Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Eval Program Plann ; 90: 101978, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34275640

RESUMO

Etiologies of HIV disparities are multifaceted; anti-LGBTQ stigma and social marginalization are contributory factors. A city health department developed a program, #ProjectPresence, exhibiting professional photos of Black LGBTQ persons in public spaces. An academic partner explored the relationship of the program to visibility, anti-LGBTQ stigma and social marginalization of Black LGBTQ persons, i.e. models, directly involved in the program and their perceptions of these relationships more broadly for community members. Brief self-administered surveys and semi-structured, in-depth interviews with #ProjectPresence models (n = 15) were conducted after the program to gather their experiences before, during and after the program. Descriptive analyses of survey responses were conducted using Stata 15.1. Interviews were audio-recorded, transcribed and analyzed in NVivo10 using categorical analysis. Surveys indicated prevalent experiences of enacted stigma (73 %) and perceptions of poor local acceptance of LGBTQ people (53 %). Interviews suggested that the program may have influenced positive individual- and community-level changes by increasing visibility of LGBTQ communities and improving acceptance among non-LGBTQ persons, inspiring personal growth and self-acceptance among models, and providing opportunities to foster new connections among LGBTQ subpopulations. Our findings suggest similar programs may present promising approaches for the reduction of stigma and social marginalization affecting LGBTQ persons and communities.


Assuntos
Minorias Sexuais e de Gênero , Humanos , Avaliação de Programas e Projetos de Saúde , Pesquisa Qualitativa , Estigma Social
2.
J Trauma Acute Care Surg ; 90(4): 631-640, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33443983

RESUMO

BACKGROUND: Trauma registries are used to identify modifiable injury risk factors for trauma prevention efforts. However, these may miss factors useful for prevention of bicycle-automobile collisions, such as vehicle speeds, driver intoxication, street conditions, and neighborhood characteristics. We hypothesize that (GIS) analysis of trauma registry data matched with a traffic accident database could identify risk factors for bicycle-automobile injuries and better inform injury prevention efforts. METHODS: The trauma registry of a US Level I trauma center was used retrospectively to identify bicycle-motor vehicle collision admissions from January 1, 2010, to December 31, 2018. Data collected included demographics, vitals, injury severity scores, toxicology, helmet use, and mortality.Matching with the Statewide Integrated Traffic Records System was done to provide collision, victim and GIS information. The GIS mapping of collisions was done with census tract data including poverty level scoring. Incident hot spot analysis to identify statistically significant incident clusters was done using the Getis Ord Gi* statistic. RESULTS: Of 25,535 registry admissions, 531 (2.1%) were bicyclists struck by automobiles, 425 (80.0%) were matched to Statewide Integrated Traffic Records System. Younger age (odds ratio [OR], 1.026; 95% confidence interval [CI], 1.013-1.040, p < 0.001), higher census tract poverty level percentage (OR, 0.976; 95% CI, 0.959-0.993, p = 0.007), and high school or less education (OR, 0.60; 95 CI, 0.381-0.968; p = 0.036) were predictive of not wearing a helmet. Higher census tract poverty level percentage (OR, 1.019; 95% CI, 1.004-1.034; p = 0.012) but not educational level was predictive of toxicology positive-bicyclists in automobile collisions. Geographic information systems analysis identified hot spots in the catchment area for toxicology-positive bicyclists and lack of helmet use. CONCLUSION: Combining trauma registry data and matched traffic accident records data with GIS analysis identifies additional risk factors for bicyclist injury. Trauma centers should champion efforts to prospectively link public traffic accident data to their trauma registries. LEVEL OF EVIDENCE: Prognostic and Epidemiological, level III.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Ciclismo/lesões , Sistemas de Informação Geográfica , Sistema de Registros , Ferimentos e Lesões/epidemiologia , Acidentes de Trânsito/prevenção & controle , Adulto , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Traumatologia/estatística & dados numéricos , Ferimentos e Lesões/prevenção & controle , Adulto Jovem
3.
J Anaesthesiol Clin Pharmacol ; 37(4): 537-541, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35340957

RESUMO

Background and Aims: to quantify the scalp-cortex distance and determine its variation among patients. We hypothesized that in a significant number of patients, this distance is greater than the maximum penetration depth of current cerebral oximeters. Material and Methods: A retrospective anatomic study using transverse head CT images selected randomly from 102 patients over the age of 18 years without brain swelling, intracranial mass effect, or brain hemorrhage. Scalp-cortex distances were determined at two separate locations along the craniocaudal axis; most cephalad to the frontal sinus (I0) and also 2 cm cephalad to that location (I2). Multiple measurements were obtained bilaterally at 1, 3, 5, 7, and 9 cm from midline. Results: The average scalp-cortex distance was 14.3 mm and 15 mm at I0 and I2 respectively. Distances varied more in I2 than in I0; from the measurements, 12.8% vs. 6.8% were over 20 mm, 4.4% vs. 2.2% over 25 mm, 1.1% vs. 0.6% over 35 mm and 0.6% vs. none over 40 mm at I2 and I0, respectively. 1.5% of the measurements at I2 were over 30 mm. Conclusion: Cerebral oximetry manufacturers all claim to measure cerebral tissue up to a depth of 20-25 mm; 20 mm with the EQUANOX and INVOS compared with 25 mm with the FORE-SIGHT. Scalp-cortex distance is within 25 mm in more than 95% of patients. However, even with the probe placed as per the manufacturer's recommendations, in a small but significant subset of patients, this distance is greater than the maximum penetration depth of current cerebral oximeters and hence may not reflect actual brain tissue oxygen saturation.

4.
BMJ Open Qual ; 7(3): e000330, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30234172

RESUMO

Hyperemesis gravidarum is a common condition characterised by severe nausea and vomiting. The referral process from the emergency department (ED) to obstetrics and gynaecology (O&G) can lead to treatment delays before the gynaecology team review the patient, resulting in unnecessary prolonged inpatient stays in O&G. This quality improvement project created a clinical pathway which optimised care of patients presenting with hyperemesis gravidarum in the ED at the Princess Royal University Hospital using a treatment protocol. Two audits were carried out to assess improvements in patient care and reduction in admissions to O&G. Overall, admissions to O&G were reduced by 68.7% (cycle 1) and 70.5% (cycle 2) compared with admission rates before the proforma, saving the trust an estimated £265 700 and 235 bed days over a year.

5.
J Investig Med High Impact Case Rep ; 6: 2324709618781174, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29977935

RESUMO

We report an unusual case of endotracheal tube failure. It was due to a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Prior to use, the endotracheal tube was tested and functioned normally. A 64-year-old patient in the intensive care unit with a history of hypertension was being mechanically ventilated after uneventful abdominal surgery. After several hours in the intensive care unit, he was noted to be suddenly no longer receiving adequate tidal volumes from the ventilator. It was found that the cuff on the endotracheal tube was not retaining air when it was filled with air from a syringe. This lead to a large "leak" around the endotracheal tube such that the intended tidal volumes set on the ventilator were not delivered to the patient. The patient was uneventfully reintubated and did well. Subsequent investigation revealed the cause to be a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Other mechanisms of cuff failure are reviewed in this case report. This case is an unusual reason for cuff failure. Illustrations supplied alert the reader how to identify the appearance of this manufacturing defect in a pilot balloon. This case illustrates the potential device malfunctions that can develop during a procedure, even when the equipment has been tested and previously functioned well. Even small defects developing in well-engineered products can lead to critical patient care emergencies.

6.
J Investig Med High Impact Case Rep ; 6: 2324709618770230, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29707592

RESUMO

Varicella zoster virus causes varicella (chickenpox). It can be reactivated endogenously many years later to cause herpes zoster (shingles). Although varicella is usually a benign disease in healthy children, it resulted in over 11 000 hospitalizations and over 100 deaths every year, in all ages, in the United States. Morbidity was considerably worse in older teenagers and adults. Between 5% and 15% of cases of adult chickenpox will produce some form of pulmonary illness. Progression to pneumonia risk factors include pregnancy, age, smoking, chronic obstructive pulmonary disease, and immunosuppression. Typically, pulmonary symptoms occur 1 to 6 days after varicella zoster infection. They often include cough, fever, and dyspnea. Treatment is a 7-day course of intravenous acyclovir for varicella pneumonia. Early intervention may modify the course of this complication. This review illustrates practical features with a case of a 34-year-old female with severe varicella pneumonia. Despite the lack of significant past medical history and absence of immunosuppression, her pneumonia worsened and by using continuous positive airway pressure mask, intubation was avoided. More important, the radiographic progression of severe varicella pneumonia is shown. This highlights how a common disease of varicella can progress in an adult and manifest with significant organ malfunction.

7.
SAGE Open Med Case Rep ; 6: 2050313X18767228, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29623205

RESUMO

Left internal mammary artery grafting is commonly used in elective coronary artery bypass graft surgery. We report a near-fatal case with graft kinking upon sternal closure due to distended, emphysematous lungs impinging on the mammary graft. After the sternum was closed, the patient suffered a severe hemodynamic deterioration. Surgical examination revealed kinking of his left internal mammary artery upon sternal closure due to distended, emphysematous lungs impinging on the mammary graft. Using an off-bypass technique, the kink in the mammary graft to the left anterior descending artery was removed by moving the origin of the left internal mammary artery to a hooded graft of a saphenous vein graft instead. In this position, the graft no longer was impinged upon by the distended emphysematous lungs. Subsequently, the patient's sternum was closed without hemodynamic impingement. Although chronic obstructive pulmonary disease is well described to increase complications in coronary artery bypass graft surgery, it has not been previously associated with the kinking of a left internal mammary artery. This report highlights another contribution that chronic obstructive pulmonary disease can make to increased morbidity following coronary artery bypass graft surgery and alerts readers to watch for this complication in susceptible patients.

8.
Exp Ther Med ; 12(3): 1599-1603, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27588081

RESUMO

In the present study, the availability of smoking cessation programs (SCP) was surveyed in the same randomly selected USA hospitals in 2000 and 2012. A total of 102 USA hospitals were randomly selected for this survey. Each hospital website was searched for the topic of smoking cessation. In the second phase of the survey, the main switchboard number of each hospital was anonymously telephoned and the 'stop smoking clinic' was requested. The phone survey results showed that the percentage of hospital switchboard calls that were connected to a SCP remained identical at 47% in 2000 and 2012. The results for the internet availability of SCP on hospital websites improved from 30% in 2000 to 47% in 2012. There were more hospitals that added additional SCP information (27%) compared with those that removed SCP information (15%) by 2012. Among the 57% of hospitals that showed no change in internet SCP information, 22% remained positive for such information while 35% remained negative. The phone survey of hospitals showed that 47% of USA hospitals were able to connect a caller to a SCP in the years 2000 and 2012. While there was no reduction over the 12 years, there was no increase in the percentage of hospital switchboards that connected to a SCP. Availability of SCP information on hospital web sites improved to a limited extent; increasing from 30% of sites in 2000 to 47% in 2012. Providing SCP on a hospital website is easy and free, for example adding a link to QuitNet or QuitLink. The present study adds to information gathered 12 years earlier, and is unusual in being able to provide follow-up data on the same set of hospitals studied previously.

10.
J Anaesthesiol Clin Pharmacol ; 31(4): 471-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26702203

RESUMO

BACKGROUND AND AIMS: We aimed to determine the ropivacaine concentration that provided adequate analgesia with early ambulation and minimal urinary retention or other side-effects when used with fentanyl and epinephrine for patient-controlled epidural analgesia (PCEA) after elective cesarean section. MATERIAL AND METHODS: Forty-eight patients were randomized to four groups in a double-blinded fashion. All groups received an initial 10 ml/h of epidural study solution for 24 h. The solution contained: 0.2, 0.1, 0.05, or 0.025% ropivacaine for Groups I-IV, respectively, with fentanyl 3.0 µg/ml and epinephrine 0.5 µg/ml. Patients could administer additional PCEA doses of 4 ml of their study solution with a lock-out time of 10 min. Overall satisfaction, side-effects, motor block, neurologic function, and pain using Visual Analog Scale were assessed. RESULTS: Patients in all groups showed no difference in sedation, pruritus, nausea, vomiting, and uterine cramps. Pain scores at rest were lower for Group IV than Groups I-III (P < 0.001). Twelve, five, one, and zero patients could not ambulate in Groups I-IV, respectively. Nine, nine, two, and zero (III

11.
A A Case Rep ; 5(12): 216-8, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26657701

RESUMO

Monitoring of cerebral perfusion by near-infrared spectroscopy estimates regional cerebral oxygen saturation (rSO2). We present a case in which, before clamping the left carotid artery during an endarterectomy, the right and left rSO2 measurements were 72% and 74%, respectively. Within 15 seconds of clamping the external carotid artery, the left rSO2 decreased by 8%, yielding right and left rSO2 measurements of 70% and 66%, respectively. No electroencephalogram changes ensued. The internal carotid artery was clamped 1 minute later, whereas the external carotid remained clamped. No electroencephalogram changes were observed. The rSO2 measurements demonstrate that the value of this cerebral oximetry is not determined solely from internal carotid blood flow and can be significantly affected by the external carotid.


Assuntos
Artéria Carótida Externa , Artéria Carótida Interna , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Oximetria/métodos , Oxigênio/sangue , Idoso de 80 Anos ou mais , Isquemia Encefálica/prevenção & controle , Estenose das Carótidas/sangue , Circulação Cerebrovascular , Constrição , Eletroencefalografia , Humanos , Masculino , Monitorização Intraoperatória/métodos
13.
Exp Ther Med ; 9(5): 1915-1920, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26136914

RESUMO

Rabbit anti-thymocyte globulin (rATG) is an infusion of polyclonal rabbit-derived antibodies against human thymocyte markers, which can be used to prevent and treat acute rejection following organ transplantation. However, the product monograph issued by the manufacturer (Sanofi Canada) reports that serious immune-mediated reactions have been observed following the use of rATG, consisting of anaphylaxis or severe cytokine release syndrome (CRS), which is a form of vasoplegic syndrome (VS), in which distributive shock occurs refractory to norepinephrine (NE) and vasopressin (VP). Severe infusion-associated reactions are consistent with CRS and can cause serious cardiac or respiratory problems, or in certain cases, mortality. CRS is a form of systemic inflammatory response syndrome (SIRS). In SIRS, the substantial activation of endothelial inducible nitric oxide synthase (iNOS) and smooth muscle guanylate cyclase (GC) is observed, which can produce severe hypotension that is unresponsive to conventional vasopressors. Methylene blue (MB) is a direct inhibitor of iNOS and GC and has been used as an effective treatment for VS following cardiothoracic surgery. In the present study, the successful use of MB as a rescue therapy for CRS in a patient receiving rATG following a renal transplant was reported. Following an uneventful cadaveric kidney transplant involving the intravenous (IV) administration of rATG for the induction of immunological tolerance, the patient became markedly hypotensive and tachycardic. The patient required high doses of VP and NE infusions. Following the protocol described for treating refractory VS in post-cardiac surgery patients, the decision was made to initiate the patient on an IV MB infusion. This treatment protocol was shown to improve the hemodynamic status of the patient, which enabled the withdrawal of vasopressors and suggests an important role for methylene blue in the management of refractory VS.

14.
J Cardiothorac Vasc Anesth ; 29(5): 1257-60, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25998069

RESUMO

OBJECTIVES: The aim of this study was to determine the degree of head rotation that creates the maximal anatomic separation between the right internal jugular vein and the carotid artery. DESIGN: Single-center prospective, observational cohort study. SETTING: University medical center. PARTICIPANTS: Fifty patients aged>21 years and undergoing cardiac surgery. INTERVENTIONS: An ultrasound machine equipped with a digital caliper was used to determine the relational anatomy of the internal jugular vein and the carotid artery, with patients in the Trendelenburg position at head angles of -15°, 0°,+15°,+30°,+45°,+60°,+75°, and+90°. MEASUREMENTS AND MAIN RESULTS: When examining the percentage of the internal jugular vein vertical diameter that is not overlapped by the carotid artery (vertically unencumbered), there was a difference between the head angle groups (p<0.01). Unencumbered vertical distance was different between+75° versus 0°, and+75° versus+15°. At+75°, 60.3%±5.3% of the internal jugular vein was unencumbered vertically, whereas at 0°, it was 37.2%±3.9%, and at+15° it was 40.3%±3.8%. Only 72% of the patients were able to position their head at+75°, and 54% of the subjects were able to position their head at+90°. CONCLUSION: The authors found the internal jugular vein becomes more vertically separated from the carotid artery at more extreme angles of contralateral head rotation.


Assuntos
Cateterismo Venoso Central/métodos , Veias Jugulares/diagnóstico por imagem , Posicionamento do Paciente/métodos , Lesões do Sistema Vascular/prevenção & controle , Idoso , Artérias Carótidas/diagnóstico por imagem , Feminino , Seguimentos , Cabeça , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia
15.
J Clin Neurosci ; 22(6): 1021-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25769255

RESUMO

Prompted by our experience with complications occurring with apnea testing (AT), we discuss complications reported in the literature. AT is an integral part of brain death assessment. Many complications of AT have been described, including hypoxemia, arterial hypotension, tension pneumothorax and cardiac arrest. We conclude that a commonly used technique in conducting AT can create auto-positive end expiratory pressure (PEEP) and contributes to many complications. The mechanism of occult auto-PEEP in AT is discussed. Intensive care unit patients may have a compensated and asymptomatic relative hypovolemia that can be decompensated by a small amount of auto-PEEP produced by air trapping during insufflating oxygen (O2) through a 7.0 endotracheal tube (ETT). It could then lead to decreased preload, decreased stroke volume, decreased cardiac output and thus, to hypotension and a compensatory tachycardia. The placement of the standard O2 tubing (6mm outside diameter [OD]) inside the 7.0 ETT (7mm inside diameter [ID]) greatly decreased the ETT lumen (73%). We changed our practice to instead use readily available small pressure tubing to insufflate O2 for AT to avoid excessive reduction in the ETT lumen. The change from standard O2 tubing (6mm OD) to pressure tubing (3mm OD) will greatly decrease the reduction in cross-sectional area of 7.0 ETT lumen from 73 to 18% and avoid potential complications of air trapping, auto-PEEP and barotrauma. We have successfully used this new simple technique with readily available equipment to eliminate auto-PEEP in AT while preserving oxygenation.


Assuntos
Barotrauma/etiologia , Morte Encefálica/diagnóstico , Testes de Função Respiratória/efeitos adversos , Testes de Função Respiratória/métodos , Apneia/diagnóstico , Humanos , Oxigênio , Respiração com Pressão Positiva/efeitos adversos , Pressão , Respiração Artificial/efeitos adversos , Testes de Função Respiratória/instrumentação
16.
J Clin Med Res ; 7(4): 253-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25699122

RESUMO

BACKGROUND: Hypo-magnesemia is described to occur in as many as 65% of intensive care unit (ICU) patients. Magnesium (Mg) is a cofactor in over 300 enzymatic reactions involving energy metabolism, protein, and nucleic acid synthesis. The membrane pump that creates the electrical gradient across the cell membrane is dependent on Mg, and it is important in the activity of electrically excitable tissues. Since Mg regulates the movement of calcium in smooth muscle cells, it is also important in peripheral vascular tone and blood pressure. Studies have linked hypo-magnesemia to multiple chronic diseases and to a higher mortality rate. METHODS: To explore trends within our own tertiary care surgical ICU, we sampled our patients' laboratory records in 2001 and in 2011. Hypo-magnesemia in our ICU is defined as an Mg less than 2.0 mg/dL. RESULTS: This retrospective review of all SICU patients from October to December revealed that there was a significant increase (P < 0.01) in the patients with their serum Mg level measured between 2001 (89%) and 2011 (95%). There was a significant decrease (P < 0.001) in patients with hypomagnesemia (< 2 mg/dL) between 2001 (47.5%) and 2011 (33.0%). On the other hand, there was a significant increase (P < 0.001) in patients with normal serum Mg level (> 2 mg/dL) between 2001 (52.5%) and 2011 (67.0%). CONCLUSIONS: There was not only more monitoring of Mg in 2011, but a lower incidence of hypo-Mg compared to 2001. Possible explanations include changing patterns of antibiotic and diuretic use, less amphotericin use, more frequent laboratory surveillance, and better trained ICU practitioners.

18.
J Clin Med Res ; 7(1): 13-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25379067

RESUMO

BACKGROUND: Atherosclerotic disease in coronary artery bypass grafting (CABG) patients is a potential contributor to complications in the perioperative periods. This study was undertaken to better define how the frequency of aortic atheromatous disease among patients coming for CABG has evolved over the last decade. METHODS: Data from elective patients coming for CABG who underwent transesophageal echocardiography (TEE) examinations following induction of anesthesia were obtained for the years 2002 and 2009. Aortas were graded according to the method of Kronzon, with the following interpretations: normal = grade I, intimal thickening = 2, atheroma of less than 5 mm = 3, atheroma of > 5 mm = 4, and any mobile atheroma = 5. The data of 124 patients who underwent comprehensive exam of the aorta by one cardiac anesthesiologist were gathered and assigned into two groups based on the year TEE was done. Student's t-test was used for statistical analysis. A P value < 0.05 was considered significant. The data were presented as mean ± SD. RESULTS: There was significant difference between group 2002 (2.05 ± 1.28) and group 2009 (2.59 ± 1.11) in atheroma grade (P = 0.013). CONCLUSIONS: Patients coming for CABG in group 2009 exhibited significantly higher grades of aortic atheroma on TEE, compared to group 2002. Understanding the risk of atheroma in the elderly CABG population may help in altering surgical approaches to lessen the risk of catastrophic stroke. Potential options needing further study include the off-pump approach and modification of cross-clamp site and technique as well as other modalities.

19.
J Clin Med Res ; 7(2): 115-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25436029

RESUMO

The presence of fixed partial dentures presents a unique threat to the perioperative safety of patients that require orotracheal intubation or placement of instruments into the gastrointestinal (GI) tract. There are many chances for the displacement of a fixed partial denture: instrumentation of the airway for intubation, or introduction of temporary devices, such as gastroscopes or transesophageal echo probes. If dislodged, the fixed partial dentures can enter the hypopharynx, esophagus or lungs and cause perforations with their sharp tines. Oral or esophageal perforation can lead to potentially fatal mediastinitis. We describe a case of a patient with a fixed partial denture who underwent cardiac surgery with intubation and transesophageal echocardiography (TEE). His partial denture was intact after the procedure. After extubation, he reported that his teeth were missing. Multiple procedures were required to remove his dislodged partial dentures. In sign-out reports, verbal descriptions of the patient's partial dentures were not adequate in this case. A picture of the patient's denture and oral pharynx pre-operatively would have provided a more accurate template for the post-operative team to refer to when caring for the patient. This may have avoided the multiple potentially risky procedures the patient had to undergo. We describe a suggested protocol utilizing a pre-operative photo to reduce the incidence of unrecognized partial denture dislodgement in the perioperative period. Because the population is aging, this will become a more frequent issue confronting practitioners. This protocol could mitigate this complication.

20.
Int J Health Sci (Qassim) ; 8(4): 420-2, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25780360

RESUMO

OBJECTIVES: Hospital airway emergency teams are often responsible for responding to codes, emergency intubations etc. The individual provider may have to respond quickly to widely separated areas of large medical centers on a moment's notice. Further, in addition to the urgency, the distance of different sites makes it important that the airway team not have to lug a large medical gear bag with airway supplies and emergency drugs. While the importance of the LMA in emergency airway management has been well established, it is sold as a fairly bulky device that requires a disproportionate space in an airway pack. We sought to examine whether modifying the LMA packaging might reduce the amount of space taken up by the need to carry three different sizes in an airway pack. METHODS: A commonly used Laryngeal Mask Size Number 3 manufactured by Ambu Company was studied. The volume displacement of the package, and then just the LMA was measured using volumetric techniques. RESULTS: Removing the large packaging yielded a much smaller footprint in cubic ml that was only 18% of the original packaging: 43 versus 240 cubic milliliters. CONCLUSIONS: This configuration of LMA transport allows for transporting more airway equipment in less space. These results have important implications for emergency airway response teams. Removing the original packaging and using this folded-over configuration allows to use 82% less volume in cubic milliliters per LMA in the airway pack. This allows emergency teams to carry more equipment in much less space.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA