Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Knee Surg ; 37(11): 765-772, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38677298

RESUMO

Printed porous titanium metaphyseal cones have become a mainstay for managing bone loss in revision total knee arthroplasty (rTKA). A short or long stem is routinely used when implanting a cone to augment fixation and offload stresses. This retrospective analysis compared the short-term survivorships and functional outcomes for use of a short or long stem with a metaphyseal cone.A total of 179 cases using metaphyseal cones and stems with median follow-up of 1.95 years (interquartile range, 1.00-2.14) were compared based on stem type. There were 55 cases with long stem(s) and 124 cases with short stem(s). Cases with both long and short stems were excluded. Demographics, Kaplan-Meier survivorships, and preoperative and 1-year postoperative patient-reported outcome measures (PROMs; 2011 Knee Society Score [KSS] objective knee score, function, and satisfaction scores; EuroQol five-dimension scale; and Short Form Survey Physical Component Summary and Mental Component Summary scores) were compared using t-tests with a significance level of α = 0.05. There were no significant differences in body mass index (mean ± standard deviation) or sex (men [%]) between the short and long stem cohorts (32.3 ± 5.3, 36.3% and 31.5 ± 5.5, 38.2%, respectively; p > 0.05). Patients who had short stems were younger (65.9 ± 8.8 vs. 69.0 ± 9.4, p = 0.0323).Revision-free survivorship for the femoral or tibial component was 100% for long stems and 98.2% for short stems at 1 and 2 years, respectively (log-rank p = 0.6330). The two revisions in the short group were for infection, thus the survivorship for aseptic loosening was 100% at 2 years for both cohorts. There were no significant differences in preoperative or postoperative PROMs.This study demonstrated that highly porous printed metaphyseal cones provided rTKA with excellent early survivorship and similar PROMs whether a short or long stem was used. Additional studies will be needed to discern longer term differences.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Reoperação , Humanos , Artroplastia do Joelho/instrumentação , Estudos Retrospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Falha de Prótese , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia
2.
J Knee Surg ; 34(7): 730-738, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31731324

RESUMO

Approximately 20% of the patients are dissatisfied with their total knee arthroplasty (TKA). Computer technology has been introduced for TKA to provide real time intraoperative information on limb alignment and exact flexion/extension gap measurements. The purpose of this study was to determine if patient satisfaction could be improved with the use of robotic-assisted (RA) technology following primary TKA. A total of 120 consecutive patients undergoing RA-TKA with real time intraoperative alignment and gap balancing information were compared with a prospective cohort of 103 consecutive patients undergoing TKA with manual jig-based instruments during the same time period. There were no differences between groups with age, gender, baseline Knee Society Score (KSS) knee and function scores, follow-up, and ASA scores. TKAs were performed using same technique, implant design, anesthesia, and postoperative treatment protocols. Patient satisfaction survey using KSS and Likert scoring system were obtained at 1-year follow-up. Likert scoring system demonstrated 94% of the patients in the RA group were either very satisfied or satisfied versus 82% in the manual instruments TKA group (p = 0.005). RA-TKA group had better average scores of all five satisfaction questions although not significant. RA-TKA group had a better average overall satisfaction score of 7.1 versus 6.6 in the manual instrument group, p = 0.03. KSS function scores were significantly better at 6 weeks and 1 year postoperatively (p = 0.02, 0.005), and KSS knee scores were significantly better at 1 year postoperatively (p = 0.046). There are multiple reasons for patient dissatisfaction following primary TKA. Using intraoperative computer technology with RA surgery for patients undergoing a primary TKA, a significant improvement in patient satisfaction was demonstrated compared with TKA using conventional manual jig-based instruments. RA surgery provides several advantages in TKA including real time information in millimeters to help obtain balanced gaps, accurate bone cuts, reduced soft tissue injury, and achieve the target alignment which may lead to improved patient satisfaction.


Assuntos
Artroplastia do Joelho/métodos , Satisfação do Paciente , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Lesões dos Tecidos Moles/cirurgia
3.
J Arthroplasty ; 34(10): 2439-2443, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31000405

RESUMO

BACKGROUND: Highly porous metaphyseal cones have been introduced to restore metaphyseal integrity for improved cement interdigitation to achieve durable fixation in revision total knee arthroplasty (TKA). The purpose of this study is to review the survivorship, clinical results, and complications of revision TKA using highly porous 3-dimensionally printed titanium metaphyseal cones. METHODS: This is a review of 62 revision TKAs using metaphyseal tibial cones, with 15 cases utilizing both tibial and femoral cones. The mean age of the patients was 66 years (range 32-84) who had a mean follow-up of 27 months (range 24-34). There were 38 women and 24 men, who had a mean body mass index of 33 (range 18.3-62). RESULTS: Revision-free survival of the cones was 90.2%. If infection was excluded, survivorship was 100%. There were no cases of aseptic loosening. The mean Knee Society Score improved from 51 points preoperatively to 80 points at the time of latest follow-up. The mean Knee Society Functional Score improved from 48 points preoperatively to 68 points. A total of 15 of the 62 patients (24%) required additional surgery: 10 (16%) for infection, 3 (5%) for contracture, 1 for patellar subluxation, and 1 for quadriceps tendon rupture. CONCLUSION: Metaphyseal fixation is important for survivorship in revision TKA which can be challenging due to cancellous and structural bone loss encountered at the time of revision. Prosthetic joint infection continues to be the leading cause of failure in revision TKA. The use of highly porous titanium metaphyseal cones produced from 3-dimensionally printed technology used in this study demonstrated excellent short-term results with no cases of aseptic loosening. Further follow-up is required to determine if these results can be durable over a longer period.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Prótese do Joelho , Reoperação , Adulto , Idoso , Idoso de 80 Anos ou mais , Contratura , Feminino , Fêmur/cirurgia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Tíbia/cirurgia , Titânio
4.
J Orthop Trauma ; 32(7): 338-343, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29738399

RESUMO

OBJECTIVES: To determine the independent risk factors associated with increasing costs and unplanned hospital readmissions in the 90-day episode of care (EOC) for isolated operative ankle fractures at our institution. DESIGN: Retrospective cohort study. SETTING: Level I Trauma Center. PATIENTS: Two hundred ninety-nine patients undergoing open reduction internal fixation for the treatment of an acute, isolated ankle fracture between 2010 and 2015. INTERVENTION: None. MAIN OUTCOME MEASURES: Independent risk factors for increasing 90-day EOC costs and unplanned hospital readmission rates. RESULTS: Orthopaedic (64.9%) and podiatry (35.1%) patients were included. The mean index admission cost was $14,048.65 ± $5,797.48. Outpatient cases were significantly cheaper compared to inpatient cases ($10,164.22 ± $3,899.61 vs. $15,942.55 ± $5,630.85, respectively, P < 0.001). Unplanned readmission rates were 5.4% (16/299) and 6.7% (20/299) at 30 and 90 days, respectively, and were often (13/20, 65.0%) due to surgical site infections. Independent risk factors for unplanned hospital readmissions included treatment by the podiatry service (P = 0.024) and an American Society of Anesthesiologists score of ≥3 (P = 0.017). Risk factors for increasing total postdischarge costs included treatment by the podiatry service (P = 0.011) and male gender (P = 0.046). CONCLUSIONS: Isolated operative ankle fractures are a prime target for EOC cost containment strategy protocols. Our institutional cost analysis study suggests that independent financial clinical risk factors in this treatment cohort includes podiatry as the treating surgical service and patients with an American Society of Anesthesiologists score ≥3, with the former also independently increasing total postdischarge costs in the 90-day EOC. Outpatient procedures were associated with about a one-third reduction in total costs compared to the inpatient subgroup.


Assuntos
Fraturas do Tornozelo/economia , Fixação Interna de Fraturas/economia , Custos Hospitalares , Tempo de Internação/economia , Readmissão do Paciente/economia , Centros Médicos Acadêmicos , Adulto , Idoso , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Estudos de Coortes , Análise Custo-Benefício , Feminino , Fixação Interna de Fraturas/métodos , Hospitalização/economia , Hospitais Urbanos , Humanos , Escala de Gravidade do Ferimento , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Centros de Traumatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA