the study. The intact AMCL of each specimen was tested under vertical distraction in a specialized load frame at four elbow flexion angles and then subsequently retested after two longitudinal transections. The greatest laxity at full extension and full flexion belonged to the posterior (1.9 mm) and anterior (2.4 mm) band, respectively. At the lesser and higher flexion angles, the greatest structural stiffness belonged to the anterior and middle band. The overall AMCL was the most structurally stiff at 60°, with approximately 150 N of force required for 2% elongation. This study shows that the different bands of the AMCL may have different load bearing properties at different flexion angles, causing each band to support different proportions of an imposed load. The presence of the laxity may impose a load-bearing delay, causing load-bearing in each band to begin asynchronously. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2027-2034, 2019.


Assuntos
Ligamentos Colaterais/fisiologia , Articulação do Cotovelo/fisiologia , Adulto , Fenômenos Biomecânicos , Humanos , Masculino , Pessoa de Meia-Idade , Suporte de Carga
7.
JBJS Rev ; 4(9)2016 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-27760074

RESUMO

Major anatomic risk factors for recurrent patellar instability include trochlear dysplasia, patella alta, a lateralized tibial tuberosity, and medial patellofemoral ligament insufficiency. Acute first-time patellar dislocation may be treated nonoperatively in the absence of osteochondral injury. Recurrent patellar instability often requires medial patellofemoral ligament reconstruction, with osseous procedures reserved for patients with substantial underlying anatomic abnormalities. Surgical treatment of patellar instability is complex and should be individualized to address the needs of each patient.


Assuntos
Algoritmos , Instabilidade Articular , Luxação Patelar , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/terapia , Ligamentos Articulares , Patela , Luxação Patelar/diagnóstico , Luxação Patelar/terapia
8.
Springerplus ; 4: 460, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26339561

RESUMO

BACKGROUND: Novel microbial detection technologies have revealed that chronic bacterial biofilms, which are recalcitrant to antibiotic treatment, are common in failed orthopedic procedures. QUESTIONS: Are bacteria present on failed anterior cruciate ligament (ACL) reconstructions? Is there a difference in the presence or nature of bacteria in failed ACL reconstructions relative to a control set of healthy ACL's? METHODS: We used a case-control study design, where we analyzed the bacterial composition of 10 failed ACL reconstructions and compared it to 10 native ACL's harvested during total knee arthroplasty. The IBIS Universal Biosensor was used to determine the nature of bacteria on ACL specimens, and fluorescent in situ hybridization (FISH) was used to visualize bacteria in a subset of cases. RESULTS: Bacteria are present in failed ACL reconstructions. Bacteria are present in ACL's harvested during total knee arthroplasty, but the nature of the species differs significantly between experimental and control sets. Twelve genera were detected in the experimental set (in both allografts and autografts), and in four samples multiple species were detected. In contrast, the control group was characterized by presence of Propionibacterium acnes. CONCLUSIONS: We demonstrate the presence of bacteria on failed ACLs surgeries, and open the door to investigate whether and how bacteria and the associated immune responses could possibly contribute to graft failure. CLINICAL RELEVANCE: If microbial pathogens can be linked to failed grafts, it could provide: (1) markers for early diagnosis of abnormal healing in ACL surgeries, and (2) targets for early treatment to prevent additional reconstruction surgeries.

10.
FEMS Immunol Med Microbiol ; 62(1): 66-74, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21332826

RESUMO

Bacterial biofilms have been observed in many prosthesis-related infections, and this mode of growth renders the infection both difficult to treat and especially difficult to detect and diagnose using standard culture methods. We (1) tested a novel coupled PCR-mass spectrometric (PCR-MS) assay (the Ibis T5000) on an ankle arthroplasty that was culture negative on preoperative aspiration and then (2) confirmed that the Ibis assay had in fact detected a viable multispecies biofilm by further micrographic and molecular examinations, including confocal microscopy using Live/Dead stain, bacterial FISH, and reverse-transcriptase-PCR (RT-PCR) assay for bacterial mRNA. The Ibis technology detected Staphylococcus aureus, Staphylococcus epidermidis, and the methicillin resistance gene mecA in soft tissues associated with the explanted hardware. Viable S. aureus were confirmed using RT-PCR, and viable cocci in the biofilm configuration were detected microscopically on both tissue and hardware. Species-specific bacterial FISH confirmed a polymicrobial biofilm containing S. aureus. A novel culture method recovered S. aureus and S. epidermidis (both methicillin resistant) from the tibial metal component. These observations suggest that molecular methods, particularly the new Ibis methodology, may be a useful adjunct to routine cultures in the detection of biofilm bacteria in prosthetic joint infection.


Assuntos
Artroplastia de Substituição do Tornozelo/efeitos adversos , Biofilmes/classificação , Staphylococcus aureus Resistente à Meticilina/classificação , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/classificação , Idoso , Articulação do Tornozelo/microbiologia , Técnicas de Tipagem Bacteriana , Biofilmes/crescimento & desenvolvimento , DNA Bacteriano/análise , DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Feminino , Humanos , Hibridização in Situ Fluorescente , Espectrometria de Massas/métodos , Resistência a Meticilina , Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/crescimento & desenvolvimento , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Microscopia Confocal , Reação em Cadeia da Polimerase/métodos , Especificidade da Espécie , Staphylococcus aureus/genética , Staphylococcus aureus/crescimento & desenvolvimento , Staphylococcus aureus/isolamento & purificação
11.
Arthroscopy ; 26(8): 1105-10, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20678709

RESUMO

PURPOSE: The purpose of this study was to evaluate the effect that interference screw diameter has on fixation strength of a soft-tissue anterior cruciate ligament (ACL) graft. METHODS: We prepared 32 fresh-frozen bovine tibiae with 9-mm ACL tibial tunnels. Accompanying 9-mm soft-tissue bovine Achilles grafts were also prepared. Bioabsorbable interference screws of increasing diameters were used for tibial fixation. There were 4 groups, consisting of 8-, 9-, 10-, and 11-mm screws for fixation of the 9-mm graft in the 9-mm tunnel. Tensile testing and cyclic loading from 50 to 250 N at 2 Hz for a total of 1,500 cycles were performed with a hydraulic biaxial materials testing machine. Graft slippage was measured with a video analysis technique with photo-reflective markers. At the end of cyclic testing, the grafts were loaded to failure, and the ultimate strength was recorded. RESULTS: All grafts failed at the tendon-bone-screw interface. The ultimate strength (+/- SD) was greatest for the 11-mm screw (624 +/- 133 N), with slightly decreased strength for the 10-mm (601 +/- 54 N), 9-mm (576 +/- 85 N), and 8-mm (532 +/- 185 N) screws. Graft slippage (+/- SD) was least for the 9-mm screw (2.65 +/- 2.38 mm). There were no statistically significant differences in ultimate strength and graft slippage between screws (P = .45 and P = .34, respectively). CONCLUSIONS: All interference screws tested provided adequate fixation strength. The results of this study show no statistical significance for ultimate strength or graft slippage with variable screw diameter. CLINICAL RELEVANCE: Aperture fixation with the interference screw technique provides adequate stability for soft-tissue grafts in ACL reconstruction. Although no statistical significance was found, there was a trend toward less graft-site motion when we used a screw diameter equal to tunnel size.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Parafusos Ósseos , Procedimentos de Cirurgia Plástica , Tendões/transplante , Implantes Absorvíveis , Animais , Fenômenos Biomecânicos , Bovinos , Técnicas In Vitro , Tíbia/cirurgia
12.
Am J Sports Med ; 38(10): 2077-84, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20595547

RESUMO

BACKGROUND: High tibial osteotomy is a valuable option for patients with varus gonarthrosis. To avoid difficulties with closing-wedge osteotomies, medial opening-wedge high tibial osteotomies have been advocated. HYPOTHESIS: Opening-wedge high tibial osteotomy is a good option in highly active patients with varus gonarthrosis who would like to delay or prevent progression to total knee arthroplasty without activity restrictions. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Twenty consecutive patients with varus gonarthrosis were treated with a medial opening-wedge high tibial osteotomy using the Puddu plate and allograft bone graft for a prospective study (14 men and 6 women; average age, 49.4 years [range, 36-67 years]). Gait analysis was performed preoperatively and at 6 months postoperatively. Preoperative radiographs, subjective ratings, and knee scores (Lysholm and Hospital for Special Surgery [HSS] scores) were obtained. At 2 years postoperatively and at the latest follow-up visit (average, 8.3 years), the subjective ratings and knee scores were repeated. RESULTS: Gait analysis revealed an abnormal weightbearing pattern preoperatively with the vertical ground-reaction force. The postoperative vertical ground-reaction force revealed a normal double peak pattern. The preoperative adduction moment was 29% greater than the 6-month postoperative adduction moment. The preoperative varus averaged 3.6° and was corrected to an average of 7.5° of valgus postoperatively. All patients subjectively rated their preoperative knee as poor. At 2 years postoperatively, most patients (14) rated their knee as good, with 5 excellent and only 1 fair rating. The average preoperative Lysholm and HSS knee scores were 54.2 and 75.9, respectively, compared with the 2-year postoperative averages of 89.1 and 92.7, respectively. At 8 years postoperatively, there was 70% survivorship with 42% of patients rating their knees as good or excellent. Five patients (25%) had undergone total knee arthroplasty. Lysholm and HSS knee scores were 83.0 and 86.8, respectively, for the surviving knees at 8 years postoperatively. CONCLUSION: Medial opening-wedge high tibial osteotomy produces good results in the midterm. After the osteotomy, a more normal appearing weightbearing pattern with double peaks was seen. The adduction moment significantly decreased, resulting in less contact pressure through the medial degenerative compartment of the knee. The authors recommend medial opening-wedge high tibial osteotomy for young patients with varus alignment and medial compartment arthritis to allow this patient population to remain highly active and delay progression to total knee arthroplasty without activity restrictions.


Assuntos
Osteotomia/métodos , Tíbia/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Marcha/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/métodos , Período Pós-Operatório , Radiografia , Tíbia/diagnóstico por imagem
13.
Orthopedics ; 31(2): 177, 2008 02.
Artigo em Inglês | MEDLINE | ID: mdl-19292191

RESUMO

Osteonecrosis of the femoral head is a major problem, especially in younger patients. Most of them need a total hip replacement. This article presents a case of a successful autologous osteochondral transfer.


Assuntos
Cistos Ósseos/complicações , Cistos Ósseos/cirurgia , Cartilagem Articular/transplante , Necrose da Cabeça do Fêmur/complicações , Necrose da Cabeça do Fêmur/cirurgia , Adulto , Humanos , Masculino , Transplante Autólogo , Resultado do Tratamento
14.
J Bone Joint Surg Am ; 89 Suppl 2 Pt.1: 103-10, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17332129

RESUMO

BACKGROUND: Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. METHODS: We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. RESULTS: Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). CONCLUSIONS: We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.


Assuntos
Artrodese/métodos , Artroplastia do Joelho , Articulação do Joelho/cirurgia , Infecção da Ferida Cirúrgica/cirurgia , Idoso , Amputação Cirúrgica , Antibacterianos/administração & dosagem , Pinos Ortopédicos , Desbridamento , Remoção de Dispositivo , Feminino , Seguimentos , Humanos , Masculino , Reoperação , Resultado do Tratamento
15.
J Bone Joint Surg Am ; 88(5): 1079-84, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16651583

RESUMO

BACKGROUND: Revision total hip arthroplasty in the setting of a large proximal segmental femoral deficiency and/or discontinuity between the proximal and distal parts of the femur remains a challenging problem. We describe the use of a cementless stem with distal cross-locking screws to provide stability of the femoral implant in this situation. METHODS: Seventeen custom fully porous and hydroxyapatite-coated titanium femoral stems with distal cross-locking titanium screws were implanted in sixteen patients during revision total hip arthroplasty. Preoperatively, all of the patients had Paprosky grade-IIIB or IV femoral deficiencies. At the time of follow-up, the Harris hip scores were calculated and radiographs were made. A successful result was defined as a postoperative increase in the Harris hip score of >20 points, a radiographically stable implant, and no additional femoral reconstruction. RESULTS: At the time of final follow-up, at a mean of 5.3 years postoperatively, the result was successful in sixteen of the seventeen hips, the mean Harris hip score had improved from 35 to 76 points, and all implants were clinically and radiographically stable. There were no postoperative infections or hip dislocations. CONCLUSIONS: The use of a custom femoral stem with distal cross-locking screws can provide at least intermediate-term clinical and radiographic stability in patients with Paprosky grade-IIIB or IV femoral deficiencies. Longer follow-up will be required to determine the longevity of these implants.


Assuntos
Artroplastia de Quadril , Parafusos Ósseos , Prótese de Quadril , Adulto , Idoso , Feminino , Fraturas do Fêmur/cirurgia , Fêmur/patologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
16.
J Bone Joint Surg Am ; 88(3): 553-8, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16510822

RESUMO

BACKGROUND: Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. METHODS: We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. RESULTS: Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). CONCLUSIONS: We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.


Assuntos
Artrodese/instrumentação , Artrodese/métodos , Artroplastia do Joelho/efeitos adversos , Pinos Ortopédicos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Infecções por Pseudomonas/etiologia , Infecções por Pseudomonas/cirurgia , Reoperação , Estudos Retrospectivos , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/cirurgia , Falha de Tratamento
17.
Clin Sports Med ; 25(1): 105-15, ix, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16324977

RESUMO

Stress fractures of the lower extremities are common, especially in the younger athletic population. The current literature consists mainly a variety of case reports but is devoid of any sizeable series of knee stress fracture investigations. Diagnosing a stress fracture around the knee can be a challenge. The proximity of the stress fracture to the knee joint may lead the clinician to investigate intra-articular or other periarticular pathology. The differential diagnosis can be large, including bursitis, tendonitis, mechanical causes, insufficiency fracture, and tumor. A high index of suspicion is necessary to confirm the underlying diagnosis. A patient's medical history combined with a physical examination and imaging modalities will aid the physician in arriving at the diagnosis of stress fracture.


Assuntos
Traumatismos em Atletas/diagnóstico , Traumatismos em Atletas/terapia , Fraturas de Estresse/diagnóstico , Fraturas de Estresse/terapia , Traumatismos do Joelho/diagnóstico , Traumatismos do Joelho/terapia , Adulto , Traumatismos em Atletas/fisiopatologia , Fenômenos Biomecânicos , Criança , Feminino , Fraturas do Fêmur/diagnóstico , Fraturas do Fêmur/fisiopatologia , Fraturas do Fêmur/terapia , Fíbula/lesões , Fraturas de Estresse/fisiopatologia , Humanos , Traumatismos do Joelho/fisiopatologia , Masculino , Patela/lesões , Fatores de Risco , Medicina Esportiva/métodos , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/fisiopatologia , Fraturas da Tíbia/terapia
18.
J Knee Surg ; 17(3): 141-3, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15366268

RESUMO

Two observers measured the tibiofemoral angle of 60 knees on hip-knee-ankle and anteroposterior (AP) knee radiographs and repeated the measurements 6 months later. Intraobserver reproducibility was moderate. Interobserver reliability was poor. These findings were the same irrespective of which radiograph was used during the measurement. Hence, although an AP knee radiograph was as reliable and reproducible as the hip-knee-ankle view, the radiographic tibiofemoral angle should not be considered a precise measurement.


Assuntos
Mau Alinhamento Ósseo/diagnóstico , Fêmur/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Extremidade Inferior/anatomia & histologia , Tíbia/diagnóstico por imagem , Fêmur/anatomia & histologia , Humanos , Articulação do Joelho/anatomia & histologia , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Tíbia/anatomia & histologia
19.
Skeletal Radiol ; 33(2): 102-6, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14605772

RESUMO

Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures.


Assuntos
Traumatismos dos Tendões/diagnóstico , Idoso , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ruptura/diagnóstico
20.
Anesth Analg ; 95(6): 1596-600, table of contents, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12456423

RESUMO

UNLABELLED: Minidose lidocaine-fentanyl spinal anesthesia (SAB(MLF)) is a safe, effective, and efficient anesthetic for ambulatory surgery. Unfortunately, it has a frequent incidence of pruritus and a substantial incidence of nausea and vomiting. Nalbuphine is effective in treating or preventing pruritus after intrathecal or epidural morphine but may or may not have a beneficial effect on nausea and vomiting. Droperidol has demonstrated antiemetic efficacy with neuraxial opiates. In this study, we examined the prophylactic use of nalbuphine alone compared with nalbuphine with droperidol after SAB(MLF). One-hundred-twenty-four patients having outpatient knee arthroscopy under SAB(MLF) with 20 mg of lidocaine 0.5% and 20 micro g of fentanyl were randomized to receive IV at the end of surgery either 4 mg of nalbuphine (Group N) or droperidol 0.625 mg plus nalbuphine 4 mg (Group ND). The incidences of early (before discharge) and late onset nausea were, respectively, 18% versus 5% and 32% versus 13%. The postoperative incidences of pruritus were 61% versus 40%, whereas 19% of patients in Group N compared with 2% of patients in Group ND requested treatment for this. Group ND had lower pain scores and had a longer delay until first use of analgesic. There were no differences in average times to discharge. The only side effect of the medications was an increased drowsiness in Group ND. In conclusion, as prophylactic medication for use in conjunction with SAB(MLF), the addition of droperidol 0.625 mg to nalbuphine 4 mg was superior to nalbuphine alone. The combination provided for reduced postoperative nausea, pruritus, and pain-benefits that persisted after discharge home. The combination also avoided isolated cases of extreme delay in discharge. IMPLICATIONS: Droperidol in combination with nalbuphine enhances analgesia and is more effective than nalbuphine alone in preventing pruritus, nausea, and vomiting after minidose lidocaine-fentanyl spinal anesthesia.


Assuntos
Raquianestesia/métodos , Droperidol/administração & dosagem , Fentanila/administração & dosagem , Lidocaína/administração & dosagem , Nalbufina/uso terapêutico , Adulto , Idoso , Procedimentos Cirúrgicos Ambulatórios , Quimioterapia Combinada , Eletrocardiografia , Feminino , Fentanila/efeitos adversos , Humanos , Lidocaína/efeitos adversos , Masculino , Pessoa de Meia-Idade , Nalbufina/administração & dosagem , Náusea e Vômito Pós-Operatórios/prevenção & controle , Prurido/induzido quimicamente , Prurido/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA