Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JAMA Netw Open ; 6(7): e2324630, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37477919

RESUMO

Importance: Maternal labor epidural analgesia (LEA) and oxytocin use for labor and delivery have been reported to be associated with child autism spectrum disorders (ASD). However, it remains unclear whether these 2 common medications used during labor and delivery have synergistic associations with ASD risk in children. Objective: To assess the independent associations of LEA and oxytocin during labor and delivery with ASD, as well as outcome modification associated with the concurrent use of both interventions. Design, Setting, and Participants: Data for this cohort study included 205 994 singleton births with vaginal deliveries in a single integrated health care system in Southern California from calendar years 2008 to 2017. Children were followed up to December 31, 2021. Data on use of LEA and oxytocin, covariates, and ASD outcome in children were obtained from electronic medical records. Cox proportional hazards regression was used to estimate the hazard ratios (HRs) adjusting for covariates. Exposures: Labor epidural analgesia and/or oxytocin use during labor and delivery. Main Outcomes and Measures: A child's clinical diagnosis of ASD during follow-up and at age of diagnosis. Results: Among the cohort, 153 880 children (74.7%) were exposed to maternal LEA and 117 808 children (57.2%) were exposed to oxytocin during labor and delivery. The population of children was approximately half boys and half girls. The median (IQR) age of the mothers was 30.8 (26.8-34.5) years for those not exposed to LEA, 30.0 (25.9-33.8) years for those exposed to LEA, 30.4 (26.5-34.1) years for those unexposed to oxytocin, and 30.0 (25.9-33.9) years for those exposed to oxytocin during labor and delivery. A total of 5146 children (2.5%) had ASD diagnosed during follow-up. Oxytocin exposure was higher among LEA-exposed (67.7%) than -unexposed (26.1%) children. The ASD risk associated with LEA was independent of oxytocin exposure (HR, 1.28; 95% CI, 1.18-1.38); however, the ASD risk associated with oxytocin was not significant after adjusting for LEA exposure (HR, 1.05; 95% CI, 0.99-1.12). A significant interaction of LEA and oxytocin on child ASD risk was found (P = .02 for interaction). Compared with no exposure, HRs were 1.20 (95% CI, 1.09-1.32) for LEA alone, 1.30 (95% CI, 1.20-1.42) for both LEA and oxytocin, and 0.90 (95% CI, 0.78-1.04) for oxytocin alone. Conclusions and Relevance: The findings of this cohort study suggest an association between maternal LEA and ASD risk in children, and the risk appeared to be further increased if oxytocin was also administered. Oxytocin exposure without LEA exposure was not associated with ASD risk in children. These findings must be interpreted with caution. Further studies are needed to replicate or refute the study results and examine biological plausibility.


Assuntos
Analgesia Epidural , Transtorno do Espectro Autista , Trabalho de Parto , Gravidez , Masculino , Feminino , Criança , Humanos , Adulto , Transtorno do Espectro Autista/induzido quimicamente , Transtorno do Espectro Autista/epidemiologia , Estudos de Coortes , Analgesia Epidural/efeitos adversos , Ocitocina/efeitos adversos , Analgésicos
2.
JAMA Pediatr ; 174(12): 1168-1175, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33044486

RESUMO

Importance: Although the safety of labor epidural analgesia (LEA) for neonates has been well documented, the long-term health effects of LEA on offspring remain to be investigated. Objective: To assess the association between maternal LEA exposure and risk of autism spectrum disorders (ASDs) in offspring. Design, Setting, and Participants: Data for this retrospective longitudinal birth cohort study were derived from electronic medical records from a population-based clinical birth cohort. A total of 147 895 singleton children delivered vaginally between January 1, 2008, and December 31, 2015, in a single integrated health care system were included. Children were followed up from the age of 1 year until the first date of the following occurrences: clinical diagnosis of ASD, last date of health plan enrollment, death, or the study end date of December 31, 2018. Exposures: Use and duration of LEA. Main Outcomes and Measures: The main outcome was clinical diagnosis of ASD. Cox proportional hazards regression analysis was used to estimate the hazard ratio (HR) of ASD associated with LEA exposure. Results: Among the cohort of 147 895 singleton children (74 425 boys [50.3%]; mean [SD] gestational age at delivery, 38.9 [1.5] weeks), 109 719 (74.2%) were exposed to maternal LEA. Fever during labor was observed in 13 055 mothers (11.9%) in the LEA group and 510 of 38 176 mothers (1.3%) in the non-LEA group. Autism spectrum disorders were diagnosed in 2039 children (1.9%) in the LEA group and 485 children (1.3%) in the non-LEA group. After adjusting for potential confounders, including birth year, medical center, maternal age at delivery, parity, race/ethnicity, educational level, household income, history of comorbidity, diabetes during pregnancy, smoking during pregnancy, preeclampsia or eclampsia, prepregnancy body mass index, gestational weight gain, gestational age at delivery, and birth weight, the HR associated with LEA vs non-LEA exposure was 1.37 (95% CI, 1.23-1.53). Relative to the unexposed group, the adjusted HR associated with LEA exposure of less than 4 hours was 1.33 (95% CI, 1.17-1.53), with LEA exposure of 4 to 8 hours was 1.35 (95% CI, 1.20-1.53), and with LEA exposure of more than 8 hours was 1.46 (95% CI, 1.27-1.69). Within the LEA group, there was a significant trend of ASD risk associated with increasing duration of LEA exposure after adjusting for covariates (HR for linear trend, 1.05 [95% CI, 1.01-1.09] per 4 hours). Adding fever to the model did not change the HR estimate associated with LEA exposure (adjusted HR for LEA vs non-LEA, 1.37 [95% CI, 1.22-1.53]). Conclusions and Relevance: This study suggests that maternal LEA may be associated with increased ASD risk in children. The risk appears to not be directly associated with epidural-related maternal fever.


Assuntos
Analgesia Epidural/efeitos adversos , Transtorno do Espectro Autista/etiologia , Índice de Massa Corporal , Trabalho de Parto , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , Adulto , Transtorno do Espectro Autista/epidemiologia , Peso ao Nascer , Pré-Escolar , Feminino , Seguimentos , Idade Gestacional , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Idade Materna , Gravidez , Estudos Retrospectivos , Estados Unidos/epidemiologia
3.
Respir Care ; 65(4): 482-491, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31992667

RESUMO

BACKGROUND: The prevalence of nuisance (technical) alarms is the leading cause of alarm fatigue resulting in decreased awareness and a reduction in effective care. The Joint Commission identified in their National Patient Safety goals alarm fatigue as a major safety issue. The introduction of noninvasive respiratory volume monitoring (RVM) has implications for effective perioperative respiratory status management. We evaluated this within the Kaiser Permanente health system. METHODS: This observational study was conducted at 4 hospitals in the Kaiser Permanente system. Standard data from RVM, pulse oximetry, and capnography were collected postoperatively in the post-anesthesia care unit (PACU) and/or on the general hospital floor. Device-specific alarm types, rates, and respective actions were recorded and analyzed by non-study staff. RESULTS: RVM was applied to 247 subjects (143 females, body mass index 32.3 ± 8.7 kg/m2, age 60.9 ± 13.9 y) providing 2,321 h. RVM alarms occurred 605 times (0.25 alarms/h); 64% were actionable and addressed, 17% were not addressed, 13% were self-resolved, and only 6% were nuisance. In a subgroup, RVM completed all 127 h of monitoring, whereas oximetry with capnography only completed 51 h with 12.9 alarms/h (73% nuisance). The overall RVM alarm rate was significantly lower than with either pulse oximeters or capnography monitors. We saw a nearly 1,000-fold reduction in nuisance alarms compared to capnography and a 20-50-fold reduction in nuisance alarms compared to pulse oximetry. CONCLUSIONS: Our study indicates that alarm fatigue due to nuisance alarms continues to be a clinical challenge in perioperative settings. Among the 3 common technologies for respiratory function monitoring, RVM had the lowest rate of overall technical alarms and the highest rate of compliance. Furthermore, with early interventions, none of the subjects monitored with RVM suffered any negative outcomes.


Assuntos
Capnografia/estatística & dados numéricos , Alarmes Clínicos/estatística & dados numéricos , Oximetria/estatística & dados numéricos , Período Perioperatório , Adulto , Idoso , Feminino , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Oxigênio , Segurança do Paciente , Volume de Ventilação Pulmonar
4.
J Shoulder Elbow Surg ; 21(4): 441-50, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22192767

RESUMO

BACKGROUND: In the last 2 decades, extensive research in postoperative pain management has been undertaken to decrease morbidity. Orthopedic procedures tend to have increased pain compared with other procedures, but further research must be done to manage pain more efficiently. Postoperative pain morbidities and analgesic dependence continue to adversely affect health care. MATERIALS AND METHODS: The study assessed the pain of 78 elbow and shoulder surgery patients preoperatively and postoperatively using the Short-Form McGill Pain Questionnaire (SF-MPQ). Preoperatively, each patient scored their preoperative pain (PP) and anticipated postoperative pain (APP). Postoperatively, they scored their 3-day (3dpp) and 6-week postoperative pain (6wpp). The pain intensities at these 4 intervals were then compared and analyzed using Pearson coefficients. RESULTS: APP and PP were strong predictors of postoperative pain. The average APP was higher than the average postoperative pain. The 6wpp was significantly lower than the 3dpp. Sex, chronicity, and type of surgery were not significant factors; however, the group aged 18 to 39 years had a significant correlation with postoperative pain. CONCLUSION: PP and APP were both independent predictors of increased postoperative pain. PP was also predictive of APP. Although, overall postoperative pain was lower than APP or PP due to pain management techniques, postoperative pain was still significantly higher in patients with increased APP or PP than their counterparts. Therefore, surgeons should factor patient's APP and PP to better manage their patient's postoperative pain to decrease comorbidities.


Assuntos
Cotovelo/cirurgia , Procedimentos Ortopédicos , Dor Pós-Operatória/epidemiologia , Ombro/cirurgia , Adulto , Comorbidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Inquéritos e Questionários , Fatores de Tempo , Lesões no Cotovelo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA