Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39115496

RESUMO

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy (ASGE) provides an evidence-based approach for the role of endoscopy in the management of chronic pancreatitis (CP). This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework. The guideline addresses effectiveness of endoscopic therapies for the management of pain in CP, including celiac plexus block, endoscopic management of pancreatic duct (PD) stones and strictures, and adverse events such as benign biliary strictures (BBSs) and pseudocysts. In patients with painful CP and an obstructed PD, the ASGE suggests surgical evaluation in patients without contraindication to surgery before initiation of endoscopic management. In patients who have contraindications to surgery or who prefer a less-invasive approach, the ASGE suggests an endoscopic approach as the initial treatment over surgery, if complete ductal clearance is likely. When a decision is made to proceed with a celiac plexus block, the ASGE suggests an EUS-guided approach over a percutaneous approach. The ASGE suggests indications for when to consider ERCP alone or with pancreatoscopy and extracorporeal shock wave lithotripsy alone or followed by ERCP for treating obstructing PD stones based on size, location, and radiopacity. For the initial management of PD strictures, the ASGE suggests using a single plastic stent of the largest caliber that is feasible. For symptomatic BBSs caused by CP, the ASGE suggests the use of covered metal stents over multiple plastic stents. For symptomatic pseudocysts, the ASGE suggests endoscopic therapy over surgery. This document clearly outlines the process, analyses, and decision processes used to reach the final recommendations and represents the official ASGE recommendations on the above topics.

2.
Gastrointest Endosc ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39078360

RESUMO

The publisher regrets that this article has been temporarily removed. A replacement will appear as soon as possible in which the reason for the removal of the article will be specified, or the article will be reinstated. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/policies/article-withdrawal.

3.
Endoscopy ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38942058

RESUMO

Introduction The role of endoscopic submucosal dissection (ESD) in the treatment of Barrett's associated neoplasia (BEN) has been evolving. We examined the efficacy and safety of ESD and EMR for BEN. Methods A database search was performed for studies reporting efficacy and safety outcomes of ESD and EMR for BEN. Pooled proportional and comparative meta-analyses were performed. Results 47 studies (23 ESD, 19 EMR, and 5 comparative) were included. Mean lesion size for ESD and EMR were 22.5 mm and 15.8 mm respectively. Majority of lesions were Paris type IIa. Pooled analysis for ESD showed en-bloc resection, R0 resection, curative resection, and local recurrence rates of 98%, 78%, 65%, and 2%, respectively. Complete eradication of dysplasia (CE-D) and complete eradication of intestinal metaplasia (CE-IM) were achieved in 94% and 59% of cases. Pooled rates of perforation, intraprocedural bleeding (IPB), delayed bleeding (DB), and stricture were 1%, 1%, 2%, and 10%, respectively. Pooled analysis for EMR showed en-bloc resection, R0 resection, curative resection, and local recurrence rates of 37%, 67%, 62%, and 6%, respectively. CE-D and CE-IM were achieved in 94% and 76% of cases. Pooled rates of perforation, IPB, DB, and stricture were 0.1%, 1%, 0.4%, and 7.7%, respectively. The mean procedure time for ESD and EMR were 111.3 and 22.3 mins respectively. Comparative analysis showed higher en-bloc and R0 resection rates with ESD compared to EMR, with comparable adverse events. Conclusion ESD and EMR both can be employed to treat BEN depending on the lesion type, size, and expertise.

4.
Gastrointest Endosc ; 99(5): 864, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38649230
5.
Am J Gastroenterol ; 119(7): 1383-1391, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38235741

RESUMO

INTRODUCTION: Adenoma per colonoscopy (APC) has recently been proposed as a quality measure for colonoscopy. We evaluated the impact of a novel artificial intelligence (AI) system, compared with standard high-definition colonoscopy, for APC measurement. METHODS: This was a US-based, multicenter, prospective randomized trial examining a novel AI detection system (EW10-EC02) that enables a real-time colorectal polyp detection enabled with the colonoscope (CAD-EYE). Eligible average-risk subjects (45 years or older) undergoing screening or surveillance colonoscopy were randomized to undergo either CAD-EYE-assisted colonoscopy (CAC) or conventional colonoscopy (CC). Modified intention-to-treat analysis was performed for all patients who completed colonoscopy with the primary outcome of APC. Secondary outcomes included positive predictive value (total number of adenomas divided by total polyps removed) and adenoma detection rate. RESULTS: In modified intention-to-treat analysis, of 1,031 subjects (age: 59.1 ± 9.8 years; 49.9% male), 510 underwent CAC vs 523 underwent CC with no significant differences in age, gender, ethnicity, or colonoscopy indication between the 2 groups. CAC led to a significantly higher APC compared with CC: 0.99 ± 1.6 vs 0.85 ± 1.5, P = 0.02, incidence rate ratio 1.17 (1.03-1.33, P = 0.02) with no significant difference in the withdrawal time: 11.28 ± 4.59 minutes vs 10.8 ± 4.81 minutes; P = 0.11 between the 2 groups. Difference in positive predictive value of a polyp being an adenoma among CAC and CC was less than 10% threshold established: 48.6% vs 54%, 95% CI -9.56% to -1.48%. There were no significant differences in adenoma detection rate (46.9% vs 42.8%), advanced adenoma (6.5% vs 6.3%), sessile serrated lesion detection rate (12.9% vs 10.1%), and polyp detection rate (63.9% vs 59.3%) between the 2 groups. There was a higher polyp per colonoscopy with CAC compared with CC: 1.68 ± 2.1 vs 1.33 ± 1.8 (incidence rate ratio 1.27; 1.15-1.4; P < 0.01). DISCUSSION: Use of a novel AI detection system showed to a significantly higher number of adenomas per colonoscopy compared with conventional high-definition colonoscopy without any increase in colonoscopy withdrawal time, thus supporting the use of AI-assisted colonoscopy to improve colonoscopy quality ( ClinicalTrials.gov NCT04979962).


Assuntos
Adenoma , Inteligência Artificial , Pólipos do Colo , Colonoscopia , Neoplasias Colorretais , Detecção Precoce de Câncer , Humanos , Colonoscopia/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Adenoma/diagnóstico , Adenoma/diagnóstico por imagem , Estudos Prospectivos , Pólipos do Colo/diagnóstico , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Detecção Precoce de Câncer/métodos , Idoso , Neoplasias Colorretais/diagnóstico , Estados Unidos , Valor Preditivo dos Testes , Análise de Intenção de Tratamento
6.
Gastroenterology ; 166(3): 496-502.e3, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38123023

RESUMO

BACKGROUND & AIMS: Gastrointestinal (GI) endoscopy procedures are critical for screening, diagnosis, and treatment of a variety of GI disorders. However, like the procedures in other medical disciplines, they are a source of environmental waste generation and energy consumption. METHODS: We prospectively collected data on total waste generation, energy consumption, and the role of intraprocedural inventory audit of a single tertiary care academic endoscopy unit over a 2-month period (May-June 2022). Detailed data on items used were collected, including procedure type (esophagogastroduodenoscopy or colonoscopy), accessories, intravenous tubing, biopsy jars, linen, and personal protective equipment use. Data on endoscope reprocessing-related waste generation and energy use in the endoscopy unit (equipment, lights, and computers) were also collected. We used an endoscopy staff-guided auditing and review of the items used during procedures to determine potentially recyclable items going to landfill waste. The waste generated was stratified into biohazardous, nonbiohazardous, or potentially recyclable items. RESULTS: A total of 450 consecutive procedures were analyzed for total waste management (generation and reprocessing) and energy consumption. The total waste generated during the study period was 1398.6 kg (61.6% directly going to landfill, 33.3% biohazard waste, and 5.1% sharps), averaging 3.03 kg/procedure. The average waste directly going to landfill was 219 kg per 100 procedures. The estimated total annual waste generation approximated the size of 2 football fields (1-foot-high layered waste). Endoscope reprocessing generated 194 gallons of liquid waste per day, averaging 13.85 gallons per procedure. Total energy consumption in the endoscopy unit was 277.1 kW·h energy per day; for every 100 procedures, amounting to 1200 miles of distance traveled by an average fuel efficiency car. The estimated carbon footprint for every 100 GI procedures was 1501 kg carbon dioxide (CO2) equivalent (= 1680 lbs of coal burned), which would require 1.8 acres of forests to sequester. The recyclable waste audit and review demonstrated that 20% of total waste consisted of potentially recyclable items (8.6 kg/d) that could be avoided by appropriate waste segregation of these items. CONCLUSIONS: On average, every 100 GI endoscopy procedures (esophagogastroduodenoscopy/colonoscopy) are associated with 303 kg of solid waste and 1385 gallons of liquid waste generation, and 1980 kW·h energy consumption. Potentially recyclable materials account for 20% of the total waste. These data could serve as an actionable model for health systems to reduce total waste generation and decrease landfill waste and water waste toward environmentally sustainable endoscopy units.


Assuntos
Gerenciamento de Resíduos , Humanos , Estudos Prospectivos , Gerenciamento de Resíduos/métodos , Instalações de Eliminação de Resíduos , Endoscopia Gastrointestinal/efeitos adversos , Pegada de Carbono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA