Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Surg Res (Houst) ; 5(4): 626-631, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36777917

RESUMO

Polytrauma is a major cause of death in young adults. The trial was to identify clusters of interlinked anatomical regions to improve strategical operational planning in the acute situation. A total of 2219 polytrauma patients with an ISS (Injury Severity Score) ≥ 16 and an age ≥ 16 years was included into this retrospective cohort study. Pearson's correlation was performed amongst the AIS (Abbreviated Injury Scale) groups. The predictive quality was tested by ROC (Receiver Operating Curve) and their area under the curve. Independency was tested by the binary logistic regression, AIS ≥3 was taken as a significant injury. The analysis was conducted using IBM SPSS® 24.0. The highest predictive value was reached in the combination of thorax, abdomen, pelvis and spine injuries (ROC: abdomen for thorax 0.647, thorax for abdomen 0.621, pelvis for thorax 0.608, pelvis for abdomen 0.651, spine for thorax 0.617). The binary logistic regression revealed the anatomical regions thorax, abdomen pelvis and spine as per-mutative independent predictors for each other when a particular injury exceeded the AIS ≥3. The documented clusters of injuries in truncal trauma are crucial to define priorities in the polytrauma management.

2.
Surg Neurol Int ; 12: 496, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34754546

RESUMO

BACKGROUND: While pyogenic spondylodiscitis due to Gram-positive aerobic bacteria and its treatment is well known, spondylodiscitis caused by anaerobic Gram-negative pathogen is rare. In particular, the spondylodiscitis caused by Veillonella species is an absolute rarity. Thus no established management recommendations exist. CASE DESCRIPTION: A case report of a 79-year-old man with spondylodiscitis caused by Veillonella parvula with intramuscular abscess collection managed conservatively with stand-alone antibiotic therapy without a spinal stabilization procedure. A review of literature of all reported spondylodiscitis caused by Veillonella species was performed. After 3 week-intravenous therapy with the ceftriaxone in combination with the metronidazole followed by 3 weeks per oral therapy with amoxicillin/clavulanate, the complete recovery of the patient with the V. parvula infection was achieved. CONCLUSION: Treatment of the spondylodiscitis caused by Veillonella species should contain a beta-lactam with beta-lactamase inhibitor or third-generation cephalosporine. Six weeks of treatment seem to be sufficient for the complete recovery of the patient.

3.
BMC Musculoskelet Disord ; 22(1): 451, 2021 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-34006234

RESUMO

BACKGROUND: Augmented Reality (AR) is a rapidly emerging technology finding growing acceptance and application in different fields of surgery. Various studies have been performed evaluating the precision and accuracy of AR guided navigation. This study investigates the feasibility of a commercially available AR head mounted device during orthopedic surgery. METHODS: Thirteen orthopedic surgeons from a Swiss university clinic performed 25 orthopedic surgical procedures wearing a holographic AR headset (HoloLens, Microsoft, Redmond, WA, USA) providing complementary three-dimensional, patient specific anatomic information. The surgeon's experience of using the device during surgery was recorded using a standardized 58-item questionnaire grading different aspects on a 100-point scale with anchor statements. RESULTS: Surgeons were generally satisfied with image quality (85 ± 17 points) and accuracy of the virtual objects (84 ± 19 point). Wearing the AR device was rated as fairly comfortable (79 ± 13 points). Functionality of voice commands (68 ± 20 points) and gestures (66 ± 20 points) provided less favorable results. The greatest potential in the use of the AR device was found for surgical correction of deformities (87 ± 15 points). Overall, surgeons were satisfied with the application of this novel technology (78 ± 20 points) and future access to it was demanded (75 ± 22 points). CONCLUSION: AR is a rapidly evolving technology with large potential in different surgical settings, offering the opportunity to provide a compact, low cost alternative requiring a minimum of infrastructure compared to conventional navigation systems. While surgeons where generally satisfied with image quality of the here tested head mounted AR device, some technical and ergonomic shortcomings were pointed out. This study serves as a proof of concept for the use of an AR head mounted device in a real-world sterile setting in orthopedic surgery.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Estudos de Viabilidade , Humanos , Salas Cirúrgicas
4.
Int J Spine Surg ; 15(1): 161-168, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33900970

RESUMO

BACKGROUND: Sacral-alar-iliac (SAI) screws are increasingly used for lumbo-pelvic fixation procedures. Insertion of SAI screws is technically challenging, and surgeons often rely on costly and time-consuming navigation systems. We investigated the accuracy and precision of an augmented reality (AR)-based and commercially available head-mounted device requiring minimal infrastructure. METHODS: A pelvic sawbone model served to drill pilot holes of 80 SAI screw trajectories by 2 surgeons, randomly either freehand (FH) without any kind of navigation or with AR navigation. The number of primary pilot hole perforations, simulated screw perforation, minimal axis/outer cortical wall distance, true sagittal cranio-caudal inclination angle (tSCCIA), true axial medio-lateral angle, and maximal screw length (MSL) were measured and compared to predefined optimal values. RESULTS: In total, 1/40 (2.5%) of AR-navigated screw hole trajectories showed a perforation before passing the inferior gluteal line compared to 24/40 (60%) of FH screw hole trajectories (P < .05). The differences between FH- and AR-guided holes compared to optimal values were significant for tSCCIA with -10.8° ± 11.77° and MSL -65.29 ± 15 mm vs 55.04 ± 6.76 mm (P = .001). CONCLUSIONS: In this study, the additional anatomical information provided by the AR headset and the superimposed operative plan improved the precision of drilling pilot holes for SAI screws in a laboratory setting compared to the conventional FH technique. Further technical development and validation studies are currently being performed to investigate potential clinical benefits of the AR-based navigation approach described here. LEVEL OF EVIDENCE: 4.

5.
J Orthop Surg Res ; 15(1): 540, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33203429

RESUMO

BACKGROUND: The Ganz' periacetabular osteotomy (PAO) consists of four technically challenging osteotomies (OT), namely, supraacetabular (saOT), pubic (pOT), ischial (iOT), and retroacetabular OT (raOT). PURPOSE: We performed a proof of concept study to test (1) the feasibility of augmented reality (AR) guidance for PAO, (2) precision of the OTs guided by AR compared to the freehand technique performed by an experienced PAO surgeon, and (3) the effect of AR on performance depending on experience. METHODS: A 3D preoperative plan of a PAO was created from segmented computed tomography (CT) data of an anatomic plastic pelvis model (PPM). The plan was then embedded in a software application for an AR head-mounted device. Soft tissue coverage was imitated using foam rubber. The 3D plan was then registered onto the PPM using an anatomical landmark registration. Two surgeons (one experienced and one novice PAO surgeon) each performed 15 freehand (FH) and 15 AR-guided PAOs. The starting point distances and angulation between the planned and executed OT planes for the FH and the AR-guided PAOs were compared in post-intervention CTs. RESULTS: AR guidance did not affect the performance of the expert surgeon in terms of the mean differences between the planned and executed starting points, but the raOT angle was more accurate as compared to FH PAO (p = 0.0027). AR guidance increased the accuracy of the performance of the novice surgeon for iOT (p = 0.03). An intraarticular osteotomy performed by the novice surgeon with the FH technique could be observed only once. CONCLUSION: AR guidance of osteotomies for PAOs is feasible and seems to increase accuracy. The effect is more accentuated for less-experienced surgeons. CLINICAL RELEVANCE: This is the first proof of concept study documenting the feasibility of AR guidance for PAO. Based on these findings, further studies are essential for elaborating on the potential merits of AR guidance to increase the accuracy of complex surgical procedures.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Realidade Aumentada , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Osteotomia/métodos , Cirurgia Assistida por Computador/métodos , Estudos de Viabilidade , Luxação do Quadril/cirurgia , Humanos , Modelos Anatômicos
6.
BMC Musculoskelet Disord ; 21(1): 438, 2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32631342

RESUMO

BACKGROUND: An optimal osteotomy angle avoids shortening of the first metatarsal bone after hallux valgus surgery and therefore reduces the risk of transfer-metatarsalgia. The purpose of the present ex-vivo study was to investigate whether augmented reality (AR) would improve accuracy of the distal osteotomy during hallux valgus surgery. METHODS: Distal osteotomies of the first metatarsals were performed on a foot model by two surgeons with different levels of surgical experience each with (AR, n = 15 × 2) or without (controls, n = 15 × 2) overlay of a hologram depicting an angle of osteotomy perpendicular to the second metatarsal. Subsequently, the deviation of the osteotomy angle in the transverse plane was analyzed. RESULTS: Overall, AR decreased the extent of deviation and the AR guided osteotomies were more accurate (4.9 ± 4.2°) compared to the freehand cuts (6.7 ± 6.1°) by tendency (p = 0.2). However, while the inexperienced surgeon performed more accurate osteotomies with AR with a mean angle of 6.4 ± 3.5° compared to freehand 10.5 ± 5.5° (p = 0.02), no significant difference was noticed for the experienced surgeon with an osteotomy angle of around 3° in both cases. CONCLUSION: This pilot-study suggests that AR guided osteotomies can potentially improve accuracy during hallux valgus correction, particularly for less experienced surgeons.


Assuntos
Realidade Aumentada , Hallux Valgus/cirurgia , Ossos do Metatarso/cirurgia , Osteotomia/métodos , Humanos , Projetos Piloto
7.
J Orthop Surg Res ; 15(1): 174, 2020 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-32410636

RESUMO

BACKGROUND: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique. METHODS: Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agar-based gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method. RESULTS: The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044). Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively (p > 0.005). Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws (p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23° (STD 4.90) and 0.62° (STD 4.56) for the FH and AR set screws (p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category (p = 0.04) with AR. CONCLUSION: In this study, the additional anatomical information provided by the AR headset superimposed to real-world anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon's experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach.


Assuntos
Realidade Aumentada , Imageamento Tridimensional/métodos , Neuronavegação/métodos , Parafusos Pediculares , Cirurgia Assistida por Computador/métodos , Corpo Vertebral/cirurgia , Humanos , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/cirurgia , Neuronavegação/instrumentação , Distribuição Aleatória , Cirurgia Assistida por Computador/instrumentação , Corpo Vertebral/anatomia & histologia
8.
Invest Radiol ; 53(8): 495-498, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29742535

RESUMO

OBJECTIVES: The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. MATERIALS AND METHODS: A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. RESULTS: In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). CONCLUSIONS: Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.


Assuntos
Imagens de Fantasmas , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Articulação Zigapofisária/diagnóstico por imagem , Estudos de Viabilidade , Injeções , Região Lombossacral , Reprodutibilidade dos Testes
9.
Spine (Phila Pa 1976) ; 43(15): 1089-1094, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29300251

RESUMO

STUDY DESIGN: A prospective multicenter cohort study. OBJECTIVES: This study evaluates the risk for surgical site infections (SSIs) or wound healing problems (WHPs) in patients who underwent corticosteroid injection before lumbar decompression surgery. SUMMARY OF BACKGROUND DATA: Corticosteroid injections are often used for the treatment of the degenerated spine. However, their well-known immunosuppressive effects could increase the risk for local infections, particularly if a surgical intervention follows the injection rapidly. METHODS: The Swiss Lumbar Stenosis Outcome Study (LSOS), which is a prospective multicenter cohort study of patients with symptomatic lumbar spinal stenosis, was used as database. Of 743 patients, 422 patients underwent surgery and were eligible for the study. Ten patients (2.4%) were revised for either SSIs (n = 6) or WHPs (n = 4). A control group (n = 19) was constructed matched according to age, sex, diabetes, and body mass index (BMI). Odds ratios (ORs) were calculated by using a conditional logistic regression model to quantify the risk of SSI or WHP after preoperative corticosteroid injection. Subgroup analysis was performed for patients with injection within 0 to 3 months before surgery, 0 to 6 months before surgery, or any injection at all before surgery. RESULTS: Within this cohort, no significant association could be found between preoperative corticosteroid injection and postoperative SSI or WHP in patients with corticosteroid injections within 0 to 3 months before surgery [OR = 0.36, 95% confidence interval (95% CI) 0.04-3.22], 0 to 6 months before surgery (OR = 0.69 95% CI 0.14-3.49), or any time before surgery (OR = 0.43, 95% CI 0.04-3.22). CONCLUSION: Within the here investigated cohort, the risk of SSIs or WHPs following lumbar spinal decompression surgery seems not highly associated with preoperative corticosteroid injections. However, the safe time interval between corticosteroid infiltrations and surgery remains unknown, should not be decreased incautiously, and is the subject of further research. LEVEL OF EVIDENCE: 2.


Assuntos
Corticosteroides/efeitos adversos , Descompressão Cirúrgica/efeitos adversos , Vértebras Lombares/cirurgia , Estenose Espinal/cirurgia , Infecção da Ferida Cirúrgica/etiologia , Cicatrização/efeitos dos fármacos , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Suíça
10.
Cytotherapy ; 16(10): 1345-60, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24972742

RESUMO

BACKGROUND AIMS: Stem cells participate in vascular regeneration following critical ischemia. However, their angiogenic and remodeling properties, as well as their role in ischemia-related endothelial leukocyte activation, need to be further elucidated. Herein, we investigated the effect of bone marrow-derived mesenchymal stromal cells (BM-MSCs) in a critically ischemic murine skin flap model. METHODS: Groups received either 1 × 10(5), 5 × 10(5), or 1 × 10(6) BM-MSCs or cell-free conditioned medium (CM). Controls received sodium chloride. Intravital fluorescence microscopy was performed for morphological and quantitative assessment of micro-hemodynamic parameters over 12 days. RESULTS: Tortuosity and diameter of conduit-arterioles were pronounced in the MSC groups (P < 0.01), whereas vasodilation was shifted to the end arteriolar level in the CM group (P < 0.01). These effects were accompanied by angiopoietin-2 expression. Functional capillary density and red blood cell velocity were enhanced in all treatment groups (P < 0.01). Although a significant reduction of rolling and sticking leukocytes was observed in the MSC groups with a reduction of diameter in postcapillary venules (P < 0.01), animals receiving CM exhibited a leukocyte-endothelium interaction similar to controls. This correlated with leukocyte common antigen expression in tissue sections (P < 0.01) and p38 mitogen-activated protein kinase expression from tissue samples. Cytokine analysis from BM-MSC culture medium revealed a 50% reduction of pro-inflammatory cytokines (interleukin [IL]-1ß, IL-6, IL-12, tumor necrosis factor-α, interferon-γ) and chemokines (keratinocyte chemoattractant, granulocyte colony-stimulating factor) under hypoxic conditions. DISCUSSION: We demonstrated positive effects of BM-MSCs on vascular regeneration and modulation of endothelial leukocyte adhesion in critical ischemic skin. The improvements after MSC application were dose-dependent and superior to the use of CM alone.


Assuntos
Células da Medula Óssea/fisiologia , Capilares/fisiologia , Endotélio/fisiologia , Isquemia , Leucócitos/fisiologia , Células-Tronco Mesenquimais/fisiologia , Regeneração/fisiologia , Pele/irrigação sanguínea , Animais , Capilares/patologia , Comunicação Celular , Células Cultivadas , Endotélio/metabolismo , Feminino , Isquemia/patologia , Isquemia/fisiopatologia , Leucócitos/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Pele/imunologia
11.
Microvasc Res ; 83(3): 267-75, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22391452

RESUMO

New theories on the regeneration of ischemic vasculature have emerged indicating a pivotal role of adult stem cells. The aim of this study was to investigate homing and hemodynamic effects of circulating bone marrow-derived mesenchymal stem cells (MSCs) in a critically ischemic murine skin flap model. Bone marrow-derived mesenchymal stem cells (Lin(-)CD105(+)) were harvested from GFP(+)-donor mice and transferred to wildtype C57BL/6 mice. Animals receiving GFP(+)-fibroblasts served as a control group. Laser scanning confocal microscopy and intravital fluorescence microscopy were used for morphological analysis, monitoring and quantitative assessment of the stem cell homing and microhemodynamics over two weeks. Immunohistochemical staining was performed for GFP, eNOS, iNOS, VEGF. Tissue viability was analyzed by TUNEL-assay. We were able to visualize perivascular homing of MSCs in vivo. After 4 days, MSCs aligned along the vascular wall without undergoing endothelial or smooth muscle cell differentiation during the observation period. The gradual increase in arterial vascular resistance observed in the control group was abolished after MSC administration (P<0.01). At capillary level, a strong angiogenic response was found from day 7 onwards. Functional capillary density was raised in the MSC group to 197% compared to 132% in the control group (P<0.01). Paracrine expression of VEGF and iNOS, but not eNOS could be shown in the MSC group but not in the controls. In conclusion, we demonstrated that circulating bone marrow-derived MSCs home to perivascular sites in critically ischemic tissue, exhibits paracrine function and augment microhemodynamics. These effects were mediated through arteriogenesis and angiogenesis, which contributed to vascular regeneration.


Assuntos
Vasos Sanguíneos/patologia , Células-Tronco Mesenquimais/citologia , Pele/patologia , Animais , Endoglina , Feminino , Proteínas de Fluorescência Verde/metabolismo , Hemodinâmica , Imuno-Histoquímica/métodos , Marcação In Situ das Extremidades Cortadas , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Confocal/métodos , Comunicação Parácrina , Reprodutibilidade dos Testes , Fator A de Crescimento do Endotélio Vascular/metabolismo
12.
J Surg Res ; 162(2): 308-13, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19592025

RESUMO

In surgical animal studies anesthesia is used regularly. Several reports in the literature demonstrate respiratory and cardiovascular side effects of anesthesiologic agents. The aim of this study was to compare two frequently used anesthesia cocktails (ketamine/xylazine [KX] versus medetomidine/climazolam/fentanyl [MCF]) in skin flap mouse models. Systemic blood values, local metabolic parameters, and surgical outcome should be analyzed in critical ischemic skin flap models. Systemic hypoxia was found in the animals undergoing KX anesthesia compared with normoxia in the MCF group (sO(2): 89.2% +/- 2.4% versus 98.5% +/- 1.2%, P < 0.01). Analysis of tissue metabolism revealed impaired anaerobic oxygen metabolism and increased cellular damage in critical ischemic flap tissue under KX anesthesia (lactate/pyruvate ratio: KX 349.86 +/- 282.38 versus MCF 64.53 +/- 18.63; P < 0.01 and glycerol: KX 333.50 +/- 83.91 micromol/L versus MCF 195.83 +/- 29.49 micromol/L; P < 0.01). After 6 d, different rates of flap tissue necrosis could be detected (MCF 57% +/- 6% versus KX 68% +/- 6%, P < 0.01). In summary we want to point out that the type of anesthesia, the animal model and the goal of the study have to be well correlated. Comparing the effects of KX and MCF anesthesia in mice on surgical outcome was a novel aspect of our study.


Assuntos
Anestesia/métodos , Isquemia/patologia , Dermatopatias/patologia , Equilíbrio Ácido-Base , Aerobiose , Anaerobiose , Animais , Gasometria , Sobrevivência Celular , Estado Terminal , Metabolismo Energético , Hematócrito , Hemoglobinas/metabolismo , Isquemia/metabolismo , Lactatos/metabolismo , Camundongos , Camundongos Endogâmicos , Necrose , Pele/irrigação sanguínea , Pele/patologia , Dermatopatias/metabolismo , Retalhos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA